• Title/Summary/Keyword: Extremely Low Frequency Magnetic Field

Search Result 68, Processing Time 0.027 seconds

Proteomic analysis of murine peritoneal macrophages after in vitro exposure to static magnetic field

  • Soon, Eun-Jae;Woong, Ko-Dae;Geun, Kwak-Young
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.113-113
    • /
    • 2003
  • A number of studies have demonstrated recently nonthermal interactions of extremely low frequency electromagnetic fields with cellular systems, such as the cells of the immune system. Particular concern came from epidemiological findings, which correlated environmental exposure of human body to weak electromagnetic fields with an elevated risk for developing certain type of leukemias and cancers. Several home/environmental sources generating extremely low frequency electromagnetic fields, such as 50 - 60 Hz high-voltage transmission lines, video display terminals, electric blankets, clinical nuclear magnetic resonance imaging procedures, etc., may interact with the human body. In this study we examined the effects of static magnetic fields (SMF) on the phagocytosis of the murine peritoneal macrophages (C57BL/6). The cells were exposed in vitro for 24 h at 37$^{\circ}C$ to 400 G SMF. The phagocytic activity of peritoneal macrophages was determined with a luminometer. Exposure to the SMF decreased phagocytic activity of murine peritoneal macrophages. In order to provide a more exact mechanism of the phenomenon, we analyzed peritoneal macrophages for alteration in their proteomes. The expression levels of these 5 proteins were increased in the SMF. In total 5 proteins which were differentially expressed in the SMF compared with control group were identified. The expression levels of these 5 proteins were increased in the SMF.

  • PDF

A Study on Characteristics and Safety Criteria for Human Body in ELF Electric and Magnetic Fields (ELF 전자계 특성 및 인체 안전기준에 관한 연구)

  • 김두현;김상철
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.3
    • /
    • pp.34-43
    • /
    • 1993
  • This paper presents a study on the characteristics and safety criteria for human body in ELF (Extremely Low Frequency : 50-60Hz) electric and magnetic fields. Many researches for ELF electric and magnetic fields, which are developed in the past, are studied and analyzed In this paper. In order to estabilish the safety criteria for human body in the field, the field intensity, induced current and voltage are calculated by the electrostatic field approach which is far simpler than the electromagnetic field one based on Maxwell equation. The method is applied to the 345 KV transmission line system In operation and 765 KV system under consideration. According to the results, the maximum value of field intensity, 6.8627KV/m, is evaluated at the location which is 14m away from transmission line. As the safety criteria value by the abroad researches asserting that the human can detect the Induced current in 6KV/m and above, 5KV/m and 7KV/m are recommended at residence area and nonresidence area, respectively.

  • PDF

Study on Standardization of the Environmental Impact Evaluation Method of Extremely Low Frequency Magnetic Fields near High Voltage Overhead Transmission Lines (고압 가공송전선로의 극저주파자기장 환경영향평가 방법 표준화에 관한 연구)

  • Park, Sung-Ae;Jung, Joonsig;Choi, Taebong;Jeong, Minjoo;Kim, Bu-Kyung;Lee, Jongchun
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.658-673
    • /
    • 2018
  • Social conflicts with extremely low frequency magnetic field(ELF-MF) exposures are expected to exacerbate due to continued increase in electric power demand and construction of high voltage transmission lines(HVTL). However, in current environmental impact assessment(EIA) act, specific guidelines have not been included concretely about EIA of ELF-MF. Therefore, this study conducted a standardization study on EIA method through case analysis, field measurement, and expert consultation of the EIA for the ELF-MF near HVTL which is the main cause of exposures. The status of the EIA of the ELF-MF and the problem to be improved are derived and the EIA method which can solve it is suggested. The main contents of the study is that the physical characteristics of the ELF-MF affected by distance and powerload should be considered at all stages of EIA(survey of the current situation - Prediction of the impacts - preparation of mitigation plan ? post EIA planning). Based on this study, we also suggested the 'Measurement method for extremely low frequency magnetic field on transmission line' and 'Table for extremely low frequency magnetic field measurement record on transmission line'. The results of this study can be applied to the EIA that minimizes the damage and conflict to the construction of transmission line and derives rational measures at the present time when the human hazard to long term exposure of the ELF-MF is unclear.

Extremely Low Frequency Magnetic Field is an Environmental Stress Factor by Exerting Oxidative Stress

  • Park, Yong-Jin;Park, Won-Joo;Yim, Sung-Hyuk;Yang, Seong-Jun;Sun, Yuan Lu;Jeong, Ji-Hoon;Park, Eon-Sub
    • Biomolecules & Therapeutics
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2007
  • The previous study reported the biological effect of magnetic field exerted by acting on endocrine and anti-oxidant system. The present study aims to study whether ELF-MF (extremely low frequency magnetic field) affects the physiological endocrine systems such as thyroid and whether ELF-MF affects the defense system against oxidative stress when it alters the function of thyroid. Finally, we correlate the effects of MF on oxidative stress, and adrenal and thyroid with an environmental stress factor. We exposed sham or MF to rats for 5 or 25 days. After the exposure, we determined pain sensitivity, level of TSH, $T_3$ and free $T_4$ in plasma. We also assayed in whole brain, lipid peroxidation, the activity of enzymatic anti-oxidant defense including superoxide dismutase(SOD) and glutathione peroxidase (GPx), and non enzymatic defense such as reduced or oxidized glutathione contents. MF induced the hypersensitivity to thermal stimuli with the reduction of latency. $T_3$ and $T_4$ levels were also increased by the exposure of MF. In addition, we observed the rise of MDA level in rat brain by MF although the MF did not change superoxide dismutase and glutathione peroxidase activity. The effect of MF on both reduced and oxidized glutathione results in decrease in reduced or oxidized glutathione in whole brain. In every experiment, there was no significant difference in MF influence between short term (5 days) and long term (25 days) exposure. Taken together, MF exposure affects the thyroid hormonal control in brain. The elevated thyroid hormone acts on brain, leading to hyper-utilization of oxygen. This phenomenon may be correlated with oxidative stress resulting from MF exposure. In conclusion, we suggest that MF exposure may be an environmental stress by exerting oxidative stress.

Biological effects of electromagnetic fields at extremely low frequencies (극저주파(Extremely Low Frequency : ELF) 대 전자기장(Electromagnatic field)의 생물학적 영향)

  • Chung, Hai-Won
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.3
    • /
    • pp.187-200
    • /
    • 1995
  • This paper reviews studies on potential health effects of electric and magnetic fields at extremely low frequencies(ELF). Recent studies focus on the epidemiological investigation of cancer, reproductive outcome and neurobehavioral effects due to residential and occupational exposure to ELF. Laboratory experiments are also carried out to find the possible mechanism of biological effects of ELF. Firm conclusion regarding whether ELF cause cancer are not yet conclusive but suggestive and other health effects of exposure to ELF have also been suggested but the evidence is even weaker than that related to cancer.

  • PDF

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

Measurements of Auditory Evoked Neuromagnetic Fields using Superconducting Quantum Interference Devices (SQUID를 이용한 뇌 청각유발 자장의 측정)

  • 이용호;권혁찬;김진목;박용기
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.421-428
    • /
    • 1997
  • Magnetic field sensors made from superconducting quantum interference device (SQUID) are the most sensitive low-frequency sensors available, enabling measurements of extremely weak magnetic fields from the brain. Neuromagnetic measurements allow superior spatial resolution, compared with the present electric measurements, and superior temporal resolution, compared with the fMRl and PET, providing useful informations for the functional diagnoses of the brain. We developed a 4-channel SQUID system for neuromagnetic applications. The main features of the system are its simple readout electronics and compact pickup coil structure. A magnetically shielded room has been constructed for the reduction of environmental magnetic noises. The developed SQUID system has noise level lower than the magnetic noise from the brain. Magnetic field signals of the spontaneous r-rhythm activity and auditory evoked magnetic fields have been measured.

  • PDF

Study about Prediction Model to Extremely Low Frequency Magnetic Fields for the Selected Primary Schoolchildren Nearby High Voltage Power Line (고압 송전선로 주변에 위치한 초등학교 학생들의 극저주파 자기장 노출량 예측 모델에 관한 연구)

  • Kim, Yoon-Shin;Hyun, Youn-Joo;Choi, Seong-Ho;Roh, Young-Man;Hong, Seung-Cheol
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.506-514
    • /
    • 2006
  • The objectives of this study were to evaluate personal exposure estimated using a time activity pattern and microenvironmental model. The study was carried out for 44 children attending a primary school nearby the lines (school A) and 125 children attending a school away from 154 kV power lines (school B). For children attending school A, the estimated personal level was a little weak correlated with the measured level($Pearson\;r\;=0.34{\sim}0.35$). For children attending school B, the correlation was very low ($Pearson\;r\;=\;0.09{\sim}0.16$) using the TW A Model II, otherwise, TWA Model II-I which considered the average residential MF level according to the distance from the power line and home explained $39{\sim}53%$ of the correlation in MF personal exposures. The estimated personal exposure level was very well represented by the measured exposure level using TWA Model II-2 which consisted on spot and 24 h stationary measurements at subject's home ($Pearson\;r\;=\;0.65{\sim}0.85$). In conclusion, personal magnetic field expsoure estimated using a TWA Model II-2 should be provided for a reasonable estimate of measured exposure in schoolchildren living near the power line.

Theoretical and Experimental Analysis of Extremely Low Frequency Magnetic Field in the Vicinity of the Transformer Station of Overhead Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali;Bizid, Youssef
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1655-1662
    • /
    • 2018
  • This paper studies the magnetic fields between the power lines which are finite length and other ones which are infinitely long around the first tower in the proximity of the power transformers. They will be used as a source of disturbance applied to the power line. The method applied in this study was gradual; develop the theoretical formulation of the magnetic fields of these lines which are finite length and other ones which are infinitely long, examine the effects of different couplings between the different neighboring lines and the distribution transformers on behavior of magnetic fields. The method also focused on the experimental results analyzing the magnetic fields which will be used as a source applied to the auditory implants EMC. The theoretical and experimental results were compared and discussed for three power lines (90kV, 150kV and 225kV) near the power station, and it proved the effect of these substations on the simulated and measured results of the magnetic field. The maximum intensities of magnetic fields measured at the height of 1m from the ground for the circuit of three lines close to each substation were significantly lower than the ICNIRP reference levels for occupational and non occupational exposures.