• Title/Summary/Keyword: Eye contact

Search Result 211, Processing Time 0.031 seconds

Frank Lloyd Wright's Houses in relation to the Earth and the Sky (라이트의 주택에 나타난 대지와 하늘의 인식에 관한 연구)

  • Kim, Tai Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.18 no.3
    • /
    • pp.1-8
    • /
    • 2016
  • Frank Lloyd Wright(1867-1959) had the confident concept that architecture should be at home in nature. His architecture was meant to bear an intimate relation to the earth and the sky, and should look as though it began there at the ground and contrasted with the sky. In handling all the details of house design elements, his efforts for being married to the ground was to conceive the void of the sky. This study is to research his thinking process and its development to the earth and the sky, and to analyze how such thought could reflect his houses. The mass of house are divided into three parts such as the foundation or base, body, and roof. These parts are respectively related to the earth and the sky. This study goes on regarding them as an analytical framework. The subjects of study are the Prairie houses in the early 20th century and the Usonian houses after 1930's. As results of this study, the earlier foundation as a platform appeared as a base and water table, and a strong baseline pressed the structures into the soil in the Prairie houses. The direct contact of wood and brick to ground were dominant details after Wiley house(1934). The base was almost invisible to the eye in the Usonian houses. Secondly, the pierlike shapes and delicate friezes of walls were anchored to the ground, and horizontal bands as trims or copings also got close to the earth. These characters had disappeared after the Allen house(1917), all components including exterior walls had been unified with the grid patterns in the Usonian houses. Thirdly, the overhanging cantilever roof had got to the earthbound by the reflection of shadow as well as their evident horizontal. He lowered the roof, lengthened and brought it closer to the ground. In this way, Frank Lloyd Wright intended his houses to be at home in nature. And also he tried to bind the houses to the earth and contrasted them with the sky. The houses would perform their highest function in relation to the earth and sky.

Surface Modification and Fibrovascular Ingrowth of Porous Polyethylene Anophthalmic Implants

  • Yang, Hee-Seok;Park, Kwi-Deok;Son, Jun-Sik;Kim, Jae-Jin;Han, Dong-Keun;Park, Byung-Woo;Baek, Se-Hyun
    • Macromolecular Research
    • /
    • v.15 no.3
    • /
    • pp.256-262
    • /
    • 2007
  • The purpose of this study was to determine the effect of surface modification on the fibrovascular ingrowth into porous polyethylene (PE) spheres ($Medpor^{(R)}$), which are used as an anophthalmic socket implant material. To make the inert, hydrophobic PE surface hydrophilic, nonporous PE film and porous PE spheres were subjected to plasma treatment and in situ acrylic acid (AA) grafting followed by the immobilization of arginine-glycine-aspartic acid (RGD) peptide. The surface-modified PE was evaluated by performing surface analyses and tested for fibroblast adhesion and proliferation in vitro. In addition, the porous PE implants were inserted for up to 3 weeks in the abdominal area of rabbits and, after their retrieval, the level of fibrovascular ingrowth within the implants was assessed in vivo. As compared to the unmodified PE control, a significant increase in the hydrophilicity of both the AA-grafted (PE-g-PAA) and RGD-immobilized PE (PE-g-RGD) was observed by the measurement of the water contact angle. The cell adhesion at 72 h was most notable in the PE-g-RGD, followed by the PE-g-PAA and PE control. There was no significant difference between the two modified surfaces. When the cross-sectional area of tissue ingrowth in vivo was evaluated, the area of fibrovascularization was the largest with PE-g-RGD. The results of immunostaining of CD31, which is indicative of the degree of vascularization, showed that the RGD-immobilized surface could elicit more widespread fibrovascularization within the porous PE implants. This work demonstrates that the present surface modifications, viz. hydrophilic AA grafting and RGD peptide immobilization, can be very effective in inducing fibrovascular ingrowth into porous PE implants.

Convergence Technologies by a Long-term Case Study on Telepresence Robot-assisted Learning (텔레프리젠스 로봇보조학습 사례 연구를 통한 융합기술)

  • Lim, Mi-Suk;Han, Jeong-Hye
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.7
    • /
    • pp.106-113
    • /
    • 2019
  • The purpose of this paper is aimed to derive suggestions for convergence technology for effective management of distance education by analyzing a long-term case. The experiment was designed with notebook, smartphone or tablet based robot controlled by a remote instructor and a learner, who have experience of distance learning including robot assisted learning. The tablet based robot has the display system of feedback to speakers. During five months, three types of experiments were conducted randomly and a participant was interviewed thoroughly. The result, like the previous research, demonstrates that the task performance of the learner in telepresence robot-assisted learning was better than that in the notebook, and smartphone based. However, it is believed to be necessary to adjust the system for eye-contact and voice transmission for the remote instructor. The instructor required an additional sight by supplementing an extra camera and automatic direction control to source of sound.

The process of estimating user response to training stimuli of joint attention using a robot (로봇활용 공동 주의 훈련자극에 대한 사용자 반응상태를 추정하는 프로세스)

  • Kim, Da-Young;Yun, Sang-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1427-1434
    • /
    • 2021
  • In this paper, we propose a psychological state estimation process that computes children's attention and tension in response to training stimuli. Joint attention was adopted as the training stimulus required for behavioral intervention, and the Discrete trial training (DTT) technique was applied as the training protocol. Three types of training stimulation contents are composed to check the user's attention and tension level and provided mounted on a character-shaped tabletop robot. Then, the gaze response to the user's training stimulus is estimated with the vision-based head pose recognition and geometrical calculation model, and the nervous system response is analyzed using the PPG and GSR bio-signals using heart rate variability(HRV) and histogram techniques. Through experiments using robots, it was confirmed that the psychological response of users to training contents on joint attention could be quantified.

The Effect of Group Validation Therapy(V/T) in the Elderly with Dementia (집단인정치료(Group validation therapy)가 치매노인에게 미치는 영향에 관한 연구)

  • Chang, Woo-Shim
    • 한국노년학
    • /
    • v.28 no.4
    • /
    • pp.1023-1039
    • /
    • 2008
  • The purpose of this study was to develop a group validation therapy(V/T) which could be implemented for the elderly with dementia in nursing home, and to evaluate the effectiveness of the program on cognition, ADL(Activity of Daily Living), depression, problematic behavior and QOL(Quality of Life). Subjects were recruited from 4 nursing homes in D city. The sample comprised forty elderly with dementia, capable of verbal communication. Each twenty were in an experimental and control groups. However, four elders with dementia dropped out in experimental and control groups due to personal affairs. Experimental group completed twelve consecutive group validation therapy sessions that combined centering, asking factual questions, rephrasing, identifying and using the preferred sense, asking the extreme, imagining the opposite, reminiscing, touching, maintaining eye contact and a caring tone of voice, observing, matching and expressing the emotion with emotion, using ambiguity, linking behavior with a basic human need, using music and mirroring techniques. Following the intervention, experimental group experienced a significant improvement in cognition, ADL, depression, and QOL. But it is a nonsignificant in problematic behavior on statistically. As a result, a group validation therapy should be applied as an effective and practical psychosocial intervention for the elderly with dementia.

Rapid Progression to Brainstem Encephalitis Caused by Enterovirus 71 Without Throat and Skin Lesions After a One-Day Fever

  • Kyung Min Kim;Soo Yeon Kim;Mi Kyoung Song;Ji Young Kim;Anna Cho;Ji Young Park
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.2
    • /
    • pp.91-96
    • /
    • 2023
  • Infection with enterovirus (EV) 71 is usually associated with hand-foot-and-mouth disease and herpangina. The most frequent neurologic complication is brainstem encephalitis. A 30-month-old boy visited the pediatric emergency department with fever, lethargy, and abnormal eye contact. His mental status was slightly drowsy. On hospitalization day 2, the patient experienced respiratory arrest with apnea. Brain magnetic resonance imaging revealed bilateral symmetric T2-high signal lesions without enhancement in the posterior aspect of the brainstem and left medial temporal lobe. Electroencephalography was indicative of diffuse cerebral dysfunction with diffuse high amplitude and irregular delta activities. He underwent a gene study and was diagnosed with myoclonic epilepsy with ragged red fibers syndrome. We report a case of EV 71 brainstem encephalitis by polymerase chain reaction for nasopharyngeal aspirates and feces with rapid progression within one day of fever without the manifestation of throat and skin lesions because of his underlying mitochondrial disease.

A standardized procedure on building spectral library for hazardous chemicals mixed in river flow using hyperspectral image (초분광 영상을 활용한 하천수 혼합 유해화학물질 표준 분광라이브러리 구축 방안)

  • Gwon, Yeonghwa;Kim, Dongsu;You, Hojun
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.845-859
    • /
    • 2020
  • Climate change and recent heat waves have drawn public attention toward other environmental issues, such as water pollution in the form of algal blooms, chemical leaks, and oil spills. Water pollution by the leakage of chemicals may severely affect human health as well as contaminate the air, water, and soil and cause discoloration or death of crops that come in contact with these chemicals. Chemicals that may spill into water streams are often colorless and water-soluble, which makes it difficult to determine whether the water is polluted using the naked eye. When a chemical spill occurs, it is usually detected through a simple contact detection device by installing sensors at locations where leakage is likely to occur. The drawback with the approach using contact detection sensors is that it relies heavily on the skill of field workers. Moreover, these sensors are installed at a limited number of locations, so spill detection is not possible in areas where they are not installed. Recently hyperspectral images have been used to identify land cover and vegetation and to determine water quality by analyzing the inherent spectral characteristics of these materials. While hyperspectral sensors can potentially be used to detect chemical substances, there is currently a lack of research on the detection of chemicals in water streams using hyperspectral sensors. Therefore, this study utilized remote sensing techniques and the latest sensor technology to overcome the limitations of contact detection technology in detecting the leakage of hazardous chemical into aquatic systems. In this study, we aimed to determine whether 18 types of hazardous chemicals could be individually classified using hyperspectral image. To this end, we obtained hyperspectral images of each chemical to establish a spectral library. We expect that future studies will expand the spectral library database for hazardous chemicals and that verification of its application in water streams will be conducted so that it can be applied to real-time monitoring to facilitate rapid detection and response when a chemical spill has occurred.

Changes of Lens Morphology and TBUT by Dehydration of Soft Contact Lens (소프트콘택트렌즈 건조로 인한 렌즈 형태 및 TBUT의 변화)

  • Park, Mijung;Lee, Yu-Na;Kang, Kyu Eun;Lee, Min Ha
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • Purpose: This study was performed to evaluate the changes of lens morphology and tear stability during wearing soft contact lenses (SCLs) which were kept in drying condition like dry eye or became to be dried due to heedless care. Method: SCLs having different water content, thickness or material were rehydrated after being dehydrated artificially 2 or 4 times, and estimated their diameter and radius. Furthermore, the changes of tear film break-up time (TBUT) during SCL wearing were also measured. Result: Due to the dryness, the diameter of both 70% water content SCL and 59% water content SCL decreased, but the decrement was larger in 59% water content SCL. The more 59% water content SCL was dehydrated, the more its radius changed. However, the radius of 70% water content SCL did not change by 2 times dehydration and increased greatly by 4 times dehydration. The reduction of diameter of -1.00 D SCL was greater than that of -9.00 D SCL. Moreover, the radius of -1.00 D SCL increased depending on the frequency of dehydration but that of -9.00 D SCL did not changed. The diameter and radius changes of lotrafilcon B, silicone hydrogel lens, were less than those of hilafilcon B, copolymer of HEMA and N-vinyl pyrrolidone. TBUT during wearing SCLs decreased by wearing dehydrated SCLs. Conclusion: The diameter and radius of dehydrated SCLs as well as TBUT during wearing them were changed in spite of rehydration, which would be the important cause of uncomfortable feeling when people wore dehydrated SCL. The changes of SCL morphology and TBUT differed according to the water content, lens thickness and material.

  • PDF

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.