• Title/Summary/Keyword: F-V curve

Search Result 94, Processing Time 0.033 seconds

Sustained Oscillation of an Inverter-Fed Induction Motor Drive System and its Stabilization

  • Li Hongmei;Hikihara Takashi
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.80-84
    • /
    • 2006
  • The sustained oscillation of rotor speed is often experienced in PWM inverter induction motor (IM) drive systems. In this paper the oscillation is investigated from the point of view of Hopf bifurcation theory. The sufficient and necessary conditions for existence of limit cycle are introduced to determine the bifurcation set in the stator voltage versus stator frequency plane. According to the conditions it is clarified that the bifurcation set inherently exists in the instable operation of IM. Moreover, it is numerically shown that the V/f curve can be adjusted to stabilize the sustained oscillation of rotor speed.

A Study on Enhancing the Total Transfer Capability from Voltage Stability Point of View Using UPFC (IPLAN을 이용한 UPFC 적용 전력시스템의 전압 안정도 측면에서의 융통전력 향상 효과 분석)

  • Lee, S.J.;Lee, B.H.;Kim, J.H.;Kim, Y.H.;Kwak, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.151-153
    • /
    • 2002
  • Using UPFC(Unified Power Flow Controlled), it is possible to control three parameters(voltage, impedance, and phase angle). The UPFC can generate or absorb reactive power rapidly so as to enhance the transient and voltage stability and also influence the power flow. In this paper, the effects of application of the UPFC to the power system are analyzed from a viewpoint of improving the total transfer capability by enhancing voltage stability. The IPLAN, which is a high level language used with PSS/E program, is employed for evaluating the total transfer capability from a f-V curve.

  • PDF

A Study on Planarized Formation of Inter-Level Dielectric Films by Laser CVD Method (Laser CVD법에 의한 평탄화 층간 절연막 형성에 관한 연구)

  • Lee, K.S.;Park, G.Y.;Lee, H.S.;Houng, S.H.;Huh, Y.J.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1271-1273
    • /
    • 1993
  • $SiO_2$ and SiON films are formed by Laser CVD for inter-level dielectrics in submicron VLSI. This technique is noticeable that film formation can be done at low temperatures, below $300^{\circ}C$ with less damage. An ArF Excimer Laser with wave length of 193nm is used to excite and dissociate reactant gases. After film formation growth rate, refractive index, I-V curve, and step coverage characteristics of the films were evaluated.

  • PDF

Photoelectric Properties of PbTe/CuPc Bilayer Thin Films (PbTe/CuPc 이층박막의 광전 특성)

  • Lee, Hea-Yeon;Kang, Young-Soo;Park, Jong-Man;Lee, Jong-Kyu;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • The crystallized CuPc and PbTe films are formed by thermal evaporation and pulsed ArF excimer laser ablation. Structural and electrical properties of thin film is observed by XRD and current-voltage(I-V) curves. From XRD analysis, both PbTe and CuPc thin films show a-axis oriented structure. For the measurement of photovoltaic effect, the transverse current-voltage curve of CuPc/Si, PbTe/Si and PbTe/CuPc/Si junctions have been analyzed in the dark and under illumination. The PbTe/CuPc/Si junction exthibits a strong photovoltaic characteristics with short circuit current($J_{sc}$) of $25.46\;mA/cm^{2}$ and open-circuit voltage($V_{oc}$) of 170 mV. Quantum efficiency and power conversion efficiency are calculated to be 15.4% and $3.46{\times}10^{-2}$, respectively. Based on the results of QE and ${\eta}$, the photocurrent process of PbTe/CuPc/Si junction can be explained as following three effective steps; photocarrier generation in the CuPc layer, carrier separation at PbTe/CuPc interface, and finally a transportation of electrons through the PbTe layer.

  • PDF

Electrochemical Characteristics of EDLC Fabricated by Different Preparation Processes of Activated Carbon Electrode (활성탄소 전극의 제조공정에 따른 EDLC의 전기화학적 특성)

  • Yang Chun-Mo;Kim H.J.;Cho W.I.;Cho B.W.;Yun K.S.;Rim Byung-O
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.98-103
    • /
    • 2001
  • The electrochemical characteristics and specific capacitance were investigated by preparation processes (dip coating method, doctor blade coating method and paste rolling method) of activated carbon electrode for an EDLC(electric double layer capacitor). The EDLC using $LiPF_6$ salts and PC-DEC solvents showed good specific capacitance, 130F/g and small IR-drop at linear time-voltage curve. 0.11V, Cyclic voltammetry analysis using the activated carbon electrode prepared by dip coating method was shown closer to ideal EDLC characterization.

Luminescence in SrCl2:Eu2+,Na+ X-ray Storage Phosphor (SrCl2:Eu2+,Na+ X-선 영상저장 형광체의 발광특성)

  • Kim, Sung-Hwan;Kim, Wan;Kang, Hee-Dong;Doh, Sih-Hong;Seo, Hyo-Jin;Kim, Young-Kook;Kim, Do-Sung
    • Korean Journal of Materials Research
    • /
    • v.13 no.6
    • /
    • pp.343-346
    • /
    • 2003
  • Photoluminescence(PL), photostimulated luminescence(PSL) and thermoluminescence(TL) in $SrC1_2$:$Eu^{2+}$ , $Na^{+}$ phosphor powder were measured, and the activation energies(trap depth) of traps associated with TL and PSL were investigated. The PL and PSL in the studied sample is due to the $4f^{6}$ 5d\longrightarrow$4f^{7}$transition of $Eu^{ 2+}$. TL glow curve is single peak, and its peak temperature is about 377.2 K. The PL, PSL and TL emission spectra of the phosphors are located in the range of 380∼440 nm, peaking at 408 nm. The activation energy of the PSL trapping center is 0.78 eV and that of the TL trapping center is 0.79 eV. We, thus, suggest that the trapping centers giving rise to the PSL are identical to those giving rise to the TL.

Growth Performances and Physiological Responses of Quercus spp. and Fraxinus rhynchophylla Subjected to Different Soil Moisture Regimes and Nutrition Levels (수분(水分) 및 양료(養料) 처리(處理)에 따른 참나무류와 물푸레나무의 생장 및 생리 반응)

  • Kwon, Ki Won;Lee, Jeoung Ho
    • Journal of Korean Society of Forest Science
    • /
    • v.83 no.2
    • /
    • pp.164-174
    • /
    • 1994
  • Temporal changes in growth performances, chlorophyll contents, and tissue water relations for determining their physiological responses of five economic tree species subjected to chronic water and nutrition stresses were investigated with containerized seedlings grown in different soil moisture regimes and nutrition levels. Seedlings of Quercus acutissima, Q. variabilis, Q. mongolica, Q. serrata, and Fraxinus rhynchophylla were propagated in plastic pots(I.D. $16cm{\times}Depth$ 16cm) for the experiments. The seedlings were subjected to two soil moisture regimes of dry and wet soils and two nutrition levels of fertilization with N+P+K and no fertilization through the growing season from May to September in a green house. For the purpose of analyzing their responses to the environmental stresses, seedling heights and root collar diameters, chlorophyll contents, and P-V curve parameters of the seedlings were measured in May, July, and September. The environmental stresses coming from moisture and nutrient deficits affected the growth performances of seedlings variously among species and among different growing periods, as well as between height and basal diameter growth of seedlings. The growth performances of Q. acutissima were influenced sensitively on the stresses, but those of Q. mongolica less influenced in comparison with other species. Chlorophyll contents were generally higher in Quercus spp. than F. rhynchophylla through the growing season. The chlorophyll contents changed by species and by treatment through the season within ranges of 0.14~1.96 mg/g dry wt. of chlorophyll a and within 0.16~1.79mg/g dry wt. of chlorophyll b, respectively. But the contents seemed to be decreased gradually through the chronic environmental stresses and leaf senescence. The osmotic potential at full turgor(${\Psi}{{\pi}o}$) and turgor loss point(${\Psi}{\pi}p$) had temporarily declined up to 3 to 5bars from -7.0~-12.4bars in May to -10.2~-17.5bars in September and up to 5 to 6bars from -7.6~-14.2bars in May to -12.9~-20.4bars in September, respectively, with some exceptions. The values of ${\Psi}{\pi}p$ were generally high in F. rhynchophylla in May and July, but high in Q. serrata in September. Relative water contents at turgor loss point(RWCp) were generally high in F. rhynchophylla, but the temporal changes of RWCp were quite and frequently different among species and among treatment.

  • PDF

Evaluation of the Radiopacity of Contemporary Luting Cements by Digital Radiography (디지털방사선촬영술을 이용한 합착용 시멘트의 방사선불투과성 평가)

  • An, Seo-Young;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.377-383
    • /
    • 2013
  • This study examined the radiopacity of eight contemporary luting cements by direct digital radiography. Five disc-shaped specimens ($5mm{\times}1mm$) were prepared for each material tested (BisCem, Clearfil SA Luting, Duolink, Maxcem Elite, Multilink Speed, Panavia F 2.0, RelyX Unicem Clicker, V-link). The specimens were radiographed using a Kodak CS 7600 image plate (Carestream Health, Inc., Rochester, NY, USA) and an aluminum step wedge with a range of thicknesses (1.5 to 16.5 mm in 1.5 mm increments) and a 1 mm tooth used as a reference. A dental X-ray machine Kodak 2200 Intraoral X-ray System (Carestream Health, Inc., Rochester, NY, USA), operating at 70 kVp, 4 mA, 0.156 s and a source-to-sample distance of 30 cm, was used. According to international standards, the radiopacity of the specimens was compared with that of an aluminum step wedge using NIH ImageJ software (available at http://rsb.info.nih.gov/ij/).The data was analyzed by ANOVA and a Tukey's post hoc test. Maxcem Elite (5.66) showed the highest radiopacity of all materials, followed in order by Multilink Speed (3.87) and V-link (2.83). The radiopacity of Clearfil SA Luting (1.35), BisCem (1.33), Panavia F 2.0 (1.29) and Duolink (1.10) were between enamel (1.79) and dentin (0.19). RelyX Unicem Clicker (0.71) showed the lowest radiopacity, which was higher than that of dentin. All materials showed a radiopacity above the minimum recommended by the International Organization for Standardization and the American National Standards/American Dental Association with the exception of RelyX Unicem Clicker.

Behavior of Fire Resistance Engineered Cementitious Composites(FR-ECC) under Fire Temperature (화재 온도를 받는 고인성.고내화성 시멘트 복합체의 거동)

  • Han, Byung-Chan;Kwon, Young-Jin;Kim, Jae-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.189-197
    • /
    • 2007
  • Concrete tunnel lining must be designed to having the fireproof performance because the lining are sometimes exposed to very high temperature due to traffic accident. Such fire temperature may cause explosion of concrete, or collapse of tunnel structure. The purpose of this study is to obtain the fundamental fireproof behavior of fire resistance-engineered cementitious composites(FR-ECC) under fire temperature in order to use the fire protection material in tunnel lining system. The present study conducted the experiment to simulate fire temperature by employing 2 types of FR-ECC and investigated experimentally the explosion and cracks in heated surface of these FR-ECC. Employed temperature curve were hydro carbon(HC, ECl) criterion, which are severe in various criterion of fire temperature. The numerical analysis is carried out the nonlinear transient heat flow analysis and verified against the experimental data. The complex features of behavior in fire conditions, such as thermal expansion, plasticity, cracking or crushing, and material properties changing with temperature are considered. By the use of analytical model, the concrete tunnel subjected to fire loads were analyzed and discussed. With comparison of current concrete materials and FR-ECC, the experimental and analytical results of FR-ECC shows the better fire resistance performance than the other.

Transfer Force Characteristics of Seedling Bed Transfer Equipment Using Pneumatic Cylinder for Automation of Plant Factory (식물공장 자동화를 위한 공압 실린더를 이용한 육묘베드 이송장치의 이송력 특성)

  • Min, Young-Bong;Park, Sang-Min;Lee, Gong-In;Kim, Dong-Ouk;Kang, Dong-Hyun;Moon, Sung-Dong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.155-165
    • /
    • 2012
  • This study was performed to offer the data for design of the seedling bed transfer equipment to make the automation of working process in a plant factory. The seedling bed transfer equipment pushing the seedling bed with bearing wheels on the rail for interconnecting each working process by a pneumatic cylinder was made and examined. The examined transfer force to push the seedling bed with a weight of 178.9 N by the pneumatic cylinder with length of 60 cm and section area of 5 $cm^2$ was measured by experiments. The examined transfer forces was compared with theoretical ones calculated by the theoretical formula derived from dynamic system analysis according to the number of the seedling bed and pushing speed of the pneumatic cylinder head at no load. The transfer function of the equipment with the input variable as the pushing speed $V_{h0}$(m/s) and the output variable as the transfer force f(t)(N) was represented as $F(s)=(V_{h0}/k)(s+B/M)/(s(s^2+Bs/M+1/(kM))$ where M(kg), k(m/N) and B(Ns/m) are the mass of the bed, the compression coefficient of the pneumatic cylinder and the dynamic friction coefficient between the seedling bed and the rail, respectively. The examined transfer force curves and the theoretical ones were represented similar wave forms as to use the theoretical formular to design the device for the seedling bed transfer. The condition of no vibration of the transfer force curve was $kB^2>4M$. The condition of transferring the bed by the repeatable impact and vibration force according to difference of transfer distance of the pneumatic cylinder head from that of the bed was as $Ce^{-\frac{3{\pi}D}{2\omega}}<-1$, where ${\omega}=\sqrt{\frac{1}{kM}-\frac{B^2}{4M^2}}$, $C=\{\frac{\frac{B}{2M}-\frac{1}{kB}}{\omega}\}$, $D=\frac{B}{2M}$. The examined mean peak transfer force represented 4 times of the stead state transfer force. Therefore it seemed that the transfer force of the pneumatic cylinder required for design of the push device was 4Bv where v is the pushing speed.