• Title/Summary/Keyword: Eye Test

Search Result 832, Processing Time 0.023 seconds

A Comparative Study between Korean Standard Eye Test and Test Chart 2000 Pro (Test Chart 2000 Pro와 한국 표준 검안법의 일치도 비교 연구)

  • Kang, Ji-Hun;Kim, Dal-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.69-80
    • /
    • 2009
  • Purpose: We investigated validity of a monitor-based computer eye test program, Test Chart 2000 Pro (developed by Thomson Software Solutions, UK). Methods: We chose ten common eye tests of the Test Chart 2000 Pro and Korean Standard Eye Test, applying them to same subject groups each by each, followed by comparison and analyses of agreement degree of the results. Results: Among the ten eye tests, Snellen Chart, Cross-cyl target, Duochrome test, Fan and Block test, and Random dot stereograms showed statistically significant agreement between both the Korean standard eye test method and Test Chart 2000 Pro. On the other hand, some disagreements were found between the two eye test methods in LogMAR Chart, Single Letter Chart, Phoria Test, Fixation Disparity Test, and Worth 4 Dot Test. Conclusions: Comparing to the Korean Standard Eye Test that consists of Han eye chart and Phoroptor, validity of the Test Chart 2000 Pro is not so high. Further improvements of the Test Chart 2000 Pro in accuracy are required.

  • PDF

Effect of Eye Drop Education on Adherence to Glaucoma Medication (점안 지도가 항녹내장 안약의 처방 순응도에 미치는 영향)

  • Park, Kyung-Ji;Song, Hyun Ju;Sohn, Uy Dong
    • YAKHAK HOEJI
    • /
    • v.57 no.2
    • /
    • pp.139-149
    • /
    • 2013
  • Glaucoma is a potentially blinding chronic disease requiring life-long commitment to medical therapy. Failure to adhere to anti-glaucoma treatment may lead to disease progression and visual loss. This study surveyed the adherence to glaucoma eye drop and eye drop instillation technique of glaucoma patients and analyzed the improvement of the adherence and installation technique after patient education for eye drop instillation instructions. Collected responses were statistically analyzed using Kruskal-Wallis test, Mann-Whitney test, Chi-square test, Fisher's exact test, Spearman's correlation coefficient, or one sample proportion test. The survey after patient education for proper eye drop instillation revealed that, even if the patients experienced the adverse effect of their eyes getting dry, they used the eye drop more regularly. They were better at instillation techniques like putting the eye drop inside the eye, and also avoiding applying too much medication or touching their eye with the eye drop bottle. Also, when the patients were divided into groups based on etiologic division, there was difference among groups regarding which category they answered has improved. The result showed improvement in adherence to glaucoma eye drop and eye drop instillation technique after patient education, implicating that patient education is an important aspect of eye care for glaucoma patient and helps them participate in the proper management.

Eye Irritation Test of Fel Ursi Pharmacopuncture Solutions for Eye Drop (점안용 웅담약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.93-97
    • /
    • 2008
  • Objective: This study was done to investigate the safety of Fel Ursi pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods: The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, the author observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results: 1. After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Fel Ursi pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions: I suggested that Fel Ursi pharmacopuncture solution didn't induced eye irritation in rabbits.

Eye Irritation Test of Fel Ursi & Bovis Calculus Pharmacopuncture Solutions for Eye Drop (점안용 웅담.우황약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.99-104
    • /
    • 2008
  • Objective: This study was done to investigate the safety of Fel Ursi & Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods: The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the author observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results: 1. After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Fel Ursi & Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions: I suggested that Fel Ursi & Bovis Calculus pharmacopuncture solution didn't induced eye irritation in rabbits.

Eye Irritation Test of Soyeom Pharmacopuncture Solution for Eye Drop (점안용 소염약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.2
    • /
    • pp.75-79
    • /
    • 2008
  • Objectives This study was done to investigate the safety of Soyeom pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results 1. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Soyeom pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions I suggested that Soyeom pharmacopuncture solution didn't induced eye irritation in rabbits.

Eye Irritation Test of Bovis Calculus Pharmacopuncture Solutions for Eye Drop (점안용 우황약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.2
    • /
    • pp.81-85
    • /
    • 2008
  • Objective This study was done to investigate the safety of Bovis Calculus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration (2005. 10. 21, KFDA 2005-60). After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, the auther observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results 1. After Bovis Calculus pharmacopuncture solution was medicated in the left eye of the rabbits, there wasn't physical problem at 9 rabbits. 2. After Bovis Calculus pharmacopuncture solutionwas medicated in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions I suggested that Bovis Calculus pharmacopuncture solution didn't induced eye irritation in rabbits.

Analysis of Eye Movement by the Science Achievement Level of the Elementary Students on Observation Test (관찰 문제에서 초등학생의 과학 학업성취도에 따른 안구운동 분석)

  • Shin, Won-Sub;Shin, Donghoon
    • Journal of Korean Elementary Science Education
    • /
    • v.32 no.2
    • /
    • pp.185-197
    • /
    • 2013
  • The purpose of this study was to analyze the difference between eye movements according to science achievement of elementary school students in observation situation. Science achievement was based on the results of national achievement test conducted in 2012, a random sampling of classes. As an assessment tool to check observation test, two observation measure problems from TSPS (Test of Science Process Skill; developed in 1994) suitable for eye tracking system are adopted. The subjects of this study were twenty students of sixth grade who agreed to participate in the research. SMI (SensoMotoric Instruments)' iView $X^{TM}$ RED was used to collect eye movement data and Experiment 3.1 and BeGaze 3.1 program were used to plan and analyze experiment. As a result, eye movements in observation test varied greatly in fixation duration, frequency, saccade, saccade velocity and eye blink according to students' science achievement. Based on the result of eye movements analysis, heuristic search eye movement was discussed as an alternative to improve underachievers' science achievement.

Surveying and the Ergonomic Analysis of Eye Dominance (주시(Eye Dominance)에 관한 조사 및 인간공학적 분석)

  • 정화식
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.2
    • /
    • pp.79-89
    • /
    • 2004
  • It is known that most people have a dominant eye, even though each of their two eyes in isolation may provide equal vision. In this study, 600 Korean male and female subjects aging from 11 to 78 were selected to investigate the various statistics about eye dominance( whether the left or right eye is dominant} in Korean and their employment characteristics of preferred eye in sighting diverse things. A simple sighting test was applied such that subjects are requested to aim a distance target through small hole in B4 sized paper with both eyes open. The dominant eye was determined by alternate occlusion: when viewing with the dominant eye into the hole is aligned with the target, whereas when viewing with the other eye into the hole appears offset to one side. The descriptive statistics showed that 83.7% and 16.3% were right and left eye dominant respectively. Moreover, various statistical analysis revealed that general tendency of eye dominance was varied by age, gender, hand dominance and visual acuity. It was thus found from these results that people sighting their eyes differently depending on the eye dominance when they sight things.

Eye Irritation Test of Fel Ursi, Bovis Calculus & Moschus Pharmacopuncture Solutions for Eye Drop (점안용 웅담.우황.사향 약침액의 안점막자극실험)

  • Seo, Hyeong-Sik
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.105-111
    • /
    • 2008
  • Objective: The aim of this study is to investigate the safety of Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution manufactured with freezing dryness method to use eye drop. Methods: The eye irritation test of this material was performed according to the Regulation of Korea Food & Drug Administration(2005. 10. 21, KFDA 2005-60). After Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution was applied eyewash in the left eye of the rabbits, the author observed eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Results: 1. After Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution was applied eyewash in the left eye of the rabbits, there wasn t physical problem at 9 rabbits. 2. After Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution was applied eyewash in the left eye of the rabbits, there wasn't eye irritation of the cornea, iris, conjunctiva at 1, 2, 3, 4 & 7day. Conclusions: In this study, it was observed that Fel Ursi, Bovis Calculus & Moschus pharmacopuncture solution didn't induced eye irritation in rabbits.

Effects of eye dominance on shade matching and color perception among the dentist population

  • Pattnaik Kalyani;Kannan Subiksha;Amit Jena;Govind Shashirekha;Saumyakanta Mohanty;Gaurav Sharma
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.4
    • /
    • pp.40.1-40.8
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of eye dominance on color perception, and shade matching. Materials and Methods: A total of 104 participants were selected for the study. There were 3 groups: Group I: 3rd and 4th year dental students and interns (n = 40); Group II: postgraduates (n = 34); Group III: senior residents and faculty members (≥ 6 years of clinical experience) (n = 30). All participants were evaluated for congenital color blindness with Ishihara plates, their dominant eye with Mile's test, and their color perception with the Farnsworth-Munsell 100 hue test. The shade guide test was used for shade matching with a second corresponding set of Vitapan classical shade guides. Results: The results of Mile's test revealed that 60.6% were right-eye dominant and 39.4% were left-eye dominant. There was a statistically significant difference among all participants between the dominant eye and the non-dominant eye in shade matching. Conclusions: The dominant eye has a positive effect on shade matching and the ability to match shades becomes better with an increase in clinical experience.