• 제목/요약/키워드: FAC(Flow Accelerated Corrosion)

검색결과 79건 처리시간 0.023초

지역난방 배열 회수 보일러의 유동 가속 부식 원인 고찰 (Flow-Accelerated Corrosion Analysis for Heat Recovery Steam Generator in District Heating System)

  • 홍민기;채호병;김영수;송민지;조정민;김우철;하태백;이수열
    • 한국재료학회지
    • /
    • 제29권1호
    • /
    • pp.11-15
    • /
    • 2019
  • Severe wall thinning is found on the tube of a low-pressure evaporator(LPEVA) module that is used for a heat recovery steam generator(HRSG) of a district heating system. Since wall thinning can lead to sudden failure or accidents that lead to shutdown of the operation, it is very important to investigate the main mechanism of the wall thinning. In this study, corrosion analysis associated with a typical flow-accelerated corrosion(FAC) is performed using the corroded tube connected to an upper header of the LPEVA. To investigate factors triggering the FAC, the morphology, composition, and phase of the corroded product of the tube are examined using optical microscopy, scanning electron microscopy combined with energy dispersive spectroscopy, and x-ray diffraction. The results show that the thinnest part of the tube is in the region where gas directly contacts, revealing the typical orange peel type of morphology frequently found in the FAC. The discovery of oxide scales containing phosphate indicates that phosphate corrosion is the main mechanism that weakens the stability of the protective magnetite film and the FAC accelerates the corrosion by generating the orange peel type of morphology.

기계학습을 이용한 유동가속부식 모델링: 랜덤 포레스트와 비선형 회귀분석과의 비교 (Modeling of Flow-Accelerated Corrosion using Machine Learning: Comparison between Random Forest and Non-linear Regression)

  • 이경근;이은희;김성우;김경모;김동진
    • Corrosion Science and Technology
    • /
    • 제18권2호
    • /
    • pp.61-71
    • /
    • 2019
  • Flow-Accelerated Corrosion (FAC) is a phenomenon in which a protective coating on a metal surface is dissolved by a flow of fluid in a metal pipe, leading to continuous wall-thinning. Recently, many countries have developed computer codes to manage FAC in power plants, and the FAC prediction model in these computer codes plays an important role in predictive performance. Herein, the FAC prediction model was developed by applying a machine learning method and the conventional nonlinear regression method. The random forest, a widely used machine learning technique in predictive modeling led to easy calculation of FAC tendency for five input variables: flow rate, temperature, pH, Cr content, and dissolved oxygen concentration. However, the model showed significant errors in some input conditions, and it was difficult to obtain proper regression results without using additional data points. In contrast, nonlinear regression analysis predicted robust estimation even with relatively insufficient data by assuming an empirical equation and the model showed better predictive power when the interaction between DO and pH was considered. The comparative analysis of this study is believed to provide important insights for developing a more sophisticated FAC prediction model.

수치해석 기법을 활용한 FAC 예측 프로그램 보완 (Supplementation of Flow Accelerated Corrosion Prediction Program Using Numerical Analysis Technique)

  • 황경모;진태은;박원;오동훈
    • 대한기계학회논문집B
    • /
    • 제34권4호
    • /
    • pp.437-442
    • /
    • 2010
  • 고온, 고압의 유체가 흐르는 탄소강 배관에서는 유동가속부식으로 인한 배관감육 현상이 발생할 수 있다. 화력 및 원자력발전소에서 유동가속부식으로 인한 배관 손상시 고비용의 보수와 발전 정지를 유발할 뿐 아니라 발전소 신뢰도 및 안전성에 영향을 미칠 수도 있다. CHECWORKS 프로그램은 국내 발전소에서 유동가속부식에 의한 배관 손상을 예방하기 위하여 배관 두께검사 데이터를 평가하고 검사 계획을 수립하는데 이용되어 왔다. 그러나 상기 프로그램은 원전 2차측 배관 모두를 데이터베이스화한 후에 배관라인 그룹별로 유동가속부식 손상을 예측하기 때문에 국부적으로 감육에 민감한 부위를 찾는데 어려움이 있다. 본 논문에서는 CHECWORKS 프로그램을 이용하여 해석을 수행하고 수치해석을 통하여 검증할 수 있는 방법론을 기술하였다. 또한 국내 원전 2개의 배관 라인그룹에 대하여 CHECWORKS 프로그램을 이용한 유동가속부식 민감 부위를 FLUENT를 이용한 수치해석 결과와 비교하였다.

Flow Induced Material Degradation In Power Plant Secondary Systems-A Review

  • Kim, I.S.;Van Der Helm, M.;Ballinger, R.G.
    • Nuclear Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.148-163
    • /
    • 1998
  • Flow Induced Material Degradation (FIMD) is reviewed focusing on Flow Accelerated Corrosion (FAC) models. Several examples of FAC related incidents are described, which include nuclear and fossile power plants. Lastly, mitigation techniques such as inspection, material selection, water chemistry, temperature, and hydrodynamic factor are discussed.

  • PDF

Flow-accelerated corrosion assessment for SA106 and SA335 pipes with elbows and welds

  • Kim, Dong-Jin;Kim, Sung-Woo;Lee, Jong Yeon;Kim, Kyung Mo;Oh, Se Beom;Lee, Gyeong Geun;Kim, Jongbeom;Hwang, Seong-Sik;Choi, Min Jae;Lim, Yun Soo;Cho, Sung Hwan;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3003-3011
    • /
    • 2021
  • A FAC (flow-accelerated corrosion) test was performed for a straight pipe composed of the SA335 Gr P22 and SA106 Gr B (SA106-SA335-SA106) types of steel with welds as a function of the flow rate in the range of 7-12 m/s at 150 ℃ and with DO < 5 ppb at pH levels ranging from 7 to 9.5 up to a cumulative test time of 7200 h using the FAC demonstration test facility. Afterward, the experimental pipe was examined destructively to investigate opposite effects as well as entrance effects. In addition, the FAC rate obtained using a pipe specimen with a 50 mm inner diameter was compared with the rate obtained from a rotating cylindrical electrode. The effects of the complicated fluid flows at the elbow and orifice of the pipeline were also evaluated using another test section designed to examine the independent effects of the orifice and the elbow depending on the distance and the combined effects on orifice and elbow. The tests were performed under the following conditions: 130-150 ℃, DO < 5 ppb, pH 7 and a flow rate of 3 m/s. The FAC rate was determined using the thickness change obtained from commercial room-temperature ultrasonic testing (UT).

원전 2차계통의 수화학 변화가 배관감육에 미치는 영향 분석 (Analysis of Pipe Wall-thinning Caused by Water Chemistry Change in Secondary System of Nuclear Power Plant)

  • 윤훈;황경모;문승재
    • Corrosion Science and Technology
    • /
    • 제14권6호
    • /
    • pp.325-330
    • /
    • 2015
  • Pipe wall-thinning by flow-accelerated corrosion (FAC) is a significant and costly damage of secondary system piping in nuclear power plants (NPPs). All NPPs have their management programs to ensure pipe integrity from wall-thinning. This study analyzed the pipe wall-thinning caused by changing the amine, which is used for adjusting the water chemistry in the secondary system of NPPs. The pH change was analyzed according to the addition of amine. Then, the wear rate calculated in two different amines was compared at the steam cycle in NPPs. As a result, increasing the pH at operating temperature (Hot pH) can reduce the rate of FAC damage significantly. Wall-thinning is affected by amine characteristics depending on temperature and quality of water.

Evaluation of Piping Integrity in Thinned Main Feedwater Pipes

  • Park, Young-Hwan;Kang, Suk-Chull
    • Nuclear Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.67-76
    • /
    • 2000
  • Significant wall thinning due to flow accelerated corrosion(FAC)was recently reported in main feedwater pipes in 3 Korean pressurized water reactor(PWR) plants. The main feedwater pipes in one plant were repaired using overlay weld method at the outside of pipe, while those in 2 other plants were replaced with new pipes. In this study, the effect of the wall thinning in the main feedwater pipes on piping integrity was evaluated using finite element method. Especially, the effects of both the overlay weld repair and the stress concentration in notch-type thinned area on the piping integrity were investigated. The results are as follows : (1) The piping load carrying capacity may significantly decrease due to FAC. In special, the load carrying capacity of the main feedwater pipe was reduced by about 40% during about 140 months operation in Korean PWR plants. (2) By performing overlay weld repair at the outside of pipe, the piping load carrying capacity can increase and the stress concentration level in the thinned area can be reduced.

  • PDF

Flow-Accelerated Corrosion Behavior of SA106 Gr.C Steel in Alkaline Solution Characterized by Rotating Cylinder Electrode

  • Kim, Jun-Hwan;Kim, In-Sup
    • Nuclear Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.595-604
    • /
    • 2000
  • Flow-Accelerated Corrosion Behavior of SA106 Gr.C steel in room temperature alkaline solution simulating the CANDU primary water condition was studied using Rotating Cylinder Electrode. Systems of RCE were set up and electrochemical parameters were applied at various rotating speeds. Corrosion current density decreased up to pH 10.4 then it increased rapidly at higher pH. This is due to the increasing tendency of cathodic and anodic exchange half-cell current. Corrosion potential shifted slightly upward with rotating velocity. Passive film was formed from pH 9.8 by the mechanism of step oxidation and the subsequent precipitation of ferrous species into hydroxyl compound. Above pH 10.4, the film formation process was active and the film became stable. Corrosion current density showed increment in pH 6.98 with the rotating velocity, while it soon saturated from 1000 rpm above pH 9.8. This seems that activation process which represents formation of passive film on the bare metal surface controls the entire corrosion process

  • PDF

원전 2차계통수 모사 환경에서 용접배관 감육 특성에 미치는 재료 및 유속의 영향 (Effects of alloys and flow velocity on welded pipeline wall thinning in simulated secondary environment for nuclear power plants)

  • 김경모;정용무;이은희;이종연;오세범;김동진
    • Corrosion Science and Technology
    • /
    • 제15권5호
    • /
    • pp.245-252
    • /
    • 2016
  • The pipelines and equipments are degraded by flow-accelerated corrosion (FAC), and a large-scale test facility was constructed for simulate the FAC phenomena in secondary coolant environment of PWR type nuclear power plants. Using this facility, FAC test was performed on weld pipe (carbon steel and low alloy steel) at the conditions of high velocity flow (> 10 m/s). Wall thickness was measured by high temperature ultrasonic monitoring systems (four-channel buffer rod type and waveguide type) during test period and room temperature manual ultrasonic method before and after test period. This work deals with the complex effects of flow velocity on the wall thinning in weld pipe and the test results showed that the higher flow velocity induced different increasement of wall thinning rate for the carbon steel and low alloy steel pipe.