• Title/Summary/Keyword: Eyes

Search Result 2,540, Processing Time 0.033 seconds

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

Effect of substrate bias voltage on a-C:H film (기판 bias 전압이 a-C:H 박막의 특성에 미치는 영향)

  • 유영조;김효근;장홍규;오재석;김근식
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.4
    • /
    • pp.348-353
    • /
    • 1997
  • Hydrogenated amorphous carbon(a-C:H) films were deposited on p-type Si(100) by DC saddle-field plasma enhanced CVD to investigate the effect of substrate bias on optical properties and structural changes. They were deposited using pure methane gas at a wide range of substrate bias at room temperature and 90 mtorr. The substrate bias voltage ($V_s$) was employed from $V_s=0 V$ to $V_s=400 V$. The information of optical properties was investigated by photoluminescence and transmitance. Chemical bondings of a-C:H have been explored from FT-IR and Raman spectroscopy. The thickness and relative hydrogen content of the films were measured by Rutherford backscattering spectroscopy (RBS) and elastic recoil detection (ERD) technigue. The growth rate of a-C:H film was decreased with the increase of $V_s$, but the hydrogen content of the film was increased with the increase of $V_s$. The a-C:H films deposited at the lowest $V_s$ contain the smallest amount of hydrogen with most of C-H bonds in the of $CH_2$ configuration, whereas the films produced at higher $V_s$ reveal dominant the $CH_3$ bonding structure. The emission of white photoluminescence from the films were observed even with naked eyes at room temperature and the PL intensity of the film has the maximum value at $V_s$=200 V. With $V_s$ lower than 200 V, the PL intensity of the film increased with V, but for V, higher than 200 V, the PL intensity decreased with the increase of $V_s$. The peak energy of the PL spectra slightly shifted to the higher energy with the increase of $V_s$. The optical bandgap of the film, determined by optical transmittance, was increased from 1.5 eV at $V_s$=0V to 2.3 eV at $V_s$=400 V. But there were no obvious relations between the PL peak and the optical gap which were measured by Tauc process.

  • PDF

A Study on the Effect of Spirulina-containing Cosmetics Using Micro-Needle (미세다륜침을 이용한 스피루리나 함유 화장품의 효과 연구)

  • Jung, SuJin;Lee, Hyunjin;Li, ShunHua
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.269-276
    • /
    • 2017
  • In this study, a test was conducted to examine the effects of micro-needle therapy (MTS) and cosmetics containing spirulina on improving the skin tone, skin hydration, hyper-pigmentation, and fine lines of middle-aged women in their 40s and 50s and to propose an effective skin care method. The subjects were divided into a control group of eight people who used serum and cream mask that does not contain MTS and spirulina, and an experimental group who used serum and cream containing MTS and spirulina. The test was conducted with six 30-minute sessions for one week. The change in skin was measured over three times in the week of the test, after six weeks of the test, and two weeks after the test had finished. The result showed that after six weeks of the test, in the experimental group, the skin tone (color brightness, saturation brightness, skin brightness) and moisture showed a significant increase (p<0.05), while the number of small hyper-pigmentation and large hyper-pigmentation, as well as the length of crow's feet, melanin, erythema showed a significant reduction (p<0.05). No significant differences in fine lines under the eyes and length of crow's feet were observed. Two weeks after the test was finished, the experimental group showed a significant decrease in the length of crow's feet and melanin (p<0.05), and a significant increase in skin brightness and moisture (p<0.05). Even after the test was completed, the skin brightness, fine lines, melanin, and moisture improved continuously. In conclusion, skin care using MTS and cosmetics containing spirulina was more effective on improving the skin tone, hydration, hyper-pigmentation, and fine lines, than skin care without using them.

Blue-light Induces the Selective Cell Death of Photoreceptors in Mouse Retina (청색광에 의한 마우스 망막손상에서 선택적 광수용세포의 사멸)

  • Kang, Seo-young;Hong, Ji Eun;Choi, Eun jung;Lyu, Jungmook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.69-76
    • /
    • 2016
  • Purpose: The study was conducted to determine that photoreceptors of mouse having pigment in RPE(retinal pigment epithelium) can be damaged by blue-light and apoptosis of specific cells among photoreceptors are induced by blue-light, and to assist the investigation of AMD(Age-related macular degeneration) mechanisms and development of AMD drugs. Methods: C57Black mice were injured by irradiating $2800{\pm}10lux$ of 463 nm LED for 6 hours after 24 hours dark adaptation and eyes were enucleated 1, 3, 7 days. Damage of retina induced by blue-light was determined by western blotting GFAP(Glial fibrillary acidic protein) expression. In the light-injured retina, cell death of photoreceptors was determined by TUNEL(Terminal deoxynucleotidyl transferase dUTP nick end labeling) assay. ERK(Extracellular signal-regulated kinases), JNK, and SRC(sarcoma) expression were assessed by western blotting to determine regulated pathway. Blue light-injured retina were immunostained with antibodies against Opsin and Rhodopsin as markers of photoreceptors to compared the damage cone cells with rod cells. Results: After 1, 3 and 7 days from exposure to blue-light, thickness of retina was more decreased than control, and more decreased at nuclear layer than at outer plexiform layer and GFAP expression was increased day 1 after blue-light injured. While phosphorylated ERK and SRC protein expressions at day 1 were increased after blue-light injured, phosphorylated c-JUN was decreased. Fluorescence intensity analysis showed that markers of cone and rod cells were decreased after blue-light injured and Opsin was more decreased than Rhodopsin. Conclusions: The study suggests possibilities that the blue-light promotes retinal damage and causes apoptotic cell death via ERK and SRC pathway in mouse retina, and blue-light retinal damage is more induced cone cells apoptosis than rod cells directly.

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.

A Comparison of Lens Centrations on Cornea with RGP Lens Fitting by the Measured Values using Keratometer and Corneal Topography (각막곡률계와 각막 지형도 검사에서의 측정값을 이용한 RGP 렌즈 피팅시 각막에서의 중심안정위치 비교)

  • Kim, So Ra;Park, Sang-Il;Lee, Se Eun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2011
  • Purpose: The present study was conducted to compare the centration of RGP lens on cornea when lens was fitted based on keratometric astigmatisms measured by keratometer and the lens centration when fitted by corneal topography. Methods: Thirty eight eyes of 19 male and female in their twenties were applied RGP lens with 9.9 mm of diameter by the keratometric astigmatisms classified by the measurement with a keratometer. Then, lens centrations were estimated using high speed camera and compared with the lens centration when fitted by total keratometric astigmatism using corneal topography. The relationship of the steepest location of cornea and lens centration was further compared. Results: With the rule astigmatism, lens centration was not changed even with the difference in central and total keratometric astigmatisms. When the relationship of the steepest part of cornea measured by corneal topography and lens centration was analyzed, the lens centration in vertical direction was exactly correlated with the steepest part of cornea in 52.3% of subjects. In the case of non-correlation, the steepest part of cornea was mostly upper part of cornea, however, lens centration was located on lower part of cornea. The lens centration in horizontal direction was exactly correlated with the steepest region of cornea in 65.6% of subjects. In non-correlated case, the difference in cornea curvatures between the steepest and the flattest parts was smaller than 0.05 mm in 76.9% of subjects. Conclusions: From these results, we conclude that corneal topographic patterns may more contribute the centration of RGP lens on cornea than the difference in central and total keratometric astigmatisms.

Predicting Powers of Spherical Rigid Gas-permeable Lenses Prescription (구면 RGP 렌즈의 처방 굴절력 예측)

  • Yu, Dong-Sik;Yoo, Jong-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.219-225
    • /
    • 2010
  • Purpose: Usefulness in predicting the power of spherical rigid gas-pearmeable (RGP) lenses prescription using dioptric power matrices and arithmetic calculations was evaluated in this study. Noncycloplegic refractive errors and over-refractions were performed on 110 eyes of 55 subjects (36 males and 19 females, aged $24.60{\pm}1.55$years) in twenties objectively with an auto-refractometer (with keratometer) and subjectively. Tear lenses were calculated from keratometric readings and base curves of RGP lenses, and the power of RGP lenses were computed by a dioptric power matrix and an arithmetic calculation from the manifest refraction and the tear lens, and were compared with those by over-refractions in terms of spherical (Sph), spherical quivalent (SE) and astigmatic power. Results: The mean difference (MD) and 95% limits of agreement (LOA=$MD{\pm}1.96SD$) were better for SE (0.26D, $0.26{\pm}0.70D$) than for Sph (0.61D, $0.61{\pm}0.86D$). The mean difference and agreement of the cylindrical power between matrix and arithmetic calculation (-0.13D, $-0.13{\pm}0.53D$) were better than between the others (-0.24D, $0.24{\pm}0.84D$ between matrix and over-refraction; -0.12D, $0.12{\pm}1.00D$ between arithmetic calculation and over-refraction). The fitness of spherical RGP lenses were 54.5% for matrix, 66.4% for arithmetic calculation and 91.8% for over-refraction. Arithmetic calculation was close to the over-refraction. Conclusions: In predicting indications and powers of spherical RGP lens fitting, although there are the differences of axis between total (spectacle) astigmatism and corneal astigmatism, Spherical equivalent using an arithmetic calculation provides a more useful application than using a dioptric power matrix.

Changes in KVA Resulting from Correction Condition of Refractive Error (굴절이상 교정상태에 따른 동적시력 변화)

  • Shim, Hyun-Suk;Kim, Sang-Hyun;Kang, Hye-Sook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • Purpose: This study are to analyze and to compare between pupillary size, reaction time, refractive error, corrected vision, dominant eye, static visual angle (SVA) and kinetic visual acuity (KVA) of male and female college students, to measure KVA of them in full correction and to identify changes of KVA by +0.50 D and -0.50 D spherical power addition respectively in full correction condition. Methods: KVA, SVA, pupillary size, reaction time, refractive error, corrected vision and dominant eye of 40 male and 40 female optical science students were measured by utilizing KOWA AS-4A, reaction time measurement program, subjective refractometer, and objective refractometer, and KVAs were measured when +0.50 D/-0.50 D were added in both eyes respectively. Results: Binocular KVA of whole subjects was $0.45{\pm}0.22$, and in monocular KVAs were $0.36{\pm}0.19$ for right eye and $0.34{\pm}0.19$ for left eye, and binocular KVA was significantly higher than monocular KVA. It appeared that the better SVA was, the better KVA was in significant way, and in terms of refractive error the less myopia amount was, the better KVA was, but it was not significant statistically. The lower astigmatism was, the slightly and significantly higher KVA was when dividing between equal or less than -1.00 D astigmatism group and over -1.00 D astigmatism group. In resulting from correction condition of refractive error KVAs were $0.45{\pm}0.22$ for full correction, $0.26{\pm}0.15$ for +0.50 D addition, $0.48{\pm}0.22$ for -0.50 D addition which indicates that KVA in over myopia correction was significantly the highest and followed by full correction and under correction. Similar findings were revealed in both male and female, and KVA of male was better than female in comparing between male and female. There was no significantly different KVA between dominant eye and non-dominant eye. Conclusions: Accordingly, it is concluded that KVA is related with far distance SVA, astigmatism amount, and refractive error amount except a dominant eye. Through this research, it was found that prescription for enhancing KVA is to make full correction or to overcorrect slightly myopia.

A Study on the Preference Factors of KakaoTalk Emoticon (카카오톡 이모티콘 선호도에 미치는 영향 요인에 관한 연구)

  • Lee, Jong-Yoon;Eune, Juhyun
    • Cartoon and Animation Studies
    • /
    • s.51
    • /
    • pp.361-390
    • /
    • 2018
  • Users of KakaoTalk emoticons use Kakao Talk emoticons as means of communicating their emotions in virtual space. Emotional state is represented by design element (auxiliary, color, form, motion) and storytelling element contained in emoticons. The purpose of this study is to investigate the factors of the storytelling and design elements of kakaoTalk emoticons and how they prefer the kakaoTalk emoticons as emotional expression means. In terms of storytelling, crocodiles, peaches, dogs, ducks, lions, moles, and rabbits were made up of ordinary fruits and animals. Most of the emoticons are composed of stories with unique personality, and each story has a complex one by one, which makes it easy for users to approach and use them. In terms of design, I used various auxiliary elements (flame, sweat, tears, runny nose, angry eyes, etc.) to express angry, sincere, nervous, begging, joy, and sadness. The color elements consisted of most of the warm color series with the unique colors (green, red, yellow, pink, white, black, brown, etc.) of emoticon characters regardless of feelings of joy, anger, sadness, pleasure. The form factor is composed of a round shape when expressing factors such as joy and sadness. On the other hand, when FRODO and NEO express sadness and anger, they represent the shape of a rectangle. The motion elements are horizontal, vertical, and oblique expressions of APPEACH, NEO, TUBE, and JAY-G, expressing emotional expressions of sadness, anger, and pleasure. APEACH, TUBE, MUZI & / Shows the dynamic impression of the oblique and the radiation / back / forward / rotation. The anger of TUBE and FRODO shows horizontal / vertical / diagonal and radial motion. As a result of this study, storytelling is structured in accordance with each emoticon character. In terms of design, auxiliary elements such as flame, sweat, and tears are represented by images. The color elements used the unique colors of the character series regardless of the difference of emotion. The form factor represented various movements for each emotion expression. These findings will contribute to the development of communication, emotional design and industrial aspects. Despite the significance of the above paper, I would like to point out that the analysis framework of the storytelling and the semiotic analysis of the supplementary elements are not considered as limitations of the study.

Studies on the Fracture Healing in the Alloxan treated Rabbits (Alloxan 투여 가토(家兎)에 대한 골절치유 실험)

  • Kim, Sung-Joon
    • The Korean Journal of Pharmacology
    • /
    • v.7 no.1
    • /
    • pp.53-65
    • /
    • 1971
  • It is well known that diabetes mellitus is associated with metabolic derangements, such as hyper-glycemia, ketosis, glycosuria, and also widespread alterations in the blood vessels, kidneys, eyes, peripheral nerves and heart. It is also recognized that healing of skin wound is delayed in diabetics. In bone, according to Aegerter, osteopenia develops in diabetes mellitus and it is chiefly ascribed to overutilization of protein. Shim claims that total blood flow to the entire skeletal system is approximately 4 to 8 percent of resting cardiac output and blood supply to the skeletal system would be decreased on account of secondary arteriosclerotic changes in the diabetics. An adequate blood supply is an essential factor in the healing process of fracture, and disturbed blood flow, either local or systemic, will invariably delay union of the fragments or the fragments from being fused. As the author has encountered several cases of diabetics in whom healing of fracture was delayed or incomplete, this experimental study was undertaken to elucidate the effects of hyperglycemia and diabetes mellitus on the healing process of fracture. In this experiment adult albino rabbits, weighing about 2 kg. were used and divided into 6 groups. The femur of each animal was fractured surgically, and then the healing process of fracture was periodically checked by radiography at an interval of one week for a period of 6 weeks. Thereafter, all the rabbits were killed to obtain tissue preparation of the femur. The experimental groups were as follows; 1) Control group: Six rabbits sustained a surgical fracture to the femur, without being given any other treatment or drug. 2) Alloxan-treated group: For inducing diabetes, alloxan was given intravenously to 17 rabbits in various dose as follows; to 7 of them 40 mg/kg, to 6 rabbits 80 mg/kg and to 4 rabbits 120 mg/kg of body weight, respectively. 3) Insulin-treated group: Protamine-zinc insulin was injected subcutaneously to each of 6 rabbits in a daily dose of 1 unit per kilogram of body weight. 4) Group treated with insulin after alloxan: Four rabbits were given 80 mg of alloxan once and than 1 unit of insulin per kilogram of body weight daily. Another 5 rabbits were injected 1 unit of insulin per kg of body weight daily following administration of alloxan in a dose of 120 mg/kg. 5) Homotransplantation group: Following intravenous injection of alloxan in a dose of 120 mg/kg, 10 rabbits underwent homotransplantation of a short bone segment to the femur. Five of them were subsequently given 1 unit/kg of insulin daily. 6) Sugar-treated group: six rabbits were fed $15{\sim}20$ gm of sugar daily throughout the period of experiment. The results obtained are summarized as follows; 1. Blood sugar level and damage to the pancreatic islet increased proportionately when alloxan was given to the rabbits in various doses. No appreciable change could be observed in the islets when the blood sugar level was altered by either oral administration of sugar or subcutaneous injection of insulin. 2. Comparing with the control group, healing of fracture was delayed in the alloxan-treated group, while callus formation and periosteal reaction were shown to be more prominent in this group and subsequently, the ultimate osseous tissue formed at the fracture site was significantly smaller in amount and less compact. These findings were more marked as the amount of alloxan increased. 3. Administration of insulin prevented the delay in healing process of fracture in the rabbits with alloxan-induced hyperglycemia. In this case, the course and progression of fracture healing were almost similar to those of control group. 4. Union between the host bone and the fragment transplanted from other rabbit of the same species was more delayed in the group treated with alloxan alone than in the group to which insulin was administered after development of alloxan-induced diabetes. In both groups periosteal new bone developed from the ends of the host bone, above and below the transplanted fragment, and directly fused with failure of periosteal callus to bridge the adjacent ends of the host bone and the transplanted fragment. 5. The healing process of fracture was not inhibited by alteration in blood sugar level when the blood sugar was abnormally increased by excessive sugar intake or lowered by administration of insulin alone. The healing of fracture in these groups progressed similarly as in the control group. In brief summary, it appears that the healing process of fracture would be definitely disturbed in diabetic state brought about by damage to the pancreatic islet. As such an inhibition could be overcome with insulin, it seems that insulin plays an important role in healing of fracture, but alteration in blood sugar level alone does not modify healing process of fracture to significant degree.

  • PDF