• 제목/요약/키워드: FA test

검색결과 250건 처리시간 0.029초

R-245fa 및 NOVEC 649 작동유체에 따른 ORC 시스템 성능 변화 (ORC System Performance Analysis upon R-245fa and Novec 649)

  • 장홍순;한영섭;송영길;김성현
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권3호
    • /
    • pp.17-23
    • /
    • 2016
  • A test unit for Organic Rankine Cycle (ORC) power generation system was developed and experimentally reviewed the performance of the ORC system. Two different organic fluids (R-245fa & Novec 649) were tested as working fluids for the system. System behavior was measured and analyzed along with the variables, such as temperature, pressure, rpm and shaft power. It is one of the findings that Novec 649 fluid is to be less pressurized than R-245fa in order to up to the heat source (boiler) capacity, that limits the experiment as high as 2 kW in shaft power.

FLASH를 이용한 3T 복부검사에 있어서 최적의 T1효과를 위한 적정 Flip Angle (Flip Angle of the Optimal T1 Effect Using FLASH Pulse Sequence at 3T Abdominal MRI)

  • 한재복;최남길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권1호
    • /
    • pp.101-106
    • /
    • 2009
  • 본 연구는 FLASH 펄스파형을 이용하여 숙임각(flip angle ; FA)변화에 따른 T1 강조영상의 신호강도(signal intensity ; SI)와 대조도 대 잡음비(contrast to noise ratio ; CNR)를 비교함으로써 복부검사에서의 최적의 T1효과를 나타내기 위한 FA를 알아보고자 하였다. 2008년 9월부터 12월까지 본원을 내원하여 복부 MRI 검사를 시행한 환자 20명(남 : 12명, 여 : 8명, 연령 범위 : $28{\sim}63$세, 평균 : 51세)을 대상으로 하였다. 영상 장비는 3Tesla MR scanner(Magnetom Tim Trio, SIEMENS, Germany)였으며, 8 channel body array coil을 사용하였다. 사용된 영상변수는 FLASH 펄스파형과 TR : 120 ms, TE : minimum, FOV : $360{\times}300\;mm$, Matrix : $256{\times}224$, Slice : 6 mm, scan time : 15초로 Breath-hold 기법을 이용하였다. 복부 영상은 물 신호를 동시에 측정하기 위해 관심영역(FOV) 안에 물을 채운 50 ml syringe를 놓고 $10^{\circ}$부터 $90^{\circ}$까지 $10^{\circ}$ 간격으로 FA에 변화를 주면서 얻었다. 획득한 영상은 간(liver), syringe내부의 물(water), 비장(spleen), background의 신호강도(SI)와 대조도 대 잡음비(CNR)를 각각 측정하였으며 신호강도는 관심영역을 설정한 다음 각 부위에서 3번씩 측정하고 그 평균값을 구하였다. 영상 전체의 평가에서는 변이계수(coefficient of variation)를 적용하여 전체영상의 신호강도 균일도를 알아보았고 통계 분석은 SPSS for window version 17.0을 이용하였다. 간(liver)의 신호강도는 $475.54{\pm}81.76$으로 FA $40^{\circ}$에서 가장 높게 나타났으며 syringe내부의 물의 신호는 $475.97{\pm}68.98$로 FA $20^{\circ}$에서 가장 높았으며 FA가 높아짐에 따라 다른 조직의 신호보다 많은 감소를 보였다. 비장의 신호는 $443.02{\pm}55.77$로 FA $30^{\circ}$에서 가장 높은 신호강도를 보였으며 FA가 높아짐에 따라 신호가 감소하였다. 조직의 신호강도에서 Liver vs Water와 Liver vs Spleen은 FA $30^{\circ}$를 제외한 전 구간에서 통계적으로 유의한 차이를 보였고 Water vs Spleen은 FA $60^{\circ}$, FA $70^{\circ}$, FA $80^{\circ}$에서만 유의한 차이를 보였다(p < 0.01). 전체영상의 신호강도는 $175.42{\pm}57.93$으로 FA $10^{\circ}$에서 가장 낮게 나타났으며 FA가 높아짐에 따라 증가하다가 떨어지는 양상을 보였다. 또한 변이계수(coefficient of variation)는 FA $10^{\circ}$와 FA $20^{\circ}$에서 33.02와 31.43으로 가장 높게 나타났다. FA $10^{\circ}$와 FA $20^{\circ}$는 전체영상의 신호강도 균일도가 다소 떨어지는 영상으로 왜곡이 심하게 나타났다. CNR은 liver-water에서 FA $30^{\circ}$에서 12.73으로 가장 낮게 나타났고 FA $10^{\circ}$에서 -46.97, FA $80^{\circ}$에서 29.36으로 가장 높게 나타났다. liver-spleen의 CNR에서는 FA $10^{\circ}$에서 -3.18로 가장 낮게 나타났으며 FA $80^{\circ}$에서 9.65로 가장 높게 나타났다. 결론적으로 FLASH 펄스 파형을 사용한 복부 영상에서 최적의 T1효과를 나타내기 위해서는 FA $80^{\circ}$를 사용하는 것이 유용할 것으로 생각된다.

  • PDF

치환방법에 따른 플라이애쉬를 다량 치환한 콘크리트의 공학적 특성 (The Mechanical Properties of Concrete Usinga Large Amount of Fly Ash for Replacement Method)

  • 김태완;김태식;진치섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제10권6호
    • /
    • pp.105-113
    • /
    • 2006
  • 본 연구는 잔골재와 굵은 골재를 전량 플라이애쉬로 치환한 콘크리트의 공학적 특성을 밝히기 위한 실험적 연구의 결과이다. 그리고 플라이애쉬 전량 치환 콘크리트의 유동성 저하 문제를 추가수량($W_f$)으로 해결하고자 하였다. 실험은 물-시멘트 비($W_c/C$)를 0.35, 0.45 그리고 물-플라이애쉬 비($W_f/FA$)를 0.35, 0.45로 하였다. 플라이애쉬 치환은 P와 Q의 두 가지 방법으로 하였다. P 방법은 플라이애쉬와 첨가수량($W_f$)의 중량이 골재의 중량과 같은 배합법이다[$FA+W_f$ = G (또는 S)]. Q 방법은 플라이애쉬와 골재의 중량이 같고 첨가수량($W_f$)을 추가하는 배합법이다 [$FA+W_f$ > G (또는 S)]. 실험은 굳기 전 콘크리트의 특성과 3, 7, 28 및 91일 압축강도 특성을 측정하였다. 실험결과 압축강도는 $Wc/C=0.35$, $W_f/C=0.35$ 일 때, P 치환법 중에서 잔골재 치환이 다른 배합들보다 향상되었다. Q 방법은 P 방법에 비해 유동성은 향상되었으나, 압축강도는 그렇지 않았다. 실험결과는 잔골재와 굵은 골재를 플라이애쉬로 전량 치환한 콘크리트의 유동성과 강도 특성이 향상됨을 알 수 있었고, 플라이애쉬 치환방법으로 효과적임을 보여주었다.

HALT와 고장분석을 이용한 STN LCD 모듈의 신뢰성 평가에 관한 연구 (Anapproach of Combining HALT and Failureanalysis for STNLCD Reliability Assessment)

  • 강보철;홍원식;조재립
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2004년도 품질경영모델을 통한 가치 창출
    • /
    • pp.85-89
    • /
    • 2004
  • This brief paper is an application of HALT(High Accelerated Life Test) and FA(Failure analysis) to improvement of STN LCD module. Before HALT the result of environmental test is good. So, we choose the technique of HALT to evaluate reliability. After HALT and Fa, we suggest some methods to improve reliability

  • PDF

광물질혼화재 혼합 모르타르의 해수침식 저항성 (Seawater Attack Resistance of Mortars Containing Mineral Admixtures)

  • 문한영;이승태;최강식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.527-530
    • /
    • 2002
  • In the present study, immersion test using artificial seawater was performed to evaluate the resistance of mortar specimens with or without ground granulated blast-furnace slag (SG) and fly ash (FA). Another variable was the fineness levels of SG (4,450, 6,000 and 8,000 ㎠/g). From the results of the immersion test for 270 days of exposure, the excellent resistance to seawater attack for SG mortar mixtures, especially in a high fineness levels, was confirmed. However, the reductions in compressive strength of FA mortar specimens was similar to those of OPC mortar specimens irrespective of replacement of FA.. In order to understand the deterioration mechanism due to seawater attack, X-ray diffraction (XRD) analysis were also carried out. Some reactants such as ettringite, gypsum, brucite and Friedel's salt were possibly detected through XRD technique.

  • PDF

콘크리트 혼화재료 사용에 따른 타일 부착안정성 실험적 연구 (Tile Adhesion Strength Change Testing based on Different Concrete Additive Agents)

  • 김범수;서현재;최은규;이정훈;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.165-166
    • /
    • 2017
  • The purpose of this study is to investigate the effect of tile adhesion failure due to weak adhesion with concrete admixture (FA, SP) on walls. The test specimens were divided into four types : (1) OPC 100% (2) OPC 80%+FA 20% (3) OPC 80%+SP 20% (4) OPC 60%+SP 40%, each adhered on a 650 × 650mm wall with 200mm thickness capable of attaching two insulation tiles (300 × 600mm). The tests were carried out on the four types of walls by mortar bedding application method, and after 4 weeks of curing period, adhesion strength test was carried out. The adhesion strength difference was investigated between the concrete wall with added admixture (FA, SP) and general concrete wall.

  • PDF

CGS를 잔골재로 활용하는 FA치환 콘크리트의 응결시간 추정시 개량형 듀로미터 사용 가능성 분석 (Utilization of Improved Durometer when Estimating Setting Time of FA Replacement Concrete Using CGS for Fine Aggregate)

  • 이혁주;신용섭;서항구;한인덕;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.81-82
    • /
    • 2019
  • In this study, the Proctor penetration resistance test value and the hardness value of the improved Durometer were compared and analyzed for the change in the FA replacement rate of the concrete using CGS fine aggregate. The results are summarized as follows. It is. 1) The Proctor penetration resistance test value and the hardness value of the improved Durometer showed a high correlation in the form of a curve. 2) About surface finish Super-resolution with the improved Durometer is considered to be useful when using about 50 HD and about 80 HD in the end to determine the surface finishing work time.

  • PDF

Bailey Method를 이용한 아스팔트 혼합물 최적배합설계 평가 (Evaluation of Mix Design for Asphalt Mixtures by Bailey Method)

  • 이동항;이관호
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4832-4836
    • /
    • 2012
  • 일반적으로 아스팔트 혼합물 배합설계는 많은 시간과 실험이 필요하다. 또한, 정밀한 배합설계 결과는 실험하는 사람의 숙련도와 밀접한 상관관계가 있다. 이러한 문제점을 해결하기 위하여 Bailey는 아스팔트 혼합물용 골재입도에 대한 연구를 통해 골재입도곡선에서 특정한 크기의 골재의 입도 및 통과중량비가 중요함을 제시하였다. 본 연구에서는 Bailey가 제안한 방법을 이용하여 19mm 밀입도 아스팔트 혼합물 및 미연방도로국의 배수성포장(PA 20mm) 혼합물에 대한 배합설계를 시행하였다. Bailey 방법을 이용한 아스팔트 혼합물용 골재입도 결정방법은 기존에 시행착오를 통합 배합설계방법에 비해 좀더 짧은 시간에 최적배합설계를 수행할 수 있음을 확인하였다. 19mm 밀입도 아스팔트 혼합물의 CA, $FA_c$, $FA_f$는 0.724, 0.440 및 0.455로 기준값을 만족하였다. PA 20mm 아스팔트 혼합물의 계산된 CA, $FA_c$, $FA_f$는 0.646, 0.476 및 0.450으로 기준값을 만족하였다.

낮은 핀관과 Turbo-C 촉진관에서 R245fa의 외부 응축 열전달계수 (External Condensation Heat Transfer Coefficients of R245fa on Low Fin and Turbo-C Tubes)

  • 심윤보;박기정;정동수
    • 설비공학논문집
    • /
    • 제21권3호
    • /
    • pp.167-175
    • /
    • 2009
  • In this study, condensation heat transfer coefficients(HTCs) of R22, R123, R134a and R245fa are measured on both 26fpi low fin and Turbo-C tubes. All data are taken at the vapor temperature of $39^{\circ}C$ with a wall subcooling of $3{\sim}8^{\circ}C$. Test results show that HTCs of the newly developed low vapor pressure alternative refrigerant, R245fa, are $7.8{\sim}9.2%$ and $10.3{\sim}18.6%$ higher than those of R123 for 26fpi low fin tube and Turbo-C tube respectively. For all refrigerants tested, HTCs of Turbo-C enhanced tube are higher than those of 26fpi low fin tube. For the low fin tube, Beatty and Katz's prediction equation yielded 20% deviation for all fluids. The heat transfer enhancement ratio of R245fa on the Turbo-C tube is $5.9{\sim}6.4$ while that of R123 is $5.7{\sim}5.9$. From the view point of environmental safety and condensation heat transfer, R245fa is a long term candidate to replace R123 currently used in centrifugal chillers.

Resistance to Corrosion of Reinforcement of High Volume Fly Ash Concrete

  • Kwon, S.O.;Bae, S.H.;Lee, H.J.;Lee, K.M.;Jung, S.H.
    • Corrosion Science and Technology
    • /
    • 제13권6호
    • /
    • pp.209-213
    • /
    • 2014
  • Due to the increasing of interest about the eco-friendly concrete, it is increased to use concretes containing by-products of industry such as fly ash(FA), ground granulated blast furnace slag(GGBFS), silica fume(SF), and etc. Especially, these are well known for improving the resistances to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance against corrosion of reinforcement of high volume fly ash(HVFA) concrete which is replaced with high volume fly ash for cement volume. For this purpose, the concrete test specimens were made for various strength level and replacement ratio of FA, and then the compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91, and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that the compressive strength of HVFA concrete was decreased with increasing replacement ratio of FA but long-term resistances against reinforcement corrosion and chloride ion penetration of that were increased.