• Title/Summary/Keyword: F-SCAN

Search Result 342, Processing Time 0.034 seconds

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF

The Characteristics of Residual Films on Silicon Surface $CHF_3/C_2F_6$ Reactive Ion Etching ($CHF_3/C_2F_6$ 플라즈마에 의한 실리콘 표면 잔류막의 특성)

  • 권광호;박형호;이수민;강성준;권오준;김보우;성영권
    • Journal of the Korean Vacuum Society
    • /
    • v.1 no.1
    • /
    • pp.145-152
    • /
    • 1992
  • Si surfaces exposed to CHF3/C2F6 gas plasmas ih reactive ion etching (RIE) have been characterized by X-ray photoelectron spectroscopy (XPS). CHF3/C2F6 gas plasma exposure of Si surface leads to the deposition of residual film containing carbon and fluorine. The narrow scan spectra of C 1s show various bonding states of carbon as C-Si, C-F/H, C-CFx(x $\leq$ 3), C-F, C-F2, and C-F3. The chemical bonding states of fluorine are described with F-Si, F-C and F-O. And the oxygen and silicon are also detected. The effects of parameters for reactive ion etching as CHF3/C2F6 gas ratio, RF power, and pressure are investigated.

  • PDF

A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

F-18 FDG Uptake in a Toxic Autonomous Thyroid Nodule

  • Lee, Myoung-Hoon;Park, Chan-H.;Kim, Hyun-Soo;Yoon, Seok-Nam;Hwang, Kyung-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.4
    • /
    • pp.286-287
    • /
    • 2001
  • A 44 year-old male patient was undergoing diagnosis and therapy for acute myelogenous leukemia (AML, M2). On physical examination a thyroid mass was palpated in the left lower lobe. He had palpitation and intolerance to heat. Thyroid function tests revealed hyperthyroidism; T3: 150ng/dl (N:60-90), fT4: 2.26 ng/dl (N:0.70-1.80), TSH: 0.01 ulU/ml (N:0.25-5.00). Ultrasonography demonstrated a hypoechoic mass with scattered calcifications measuring 2.55 2.03 3.64 cm in size. F-18 FDG camera-based PET scan performed as a follow-up study of AML revealed a focal increased uptake in the left neck, where an autonomous nodule was detected on Tc-99m thyroid scan. After the diagnosis of toxic autonomous nodule, Goetz disease, he underwent surgical nodulectomy. Microscopically, the nodule contained follicular proliferation with degenerative change but without evidence of thyroid carcinoma. Focal uptake in autonomous thyroid nodules is due to increased glycolysis within the nodules.

  • PDF

Comparative Evaluation of 18F-FDG Brain PET/CT AI Images Obtained Using Generative Adversarial Network (생성적 적대 신경망(Generative Adversarial Network)을 이용하여 획득한 18F-FDG Brain PET/CT 인공지능 영상의 비교평가)

  • Kim, Jong-Wan;Kim, Jung-Yul;Lim, Han-sang;Kim, Jae-sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.15-19
    • /
    • 2020
  • Purpose Generative Adversarial Network(GAN) is one of deep learning technologies. This is a way to create a real fake image after learning the real image. In this study, after acquiring artificial intelligence images through GAN, We were compared and evaluated with real scan time images. We want to see if these technologies are potentially useful. Materials and Methods 30 patients who underwent 18F-FDG Brain PET/CT scanning at Severance Hospital, were acquired in 15-minute List mode and reconstructed into 1,2,3,4,5 and 15minute images, respectively. 25 out of 30 patients were used as learning images for learning of GAN and 5 patients used as verification images for confirming the learning model. The program was implemented using the Python and Tensorflow frameworks. After learning using the Pix2Pix model of GAN technology, this learning model generated artificial intelligence images. The artificial intelligence image generated in this way were evaluated as Mean Square Error(MSE), Peak Signal to Noise Ratio(PSNR), and Structural Similarity Index(SSIM) with real scan time image. Results The trained model was evaluated with the verification image. As a result, The 15-minute image created by the 5-minute image rather than 1-minute after the start of the scan showed a smaller MSE, and the PSNR and SSIM increased. Conclusion Through this study, it was confirmed that AI imaging technology is applicable. In the future, if these artificial intelligence imaging technologies are applied to nuclear medicine imaging, it will be possible to acquire images even with a short scan time, which can be expected to reduce artifacts caused by patient movement and increase the efficiency of the scanning room.

Development of F-theta Lens for Laser Beam Printer (레이저 빔 프린터용 F-theta Lens 개발)

  • Kim, Sang-Suk;Kim, Hyun-Uk;Jeong, Sang-Hwa;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.386-390
    • /
    • 2006
  • Global consumption of aspheric lens will expand rapidly due to golbal transformation of the electronics based industry to optics based mechatronics. Especially, F-Theta lens is one of important parts in Laser Scanning Unit(LSU) because it affects the optical performance of LSU dominantly. Non axisymmetric machine based processing techologies are required to obtain high accuracy in utlra-precision aspheric core, the most important component in plastic injection molded F-Theta lens assembly. In this study, the core with non-axisymmetric aspheric shape which is used to emit the F-Theta lens was processed using the ultra precision processing technology and the shape accuracy of the core was measured. And the results there of were evaluated and compared with the emitted shape accuracy of F-Theta lens.

Case Report of Prostate Cancer Patient with Only Lymph Node Involvement on F-18 FDG PET/CT

  • Jung, Hyun Jin;Kang, Sungmin
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.391-395
    • /
    • 2018
  • We report a case of a patient with locally advanced prostate cancer who had only lymph node involvement without bone metastasis on F-18 FDG PET/CT. A 62-year-old Korean male was admitted to our hospital due to dysuria. His PSA level on admission was 79.35 ng/mL. A transrectal ultrasound-guided prostate biopsy confirmed prostate cancer and his Gleason score was 10 (5+5). F-18 FDG PET/CT demonstrated a hypermetabolic mass lesion with SUVmax 7.0 in the prostate and hypermetabolism with SUVmax 4.7 of the abdominal and pelvic lymph nodes. Tc-99m HDP bone scan showed no significant bone metastasis. The patient underwent hormonal therapy for 9 months. Follow-up F-18 FDG PET/CT showed significantly reduced size and FDG uptake in the prostate and abdominal and pelvic lymph nodes. In this case, treatment monitoring with F-18 FDG PET/CT showed decreased mass size and FDG uptake in the prostate and abdominal and pelvic lymph nodes.

Evaluation of 18F-FDG PET/CT Image Distortion by NEMA IEC Body Phantom (NEMA IEC Body Phantom을 이용한 18F-FDG PET/CT 영상의 왜곡 평가)

  • Park, jooncheol;Yang, hanjoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.427-433
    • /
    • 2013
  • Recently, 18F-FDG PET based CT scan was a critical examination that the after, before plan diagnosis and treatment of tumors. But, due to the distortion of SUV that should be proportional to the metabolic rate of glucose in the tumor, the other measurement methods are being on study. In this study, compared the degree of distortion of SUV that according to the volume of the tumor analysis ROI and VOI using the NEMA IEC Phantom. The results, the SUVmax, mean value are rapidly decreased with threshold value 500 mm2 interval of the ROI analysis, 1500 mm3 interval of the VOI analysis. When compared SUVmax value SUVmean, ROI and VOI analysis VOI measurements was 1.077 times higher SUVmax was 0.981 times highe compared to the value of the ROI measurement. Compare MTV, SUV 2.0 as measured by the volume of the VOI to Volume showed a slightly higher results(Volume / MTV = $93.4 %{\pm}14.8 %$). Considering the above results, Tumor evaluation by 18F-FDG PET / CT scan Consider each threshold value should be analyzed due to larger SUV's Distortion depending on the size of the tumor. VOI analysis is recommended. because it showed the VOI analysis is higher than the ROI analysis SUVmax and lower SUVmean due to VOI analysis than once as a measure of the wider area as measured ROI analysis. MTV (R2 = 0.999), a result close to the actual size of the tumor. but, more research is needed in this regard, because SUV according to the standards of value are affected.

Evaluation of convergence Elasticity of Liver Fibroscan used measurement with Ultrasonography (초음파를 이용한 간 섬유화 스캔 검사의 융합 탄성도 측정 평가)

  • Kim, Min-Jeong;Han, Man-Seok;Jang, Jae-Uk
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.79-85
    • /
    • 2017
  • The purpose of this research was to evaluate the clinical and the instrument of convergence utility of transient elastography (FibroScan(R):electromagnetic wave) in diagnosing and treating liver ailments through a comparison and an analysis between liver function blood test and transient elastography (FibroScan(R)) in patients with chronic hepatitis B virus infection. Of all the patients with chronic hepatitis B virus infection who visited clinic B in Daejeon City between July 1, 2015, and February 28, 2016, 75 who underwent a FibroScan(R) test were selected for this study. Their laboratory and liver function test results were compared for a correlation analysis before constructing an ROC (Receiver Operation Characteristic) curve. Aspartate aminotransferase (AST) and alanine aminotransferase (ALT) levels were 0.572 and 0.502, respectively, and showed highest correlation with fibrosis score, with statistical significance (p<0.000). Gamma glutamyltranspeptidase, total bilirubin, and alkaline phosphatase levels also showed relatively significant correlations in this order of sequence, while -fetoprotein and total protein levels did not show any statistically significant values. Albumin (-0.449) and platelet levels (-0.373) showed negative correlations with each other and no correlation with fibrosis score (p < 0.000). As liver fibrosis worsened, the accuracy of the ROC curve increased. At the F4 stage, which is the cirrhotic stage, the largest area under the curve was observed. FibroScan(R) showed significant correlation with the ALT (serum glutamic pyruvic transaminase) and AST (serum glutamic oxaloacetic transaminase) levels in the liver function test, which is a routine test for patients with chronic liver ailments. This implies that fibrosis correlates with liver inflammation severity.