• Title/Summary/Keyword: FAC

Search Result 330, Processing Time 0.027 seconds

An Analytic Study Measuring Factors Interrupting in Breast-Feeding (성공적인 모유수유를 저해하는 요인에 관한 분석적 연구)

  • Oh, Hyun-Ei;Park, Nan-Jun;Im, Eun-Sook
    • 모자간호학회지
    • /
    • v.4 no.1
    • /
    • pp.68-79
    • /
    • 1994
  • This study measured variables influencing the breast feeding patterns of lactating mothers over a 40 day period In 1993 in the Jeonla area. The Methodology used was a questionnaire covering 92 items based on statistical discriminant analysis. The results were as follows : The successful group was measured against the unsuccessful group over a 4month lactation period ; The successful group was measured over a 4month lactation period ; the unsuccessful less than 4month lactation period. Principal factor analysis was used to generate comparative data factors which were ; 1) nonunderstanding of mother's breast feeding, 2) physical and psychological stress, 3) insufficient milk supply, 4) mother's negative acceptance of baby, 5) lack of spousal support, 6) sore nipple and breast pain, 7) baby's negative acceptance, 8) lack of familial support, 9) baby's diarrhea and watery milk. Discriminant statistical analysis of sever factors included ; 1) insufficient milk supply 2) sore nipple and breast pain, 3) pre-natal planning of breast feeding method, 4) mother's occupation 5) breast feeding method of previous infant, 6) nipple type, and 7) infant birth order. This analysis predicted a 78.9% successful breast feeding. Criterion correlation analysis revealed ; D=-1.780+.165$\times$(Fac3)+.135$\times$(Fac6)+.927$\times$(prenatal planning of breast feeding method)+.900$\times$(mother's occupation)+.675$\times$ (breast feeding method of previous infant)+1.0l4$\times$(nipple type)+.378$\times$(infant birth order). We classified the unsuccessful group as more than .63937 and the successful group less than -.82742 of the D value obtained from the above criterion correlation in order to check the success or the non-success of breast feeding mothers. The rate of correct classification of the grouped cases employing a statistical discriminant analysis was significantly improved to 78.9% when these cases were compared with the actual grouped classification.

  • PDF

Effects of the Changes in Flow Pattern on Convective Heat Transfer in the Vicinity of Pipe Elbow (유동형태 변화가 배관 곡관부 대류열전달에 미치는 영향)

  • Song, Seung-Hyun;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • In this study, by varying flow patterns, which is one of the hydraulic factors of FAC, a strategy to reduce pipe wall thinning by mass transfer has been investigated. A similarity between heat transfer and mass transfer was verified via theoretical analysis, and local convective heat transfer coefficients were analyzed using a commercial numerical analysis program. When ribs were installed inside and outside of the internal surface in the straight section of the pipe, the maximum local heat transfer coefficient was shown to decrease substantially by up to 24.9% compared to the basic flow depending on the position and shape of ribs. If a guide vein was inserted in the pipe elbow, the maximum local heat transfer coefficient decreased by up to 26.7% compared to the basic flow depending on the internal surface area of the pipe by the guide vein.

Effect of Cr Addition to High Mn Steel on Flow-Accelerated Corrosion Behaviors in Neutral Aqueous Environments (Cr 첨가가 고망간강의 중성 수용액 환경 내 유동가속부식 거동에 미치는 영향)

  • Jeong, Yeong Jae;Park, Jin Sung;Bang, Hye Rin;Lee, Soon Gi;Choi, Jong Kyo;Kim, Sung Jin
    • Corrosion Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.373-383
    • /
    • 2021
  • The effect of Cr addition to high Mn steel on flow-accelerated corrosion (FAC) behavior in a neutral aqueous environment was evaluated. For comparison, two types of conventional ferritic steels (API X70 steel and 9% Ni steel) were used. A range of experiments (electrochemical polarization and impedance tests, weight loss measurement, and metallographic observation of corrosion scale) were conducted. This study showed that high Mn steel with 3% Cr exhibited the highest resistance to FAC presumably due to the formation of a bi-layer scale structure composed of an inner Cr enriched Fe oxide and an outer Mn substituted partially with Fe oxide on the surface. Although the high Mn steels had the lowest corrosion resistance at the initial corrosion stage due to rapid dissolution kinetics of Mn elements on their surface, the kinetics of inner scale (i.e. Cr enriched Fe oxide) formation on Cr-bearing high Mn steel was faster in dynamic flowing condition compared to stagnant condition. On the other hand, the corrosion scales formed on API X70 and 9% Ni steels did not provide sufficient anti-corrosion function during the prolonged exposure to dynamic flowing conditions.

Hall Effect on Couette Flow with Heat Transfer of a Dusty Conducting Fluid Between Parallel Porous Plates Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.569-579
    • /
    • 2006
  • In the present study, the unsteady Couette flow with heat transfer of a dusty viscous incompressible electrically conducting fluid under the influence of an exponential decaying pressure gradient is studied without neglecting the Hall effect. The parallel plates are assumed to be porous and subjected to a uniform suction from above and injection from below while the fluid is acted upon by an external uniform magnetic field is applied perpendicular to the plates. The governing equations are solved numerically using finite differences to yield the velocity and temperature distributions for both the fluid and dust particles.

Design on a Mobile Robot with Distributed Control based on CAN Protocol (CAN 통신기반 분산제어를 이용한 이동로봇 설계)

  • Choo, Yeon-Gyu;Kim, Bong-Gi;Jang, Ju-Han
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.864-866
    • /
    • 2012
  • 이동로봇은 동작 특성상 다수의 하드웨어로 구성되기 때문에 분산제어 방식으로 동작하는 것이 필수적이므로 네트워크 기반의 인터페이스 설계가 중요하다. 다양한 네트워크 중 전장에서 산업현장에 이르기까지 여러 분야에 적용중인 CAN 버스 통신을 적용하여 이동로봇을 구성하는 각 하드웨어의 독립성과 장애물 판단, 모터 구동 등을 정확하게 제어함으로써 자율주행에 따른 이동로봇의 성능을 향상시키고 하드웨어 추가에도 대응이 가능하도록 설계하였다.

  • PDF

The measurements of thermophysical properties of ceramics by single rectangular pulse heating method in transient heat source (방형파펄즈가열법에 의한 세라믹스의 열물성 측정에 관한 연구)

  • Cha, K.O.;Lee, K.H.;Yim, Going
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.6
    • /
    • pp.612-620
    • /
    • 1999
  • Thermophysical properties of the high-dielectric ceramics were measured by a single rectangular pulse heating method. The values of thermal diffusivities, specific heats, and thermal conductivities were measured as a function of temperature ranging from room temperature to 1300 K.

  • PDF

A Review on the Determination of the Protecting Duration of Frost Damage at Early Ages in Cold Weater Concreting Based on the Analysis of Strength Development (강도증진해석에 의한 한중콘크리트의 초기동해 방지기간 설정에 관한 검토)

  • 한민철;김효구;황인성;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.179-182
    • /
    • 1999
  • A protections from the frost damage at early ages is one of the serious problems to be considered in cold weather concreting. Frost damage at early ages brings about the harmful influences on the concrete structures such surface cracks and the loss of strength. Therefore, in this paper, the protecting durations of frost damage at early ages according to the standard specifications provided in KCI(Korean Concrete Institute) are suggested by appling logistic curve, which evaluates the strength development of concrete with maturity. According to the results, as W/C and compressive strength for protecting from frost damages at early ages increased, longer protecting duration is required. It shows that the protecting durations of FAC(Fly Ash Cement) are longer than those of OPC(Ordinary Portland Cement).

  • PDF

ON THE RELATIONSHIP BETWEEN SUBSTORM CURRENT SYSTEM AND BURSTY BULK FLOWS AT NEAR TAIL (서브스톰 전류계와 BBF 사이의 관계에 대하여)

  • LEE DAE-YOUNG;MIN KYOUNG WOOK
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc2
    • /
    • pp.53-56
    • /
    • 2000
  • We investigate the critical issue on how the BBF (bursty bulk flow) is related to the substorm current wedge formation. Observationally, after analysing data sets from Geotail spacecraft at near tail and many ground magnetic observatories for 9 months period of 1996, we find three BBF events that clearly occurred at the center of the wedge with region I type FAC (field-aligned current), and two other BBF events that were seen outside the wedge sector. Theoretically, we suggest that the substorm current wedge generation by BBF is most likely when the h' VB contribution is dominant in the well-known MHD $J_{II}$ expression (Vasyliunaus, 1984) or when the divergence of the cross-tail current carried by the particle's gradient/curvature drift is predominantly sufficient at the moment of the BBF arrival at near tail.

  • PDF

The Tree-Dimensional Grid Generation of Arbitrary Body (임의물체 주위의 3차원 격자생성)

  • 맹주성;손병진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.189-196
    • /
    • 1990
  • In the present study, a new method of generating boundary-fitted coordinates systems controlled by control function is introduced. Application of the method to a three-dimensional simply-connected region is the demonstrated. The numerical grid generation has following feat ures, (a) The generated boundary fitted coordinates is well concentrated in near wall region and satisfied orthogonality, (b) The grid control function is fully automatic and well controlled in sharp convex boundary.

A Fundamental Study on the Steel Corrosion Due to Carbonation of Concrete (콘크리트의 중성화로 인한 철근의 부식에 관한 기초적 연구)

  • 이창수;윤인석;최성기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.203-206
    • /
    • 1998
  • In reinforced concrete carbonation of concrete leads to depassivation of the reinforcement, and hence to initiation of corrosion. As a result of carbonation accelerating experiment with using effect of wet-dry cycle and 15% concentration of CO ₂, the carbonation rate shows very distinct difference according to W/C ratio. OPC-40 estimated no carbonation depth, whereas OPC-60 estimated rapidly the carbonation rate. The comparative analysis of the carbonation rate accelerating depends on different kinds of cement shows fastest FAC-20. Also, highly W/C ratio's concrete shows low half-cell potential value and fast corrosion rate. During period for 14 weeks. corrosion rate was not severe. So, it can be concluded that only carbonation attack on concrete doesn't severly deteriorated except very poor qualitified concrete.

  • PDF