• 제목/요약/키워드: F0 Range

검색결과 1,444건 처리시간 0.026초

순환모델에 근거한 저소득층 중년여성의 가족기능과 정신건강 (Analysis of Family Function and Mental Health State for Low-income Middle-aged Women)

  • 반금옥;박지원
    • 재활간호학회지
    • /
    • 제13권2호
    • /
    • pp.132-139
    • /
    • 2010
  • Purpose: The purpose of this study was to identify the types of family function and mental health in low-income middle aged women using the circumplex model. Method: A descriptive research design was used. A sample of 116 low income middle aged women participated in the study. The Family Adaptability and Cohesion Evaluation Scale III was used to measure the types of family function. Mental health was measured by the SCL. Results: The types of family function identified were balance family (59.4%), extreme family (25.9%), and mid-range family (14.7%). Significant differences were found in mental health by the family cohesion (F=3.44, p=.019) and family adaptability (F=3.31, p=.023). The mental health status of extreme family was better than mid-range family and balanced family, but such result was not statistically significant (F=0.25, p=.783). Conclusion: The Circumplex model's main hypothesis was not empirically supported that extreme family has more problematic than mid-range family and balance family. These findings emphasize the need for the development of a family system model for Korean family.

$La_{0.7}Sr_{0.3}FeO_{3}$ 세라믹스의 전기전도 특성 (Electrical Transport Properties of $La_{0.7}Sr_{0.3}FeO_{3}$)

  • 정우환
    • 한국전기전자재료학회논문지
    • /
    • 제14권5호
    • /
    • pp.376-382
    • /
    • 2001
  • Magnetic and transport properties in the ceramic specimen of L $a_{0.7}$S $r_{0.3}$Fe $O_3$ with orthohombic structure has been investigated. Weak ferromagnetism has been observed in a ceramic sample of L $a_{0.7}$S $r_{0.3}$Fe $O_3$. Large dielectric relaxation of Debye type is observed in paramagnetic states within the temperature range of 130K~200K. From the temperature dependence of the characteristic frequency, we concluded that the elementary process of the dispersion is related to holes hopping between F $e^{3+}$ and F $e^{4+}$ ions. The temperature dependencies of thermoelectric power and Dc conductivity suggest that the charge carrier responsible for the conduction are strongly localized. These experimental results have been interpreted in terms of a hopping process involving small polaron.n.laron.n.

  • PDF

Genetic diversity and structure of natural populations of Picea jezoensis in South Korea

  • Lee, Seok Woo;Yang, Byeong Hoon;Hur, Seong Doo;Lee, Jung Joo;Song, Jeong Ho;Moriguchi, Yoshinari
    • 한국산림과학회지
    • /
    • 제97권2호
    • /
    • pp.187-195
    • /
    • 2008
  • Picea jezoensis (Sieb. et Zucc.) Carriere is one of the major and widespread components of the cold-temperate and boreal forests in Russian Far East, northeast China, Korea, and Japan. However, it is restricted to a highly fragmented range in South Korea with small populations. Mean expected heterozygosity $(H_e)$ based on 22 loci in 11 isozyme systems was 0.077 for four sampled populations that covered the whole distribution range of P. jezoensis in South Korea. This value is within the range reported for conifers, but it is very low compared to that of other spruce species as well as that of P. jezoensis populations in Russian Far East. Most populations had a slight excess of heterozygotes and the Wright's $F_{IS}$ (-0.019) was comparable to that previously reported for other spruce species. In all of the four populations, the Wilcoxon sign-rank test indicated no greater heterozygosity than that expected for populations at mutation-drift equilibrium, suggesting that the populations have not been bottlenecked recently. Despite a fragmented range and isolated populations, population differentiation was not high $(F_{ST}=0.047)$ and the number of migrants per generation was 5.09. Nei's genetic distances were also small $({\bar{D}}=0.005)$ but strongly related to geographic distances between populations, suggesting an Isolation by Distance. The northernmost isolate, Mt. Gyebang population was genetically distinct from the other three populations. Implications for the conservation of genetic variation of P. jezoensis in South Korea were discussed.

$Pb(Mg_{1/3}Nb_{2/3})O_3$ 고용체에서 고분해능 투과전자현미경을 이용한 구조 규칙화에 대한 연구 (High-resolution Transmission Electron Microscopy of Ordered Structure for Lead Magnesium Niobate Solid Solutions)

  • 박경순
    • Applied Microscopy
    • /
    • 제27권1호
    • /
    • pp.101-109
    • /
    • 1997
  • La이 첨가되고 또한 첨가되지 않은 $Pb(Mg_{1/3}Nb_{2/3})O_3$ 고용체에서 Mg과 Nb의 비화학양론적인 구조 규칙화 현상이 고분해능 전자현미경과 컴퓨터 이미지 시뮬레이션에 의해 연구되었다. 고분해능 격자 이미지는 여러 이미지 형성 조건과 대물렌즈 구경에서 얻었다. 컴퓨터 이미지 시뮬레이션은 여러 시편 두께, 초점 거리, 장거리 규칙도에서 실시되었다. 규칙격자 구조를 가지는 영역의 격자 이미지는 장거리 규칙도에 크게 의존되는 것이 발견되었다. 규칙격자 구조를 가지는 영역에 있어서, 실험 격자 이미지와 컴퓨터 시뮬레이션 이미지의 비교로부터, 규칙격자 구조를 가지는 영역의 장거리 규칙도는 $0.2\sim0.7$의 간을 가지고 있는 것이 관찰되었다. 또한 규칙격자는 $(NH_4)_3FeF_6$ 결정구조를 가지고 있었다.

  • PDF

한국산 무미류에 대한 유전학적 연구 : 청개구리속 2종(Hyla japonira, H. suweonensis)에 대한 mtDNA의 크기 및 제한효소 인식위치의 변이 (Genetic Studies on Korean Anurans: Length and Restriction Site Variation in the Mitochondrial DNA of Tree Frogs, Hyla japonica and H. suweonensis)

  • 이혜영;박창신
    • 한국동물학회지
    • /
    • 제35권2호
    • /
    • pp.219-225
    • /
    • 1992
  • The genetic variation in mitochondrial DNA (mtDNA) was analysed within and between two species of tree frogs. Hyla japonica and H. suweonensis from South Korea. Purified mtDNAs were digested with each of 11 restriction enLvmes which cleave at six base recognition sequences. The genome size of H. iaponica revealed ho types (20.0 $\pm$ 0.3 and 19.6 $\pm$ 0.3 kb) and this difference is explained by either addition or deletion of about 0.4 kb fragment. On the other hand, the genome sire of H. suueonensis was about 19.0 $\pm$ 0.4 kb only. For the analysis, level of fragment homology (F) and nucleotide sequence divergence (p) were estimated from comparisons of digestion profiles. Among four populations of H. iaponica, substantial mean sequence divergence was 0.017 (range 0.001-0.026); between identical types, 0.001 IslilaRl type) and 0.004 (Large type) respectively; between different ones, 0.024 (range 0.023-0.026). The level of sequence divergence between he species was 0.142 (range 0.131-0.146). This result suggested that he species ㅂwere distinctly differentiated species. The divergence time between ko species was estimated 7.1 million years.

  • PDF

$C_{3}F_{8}-Ar$혼합가스 상에서 $C_{3}F_{8}$분자가스의 비탄성단면적의 재결정 (Re-determination of inelastic collision cross sections for $C_{3}F_{8}$ molecular gas in $C_{3}F_{8}-Ar$ mixture gases)

  • 전병훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.21-23
    • /
    • 2005
  • The electron transport coefficients, the electron drift velocity W, the longitudinal diffusion coefficient $ND_L$ in $C_{3}F_{8}-Ar$ mixture gases were measured by Double shutter drift tube and calculated by multi-term approximation of the Boltzmann equation over the wide E/N range from 0.03 to 100 Td. And an inelastic collision cross sections for $C_{3}F_{8}$ molecular gas were redetermined for quantitative characteristic analysis.

  • PDF

Closure Duration and Pitch as Phonetic Cues to Korean Stop Identity in AP-medial Position: Perception Test

  • Kang, Hyun-Sook;Dilley, Laura
    • 음성과학
    • /
    • 제14권4호
    • /
    • pp.25-39
    • /
    • 2007
  • The present study investigated some perceptual phonetic attributes of two Korean stop types, aspirated and lax, in medial position of an accentual phrase. The intonational pattern across syllables (Jun, 1993) is argued to depend on the type of stop (aspirated vs. lax) only in the initial position of an accentual phrase. In Kang & Dilley (2007), we showed that significant differences between aspirated and lax stops in medial position of an accentual phrase exist in closure duration, voice-onset time, and fundamental frequency (F0) values for post-stop vowels. In the present perception experiment, we investigated whether these phonetic attributes contribute to the perception of these two types of stops: The closure durations and/or F0's of post-stop vowels on accentual-phrase medial words were altered and twenty native Korean speakers then judged these words as beginning with an aspirated or lax stop. Both closure duration and F0 significantly affected judgments of stop identity. These results indicate that a wider range of acoustic cues that distinguish aspirated and lax Korean stops in production also plays a role in perception. To account for these results we suggest some phonetic and phonological models of consonant-tone interactions for Korean.

  • PDF

경락 마사지가 뇌성마비장애인의 근력, 관절운동범위 및 일상생활활동에 미치는 영향 (The Effect of Meridian Massage on Muscle Power, ROM, and ADL in Persons with Cerebral Palsy)

  • 오미정;최경희
    • 기본간호학회지
    • /
    • 제10권1호
    • /
    • pp.68-77
    • /
    • 2003
  • Purpose: This study analyzed the effects of meridian massage on the muscle power, ROM, and ADL in persons with cerebral palsy. Method: A non-equivalent pre-test/post-test design was used. The data were collected from August to October, 2000 from 10 persons with cerebral palsy (a control group of 5 and an experimental group of 5). Muscle power was evaluated with the Brunnstrom-Dennen gravity test, ROM with a goniometer, and ADL with a self developed ADL scale. T-test, repeated measure ANOVA were used for statistical analysis. Result: The results are; 1. For muscle power, both time series group difference (F=10.66, p=0.000) and the total period group difference (F=72.67, p=0.000) were significant between the two groups. 2. ROM was not significantly different between the two groups. 3. For ADL, both time series group difference (F=7.09, p=0.001) and total period group difference (F=35.99, p=0.000) were significant between the two groups. Conclusion: Overall, this study shows that Meridian massage is effective for muscle power, ROM, and ADL in persons with cerebral palsy person. So it can be used to develope effective nursing programs to improve the function of motion of persons with cerebral palsy.

  • PDF

FMCW방식의 자동차 레이더 신호처리부 설계 및 구현 (Design and Implementation of DSP module for Automotive Radar System using FMCW)

  • 오우진
    • 대한전자공학회논문지TC
    • /
    • 제41권12호
    • /
    • pp.77-84
    • /
    • 2004
  • ITS를 위한 차량 충돌 방지 시스템인 FMCW 방식의 자동차 레이더를 분석하고 이에 적합한 신호처리부를 설계하고 구현하였다. 77GHz 대역의 FMCW 레이더에 대하여 성능 파라미터를 거리와 속도 해상도가 각각 0.4m, 0.67Km/h이 되도록 설계하였으며, 다중 물체의 검출을 위한 다수의 비트주파수를 조합하는 방법에 대하여 검토했다. 또한 거리 주파수인 $f_r$과 속도 주파수 $f_d$의 범위를 다르게 설정하여 다중 물체의 처리가 훨씬 간단해지는 것을 보였다. 다중 물체들의 거리차로 인한 감쇄를 보정하도록 미분기를 전처리단에 사용하여 ADC 비트수를 8bit로도 충분히 검출할 수 있음을 보였다. 제안한 방법과 설계한 파라미터 값들을 사용하여 Matlab으로 모의실험으로 검증하고 DSP와 마이크로프로세서를 이용하여 구현하였다.

ASBR(Anaerobic Sequencing Batch Reactor) 공정의 F/R비가 암모니아가 탈기된 축산폐수의 유기물 제거에 미치는 영향 (Effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) Process on Removal of the Organic Matters in Ammonia Stripped Swine Wastewater)

  • 황규대;조영무
    • 한국물환경학회지
    • /
    • 제21권6호
    • /
    • pp.687-694
    • /
    • 2005
  • Lab-scale experiments have been carried out to investigate the effect of F/R ratio of ASBR (Anaerobic Sequencing Batch Reactor) process on the removal of the organic matters in ammonia stripped swine wastewater. Three ASBR inoculated with sludge mixed with granular sludge of UASB (Upflow Anaerobic Sludge Blanket) and anaerobic digested sludge of municipal wastewater treatment plant were operated. Ammonia stripped swine wastewater was used as influent. Prior to conducting the experiments with varied conditions, the effect of increasing organic loading rate from 2.34 to $5.79gTCOD_{Cr}/L$-day at a fixed F/R ratio of 0.1 on the organic removal efficiency has been studied during start-up period. As the result of the experiment, under the condition of varied organic loadings, less than $4.14gTCOD_{Cr}/L$-day, the removed efficiency $TCOD_{Cr}$ of the ASBR process is 83% resulted from the mean value of effluent $TCOD_{Cr}$, 9,125 mg/L during the start-up period. Then ASBRs were operated with F/R ratio of 0.024, 0.303 and 0.91 respectively. Organic loading rate was increased from 4.56 to $15.43gTCOD_{Cr}/L$-day to investigate the effects of F/R ratio and organic loading rate on the organic removal efficiency. As the result of the experiment, less than $6.23gTCOD_{Cr}/L$/L-day, F/R ratio haven't an effect on the organic removal efficiency and the mean removal efficiency of TSS, $TCOD_{Cr}$ and $SCOD_{Cr}$ was about 80%, 86% and 78% at the all of F/R ratio. But as organic loading rate was increased from 8.54 to $12.04gTCOD_{Cr}/L$-day at the F/R ratio of 0.024, the removal efficiency of $SCOD_{Cr}$ decreased from 71% to 63%. The range of decreased removal efficiency of $SCOD_{Cr}$ at the F/R ratio of 0.024 was much more higher than at the F/R ratio of 0.303, 0.91. Thus, as organic loading rate was increased, ASBRs were operated with high F/R ratio to obtain high removal efficiency.