• Title/Summary/Keyword: F0 slope

Search Result 96, Processing Time 0.026 seconds

A New Selective Membrane Electrode for Oxalate Based on N,N'-Bis(salicylidene)-2,2-dimethylpropane-1,3-diamine Ni(II)

  • Ardakani, M.Mazloum;Iranpoor, F.;Karimi, M.A.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.2
    • /
    • pp.398-404
    • /
    • 2008
  • A new solvent polymeric membrane electrode, based on N,N'-bis(salicylidene)-2,2-dimethylpropane-1,3-diamine Ni(II) as the ionophore, was designed. The oxalate-selective electrode has the dynamic range between 1.0 10-6 M and 1.0 10-1 M with a Nernstian slope of -28.7 1.0 mV per decade. The detection limit was 6.3 10-7 M. The proposed electrode revealed good selectivities for oxalate over a variety of other anions and could be used in a pH range of 2.0-7.8. The electrode can be used for at least two months without any considerable divergence in potential. The designed electrode was applied as an indicator electrode in the potentiometric determination of oxalate in real samples.

Assessment of Impact Rating Class and Deterioration Type on the Trails in Mt. Namsan District, Gyeongju National Park (경주국립공원 남산 지구의 탐방로 훼손 유형 및 환경피해도 평가)

  • Heo, Sang-Hyun;You, Ju-Han
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1431-1442
    • /
    • 2015
  • This study was carried out to systematically maintain and manage the trails by assessing the physical characteristics, the types of deterioration and impact rating class of trails located in Mt. Nam District of the Gyeongju National Park. The major trails followed 6 routes including Sambulsa-Geumobong(A), Yongjangsaji-Geumobong(B), Yongjanggol-Yiyoungjae-Gowibong(C), Cheonusa-Gowibong(D), Sangseojang-Forest road(E) and Tongiljeon-Forest road(F). The routes length of A was 2.2 km, 2.7 km of B, 3.4 km of C, 1.3 km of D, 2.0 km of E and 1.0 km of F. In the physical characteristics, A was the widest and F was the narrowest in the width and bared width of trail. In depth of erosion, B was the deepest and E was the shallowest. D was the steepest and E was the gentlest in the slope. In the results of analysing the types of deterioration, A were 13 types, 11 types of B, C and D, 10 types of E and 6 types of F. The times of appearance of deterioration types in A were 86 times, 75 times of B, 105 times of C, 48 times of D, 47 times of E and 13 times of F. In case of the impact rating class, trail erosion was II degree, I degree of trail expansion, root exposure, trail divergence and rock exposure.

Polymeric Iodide-ion Selective Electrodes Based on Urea Derivative as an Ionophore

  • Jeong, Dae-Cheol;Lee, Hyo-Kyoung;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.12
    • /
    • pp.1985-1988
    • /
    • 2006
  • The polymeric membrane electrodes based on urea derivative as an ionophore were prepared and studied for the iodide-ion selective electrode. This membrane exhibits a linear stable response over a wide concentration range ($1.0\;{\times}\;10^{-5}\sim1.0\;{\times}\;10^{-2}$) with a slope of -57.7 mV/decade, a detection limit of log[$I^-$] = -5.63, and a selectivity coefficient for iodide against perchlorate anion (log$K^{pot}_{I^-,j}$ = -1.42). The selectivity series of the membrane gives the follow as $I^-$ > $SCN^-$, $Sal^-$ > $ClO_4^-$ > $NO_3^-$ > $Br^-$ > $NO_2^-$ > $Cl^-$ > $F^-$. The proposed electrode showed good selectivity and response for iodide anion over a wide variety of other anions in pH 5.0 buffer solutions.

Evaluation of Accuracy of Spatio-Temporal Image Analysis Methods Using Artificial Images and Proposal of a Hybrid Method (인공시공간영상을 이용한 시공간영상분석법의 정확도 평가와 혼합분석법의 제안)

  • Kwonkyu Yu
    • Ecology and Resilient Infrastructure
    • /
    • v.11 no.3
    • /
    • pp.100-109
    • /
    • 2024
  • There are various methods in surface image velocimetry that can measure the flow velocity of a river surface using footage of a river surface. Among them, spatio-temporal image velocimetry (STIV) is widely used. This paper analyzed advantages and disadvantages of two STIV methods developed by the author, correlation-based STIV (C-STIV) and FFT-based STIV (F-STIV). This study also proposed a new method, hybrid STIV (H-STIV), that could supplement the advantages and disadvantages of the two existing methods by combining them. For the analyses, 20 cases of artificial spatio-temporal images, having image displacement ranging from 0.1 px/fr to 19.0 px/fr, were prepared. As a result, F-STIV was accurate with footage containing small image displacements and C-STIV was more accurate with footage containing large image displacements. For images with medium displacement, the two methods showed similar accuracies. Based on this result, H-STIV was proposed to adopt the result of F-STIV in displacements smaller than 2.0 px/fr (image strip slope 63.4°) and the result of C-STIV in larger displacements. As a result of applying the proposed method to argumentation, it was confirmed that H-STIV could calculate the flow velocity efficiently according to the situation.

Fabrication of Perchlorate Ion Selective PVC Membrane Electrode (과염소산 이온선택성 PVC막전극 제작)

  • 우인성;안형환;강안수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.298-305
    • /
    • 1998
  • The PVC membrane electrode for measuring perchlorate ion was developed by incorporating various quaternary ammonium sallts. The effect of chemical structure, the content of active material, the kind of plasticizers, and the membrane thickness on the electrode characteristic such as the linear response range and Nernstian slope of the electrode were studied. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of plasticizer(DBP). And the optimum membrane thickness was 0.45mm at this composition. Under the above condition, the linear response range was $10^{-1}~1.2\times10^{-6}$M, and the detection limit was $5.1\times10^{-7}$M with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below: $SCN^->I^-NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF

Photo-Induced Scalar Phenomena according to Thickness Dependence of Chalcogenide $As_{40}Ge_{10}Se_{15}S_{35}$ Thin Film (칼코게나이트 $As_{40}Ge_{10}Se_{15}S_{35}$ 박막에서 두께에 따른 광유기 스칼라 현상)

  • 이현용;박수호;정홍배
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.467-472
    • /
    • 1997
  • In this study, we investigated the thickness dependence of thermal bleaching(TB) effect as well as photo-induced scalar phenomena, such as photodrakening(PD) effect and photorefraction(PR) change, in chalcogenide A $s_{40}$ G $e_{10}$S $e_{15}$ $S_{35}$ thin films. We found that when these films were exposed for 15 minutes using blue-pass filtered Hg lamp(~4300$\AA$) after annealing for 30 minutes around the glass transition temperature Tg(20$0^{\circ}C$), the refractive index change ($\Delta$n) was varied up to 0.02~0.46 according to each thickness condition and the optical energy gap ($\Delta$ $E_{op}$ ) was shifted to a longer wavelength of approximately 0.67eV, especially for 1000$\AA$-thickness. Also, the TB PD effects have been understood by the results related to optical absorption characteristics. The TB effect could be estimated as increasing the stabilization of amorphous chalcogenide films since absorption slope of extended regions(U) was not changed by annealing. On the other hand, the PD effect could be understood as due to the enhancement of disorder since U and the slope of Urbachs tail(1/F) around an absorption edge were decreased by exposing.ing.n edge were decreased by exposing.

  • PDF

Study on Flame Height Equation for the Pinus densiflora Surface Fuel Bed (소나무 낙엽층 화염높이 산정식에 관한 연구)

  • Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.10-15
    • /
    • 2009
  • Flame height calculation in a forest fire is a crucial part of predicting horizontal or vertical flame spread flared by radiation heat transfer. Flame height, which is one of the flame characteristics, can be estimated by the average height of luminous flame. This research relied on flame height observation test on P. densiflora surface fuel bed, which are surface combustibles in a forest, and calorimeter to measure Heat Release Rate, thus produced $H_f=0.027(\dot{Q'})^{2/3}$, flame height calculation equation for surface fuel. The research did not take into consideration such conditions as external velocity, slope and other variables that could affect flame height. According to comparison among experiment results, calculation results of the above formula and those of existing Heskestad formula (1998), it was found that standard error in fallen pine needles between experimental results and calculation results of the above formula amounts to 0.08, whereas standard error in same plant between experimental results and calculation results of existing Heskestad formula amounts to 0.23.

Evaluation of Radio-Frequency Performance of Gate-All-Around Ge/GaAs Heterojunction Tunneling Field-Effect Transistor with Hetero-Gate-Dielectric by Mixed-Mode Simulation

  • Roh, Hee Bum;Seo, Jae Hwa;Yoon, Young Jun;Bae, Jin-Hyuk;Cho, Eou-Sik;Lee, Jung-Hee;Cho, Seongjae;Kang, In Man
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2070-2078
    • /
    • 2014
  • In this work, the frequency response of gate-all-around (GAA) Ge/GaAs heterojunction tunneling field-effect transistor (TFET) with hetero-gate-dielectric (HGD) and pnpn channel doping profile has been analysed by technology computer-aided design (TCAD) device-circuit mixed-mode simulations, with comparison studies among ppn, pnpn, and HGD pnpn TFET devices. By recursive tracing of voltage transfer curves (VTCs) of a common-source (CS) amplifier based on the HGD pnpn TFET, the operation point (Q-point) was obtained at $V_{DS}=1V$, where the maximum available output swing was acquired without waveform distortion. The slope of VTC of the amplifier was 9.21 V/V (19.4 dB), which mainly resulted from the ponderable direct-current (DC) characteristics of HGD pnpn TFET. Along with the DC performances, frequency response with a small-signal voltage of 10 mV has been closely investigated in terms of voltage gain ($A_v$), unit-gain frequency ($f_{unity}$), and cut-off frequency ($f_T$). The Ge/GaAs HGD pnpn TFET demonstrated $A_v=19.4dB$, $f_{unity}=10THz$, $f_T=0.487$ THz and $f_{max}=18THz$.

A Study on the Properties of CSPE According to Accelerated Thermal Aging Years

  • Lee, Jung-Hoon;Kang, Myeong-Kyun;Jeon, Jun-Soo;Lee, Seung-Hoon;Kim, In-Yong;Park, Hyun-Shin;Shin, Yong-Deok
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.643-648
    • /
    • 2014
  • The accelerated thermal aging of CSPE (chlorosulfonated polyethylene) was carried out for 40.41, 121.22, and 202.04 days at $100^{\circ}C$, which are equivalent to 20, 60, and 100years of aging at $50^{\circ}C$, respectively. The volume electrical resistivities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were $1.107{\times}10^{14}-2.097{\times}10^{14}$, $7.752{\times}10^{13}-1.556{\times}10^{14}$, $7.693{\times}10^{13}-1.521{\times}10^{14}$, and $7.380{\times}10^{13}-1.304{\times}10^{14}{\Omega}{\cdot}cm$, respectively, at room temperature. The permittivities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were $2.89{\times}10^{-11}-3.65{\times}10^{-11}$, $3.40{\times}10^{-11}-3.70{\times}10^{-11}$, $3.50{\times}10^{-11}-3.82{\times}10^{-11}$, and $3.76{\times}10^{-11}-4.13{\times}10^{-11}$ F/m, respectively, at room temperature. The EAB (elongation at break) of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were 98.8-101.3, 59.5-60.3, 37.8-39.2, and 41.8-44.3%, respectively, at room temperature. The apparent densities of the accelerated thermally aged CSPE samples for 0, 40.41, 121.22, and 202.04 days were 1.603-1.614, 1.611-1.613, 1.622-1.628, and $1.618-1.620g/cm^3$, respectively, at room temperature. The measured currents of the accelerated thermally aged CSPE and the standard sample were almost constant after 5 min of applying a 300-V/mm electric field to the CSPE. The V-I slope of the accelerated thermally aged CSPE sample was increased if the applied electric field was increased at room temperature, and the V-I slope of the accelerated thermally aged CSPE was higher than that of standard CSPE.

Value of Additional Instrumented Fusion in the Treatment of Thoracic Ossification of the Ligamentum Flavum

  • Hwang, Sung Hwan;Chung, Chun Kee;Kim, Chi Heon;Yang, Seung Heon;Choi, Yunhee;Yoon, Joonho
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.719-729
    • /
    • 2022
  • Objective : The ossification of the ligamentum flavum (OLF) is one of the major causes of thoracic myelopathy. Surgical decompression with or without instrumented fusion is the mainstay of treatment. However, few studies have reported on the added effect of instrumented fusion. The objective of this study was to compare clinical and radiological outcomes between surgical decompression without instrumented fusion (D-group) and that with instrumented fusion (F-group). Methods : A retrospective review was performed on 28 patients (D-group, n=17; F-group, n=11) with thoracic myelopathy due to OLF. The clinical parameters compared included scores of the Japanese Orthopedic Association (JOA), the Visual analogue scale of the back and leg (VAS-B and VAS-L), and the Korean version of the Oswestry disability index (K-ODI). Radiological parameters included the sagittal vertical axis (SVA), the pelvic tilt (PT), the sacral slope (SS), the thoracic kyphosis angle (TKA), the segmental kyphosis angle (SKA) at the operated level, and the lumbar lordosis angle (LLA; a negative value implying lordosis). These parameters were measured preoperatively, 1 year postoperatively, and 2 years postoperatively, and were compared with a linear mixed model. Results : After surgery, all clinical parameters were significantly improved in both groups, while VAS-L was more improved in the F-group than in the D-group (-3.4±2.5 vs. -1.3±2.2, p=0.008). Radiological outcomes were significantly different in terms of changes in TKA, SKA, and LLA. Changes in TKA, SKA, and LLA were 2.3°±4.7°, -0.1°±1.4°, and -1.3°±5.6° in the F-group, which were significantly lower than 6.8°±6.1°, 3.0°±2.8°, and 2.2°±5.3° in the D-group, respectively (p=0.013, p<0.0001, and p=0.037). Symptomatic recurrence of OLF occurred in one patient of the D-group at postoperative 24 months. Conclusion : Clinical improvement was achieved after decompression surgery for OLF regardless of whether instrumented fusion was added. However, adding instrumented fusion resulted in better outcomes in terms of lessening the progression of local and regional kyphosis and improving leg pain. Decompression with instrumented fusion may be a better surgical option for thoracic OLF.