• Title/Summary/Keyword: F-V characteristics

Search Result 641, Processing Time 0.026 seconds

Study on TSD Characteristics of LiF ( Mg , Cu , P ) Single Crystal (LiF ( Mg , Cu , P ) 단결정의 TSD 특성에 관한 연구)

  • 도시홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.1
    • /
    • pp.8-13
    • /
    • 1990
  • The microscopic relaxation parameters for the single crystal were measured by using thermally stimulated depolarization (TSD). Initial rise method, various heating rate method and total glow peak method were used for the determination of the activation energy and Debye relaxation time from TSD glow curves. Activation energy, pre-exponential factor and relaxation time for impurity-vacancy dipole reorientation were 0.55eV, 1.97$\times$10 super(-12) sec and 12.19sec in average, respectively. Dielectric dissipation factor for the crystal was calculated from the measured TSD glow curve, its value being about 3$\times$10 super(-2).

  • PDF

Electrical and Optical Characteristics in Organic Electroluminescent Devices with Different Materials for Electron Injection

  • Cho, Min-Jeong;Park, wan-Ji;Lim, Min-Su;Cheol-Hyun park;Jeon-Gu lee;Lim, Kee-Joe;Park, Soo-Gil;Kim, Hyun-Hoo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.2
    • /
    • pp.37-41
    • /
    • 2001
  • In this study, organic electroluminescent devices with the ITO/TPD/Alq$_3$/cathode structure, using various materials of Al, Mg:Ag, Al:Li, MgF$_2$/Al, and LiF/Al as cathodes, were fabricated. We investigated the electrical and optical properties of the devices as follow: current density-voltage(J-V), luminance-voltage(L-V) and luminous efficiency-voltage curves. The bilayer cathodes with LiF/Al and MgF$_2$/Al exhibited better device performance than the other cathodes. It is considered that the improved performance of the organic electroluminescent devices is attributable to the lowering of driving voltage caused by the enhanced electron injection. The alkaline-earth fluorides are desirable materials to improve the performance of the EL devices with the Al cathode, and high luminous efficiency was achieved.

Dosimetric Properties of LiF:Mg,Cu,Na,Si TL pellets (LiF:Mg,Cu,Na,Si TL 소자의 선량계적 특성)

  • Nam, Young-Mi;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets were developed for application in radiation dosimetry. In the present study, the TL dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets have been investigated for emission spectrum, dose response, energy response, and fading characteristics. LiF:Mg,Cu,Na,Si TL pellets were made by using a sintering process, that is, pressing and heat treatment from TL powders. Photon irradiations for the experiments were carried out using X-ray beams and a $^{137}Cs$ gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and $10^{-6}-10^{-2}\;Gy$, respectively. The glow curves were measured with a manual type TLD reader(System 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of $5^{\circ}C\;s^{-1}$, the main dosimetric peak of glow curve appeared at $234^{\circ}C$, the activation energy was 2.34 eV and frequency factor was $1.00{\times}10^{23}$. TL emission spectrum is appeared at the blue region centered at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to $^{137}Cs$ response were within ${\pm}20%$ at overall photon energy region. The fading of TL sensitivity of the pellets stored at the room temperature was not found for one year.

  • PDF

Noise Characteristics of Readout Electronics for 64-Channel DROS Magnetocardiography System (64채널 DROS 심자도 시스템을 위한 검출 회로의 잡음 특성)

  • Kim J. M.;Kim K. D.;Lee Y. H.;Yu K. K.;Kim K. W.;Kwon H. C.;Sasada Ichiro
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.46-51
    • /
    • 2005
  • We have developed control electronics to operate flux-locked loop (FLL), and analog signal filters to process FLL outputs for 64-channel Double Relaxation Oscillation SQUID (DROS) magnetocardiography (MCG) system. Control electronics consisting of a preamplifier, an integrator, and a feedback, is compact and low-cost due to larger swing voltage and flux-to-voltage transfer coefficients of DROS than those of dc SQUIDs. Analog signal filter (ASF) serially chained with a high-pass filter having a cut-off frequency of 0.1 Hz, an amplifier having a gain of 100, a low-pass filter of 100 Hz, and a notch filter of 60 Hz makes FLL output suitable for MCG. The noise of a preamplifier in FLL control electronics is $7\;nV/{\surd}\;Hz$ at 1 Hz, $1.5\;nV/{\surd}\;Hz$ at 100 Hz that contributes $6\;fT/{\surd}\;Hz$ at 1 Hz, $1.3\;fT/{\surd}\;Hz$ at 100 Hz in readout electronics, and the noise of ASF electronics is $150\;{\mu}V/{\surd}\;Hz$ equivalent to $0.13\;fT/{\surd}\;Hz$ within the range of $1{\sim}100\;Hz$. When DROSs are connected to readout electronics inside a magnetically shielded room, the noise of 64-channel DROS system is $10\;fT/{\surd}\;Hz$ at 1 Hz, $5\;fT/{\surd}\;Hz$ at 100 Hz on the average, low enough to measure human MCG.

  • PDF

Design and fabrications of AlGaAs/InGaAs/GaAs Power PHEMT (AlGaAs/InGaAs/GaAs Power PHEMT 설계.제작)

  • 이응호;조승기;윤용순;이일형;이진구
    • Proceedings of the IEEK Conference
    • /
    • 2000.06b
    • /
    • pp.12-15
    • /
    • 2000
  • In this paper, we have fabricated the PHEMT's with AlGaAs/InGaAs/GaAs and measured characteristics of DC and frequencies. The PHEMT's has a 0.35$\mu\textrm{m}$ gate length, gate width of 60$\mu\textrm{m}$ and 80$\mu\textrm{m}$, and fingers of 2 and 4. From the measurements results for the 60$\mu\textrm{m}$ ${\times}$ 2 PHEMT's, we obtained 1.2V of Vk, -3.5V of Vp, 46mA of Idss, 221mS/mmof gm, and 3.6dB of S$\sub$21/ gain, 45GHz of f$\sub$T,/ 100GHz of fmax. And, in case of 80$\mu\textrm{m}$ ${\times}$ 4 PHEMT's, we obtained 1.2V of Vk, -4.5V of Vp, 125mA of Idss, 198mS/mm of gm, and 2.0dB of S$\sub$21/ gain. 44GHz of f$\sub$T/, 70GHz of fmax at 35GHz frequency. Also, MAG are decreased as a number of finger are Increased.

  • PDF

Evaluation of Inflammation Parameters in Philadelphia Negative Chronic Myeloproliferative Neoplasia Patients

  • Hacibekiroglu, Tuba;Akinci, Sema;Basturk, Abdulkadir;inal, Besime;Guney, Tekin;Bakanay, Sule Mine;Dilek, Imdat
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.13
    • /
    • pp.5159-5162
    • /
    • 2015
  • Background: Chronic myeloproliferative diseases are clonal stem cell diseases which occur as a result of uncontrollable growth and reproduction of hematopoietic stem cells, which are the myeloid series source in bone marrow. Recent studies have suggested that chronic inflammation can be a triggering factor in the clonal change in chronic myeloproliferative neoplasia (CMPN). In our study, we evaluated the existence of a chronic inflammation process in our Philadelphia negative (Ph-)CMPN patients using inflammation parameters in combination with demographic, laboratory and clinical characteristics of the patients. Materials and Methods: Demographic characteristics, clinical and laboratorial data, and thrombosis histories of 99 Ph-CMPN patients, who were diagnosed at our outpatient clinic of hematology in accordance with WHO 2008 criteria, were analyzed retrospectively,with 80 healthy individuals of matching gender and age included as controls. Complete blood counts, sedimentation, C reactive protein (CRP), JAK V617F gene mutations, abdomen ultrasound images and previous thrombosis histories of these patients were retrospectively analyzed. Results: Ph-CMPN and healthy control groups included 99 and 80 cases, respectively. PV, ET and MF diagnoses of patients were 43 (%43.4), 44 (44.4%) and 12 (12.1%), respectively. JAK V617F gene mutation was found to be positive in 64 (71.1%) of all cases and in 27(65.8%), 32 (82%), 5 (50%) of the cases in PV, ET and PMF groups, respectively. Thrombosis was determined as 12 (12%) in the entire group, 12.5% in the JAK V617F negative and 15.3% in the positive patients, with no statistical significance (p=0.758). No significant difference was observed between patients with and without previous thrombosis history in respect to hemogram parameters, sedimentation and CRP (p>0.05), neutrophil to lymphocyte ratio (NLR), erythrocyte distribution width (RDW), mean platelet volume (MPV) and sedimentation levels of the patient.

The Variation of Silicon Characteristic with Radiation Damage Effects (Radiation 손상에 기인한 실리콘 특성변화)

  • 장기현
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.4
    • /
    • pp.26-32
    • /
    • 1978
  • For a long life photovoltaic cell the degradation of the device characteristics with 1 MeV electron radiation must be known so as to be able to predict the life of the cell. Hence, a study was made of radiation damage effects on the bulk properties of the silicon crystal. From the results of the data, it is concluded that there appeared to be a steads rotate damage level reached in f type material.

  • PDF

NEW OPTICAL TECHNIQUES FOR THE 'STRUVE' SPACE ASTROMETRIC PROJECT

  • YERSHOV V. N.;TSUKANOVA G. I.;STARICHENKOVA V. D.;ZAKHARENKOV G. F.;GRIAZNOV G. M.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.425-426
    • /
    • 1996
  • A few optical schemes for the future Russian astrometric satellite ('Struve') are discussed. New optical materials and techniques developed at the Vavilov State Optical Institute are planned to be used for the on-board telescopes. Optical characteristics of the reflecting Schmidt and a three - mirror scheme for the on-board telescopes are compared.

  • PDF

1/f Noise Characteristics of Sub-100 nm MOS Transistors

  • Lee, Jeong-Hyun;Kim, Sang-Yun;Cho, Il-Hyun;Hwang, Sung-Bo;Lee, Jong-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2006
  • We report 1/f noise PSD(Power Spectrum Density) of sub-100 nm MOSFETs as a function of various parameters such as HCS (Hot Carrier Stress), bias condition, temperature, device size and types of MOSFETs. The noise spectra of sub-100 nm devices showed Lorentzian-like noise spectra. We could check roughly the position of a dominant noise source by changing $V_{DS}$. With increasing measurement temperature, the 1/f noise PSD of 50 nm PMOS device decreases, but there is no decrease in the noise of NMOS device. RTN (Random Telegraph Noise) was measured from the device that shows clearly a Lorentzian-like noise spectrum in 1/f noise spectrum.

An Analysis of the Relationship between Surface Profile Error of f-$\theta$Lens and Optical Performance (f-$\theta$렌즈 표면형상오차와 광학적 성능과의 연관성 분석)

  • Kim, Dong-Sik;Lee, In-Yong;Kim, Hyeong-Chae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.90-95
    • /
    • 2001
  • f-$\theta$len is one of the important parts in Laser Scanning Unit because it affects on the optical performance of Laser Scanning Unit dominantly. It is necessary to find out the relationship between the surface profile error of f-$\theta$lens and the beam profile focusing on the Organic Photo Conductive drum in order to analysis the beam profile problems such as appearance of side lobe and expansion of center lobe. In this research, a simulation process which relates the surface profile characteristics to the beam profile has been developed by CODE V. The simulated beam profile also have been compared with the measurement results.

  • PDF