• Title/Summary/Keyword: F-18 FDG

Search Result 540, Processing Time 0.03 seconds

The Role of $^{18}F-fluorodeoxyglucose$ Positron Emission Tomography in Gastrointestinal Stromal Tumors (위장관 간질 종양(Gastrointestinal stromal tumor)에서 $^{18}F-fluorodeoxyglucose$ positron emission tomography의 역할)

  • Yoo, Ie-Ryung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.46-51
    • /
    • 2008
  • Gastrointestinal stromal tumors (GIST) are the most common mesenchymal neoplasm of the gastrointestinal tract, and can be distinguished from the smooth muscle or neural tumors in approximately 95% of patients by expression of the KIT receptor tyrosine kinase (CD117). GISTs are known to have high malignant potential and none can be labeled definitely as benign. However, GISTs are unresponsive to standard sarcoma chemotherapy, and only complete surgical resection provides chance for cure. Although the imaging modality of choice is enhanced CT scan in patients with GIST, FDG PET can reflect the malignant potential of GIST. Clinical management of patients with GISTs has dramatically changed with the introduction of novel therapeutics, such as imatinib mesylate (Glivec). This has created a need to re-evaluate the existing criteria used to assess treatment response. FDG PET as functional imaging modality proved to be significantly more accurate than CT alone when assessing GIST response to imatinib. And, FDG PET and PET ICT have been found to be highly sensitive in detecting early response, and to be useful in predicting long-term response to imatinib in patients with recurrent or metastatic GISTs.

Significantly Low Effective Dose from 18FDG PET/CT Scans Using Dose Reducing Strategies: "Lesser is Better"

  • uz Zaman, Maseeh;Fatima, Nosheen;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3465-3468
    • /
    • 2016
  • Background: Fluorodeoxyglucose ($^{18}FDG$) PET/CT imaging has become an important component of the management paradigm in oncology. However, the significant imparted radiation exposure is a matter of growing concern especially in younger populations who have better odds of survival. The aim of this study was to estimate the effective dose received by patients having whole body $^{18}F$-FDG PET/CT scanning as per recent dose reducing guidelines at a tertiary care hospital. Materials and Methods: This prospective study covered 63 patients with different cancers who were referred for PET/CT study for various indications. Patients were prepared as per departmental protocol and 18FDG was injected at 3 MBq/Kg and a low dose, non-enhanced CT protocol (LD-NECT) was used. Diagnostic CT studies of specific regions were subsequently performed if required. Effective dose imparted by 18FDG (internal exposure) was calculated by using multiplying injected dose in MBq with coefficient $1.9{\times}10^{-2}mSv/MBq$ according to ICRP publication 106. Effective dose imparted by CT was calculated by multiplying DLP (mGy.cm) with ICRP conversion coefficient "k" 0.015 [mSv / (mG. cm)]. Results: Mean age of patients was $49{\pm}18$ years with a male to female ratio of 35:28 (56%:44%). Median dose of 18FDG given was 194 MBq (range: 139-293). Median CTDIvol was 3.25 (2.4-6.2) and median DLP was 334.95 (246.70 - 576.70). Estimated median effective dose imparted by $^{18}FDG$ was 3.69 mSv (range: 2.85-5.57). Similarly the estimated median effective dose by low dose (non-diagnostic) CT examination was 4.93 mSv (range: 2.14 -10.49). Median total effective dose by whole body 18FDG PET plus low dose non-diagnostic CT study was 8.85 mSv (range: 5.56-13.00). Conclusions: We conclude that the median effective dose from a whole body 18FDG PET/CT in our patients was significantly low. We suggest adhering to recently published dose reducing strategies, use of ToF scanner with CT dose reducing option to achieve the lower if not the lowest effective dose. This would certainly reduce the risk of second primary malignancy in younger patients with higher odds of cure from first primary cancer.

Incidental detection of myocardial ischemia during F-18 FDG CoDe PET for the evaluation of a solitary pulmonary nodule

  • Park, Chan-H.;Park, Kwang-J.;Lee, Myoung-Hoon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.398-400
    • /
    • 2001
  • The authors report a case of unsuspected myocardial ischemia detected during CoDe FDG PET (coincidence detection fluorodeoxyglucose positron emission tomogram) which was performed for the evaluation of a solitary pulmonary nodule. Camera-based FDG PET without attenuation correction often reveals false defect in the inferior wall of the left ventricle in normals due to excessive attenuation. However, this asymptomatic patient had increased uptake in the inferior wall suggesting ischemic myocardium. The scan finding was confirmed by Tl-201 myocardial SPECT and coronary angiogram. The patient then underwent successful PTCA of mild RCA and right ventricular branch followed by right upper lobectomy for small cell lung cancer.

  • PDF

Consideration on the Satisfaction of Patients and SUV Variation According to Whether or not to Listen to Music after 18F-FDG Injection (PET/CT 검사에서 18F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰)

  • Park, Suyoung;Yun, Sunhee;Kim, Hwasan;Kim, Hyunki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.37-43
    • /
    • 2013
  • Purpose: PET/CT scan using the SUV (Standardized Uptake Value) of radiopharmaceutical uptake in organs and tissues as an objective indicator makes it possible to analyze physiological and chemical reactions of human organs. This study analyzes the change of the SUV uptake in accordance with the way how PET/CT patients take a rest after the injection of $^{18}F-FDG$ (Fluororo-deoxyglucose). And also subjective satisfaction is assessed listening to music while taking a rest. Materials and Methods: From April 2011 until February 2013, Among the Primary cancer patients who admitted to the Catholic Medical Center (Seoul & Bucheon St. Mary's Hospital) and scanned $^{18}F-FDG$ PET/CT and also received care through the tracking test (mean age $55.61{\pm}12.41$ years, 108 people, 48 men and 60 women) were selected. The patients were divided into two groups. The first group (A: basal study) is requested to take a rest in bed quietly after the injection. However the second one (B: follow up study) is requested to listen to the music while taking a rest. And then SUV analysis was performed respectively. At the end of the scan, ROI (Region Of Interest) were set from the center of the liver (right lobe) and 3 spots of the brain (frontal, temporal, and occipital lobes). And the SUV was calculated. To identify the correlation among those ROIs, paired t-test was performed using SPSS software (Version 12.0K for windows, P>0.05). Also, after the PET/CT scan the satisfaction study was conducted of all the patients. 1:1 questionnaire survey was performed, and that questionnaire was made using the Likert 5-point scale. By utilizing those questionnaires, the analysis about simple frequency, percentage, average, and standard deviation was performed. Results: The SUV change of the 4 designated ROIs in accordance with listening to music was not statistically significant. (Frontal lobe P-value=0.611, Occipital lobe P-value=0.499, Temporal lobe P-value=0.717, Liver P-value=0.334: P-value>0.05) And the satisfaction study indicated that group B was appear to be 0.42 points (5 basis points) higher than group A. It showed that patients are more satisfied in group B than group A. Conclusion: when performing PET/CT scan using $^{18}F-FDG$, listening to music after the injection of the radiopharmaceuticals does not affect the SUV but given the state of the psychological comfort that may increase the patient's satisfaction.

  • PDF

Performance of pre-treatment 18F-fluorodeoxyglucose positron emission tomography/computed tomography for detecting metastasis in ovarian cancer: a systematic review and meta-analysis

  • Han, Sangwon;Woo, Sungmin;Suh, Chong Hyun;Lee, Jong Jin
    • Journal of Gynecologic Oncology
    • /
    • v.29 no.6
    • /
    • pp.98.1-98.13
    • /
    • 2018
  • Objective: We describe a systematic review and meta-analysis of the performance of ${18}F$-fluorodeoxyglucose ($^{18}F-FDG$) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. Methods: MEDLINE and Embase were searched for diagnostic accuracy studies that used $^{18}F-FDG$ PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. Results: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61-0.81) and 0.93 (95% CI=0.85-0.97), respectively. There was considerable heterogeneity in sensitivity ($I^2=97.57%$) and specificity ($I^2=96.74%$). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67-0.87 and 0.96; 95% CI=0.92-0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46-0.77 and 0.84; 95% CI=0.69-0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90-0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24-1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94-1.00) than those with a greater prevalence (0.89; 95% CI=0.80-0.97). Conclusion: Pre-treatment $^{18}F-FDG$ PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.

A correlation between comprehensive neck dissection and increased uptake around the sternoclavicular joint on post-operative 18F-FDG PET/CT (경부절제술과 술후 시행된 PET/CT상의 흉쇄관절 섭취 증가의 상관관계 분석)

  • Oh, So Won;Lee, Doh Young;Kim, Bo Hae;Kim, Kwang Hyun;Kim, Yu Kyeong;Jung, Young Ho
    • Korean Journal of Head & Neck Oncology
    • /
    • v.34 no.1
    • /
    • pp.21-27
    • /
    • 2018
  • Background/Objectives: This study aimed to evaluate the changes of uptake around the sternoclavicular joint (SCJ) according to 18F-FDG PET images in patients with head and neck cancer who underwent neck dissection. Materials & Methods: Retrospectively, the medical records of patients who received selective or comprehensive neck dissection were reviewed. Preoperative and 1-year postoperative 18F-FDG PET images, if available, were analyzed by nuclear medicine physicians in both qualitative and quantitative manners. Correlation between the changes of uptake around SCJ and perioperative data were statistically analyzed. Results: Thirty-seven patients satisfying the inclusion criteria were enrolled. Seven patients with increased uptake around SCJ on 1-year postoperative 18F-FDG PET showed a correlation with radical or comprehensive neck dissection, accessory nerve sacrifice, and high postoperative SUVmax. When 20 patients with increased uptake around SCJ according to quantitative measurement were compared with other patients without increased uptake, no parameter was significantly different, except postoperative SUVmax. Bivariate logistic regression analysis revealed that the clinical symptom (shoulder or sternal pain) was significantly correlated with the extent of neck dissection (OR 0.227, CI 0.053-0.966, p=0.045) and spinal accessory nerve sacrifice (OR 13.500, CI 1.189-153.331, p=0.036). Conclusions: Increased uptake around SCJ on 1-year postoperative 18 F-FDG PET was correlated with either the radical or comprehensive procedure, as well as with accessory nerve sacrifice. This suggests that subjective analysis of 18F-FDG PET can be used to detect subclinical shoulder instability.

Optimization of Flushing through Correlation Analysis between the Number of Flushing and Residual Activity in PET/CT (PET/CT에서 최적의 플러싱횟수를 위한 잔류방사능과의 상관분석)

  • Woo-Yeong Choi;Yeong-Sik Jee;Chang-Yong Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.701-707
    • /
    • 2023
  • In PET/CT, the injection volume of 18F-FDG directly affects the SUV(standard uptake value), which can affect the reading results. Therefore, it is important to inject the correct dose value of 18F-FDG. In this study, we performed the correlation between the residual radioactivity remaining in the syringe and catheter insertion device according to the number of flushing during 18F-FDG injection. CRC-25R dose calibrator, catheter insertion devices, 3 cc syringes and 50 cc physiological saline were used in this study, and the results were statistically analyzed. As a result, the total residual radioactivity of the syringe and catheter insertion device remained the highest at 5.84% after two flushing, and the least remained at 1.49% after five flushing. The correlation analysis results showed that the number of flushing had a negative correlation with the residual radioactivity of the syringe at -0.436 and the catheter insertion device at -0.300. As a result of one-way distributed analysis of the average according to the number of flushing, the syringe showed a significant decrease at 4 times, and the catheter insertion device showed a significant decrease at 5 times. However, considering that an average of 0.8% remains in the case of catheter insertion devices, four time flushing seems to be the most appropriate.

Comparison with $^{99m}Tc$ MDP Bone Scintigraphy and Whole body $^{18}FDG$ PET for the Evaluation of Bone metastases in Patients with Lung Cancer (폐암의 골전이에서 $^{99m}Tc$ MDP 골주사와 전신 $^{18}FDG$ PET의 비교)

  • Chung, Jae Ho;Park, Moo Suk;Hahn, Chang Hoon;Moon, Jin Wook;Kim, Young Sam;Kim, Se Kyu;Chang, Joon;Lee, Jong Doo;Kim, Sung Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.280-286
    • /
    • 2003
  • Background : $^{99m}Technetium$ methylene diphosphonates($^{99m}Tc$ MDP) bone scintigraphy is current method of choice for the detection of bone metastases, but whole body $^{18}F$-fluoro-deoxy-D-glucose positron emission tomography($^{18}FDG$ PET) offers superior spatial resolution and improved sensitivity. So we compared whole body $^{18}FDG$ PET with $^{99m}Tc$ MDP bone scintigraphy in patients with skeletal metastases from lung cancer. Patients and Methods : Ninety-two patients with lung cancer taken $^{18}FDG$ PET together with a $^{99m}Tc$ MDP bone scintigraphy within 1 month between March 2000 and March 2003 were investigated retrospectively. Results : The sensitivity, specificity and accuracy of the $^{99m}Tc$ MDP bone scintigraphy versus $^{18}FDG$ PET for the detection of bone metastases in lung cancers were 59% vs 82%, 71% vs 94%, and 68% vs 91%, respectively. In the diagnosis of bone metastases from lung cancer, $^{18}FDG$ PET was statistically superior to $^{99m}Tc$ MDP bone scintigraphy in its specificity and accuracy(p<0.0001). Conclusions : Whole body $^{18}FDG$ PET may be useful in detecting bone metastases among patients with lung cancer.

Evaluation of metabolic tumor volume using different image reconstruction on 18F-FDG PET/CT fusion image (18F-FDG PET/CT 융합영상에서 영상 재구성 차이에 의한 MTV (Metabolic tumor volume) 평가)

  • Yoon, Seok Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.1
    • /
    • pp.433-440
    • /
    • 2018
  • Recently, MTV(metabolic tumor volume) has been used as indices of the whole tumor FDG uptake on FDG PET image but it is influenced by image reconstruction. The purpose of this study was to evaluate the correlation between actual volume and metabolic tumor volume applying different SUVmax threshold for different reconstruction algorithm on phantom study. Measurement were performed on a Siemens Biograph mCT40 using a NEMA IEC body phantom containing different size six spheres filled with F18-FDG applying four SBRs (4:1, 8:1, 10:1, 20:1). Images reconstructed four algorithms (OSEM3D, OSEM3D+PSF, OSEM3D +TOF, OSEM3D+TOF+PSF) and MTV were measured with different SUVmax threshold. Overall, the use of increasing thresholds result in decreasing MTV. and increasing the signal to background ratio decreased MTV by applying same SUVmax threshold. The 40% SUVmax threshold gave the best concordance between measured and actual volume in PSF and PSF+TOF reconstruction image. and the 45% threshold had the best correlation between the volume measured and actual volume in OSEM3D and TOF reconstruction image. we believe that this study will be used when the measurement of MTV applying various reconstruction image.

Imaging of Gastric Cancer Metabolism Using 18 F-FDG PET/CT

  • Yun, Mijin
    • Journal of Gastric Cancer
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Aerobic glycolysis has been the most important hypothesis in cancer metabolism. It seems to be related to increased bioenergetic and biosynthetic needs in rapidly proliferating cancer cells. To this end, F-18 fluorodeoxyglucose (FDG), a glucose analog, became widely popular for the detection of malignancies combined with positron emission tomography/computed tomography (PET/CT). Although the potential roles of FDG PET/CT in primary tumor detection are not fully established, it seems to have a limited sensitivity in detecting early gastric cancer and mainly signet ring or non-solid types of advanced gastric cancer. In evaluating lymph node metastases, the location of lymph nodes and the degree of FDG uptake in primary tumors appear to be important factors affecting the diagnostic accuracy of PET/CT. In spite of the limited sensitivity, the high specificity of PET/CT for lymph node metastases may play an important role in changing the extent of lymphadenectomy or reducing futile laparotomies. For peritoneal metastases, PET/CT seems to have a poorer sensitivity but a better specificity than CT. The roles of PET/CT in the evaluation of other distant metastases are yet to be known. Studies including primary tumors with low FDG uptake or peritoneal recurrence seem suffer from poorer diagnostic performance for the detection of recurrent gastric cancer. There are only a few reports using FDG PET/CT to predict response to neoadjuvant or adjuvant chemotherapy. A complete metabolic response seems to be predictive of more favorable prognosis.