• 제목/요약/키워드: FAU

검색결과 44건 처리시간 0.026초

송이로부터 골프장 농약 제거를 위한 합성 제올라이트의 개발 (Development of Synthetic Zeolites from Scoria for Pesticides Removal in the Golf Course)

  • 감상규;안병준;주창식;이민규
    • 한국환경과학회지
    • /
    • 제10권6호
    • /
    • pp.451-459
    • /
    • 2001
  • Adsorption characteristics of triadimefon and diniconazole(pesticide) by natural zeolite($CLI_N$) and several synthetic zeolites were Investigated. The synthetic zeolites used En this study were as follows: Faujasite synthesized from coal fly ash($FAU_F$); Zeolite synthesized from the mixture of FAU and Na-Pl synthesized from the ratio of Cheju scoria 6 to coal fly ash 4 by weight($(FAU + Na-Pl)_{SF}$); waste fluid catalytic cracking catalyst($FCC_W$). The distribution coefficient, $K_D$ and Freundlich constant, $K_F$ decreased in the fellowing sequence : $FCC_W > FAU_F > (FAU + Na-Pl)_{SF} >CLI_N$ among the zeolites. The distribution coefficient and the adsorption capacity of $(FAU + Na-Pl)_{SF}$ for pesticides were 4.4 and 2.6 times higher for triamefon, and 2.0 and 2.4 times higher for diniconazole than those of $CLI_N$, respectively.

  • PDF

Adsorption Characteristics of Pesticides in Zeolites

  • Chang-Han Lee;Kil-Seong Kim;Sang-Kyu Kam
    • 한국환경과학회지
    • /
    • 제31권12호
    • /
    • pp.1103-1115
    • /
    • 2022
  • The adsorption characteristics of four pesticides (phosphamidon, fenitrothion, triadimefon, and diniconazole) on natural clinoptilolite (CLIN) and three synthetic zeolites were investigated. The synthetic zeolites included faujasite (FAUF) synthesized from coal fly ash; the mixture of FAU and Na-P1 (FAU + Na-P1)SF synthesized using Jeju scoria and coal fly ash at the ratio of 1.5 by weight; and waste fluid catalytic cracking catalyst (FCCW). The distribution coefficient, KD and the Freundlich constant, KF decreased in the following sequence: FCCW > FAUF > (FAU + Na-P1)SF > CLIN among the zeolites and diniconazole>fenitrothion> triadimefon> phosphamidon among the pesticides. The pesticide adsorptivity increased with increasing temperature for FAUF, (FAU+Na-P1)SF and FCCW, however, it decreased for CLIN, regardless of the type of pesticide. The adsorptivity of pesticides was independent of pH for phosphamidon, fenitrothion and triadimefon, whereas it decreased with increasing pH for diniconazole, regardless of zeolite type.

합성조건의 변화에 따른 FAU(Faujasite)형 제올라이트의 합성 (Synthesis of FAU(Faujasite)-type Zeolite with Variation of Synthesis Condition)

  • 임형미;김봉영;남중희;안병길;오성근;정상진
    • 한국세라믹학회지
    • /
    • 제40권2호
    • /
    • pp.132-138
    • /
    • 2003
  • 출발물질의 종류와 몰비 혼합 방법, 숙성, 결정화 온도와 결정화 시간 등 제올라이트 입자를 합성하는 조건이 FAU 형 제올라이트의 입자크기에 미치는 영향을 연구하였다. 동일한 출발물질이라도 혼합 경로에 따라 생성물의 결정상이 달랐다. 일반적으로 숙성과정을 거친 경우, 특히 숙성온도가 낮은 쪽이 입자 크기가 작았다. 2단계의 혼합겔 제조 방법을 거치는 경우 결정화 기간은 크게 단축되고 입자 크기도 작아졌으나. 1단계에서 제조된 2종의 혼합겔을 모두 숙성하지 않는 경우에는 결정화 시간은 단축되지만, 입자크기는 작아지지 않았다. 액상규산나트륨과 알루민산나트륨, 수산화나트륨을 출발물질로 하여. 저농도와 고농도의 혼합겔을 1차 제조하고, 이 혼합겔을 각각 숙성하고 다시 혼합하여 숙성하는 방법으로 결정화 시간을 단축하고 평균입경 0.4$\mu$m. 비표면적 838 $m^2$/g의 우수한 특성을 가지는 FAU혈 제올라이트를 합성하였다.

다양한 구조와 양이온을 갖는 제올라이트 분체의 수증기 흡착 거동 연구 (Adsorption of water vapor on zeolites of different framework types and alkali ions)

  • 송주섭;;김범주;김민지;한문희;조철희
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.160-168
    • /
    • 2014
  • 본 연구에서는 LTA, FAU, CHA, RHO 제올라이트 분체 9종의 298.15 K에서의 수증기 흡착 특성을 고찰하여 구조, Si/Al 몰 비, 양이온 종류가 제올라이트 분체의 수증기 흡착에 미치는 영향을 고찰하였다. 수증기 흡착량은 $RHO<CHA{\approx}LTA<FAU$ 제올라이트 분체 순으로 증가하였다. FAU 제올라이트 분체의 경우, Si/Al 몰 비가 작은 NaY 제올라이트 분체가 13X 제올라이트 분체에 비하여 우수한 수증기 흡착량(406 mg/g)을 보였다. LTA 제올라이트 분체의 경우, Ca로 치환 5A 제올라이트 분체가 3A, 4A 제올라이트 분체에 비하여 우수한 수증기 흡착량(282 mg/g)을 보였다. CHA 제올라이트 분체는 Si/Al 몰 비가 2.35으로 LTA 제올라이트 분체의 Si/Al 몰 비보다 컸지만 LTA 제올라이트 분체와 유사한 수증기 흡착량을 보였다. 또한, RHO 제올라이트 분체는 Si/Al 몰 비가 3.56으로 컸지만 (188 mg/g)으로 상당량의 수증기 흡착량을 보였다. 본 연구결과로부터 FAU, LTA 제올라이트 분체뿐만 아니라 Si/Al 몰 비가 커서 화학적 내구성이 우수할 것으로 예상되는 CHA, RHO 제올라이트 분체도 우수한 제습 흡착제임을 확인할 수 있었다.

제올라이트에 의한 농약의 흡착

  • 감상규;김길성;안병준;이민규
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.7-10
    • /
    • 2001
  • Adsorption of the pesticides (phosphamidon, fenitrothion, triadimefon and diniconazole) in natural zeolite (CL $I_{N}$) and several synthetic zeolites was incestigated. The pesticides were not adsorbed on zeolites (Na-Pl, SOD, ANA, JBW and CAN) synthesized from Jeju scoria. The distribution coefficient ( $K_{D}$) and the Freundlich constant ( $K_{F}$) decreased in the following sequences. FC $C_{W}$ (waste catalytic cracking catalyst)>FA $U_{F}$ (FAU Synthesized from coal fly ash)>(FAU+Na-Pl)$_{SF}$ (the mixture of FAU and Na-Pl synthesized from the ratio of Jeju scoria 6 to coal fly ash 4 by weight)>CL $I_{N}$ among the zeolites; diniconazole>fenitrothion> triadimefon>phosphamidon. As the temperature was increased, the amount of pesticide adsorbed per unit mass of zeolite increased for FC $C_{W}$, FA $U_{F}$ and (FAU+Na-Pl)$_{SF}$ but it decreased for CL $I_{N}$, for all the pesticides used in this study. It was independent of pH for phosphamidon, fenitrothion and triadimefon, but decresed as pH was increased for all the zeolites used in this study.y.udy.y.y.y.y.y.y.

  • PDF

GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증 (Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

Psychosocial Risk Management in the Teaching Profession: A Systematic Review

  • Wischlitzki, Elisabeth;Amler, Nadja;Hiller, Julia;Drexler, Hans
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.385-396
    • /
    • 2020
  • Teachers are facing various job demands with psychosocial aspects being fundamental due to the nature of the occupation. Although teachers' work is associated with different psychosocial health risks, little is known on how to identify and tackle those. Thus, a systematic literature search as per the PRISMA statement was conducted via MEDLINE (PubMed), PSYNDEX (PubPsych), and ScienceDirect. Two reviewers independently screened 2261 titles and abstracts and 169 full-texts. According to the inclusion criteria established a priori, articles from peer-reviewed journals (English or German) on psychosocial risk management in teachers were incorporated. Despite a comprehensive and sensitive search, only four publications could be identified, outlining a process to implement risk management and different assessment tools. Taken together, data presented in the articles were scarce. Recommendations for process steps and the assessment of psychosocial risks can be derived from the findings. To implement effective psychosocial risk management in the teaching profession, further research is needed, though. Effective and practicable approaches, which are accepted by the target group, should be further developed and investigated. Relevant causes of occupational strain in the teaching profession must be identified and assessed reliably. Low-threshold interventions should be implemented, and the outcome must be evaluated afterward.

The Effect of Co2+-Ion Exchange Time into Zeolite Y (FAU, Si/Al = 1.56): Their Single-Crystal Structures

  • Seo, Sung Man;Kim, Hu Sik;Chung, Dong Yong;Suh, Jeong Min;Lim, Woo Taik
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.243-249
    • /
    • 2014
  • Three single crystals of fully dehydrated $Co^{2+}$-exchanged zeolite Y (Si/Al = 1.56) were prepared by the exchange of $Na_{75}$-Y ($|Na_{75}|[Si_{117}Al_{75}O_{384}]$-FAU) with aqueous streams 0.05 M in $Co(NO_3)_2$, pH = 5.1, at 294 K for 6 h, 12 h, and 18 h, respectively, followed by vacuum dehydration at 673 K. Their single-crystal structures were determined by synchrotron X-ray diffraction techniques in the cubic space group Fd3m at 100(1) K. They were refined to the final error indices $R_1/wR_2$ = 0.0437/0.1165, 0.0450/0.1228, and 0.0469/0.1278, respectively. Their unit-cell formulas are $|Co_{29.1}Na_{11.8}H_{5.0}|[Si_{117}Al_{75}O_{384}]$-FAU, $|Co_{29.8}Na_{11.0}H_{4.4}|[Si_{117}Al_{75}O_{384}]$-FAU, and $|Co_{30.3}Na_{9.5}H_{4.9}|[Si_{117}Al_{75}O_{384}]$-FAU, respectively. In all three crystals, $Co^{2+}$ ions occupy sites I, I' and II; $Na^+$ ions are also at site II. The tendency of $Co^{2+}$ exchange slightly increases with increasing contact time as $Na^+$ content and the unit cell constant of the zeolite framework decrease.