• 제목/요약/키워드: F0 Range

검색결과 1,445건 처리시간 0.031초

Compact Zoom Lens Design for a 5x Mobile Camera Using Prism

  • Park, Sung-Chan;Lee, Sang-Hun;Kim, Jong-Gyu
    • Journal of the Optical Society of Korea
    • /
    • 제13권2호
    • /
    • pp.206-212
    • /
    • 2009
  • This study presents the compact zoom lens with a zoom ratio of 5x for a mobile camera by using a prism. The lens modules and aberrations are applied to the initial design for a four-group inner-focus zoom system. An initial design with a focal length range of 4.4 to 22.0 mm is derived by assigning the first-order quantities and third-order aberrations to each module along with the constraints required for optimum solutions. We separately designed a real lens for each group and then combined them to establish an actual zoom system. The combination of the separately designed groups results in a system that satisfies the basic properties of the zoom system consisting of the original lens modules. In order to have a slim system, we directly inserted the right-angle prism in front of the first group. This configuration resulted in a more compact zoom system with a depth of 8 mm. The finally designed zoom lens has an f-number of 3.5 to 4.5 and is expected to fulfill the requirements for a slim mobile zoom camera having high zoom ratio of 5x.

DFB 레이저의 통합된 설계 변수로서의 광자 분포 중심 II : ${\lambda}$/4 위상 천이 구조 (Center of Photon Mass as a Unified Design Parameter II : Quarter Wavelength Shifted DFB Lasers)

  • 김성한;김상배
    • 전자공학회논문지D
    • /
    • 제36D권12호
    • /
    • pp.63-69
    • /
    • 1999
  • QWS-DFB 레이저에서 단일 주파수 동작 안정성을 결정하는 문턱 이득 차이와 축 방향 광자 분포, 균일성을 동시에 나타내는 통합된 설계 변수로서 광자 분포 중심을 정의하고, 이 광자 분포 중심이 문턱 이득 차이와 광자 분포의 균일성과 어떻게 연관되는지를 유효 굴절률 전달 매트릭스 방법으로 보였다. 또, 이로부터 단일 주파수 동작 안정성을 최대화하는 설계 원칙을 제시하였다. 그리고 이 설계 원칙을 적용한 예로서 100% 단일 주파수 동작 수율을 보이는 결합계수의 범위를 넓힌 ,sampled grating QWS-DFB 레이저 구조를 제안하였다. 이 레이저 구조는 단일 주파수 동작을 하는 결합계수의 범위가 좁다는 QWS-DFB 레이저의 문제점을 해결하는 길을 제시하였다.

  • PDF

CF4, CH4, Ar 혼합기체의 전리와 부착계수 (Ionization and Attachment Coefficients in CF4, CH4, Ar Mixtures Gas)

  • 김상남
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.13-17
    • /
    • 2012
  • Ionization and Attachment Coefficients in pure $CH_4$, $CF_4$ and mixtures of $CF_4$ and Ar, have been analyzed over a range of the reduced electric field strength between 0.1 and 350[Td] by the two-term approximation of the Boltzmann equation (BEq.) method and the Monte Carlo simulation (MCS). The calculations of electron swarm parameters require the knowledge of several collision cross-sections of electron beam. Thus, published momentum transfer, ionization, vibration, attachment, electronic excitation, and dissociation cross-sections of electrons for $CH_4$, $CF_4$ and Ar, were used. The results of the Boltzmann equation and the Monte Carlo simulation have been compared with the data presented by several workers. The deduced transport coefficients for electrons agree reasonably well with the experimental and simulation data obtained by Nakamura and Hayashi. The energy distribution function of electrons in $CF_4$-Ar mixtures shows the Maxwellian distribution for energy. That is, f(${\varepsilon}$) has the symmetrical shape whose axis of symmetry is a most probably energy. The proposed theoretical simulation techniques in this work will be useful to predict the fundamental process of charged particles and the breakdown properties of gas mixtures.

세관내 액단상의 열전달과 압력강하에 관한 연구 (The Heat Transfer and Pressure drop Characteristics of R7l8 in Small Diameter Tubes)

  • 김세웅;홍진우;손창효;노건상;오후규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 추계학술대회 논문집(Proceeding of the KOSME 2001 Autumn Annual Meeting)
    • /
    • pp.28-35
    • /
    • 2001
  • The heat transfer and pressure drop characteristics of R718 flowing in smooth horizontal copper tubes with inner diameter of 3.36 mm, 5.35 mm, 6.54 mm and 8.12 mm were investigated. The test section is a counterflow heat exchanger with refrigerant flowing in the inner tube and water flowing in the annulus. Experiments were peformed for the flowing range of variables : Reynolds number (1000 to 20000), mass flow rate of brine (450 kg/h) and refrigerant temperature (5$0^{\circ}C$). The main results were summarized as follows : (1) The heat transfer coefficient of 3.36 mm ID was about 10% to 30% higher than that of 5.35 mm, 6.54 mm and 8.12 mm ID, and the heat transfer coefficients for small diameter. tubes are about 20% to 27% higher than these predicted by Gnielinski. The new correlation is proposed to predict the experimental data. (2) As a result of comparison with correlation prosed by Blasius. the deviation of the experimental data slightly increased as the tube diameter decreased. (3) The ratio of heat transfer to friction factor (j/f) correlated by all experimental data increased as the tube diameter decreased.

  • PDF

광수신기 설계 (Optical receiver design)

  • 한창용;김규철
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2005년도 춘계학술발표대회
    • /
    • pp.1641-1644
    • /
    • 2005
  • 현재의 인터넷과 같은 전자 통신망과 멀티미디어 시스템의 발달은 고속의 대용량 데이터 전송을 필요로 한다. 초고속 통신 시스템에서의 고속 데이터 전송은 주로 광섬유를 사용하는 광통신으로 이루어지고 있다. FTTH(Fiber To The Home)와 같은 광통신 시스템은 멀티미디어 커뮤니케이션을 위해 필요한 큰 데이터 전송률을 제공할 수 있기 때문에 더욱 더 중요성이 높아지고 있으며 이러한 광통신 시스템에서는 통신환경의 영향을 적게 받고 외부 조절이나 부품이 필요하지 않는 수신기 IC 의 개발이 요구되고 있다. 일반적으로 광통신 수신기에는 고속 동작에 적합한 특성을 가진 GaAs-MESFET 가 사용되고 있으나, 본 논문에서는 0.35um CMOS 2-poly 4-metal 공정을 이용하여 5Gbps 광수신기를 설계하였다. 설계된 수신기는 Preamplifier, Main amplifier, ABC 회로로 구성되어 있다. Transimpedance amplifier 형태의 Preamplifier 는 광검출기에 의해 생성된 전류 신호를 전압 신호로 변환한다. ABC 회로는 Peak_Hold 회로와 Bottom_Hold 회로로 구성되어 있다. 기존의 Peak_Hold 회로에서는 다이오드와 hold capacitor 를 이용하여 peak 값을 검출하도록 되어 있는데, 다이오드를 이용하는 경우 작은 입력 신호전압의 Peak 값을 검출하는 데 한계가 있다. 이러한 단점을 보완하고자 전류 거울형태의 Peak_Hold 회로를 설계하였다. 전류거울(current mirror)형태의 출력 신호의 duty error 를 줄이고 비트 에러율(Bit Error Rate)을 개선하는데 효과적이었다. 설계된 광수신기는 30dB 의 입력 dynamic range 와 입력 capacitance 3pF 에서 80MHz 의 대역폭을 가진다. 전력 소비량은 3.3V 전원 전압이 인가된 경우 약 150mW 정도이다.

  • PDF

직접토크제어에 의한 리럭턴스 동기전동기의 고성능 위치제어 시스템 (A High-Performance Motion Control System of Reluctance Synchronous Motor with Direct Torque Control)

  • 김민회;김남훈;최경호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권3호
    • /
    • pp.150-157
    • /
    • 2002
  • This paper presents preliminarily an implementation of digital high-performance motion control system of Reluctance Synchronous Motor (RSM) drives with direct torque control (DTC). The system consist of stator flux observer, torque estimator, two hysteresis band controllers, an optimal switching look-up table, IGBT voltage source inverter, and TMS320F240 DSP controller made by Texas Instruments. The stator fluff observer is based on the combined voltage and current model with stator flux feedback adaptive control, and the input of the observer are the stator voltage and current of motor terminal for wide speed range. The rotor position and speed sensor used 6000 pulse/rev encoder. In order to prove rightness of the suggested control algorithm, we have some simulation and actual experimental system at $\pm$20 and $\pm$2000 rpm. The developed digitally high-performance motion control system+ are shown a good response characteristic of control results and high performance features using 1.0kW RSM which has 2.57 Ld/Lq salient ratio.

글로벌 모델에 의한 저온 고밀도 플루오로카본 플라즈마 특성의 공정변수 의존성 해석 (Analysis of Process Parameter dependency on the characteristics of high density fluoro carbon plasma using global model)

  • 이호준;태흥식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.879-881
    • /
    • 1999
  • Radical and ion densities in a CF4 plasma have been calculated as a function of input power density. 9as pressure and feed gas flow rate using simple 0 dimensional global model. Fluorine atom is found to be the most abundant neutral particle. Highly fragmented species such as CF and CF+ become dominant neutral and ionic radical at the high power condition. As the pressure increases. ion density increases but ionization rate decreases due to the decrease in electron temperature. The fractional dissociation of CF4 feed gas decreases with pressure after increasing at the low pressure range. Electron density and temperature are almost independent of flow rate within calculation conditions studied. The fractional dissociation of CF4 monotonically decreases with flow rate. which results in increase in CF3 and decrease in CF density. The calculation results show that the SiO2 etch selectivity improvement correlates to the increase in the relative density of fluorocarbon ion and neutral radicals which has high C/F ratio.

  • PDF

Search for Gravity Waves with n New All-sky Camera System

  • Kim, Yong-Ha;Chung, Jong-Kyun;Won, Yong-In;Lee, Bang-Yong
    • Ocean and Polar Research
    • /
    • 제24권3호
    • /
    • pp.263-266
    • /
    • 2002
  • Gravity waves have been searched for with a new all-sky camera system over Korean Peninsular. The all-sky camera consists of a 37mm/F4.5 Mamiya fisheye lens with a 180 dog field of view, interference filters and a 1024 by 1024 CCD camera. The all-sky camera has been tested near Daejeon city, and moved to Mt. Bohyun where the largest astronomical telescope is operated in Korea. A clear wave pattern was successfully detected in OH filter images over Mt. Bohyun on July 18, 2001, indicating that small scale coherent gravity waves perturbed OH airglow near the mesopause. Other wave features are since then observed with Na 589.8nm and OI 630.0nm filters. Since a Japanese all-sky camera network has already detected traveling ionospheric disturbances (TID) over the northeast-southwest range of Japanese islands, we hope our all-sky camera extends the coverage of the TID's observations to the west direction. We plan to operate our all-sky camera all year around to study seasonal variation of wave activities over the mid-latitude upper atmosphere.

연축성 발성장애 환자의 Lax Vox 음성치료 효과 (Effects of Lax Vox voice therapy in a patient with spasmodic dysphonia: A case report)

  • 임혜진;최성희;김정규;최철희
    • 말소리와 음성과학
    • /
    • 제8권2호
    • /
    • pp.57-63
    • /
    • 2016
  • Recently, the Lax Vox voice therapy has been used as one of the SOVTE(Semi-Occluded Vocal Tracts Exercise). The purpose of this study was to explore the effect of Lax Vox voice therapy for a patient with Spasmodic dysphonia on voice improvement. One female spasmodic dysphonia patient(age=27) who had been diagnosed by a laryngologist received Lax Vox voice therapy. The Lax Vox protocol was configured as 5 steps (1 warm-up and 4 steps : bubbling without / with phonation/ gliding with phonation/ generalization) in this study. A total of 11 sessions were performed by a certified speech language pathologist. The present study evaluated the acoustic, aerodynamic, auditory perceptual, and patient's self-rating between pre-, mid-, and post- voice therapy. All objective and subjective parameters were improved after voice therapy; Reduced frequency variation, increased maximum phonation time, enlarged voice range, improved 'G' and 'S' in GRBAS & USDRS, and reduced VHI were observed. Especially, decreased $f_0$ and remarkably reduced voice tremor were also demonstrated following Lax Vox voice therapy. Accordingly, Lax Vox voice therapy technique can be useful for improving voice and quality of life in patients with spasmodic dysphonia.

DESIGN CONCEPT FOR THE RETROFIT KAO 1M ROBOTIC TELESCOPE

  • Han, Won-Yong;Mack, Peter;Park, Jang-Hyun;Jin, Ho;Lee, Woo-Baik;Lee, Chung-Uk
    • Journal of Astronomy and Space Sciences
    • /
    • 제17권2호
    • /
    • pp.211-220
    • /
    • 2000
  • Korea Astronomy Observatory(KAO) is working to retrofit its 1m robotic telescope in collaboration with a company (ACE, Astronomical Consultants & Equipment). The telescope system is being totally refurbished to make a fully automatic telescope which can operate in both interactive and fully autonomous robotic modes. Progress has been made in design and manufacturing of the telescope mount, mechanics, and optical performance system tests are being made for re-configured primary and secondary mirrors. The optical system is designed to collect 80% incident light within 0.5 arcsec with f/7.5 Ritchey-Chretien design. The telescope mount is an equatorial fork with a friction drive system. The design allows fully programmable tracking speeds with typical range of 15 arcsec/sec with accuracy of $\pm5$ arcsec/hour. The mount system has integral pointing model software to correct for refraction, and all mechanical errors and misalignments. The pointing model will permit positioning to better than 30 arcsec RMS within $75^{\circ}$ from zenith and 45 arcsec RMS elsewhere on the sky. The software is designed for interactive, remote and robotic modes of operation. In interactive and remote mode the user can manually enter coordinates or retrieve them from a computer file. In robotic mode the telescope controller downloads the coordinates in the order determined by the scheduler. The telescope will be equipped with a CCD camera and will be accessible via the internet.

  • PDF