• 제목/요약/키워드: F0 Range

검색결과 1,444건 처리시간 0.033초

역사 지진 피해 발생 읍성 지역의 부지 응답 특성 평가 (Estimation of Site Response Characteristics at Town Fortress Areas Damaged by Historical Earthquakes)

  • 선창국;방은석;정충기;김동수
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.125-132
    • /
    • 2006
  • To estimate the local site effects at two town fortress areas where stone parapets were collapsed during historical earthquakes, site characteristics were evaluated using borehole drillings and seismic tests and equivalent-linear site response analyses were conducted based on the shear wave velocity (Vs) profiles determined from site investigations. The study sites are categorized as site classes C and B according to the mean Vs to 30 m ranging from 500 to 850 m/s, and their site periods are distributed in short period range of 0.06 to 0.16 sec. For site class C in the study areas, the short-period (0.1-0.5 sec) and mid-period (0.4-2.0 sec) site coefficients, $F_{\alpha}$ and $F_\nu$ specified in the Korean seismic design guide, underestimate the ground motion in short-period band and overestimate the ground motion in mid-period band, respectively, due to the characteristics showing high amplification in short period range, which can result in the collapse of stone parapets having the short natural period.

  • PDF

도전성 카본블랙/PVdF 복합재의 제조 및 전기적 특성 (Fabrication and Electrical Properties of Conductive Carbon Black filled Poly(Vinyliden Fluoride) Composite)

  • 김명찬;문승환;임재석;함현식;박홍수;김명수
    • 한국응용과학기술학회지
    • /
    • 제20권3호
    • /
    • pp.212-220
    • /
    • 2003
  • Electrical properties of carbon filler/PVdF [poly(vinylidene fluoride)] composite were investigated as a funtion of carbon filler/PVdF ratio in the range of 0.2${\sim}$0.5. Three kinds of comercialzied conductive carbon blacks such as Hiblack 41Y, KE300J, and KE600J, and carbon nanofibers prepared by the catalytic chemical vapor deposition of $C_2H_4$ over Ni-Cu catalysts were used as the carbon fillers. The electrical conductivity of carbon filler/PVdF composites were in the range of 0.65 to 13.5 S/cm depending the fillers' electrical conductivity ranging from 5.6 to 23.1 S/cm. Among the carbon fillers used, the KE600J carbon black showed the highest conductivity both in the composite and filler itself because of its high degree of graphitization due to the high-temperature thermal treatment and its high surface area due to the activation treatment.

비자성 불순물을 갖는 $CuF_{2}.2H_{2}O$의 수소 핵자기완화 연구 ($^{1}H$ Nuclear Magnetic Relaxation in Impure $CuF_{2}.2H_{2}O$)

  • C. H. Lee;C. E. Lee;S. J. Noh
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.854-857
    • /
    • 1995
  • 비자성 분순물을 갖는 $CuF_{2}.2H_{2}O$의 수소 핵자기공명을 77-295 K의 온도범위에서 수행하였다. 그 결과 수소의 스핀-격자 완화율을 지배하는 메카니즘이 구리 전자 스핀의 재주넘기(filp)와 전자-포논 상호작용(Raman process)의 변조에 의한 것임을 알 수 있었다. 또한 전자 스핀 재주넘기에 대한 교환에너지 $1.8(\pm0.04)$ K를 구할 수 있었다.

  • PDF

Holstein과 교잡종 거세우 및 처녀우의 성장발육, 사료이용성 및 도체특성 비교 연구 (Study on Comparison of Growth Performance, Feed Efficiency and Carcass Characteristics for Holstein and F1(Holstein ♀ x Hanwoo ♂) Steers and Heifers)

  • 강수원;오영균;김경훈;최창원;손용석
    • Journal of Animal Science and Technology
    • /
    • 제47권4호
    • /
    • pp.593-606
    • /
    • 2005
  • Holstein 및 교잡종(Holstein♀×한우♂)의 거세우 및 처녀우 각 8두씩 총 32두(평균체중, Holstein 거세우:196.9±25.2kg, Holstein 처녀우:163.4±11.3kg, 교잡종 거세우:169.6±24.9kg, 교잡종 처녀우 156.9±15.6kg)를 대상으로 7개월령부터 24개월령까지 비육시험을 실시한 결과를 요약하면 다음과 같다. 성장단계별 일당증체량은 육성기, 비육전기, 비육중기 및 비육후기에 각각 0.733~1.018(평균 0.869), 0.994~1.255(평균 1.094), 0.947~1.259(평균 1.122) 및 0.736~0.824kg(평균 0.790kg)으로 비육중기>비육전기>육성기>비육후기의 순으로 높았다. 그러나 전 비육기간의 일당증체량은 0.882~1.061kg(평균 0.957kg)으로 순종이 교잡종보다 0.072kg(7.3%), 그리고 성별로는 거세우가 처녀우에 비해 0.106kg(10.5%)이 더 증체되었다. 전 비육기간의 농후사료 급여수준은 체중의 1.9% 내외이고, 볏짚은 농후사료 급여량의 25% 수준이 바람직한 것으로 나타났다. 그리고 1kg 증체에 소요된 농후사료 및 TDN량은 순종이 교잡종보다 4.6%가 많았으며, 처녀우가 거세우보다 7.3%가 많아 순종보다는 교잡종이, 그리고 처녀우보다 거세우의 사료이용성이 높았다. 도체조사 결과, 등지방두께는 순종이 교잡종보다 엷었고, 등심단면적은 순종이 교잡종보다 적었다. 도체중 1kg에 대한 등심단면적은 순종보다 교잡종이, 그리고 거세우보다 처녀우가 넓었다. 그리고 육색은 교잡종보다 순종이 우수하였으나 성별에 따른 뚜렷한 차이는 없었다. 쇠고기의 물리화학적 특성에서 전단력, 가열감량 및 보수력 등과 관능검사 결과의 다즙성, 연도 및 향미 등은 순종보다 교잡종이, 그리고 거세우보다 처녀우가 우수하였다. 이상과 같은 결과들을 종합해 볼 때, 고급육생산은 순종보다 교잡종이, 그리고 거세우보다 처녀우가 유리하고, Holstein 및 교잡종의 거세우 및 처녀우 비육시 농후사료는 체중의 1.9%, 볏짚은 농후사료 량의 25% 수준에서 결정하는 것이 바람직 할 것으로 판단된다.

가스발생기용 F-O-F 충돌형 인젝터 분사특성 (Atomization Characteristic of F-O-F Triplet Injector for Gas Generator)

  • 권순탁;이창진;김승한;한영민
    • 한국항공우주학회지
    • /
    • 제33권1호
    • /
    • pp.62-68
    • /
    • 2005
  • 액체로켓 가스발생기를 위한 인젝터를 설계하여 분사특성을 살펴보았다. 인젝터는 F-O-F triplet impinging이고 모의 추진제로 kerosene/물을 사용하였다. 인젝터의 형상설계 변수는 충돌각과 충돌거리이며 이를 이용하여 5가지의 후보 요소 인젝터를 설계하였으며, 모의 추진제를 사용하여 분사 특성을 실험하였다. 분사특성을 측정하기 위한 인자는 혼합효율과 분사각으로 모의 추진제 운동량비 0.2~1.3 범위에서 분사유량과 국부 O/F비를 측정하고 혼합효율을 계산하였다. 가스발생기용 인젝터는 농염한계의 O/F비 때문에 가장 높은 효율과 적절한 분사 각을 갖는 요소 인젝터를 선정하였고 연소 특성을 연구하기 위하여 연소실험을 실시하였다.

상완이두근과 대퇴사두근의 등장성 수축에 대한 EMG Amplitude의 비교${\cdot}$분석 (A Comparison of EMG Amplitude between the Biceps Brachii and the Quadriceps Femoris Muscles in Static Exertions)

  • 이구형;이면우
    • 한국국방경영분석학회지
    • /
    • 제8권1호
    • /
    • pp.77-98
    • /
    • 1982
  • Experiments have been performed for estimating the individual muscle capabilities of the biceps brachii and the quadriceps femoris muscle. The surface EMG has been recorded on the bellies of the biceps brachii and the quadriceps femoris muscle during isometric contractions at $50\%,\;75\%,\;and\;100\%$ MVC. The rectified EMG amplitudes of the maximum voluntary contraction (MVC) were in the range of $2.8\~3.0\;mV\;and\;6.9\~7.2\;mV$ the biceps brachii and the quadriceps femoris, respectively. In the biceps brachii, Type S motor units were recruited in the range of $41\~49\%$ MVC; and Type F motor units were recruited in the range of $51\~59\%$ MVC, In the quadriceps femoris, Type S, Type SF, and Type F motor units were recruited in the ranges of $31\~38\%,\;33\~48\%$, and $21\~29\%$ MVC respectively.

  • PDF

Broadband Instantaneous Frequency Measurement System Based on the Dual Paths of the Stimulated Brillouin Scattering Effect

  • Jiahong Zhang;Weijie Liao
    • Current Optics and Photonics
    • /
    • 제7권4호
    • /
    • pp.378-386
    • /
    • 2023
  • A wideband instantaneous frequency measurement (IFM) system is been proposed, designed and analyzed. Phase modulation to intensity modulation conversion is implemented based on the stimulated Brillouin scattering (SBS) effect, and the microwave frequency can be measured by detecting the change in output power. Theoretical analysis shows that the frequency measurement range can be extended to 4fb by adjusting the two sweeping signals of the phase modulators with a difference of 2fb. The IFM system is set up using VPI transmission maker software and the performances are simulated and analyzed. The simulation results show that the measurement range is 0.5-45.96 GHz with a maximum measurement error of less than 9.9 MHz. The proposed IFM system has a wider measurement range than the existing SBS-based IFM system.

PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가 (Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT)

  • 문아름;이혁;곽인석;최성욱;석재동
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.36-40
    • /
    • 2011
  • PET/CT 검사에서 환자에게 주입되는 $^{18}F$-FDG 투여량은 장비업체에서 제시하는 권고치와 각 병원에서 적용하는 기준치가 서로 다르다. 기준치의 차이로 인한 부적절한 $^{18}F$-FDG 투여량은 환자의 피폭선량을 증가시키고 영상의 질을 감소시킬 수 있다. 본 실험에서는 PET/CT 검사에서 영상의 질을 유지하면서 환자의 피폭선량을 감소시킬 수 있는 적정한 $^{18}F$-FDG 투여량에 대한 평가를 하고자 한다. 모형 실험은 NEMA NU2-1994를 이용하여 열소와 배후 방사능비를 4:1로 유지한 상태에서 열소의 방사능 농도를 1, 3, 5, 7, 9 MBq/kg으로 증가시키며 $^{18}F$-FDG를 주입하였다. CT를 이용한 투과촬영 후 2분 30초/bed의 방출영상을 3차원 (3D) 모드로 획득하였다. 열소와 배후방사능 부위에 각각 관심영역을 설정하고 최대 표준섭취계수(Standard Uptake Value maximum, $SUV_{max}$)를 얻은 후 해당 위치에서의 신호대 잡음비(Signal to Noise Ratio, SNR)를 비교 분석하였다. 임상실험은 2009년 11월부터 2010년 8월까지 내원한 환자를 대상으로 PET/CT 검사를 시행한 환자영상에서 간병변이 없는 97명의 환자를 선별하여 간(liver)과 대퇴부(thigh) 영역에 관심영역을 설정하고 $SUV_{max}$를 측정하여 투여량에 따른 영상의 차이를 비교 분석하였다. 모형 실험에서 단위 질량 당 주입된 방사능 농도는 1, 3, 5, 7, 9 MBq/kg으로 $SUV_{max}$는 23.1, 24.1, 24.3, 22.8, 23.6, SNR은 0.48, 0.54, 0.56, 0.55, 0.55로 나타났다. 5 MBq/kg 이하의 방사능 농도에서는 투여량의 증가에 따라 $SUV_{max}$와 SNR이 증가하지만 7 MBq/kg 이상에서는 감소하였다. 임상 실험의 경우는 단위 질량 당 주입된 방사능 농도가 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg으로 증가할수록 $SUV_{max}$는 2.68, 2.67, 2.26, 1.88, 1.95, SNR이 0.52, 0.53, 0.46, 0.46, 0.44로 5 MBq/kg의 투여량을 초과할 경우 모형 실험에서와 같은 감소양상을 보였다. 환자의 체중을 고려한 $^{18}F$-FDG 투여량의 증가는 일정 범위 내에서 영상의 질을 향상시키지만 그 범위를 초과할 경우 우발동시계수 및 산란계수의 증가로 인하여 오히려 영상의 질이 저하된다. 실험 결과로부터 3D PET/CT 검사 시 단위질량 당 주입된 방사능 농도 5 MBq/kg이 최적의 주입선량이라는 것을 알 수 있다.

  • PDF

수종목재부후균(數種木材腐朽菌)의 균사발육(菌糸發育)에 미치는 살균제(殺菌劑)의 영향(影響) (Effect of fungicides to mycelial growth of some wood destroying fungi)

  • 정대교
    • 한국산림과학회지
    • /
    • 제4권1호
    • /
    • pp.14-16
    • /
    • 1965
  • (1) The sterilizing effects of NaF, $CuSO_4$, $CuCO_3$, $HgCl_2$, $ZnSO_4$, and coaltar creosote on the mycelial growth of Irpex consors Berk. Polystictus versicolor L. Fr, Polystictus versicalor L. var. nigricans, and Schizophyllum commune Fr. Were studied. (2) The range of minimum density of the fungicides to check the growth of four fungi mentioned above was as follows; NaF 0.15~0.25(%) $CuSO_4$ 0.20~0.35(%) $CuCO_3$ 0.40~0.50(%) $HgCl_2$ 0.05(%) $ZnSO_4$ 0.40~0.45(%) Creosote 0.10~0.15(%) Of the fungicides tested, $HgCl_2$ was most effective in fungicidal effects, and Creosote, NaF, $CuSO_4$, $ZnSO_4$, $CuCO_3$, followed. The order of resistance of the fungi to the fungicides was as follows: S. Commune Fr. P. Versicalor L. var.nigricans I. Consors Berk P. Versicalor L. Fr. (3) The fungicides were added to the pepton-agor culture medium at the concentration between 0.01 and 0.5%, and the medium was filled into 9cm petridshes. Two square millimeter agar blocks prepared separately from the fungi Contained agar were placed in the middle of the Petri-dishes, in cubated six days at $26^{\circ}C$. Diameter of biggest Colonies were measured.

  • PDF

LiF(Mg,Cu,Na,Si)형광체의 열자극엑소전자방출 (Thermally Stimulated Exoelectron Emission from LiF(Mg,Cu,Na,Si) Phosphor)

  • 도시홍;정중현;청목정의;서천조웅;옥천양일;기부광효
    • 센서학회지
    • /
    • 제3권2호
    • /
    • pp.11-15
    • /
    • 1994
  • LiF(Mg,Cu,Na,Si)형광체의 ${\gamma}$ 선과 ${\beta}$ 선에 대한 TSEE 특성을 조사하였다. 이 형광체의 TSEE glow 곡선은 $20^{\circ}C$에서 $400^{\circ}C$사이에서 5개의 피크를 나타내었으며 주피크는 $240^{\circ}C$였다. $^{60}Co$ ${\gamma}$ 선에 대한 형광체의 감도는 약 450 counts/mR 이었다. ${\beta}$ 선에 대한 TSEE 에너지의존성은 ${\beta}$ 입자의 평균에너지 0.02MeV에서 0.8MeV 사이에서 ${\pm}10%$이었다. 그리고 이 형광체의 ${\beta}$ 선에 대한 TSEE 효율은 $(2{\sim}15){\times}10^{-3}$ 이었다.

  • PDF