• Title/Summary/Keyword: Eye blinking

Search Result 51, Processing Time 0.038 seconds

Driver's Eye Blinking Detection Method based on Template Matching using Line Profile (라인 프로파일을 이용한 템플릿 매칭 기반의 운전자 눈 깜박임 검출 방법)

  • Kim, Young Jae;Shin, Seung Seob;Kim, Kwang Gi
    • Journal of Korea Multimedia Society
    • /
    • v.20 no.6
    • /
    • pp.873-881
    • /
    • 2017
  • Prevention of drowsy driving is one of the important issues for safe driving. In this study, the algorithm for detection of drowsy driving has been developed. The algorithm was implemented by applying template matching and line profile, which detects eye blink. The accuracy of eye detection and blink detection was $97.45{\pm}3.67%$ and $98.50{\pm}0.92%$, which was resulted from the verification experiment that 21 subjects participated. Consequently, the algorithm is expected to be used to prevent sleep-deprived driving.

Eye Blink Detection and Alarm System to Reduce Symptoms of Computer Vision Syndrome

  • Atheer K. Alsaif;Abdul Rauf Baig
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.5
    • /
    • pp.193-206
    • /
    • 2023
  • In recent years, and with the increased adoption of digital transformation and spending long hours in front of these devices, clinicians have observed that the prolonged use of visual display units (VDUs) can result in a certain symptom complex, which has been defined as computer vision syndrome (CVS). This syndrome has been affected by many causes, such as light refractive errors, poor computer design, workplace ergonomics, and a highly demanding visual task. This research focuses on eliminating one of CVSs, which is the eye dry syndrome caused by infrequent eye blink rate while using a smart device for a long time. This research attempt to find a limitation on the current tools. In addition, exploring the other use cases to utilize the solution based on each vertical and needs.

Visual Fatigue Study of Active Senior (액티브 시니어의 시각 피로도 연구)

  • Cho, Hyesuk;Na, Yoonhye;Sim, Youngbo;Lee, Jangwoo;Park, Kunwoo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.18-26
    • /
    • 2018
  • This study aimed to examine whether there was difference on visual fatigue between active seniors and young people, and to provide a guideline for appropriate computer use time for seniors. Blinking rate, maximal blinking interval, temperature of the ocular surface, visual fatigue questionnare were evaluated. The blinking rate, ocular surface temperature, visual fatigue showed significant change before and after the tasks. There was no difference between the two groups and thus, about 30-minute computer work appeared to be appropriate for seniors.

The effects of short persistent CCFL in Blinking Back Light Unit to reduce blur on TFT-LCD

  • Han, J.M.;Bae, K.W.;Kim, S.Y.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.694-697
    • /
    • 2003
  • In applying LCD to TV application, one of the most significant factors to be improved is image sticking on the moving picture. LCD is different from CRT in the sense that it's continuous passive device, which holds images in entire frame period, while impulse type device generate image in very short time. To reduce image sticking problem related to hold type display mode, we made an experiment to drive LCD like CRT. We made articulate images by turn on-off backlight, and we realized the ratio of Back Light on-off time by adjusting between on time and off time for video signal input during 1 frame (16.7ms). Conventional CCFL (cold cathode fluorescent lamp) cannot follow fast on-off speed, so we evaluated new fluorescent substances of light source to improve residual light characteristic of CCFL. We realized articulate image generation similar to CRT by blinking drive. As a result, reduced image sticking phenomenon was validated by naked eye and response time measurement.

  • PDF

Implementation of A Safe Driving Assistance System and Doze Detection (졸음 인식과 안전운전 보조시스템 구현)

  • Song, Hyok;Choi, Jin-Mo;Lee, Chul-Dong;Choi, Byeong-Ho;Yoo, Ji-Sang
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.49 no.3
    • /
    • pp.30-39
    • /
    • 2012
  • In this paper, a safe driving assistance system is proposed by detecting the status of driver's doze based on face and eye detection. By the level of the fatigue, safe driving system alarms or set the seatbelt on vibration. To reduce the effect of backward light and too strong solar light which cause a decrease of face and eye detection rate and false fatigue detection, post processing techniques like image equalization are used. Haar transform and PCA are used for face detection. By using the statistic of the face and eye structural ratio of normal Koreans, we can reduce the eye candidate area in the face, which results in reduction of the computational load. We also propose a new eye status detection algorithm based on Hough transform and eye width-height ratio, which are used to detect eye's blinking status which decides doze level by measuring the blinking period. The system alarms and operates seatbelt on vibration through controller area network(CAN) when the driver's doze level is detected. In this paper, four algorithms are implemented and proposed algorithm is made based on the probability model and we achieves 84.88% of correct detection rate through indoor and in-car environment experiments. And also we achieves 69.81% of detection rate which is better result than that of other algorithms using IR camera.

Comparison Among the Four Examination Methods for Dry Eye (OQAS test, TBUT, Schirmer Test, McMonnies test) (4가지 건성안 분석방법(OQAS test, TBUT, Schirmer test, McMonnies test)의 비교)

  • Park, Chang Won;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.519-526
    • /
    • 2015
  • Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.

A Study of the Variation Factors of Intraocular Pressure (안압 변동 요인에 관한 연구)

  • Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.131-135
    • /
    • 2008
  • Purpose: To measure and quantify the factors of intraocular pressure (IOP) variation for normal Korean youth. Methods: The IOP of normal youth 805 persons (male: 367, female: 438) were measured as a function of time and quantity for fixation, reclining posture, hard blinking, drinking water, drinking hard liquor, tobacco and coffee by using non-contact tonometer (AT555, Reichert Co.). In the case of fixation, reclining posture and hard blinking, the intraocular pressure of right and left eye were measured for 6 males and 6 females every 10 minutes during 30 minute. In the case of water, liquor, tobacco and coffee, the measurement for 4 or 5 groups (6 persons/ group) having similar IOP were done for the IOP variation of right eye. Results: The mean IOP was 15.2 mmHg for males and 15.8 mmHg for females (slightly higher than male's), respectively and the 99% of those were in the range of the normal IOP. The measured IOP was increased by fixation, reclining posture and hard blinking with males and females. The gradient of increasing slope was 0.15/0.13/0.07/0.08, 0.09/0.08/0.08/0.08 and 0.19/0.08/0.26/0.31, respectively. The IOP variation was elevated by drinking water (especially in the case of 1000 ml) and lowered in proportion to the amount of drinking by hard liquor. Cigarette smoking was associated with rise in intra ocular pressure, but was not shown a definite relation. And coffee had virtually no effect. Conclusions: Fixation, reclining posture, hard blinking and Tobacco caused a transient increase in IOP, but alcohol elicited a slight reduction in IOP overall.

  • PDF

The Comparison of Lens Movement by the Fitting States of Soft Contact Lenses in Normal and Dry Eyes (정상안과 건성안에서 피팅상태에 따른 각막에서의 소프트렌즈 움직임 비교)

  • Jung, Da I;Lim, Shin Kyu;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.21-30
    • /
    • 2011
  • Purpose: The study was performed to compare the differences in lens rotation, lens movement by blinking and lens centration with alignment or steep fitting of soft contact lens in normal and dry eyes. Methods: Total 40 eyes (aged 20~30 years) were classified into the normal (n=20) or dry eye group (n=20) by the diagnosis methods for dry eyes and worn soft contact lens (polymacon material) with alignment fitting or steep fitting. Lens rotation, lens movement by blinking and lens centration were separately measured immediately after lens wearing and after stabilization of tear film and compared by fitting states of soft contact lenses. Results: With steep fitting of soft contact lens in dry eyes, averaged lens rotation immediately after lens wearing was not significantly different from that of the normal eye group with alignment fitting however, lens rotation after stabilization in dry eyes was significantly larger than that in normal eyes. Any significant difference in lens movement by blinking was not shown in normal eyes. However, lens movement by blinking in dry eyes was increased with steep fitting. The range of lens centration on cornea in normal eyes with alignment fitting was more vertically distributed. On the other hand, the range of lens centration on cornea in dry eyes with alignment fitting was more horizontally distributed. Lens centration was shown to be changed by stabilization of tear film. That is, lens centrations were somewhat vertically widespread immediately after lens wearing and restrictively distributed in horizontal direction, respectively, with steep fitting in dry eyes. Conclusions: These results suggested that lens movements and centration in dry eyes were different from those of normal eyes. Especially, those differences between normal and dry eyes were much bigger with steep fitting of soft contact lenses. Thus, those differences should be considered for the comfortable and safe fitting of soft contact lens in dry eyes.

Artifacts characteristic analysis of EEG (EEG의 잡파 특성 분석)

  • 양은주;조한범;김응수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.05a
    • /
    • pp.87-90
    • /
    • 2002
  • 뇌파(Electroencephalogram, EEG)는 뇌 신경세포가 정보를 처리하는 과정에서 발생하는 전기적인 신호를 두피 표면에서 측정한 것이다. 이러한 뇌파는 비침습적인 방법으로 전기적인 신호를 측정하며 측정시 여러 잡파(artifact)가 섞이기 쉽다. 이러한 잡파는 뇌의 정보처리과정에 대한 유용한 정보를 담고 있는 뇌파를 분석하는데 방해가 되므로 이를 제거하기 위한 노력이 계속되어 왔다. 그러나 본 연구에서는 보다 적극적인 방향으로 잡파가 섞인 뇌파의 특성을 분석하여 이를 통해 제어 시스템 등과 같은 시스템에 적용할 수 있는 가능성을 알아보았다. 대표적인 잡파인 eye_blinking, eye_rolling, muscle 등이 각각 포함된 뇌파에 대해서 선형 및 비선형 분석을 실시함으로써 유의미한 특성 차이를 나타내었다.

  • PDF

Alternative Treatment for Facial Nerve Paralysis in a Dog

  • Abdel-Rahman, Hassan-Abdel-Rahman;Jun, Hyung-Kyou;Song, Kun-Ho;Kang, Jun-Gu;Kim, Duck-Hwan
    • Journal of Veterinary Clinics
    • /
    • v.25 no.6
    • /
    • pp.526-528
    • /
    • 2008
  • A 4-year-old male Maltese dog was referred with chief complaint of facial nerve paralysis and hyperthermia. These clinical signs were occurred after tooth extraction. Leukocytosis and swelling of left side of gums were detected. He was medicated with antibiotics for 9 days, however, inability of blinking in left eye, lacrimation and hyperthermia were not improved. The patient was administrated with Oyaksungisan (50 mg/kg, PO, BID) for 14 days and was treated by injection-acupuncture (AP) with bee venom ($200\;{\mu}g/head$, two times/week, total three times). The patient was treated by injection-AP with dexamethasone (1 mg/kg, two times/week, total two times). As a result, Left blepharon was slightly blinked at session 4. Blinking of left blepharon became normal after session 5. The present patient was a case with canine facial nerve paralysis which showed favorable therapeutic response by alternative treatment.