• Title/Summary/Keyword: Eye contact

Search Result 211, Processing Time 0.03 seconds

Eye Irritation Test of New Contact Lens Cleaner

  • Oh, Se-Woong;Ha, Jong-Ryul;Hong, Seong-Jin;Park, Kun-Hyock
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.274-274
    • /
    • 1996
  • 1차적인 제형의 조제를 위해서 비이온성 계면활성제인 poloxamer 류, Tween 류, octylphenylether와 양심 계면활성제인betaine 류와 방부제인 croquat 류에 대한 시험을 실시하여 자극을 나타내지 않은 성분을 선별하였다. 이를 근거로 isotonic sodium borate 용액을 완충액으로 사용하여, 최종제형을 조제하여 시험한 결과 자극반응을 나타내지 알았으며, 본 제형을 실온과 4$0^{\circ}C$에서 2, 4, 6개월간 안정성 시험을 거친 후 시험시에도 전혀 자극반응을 나타내지 않았다.

  • PDF

A Study on the Impact of Life Habits on Eyesight among College Students (centering on students studying Dental Technology) (대학생들의 생활습관이 시력에 미치는 영향에 관한 연구 - 치기공과 재학생을 중심으로 -)

  • Choi, Un-Jae;Jun, Jeong-Ja
    • Journal of Technologic Dentistry
    • /
    • v.32 no.4
    • /
    • pp.403-415
    • /
    • 2010
  • Purpose: The purpose of this study was to examine the eyesight and life habits of college students in an attempt to provide some information on the protection of their eyesight. Methods: The subjects in this study were 311 students in the department of dental technology at a college of health, on whom a survey was conducted. A crosstabulation analysis was carried out to show the joint distribution of general characteristics and several variables involving the use of glasses or contact lenses and life habits. Results: 77.5% of the students currently wore glasses due to weak sight. 9.3% took an eye test on a regular basis, and 31.2% did that every six months. As for the length of the length of daily mean reading time, 55.3% spent one hour or less reading books. The most common distance between eyes and books during their reading(44.7%) was 21 to 25. Concerning a reading posture, the biggest group(54.3%) lay down or lay on their face while they read books. 45.0 % spent less than an hour watching TV per day on average, and 27.0% were on the computer for 30 minutes to less than an hour per day on average. The greatest group(63.0%) made use of basic indoor lighting when they were on the computer at night, and 62.1% saw eye doctors to take an eye test. In relation to how to protect eyesight, the biggest group(50.5%) spent less time being on the computer. Conclusion: As the eyesight of college students fails due to reading, TV, computer, and improper ways and posture of doing or using those things, every college definitely should provide education on eye health as one of general education courses.

The Case Report of Soyangin Yangdokbalban (陽毒發斑) (형방사백산(荊防瀉白散)을 활용한 소양인 양독발반(陽毒發斑) 치험 1례)

  • Park, Geun-Hee;Kim, Oh-Young;Park, Hye-Sun
    • The Journal of Korean Medicine
    • /
    • v.32 no.4
    • /
    • pp.159-166
    • /
    • 2011
  • Objectives: This study reports using Hyungbangsabaksan to cure Soyangin Yangdokbalban (陽毒發斑) appealing Systemic Allergic Contact Dermatitis. Methods: After diagnosing the patient showing Papuloerythematous with no blisters in the body as a Soyangin Yangdokbalban (陽毒發斑), we prescribed the patient with Hyungbangsabak-san. We compared the condition of the patient before and after medication with photo shots. Results: After treatment, Papuloerythematous which was seen with the naked eye disappeared and various skin symptoms such as itching and warmth in the flare area also improved. Conclusions: After treatment, the symptoms of the patient who after eating lacquer chicken showed improvement.

Contact lens Prescription and Satisfaction with Astigmatism Eye (난시안의 콘택트렌즈 처방과 만족도에 관한 연구)

  • Kim, Mi-Yeon;Kim, Yeong-Mi;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.317-322
    • /
    • 2006
  • For this study we made up a question investigation to analyze a grade of satisfaction and a side effect about the prescription actual condition of contact lens of person with astigmatism among the person who has a error of refraction. The whole patient of refractive error was 46 person, there were 11 person who only wear spectacles by correction of visual acuity among person to a question investigation and 35 person who only wear contact lens. Under investigation 35 person who only wear contact lens, there were 25 person who experience the problem which occurs because of contact lens wearing for a long time. The most patient who made up a question investigation very choose remainder item except for item of very satisfaction. The their reason that could not satisfaction was non corrected astigmatism, wrong prescription, wrong Base curve, out of life span etc.

  • PDF

A Case of Contact Dermatitis by Pain Relieving Patch Deteriorated after Taking Lotus Root (파스 접촉 알레르기 치료 중 연근 복용 후 악화된 중등도 알레르기 피부 1례)

  • Lim, Kyeong-Min;Choi, Jung-Hwa;Park, Soo-Yeon;Kim, Jong-Han;Kim, Seon-Jong;Shin, Jeong-Cheol;Jung, Min-Yeong
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.28 no.3
    • /
    • pp.126-134
    • /
    • 2015
  • Objectives : The purpose of this study is to report that Korean medical treatment is good for deteriorated moderate allergic skin after taking lotus root while getting treatment for contact dermatitis by pain relieving patch.Methods : A 54-year-old woman patient with allergic contact dermatitis received treatment with acupuncture, herbal medicine, etc. We used observation and Visual Anologue Scale(VAS) to evaluate recovery from erythema, pruritus and skin damages.Results : A visible symptoms to the naked eye and VAS scale were effectively decreased after Korean medicine treatments.Conclusions : Korean medical treatments were effective for allergic contact dermatitis deteriorated by lotus root while getting treatment contact dermatitis by pain relieving patch.

Micro-channel Embedded Soft Contact Lens for Tear Biomolecule Sampling (눈물의 생체 분자 추출을 위한 미세유관이 탑재된 유연한 콘택트 렌즈)

  • Kim, Ockchul;Park, HyungDal;Song, Young-won;Kim, Jinseok
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.178-185
    • /
    • 2016
  • Tear is a promising biological fluid for non-invasive health monitoring. It has been studied in the past to be a possible candidate for the diagnosis of certain systemic diseases, such as breast cancer, multiple sclerosis, prostate cancer, and diabetes. However, currently existing methods for collecting and extracting tear from the human eye causes inconsistencies in the biomolecule concentrations of the tear sample due to the irritating nature of the process. In response, we designed and fabricated a microfluidic system embedded soft contact-lens for the purpose of tear sampling. The lens was then tested with artificial tear for its tear sampling capability, and found to be able to find concentration equilibrium within 50 minutes. Additionally, simulation was carried out to further optimize the design so that tear sampling rate matched the natural tear turn-over rate of 1 microliter per minute.

Thermographic Assessment in Dry Eye Syndrome, Compared with Normal Eyes by Using Thermography (열화상카메라를 이용한 정상안과 건성안의 서모그래피 비교)

  • Park, Chang Won;Lee, Ok Jin;Lee, Seung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Purpose: The purpose of this study was to compare and analyze the ocular surface and the palpebral conjunctiva of categorized subjects, which were divided into normal eye group and dry eye group, by using a thermal camera. Methods: Subjects were 144 eyes of 72 normal university students, who didn't have any corneal disease, abnormal lacrimal ducts, medical records regarding ocular surgeries, or experience of using contact lens. Subjects were divided into two groups, which were normal eye group and dry eye group, based on the results of TBUT, Schirmer I test, and McMonnies test. After categorizing the subjects, the temperature of the subjects' ocular surface and the palpebral conjunctiva were measured and analyzed by using a thermal camera (Cox CX series, Answer co., Korea). Results: In the normal eye group's Central Ar.1, Nasal Ar.2, Temporal Ar.3, Superior Ar.4, Inferior Ar.5, the measured amount of temperature change on each area was $-0.13{\pm}0.08$, $-0.14{\pm}0.08$, $-0.12{\pm}0.08$, $-0.14{\pm}0.08$, $-0.10{\pm}0.09(^{\circ}C/sec)$. The dry eye group's results were $-0.17{\pm}0.08$, $-0.16{\pm}0.07$, $-0.16{\pm}0.08$, $-0.17{\pm}0.09$, $-0.15{\pm}0.08(^{\circ}C/sec)$. When compared with the normal eye group, the values of Ar.1, Ar.3, Ar.5 were significantly different in the dry eye group(p<0.05). The amount of temperature change, which was observed on the palpebral conjunctiva(Ar.1:central, Ar.2: nasal, Ar.3: temporal) of the normal eyes, measured by thermography, was $34.36{\pm}1.12$, $34.17{\pm}1.10$, $34.07{\pm}1.12^{\circ}C$ on each area. Same values taken from the dry eye group was $33.55{\pm}0.94$, $33.43{\pm}0.97$, $33.51{\pm}1.06^{\circ}C$ on each area. The values of Ar.1, taken from the dry eye group, had a significant difference, compared to the values of the normal eye group(p=0.05). Conclusion: The temperature of the ocular surface decreased faster on the dry eyes, compared to the normal eyes. The temperature measured on the palpebral conjunctiva of the dry eyes were also lower than the normal eyes. The temperature changes on the ocular surface, observed with a thermal camera, were objective values to assess the stability of tear films, and might provide useful data for studies related to dry eye syndrome.

Survey on Contact Lens Wear Status in Gyeonggido (경기도 지역 콘택트렌즈 착용실태 조사)

  • Song, Yun-Young;Oh, Hyun-Jin;Jung, Mi-A
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.373-378
    • /
    • 2014
  • To investigate the wear status of contact lenses by analyzing care of contact lenses container and actual condition of people wearing contact lenses and in Gyeonggido. The results were based on a questionnaire survey of 200 people who are the students of the middle school, the high school and the college among the clients of opticians to purchase contact lenses for six months from January 2013 to July 2013. According to the poll, the highest number of those polled, 139 (55.16%) people, said they were wearing cosmetic color contact lenses. Female respondents and male respondents were in the proportion of 177 (88.5%) to 23 (11.5%), respectively. 37 people (18.5%) who responded said "yes" to the question of them sharing contact lenses and glasses. 103 people (51.5%) answered "no" to the question of regularly replacing their lens containers. 148 people (74%) answered "yes" to the question of having glasses in order to investigate contact lens wearers user rate of glasses. The highest number of respondents, 127 people (63.5%), said "middle school" was the first time that they wore contacts. Meanwhile, 65 people (43.92%) said they initiated wearing glasses at 4th-6th grades. It is considered that it is necessary using proper contact lenses suitable for the clients' eye health in order of vision correction, rather than for cosmetic purposes. The role of the optician is considered to be very important for the proper management of the appropriate contact lens hygiene and regular optical check-ups of the contact lens wearers.

The Effects of Spherical and Aspherical RGP Contact Lenses on Visual Performance (구면 및 비구면 RGP 콘텍트렌즈가 시력의 질에 미치는 영향)

  • Kim, Soo-Hyun;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2009
  • Purpose: This study was to evaluate corneal topography, contrast sensitivity and ocular response of a RGP, back surface aspherical contact lens compared with a spherical contact lens. Methods: A total 37 subjects were fitted with a spherical lens in right eye and an aspherical in the left eye and were evaluated for changes in corneal topography and contrast sensitivity over a 2-month period. Results: Thirty-four of 37 subjects completed the 2-month study. The corneal topography did not show differences between spherical and aspherical RGP lenses. The eyes fitted with the aspherical lenses demonstrated a greater reduction in contrast sensitivity compared with their spherical counterparts under photopic condition. Subjects preferred comfort and ocular responses provided by the spherical lens. Conclusions: Corneal topography when comparing spherical and back surface aspherical RGP lenses did not show any significant difference in the subjects. Spherical RGP lens yields better contrast sensitivity and preference than aspherical RGP lens at photopic condition. Further investigation of aberrations induced by contact lens design is warranted to explain the observed differences in visual performance.

  • PDF

A Study of Ultrastructure on attachment of Soft Contact Lens Surface of Incubated Pseudomonas aeruginosa (배양된 Pseudomonas aeruginosa의 소프트 콘택트 렌즈 표면부착에 대한 미세구조적 연구)

  • Kim, Douk Hoon;Park, Yong Tae;You, Hae Byung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.11-14
    • /
    • 2000
  • The soft contact lens was very simple technique in handling, good sensation in fitting, good effect of a beauty, and good attachment state on the cornea in physical movement. So that, the subjects have used the correct of visual acuity. If the contact lens handling have not skill, they have acquired the side effect on eye. To analysis of a study of ultrastructure on soft contact lens surface of incubated P. aeruginosa. We have observed the soft contact lens surface by SEM. We have founded the good technical method. On the method of sample process of manufacture, the best observation of samlpe tissue was $OsO_4$ postfixation and tannic acid treatment. In this case, P. aeruginosa was a rod shape and one cilia in ultrastructure and the identification was very good. But, On the process of manufacture have not used the $OsO_4$ and tannic acid treatment, this tissue sample appeared the foreign body materials and artifacts, and the identification of the P. aeruginosa was very difficult.

  • PDF