• Title/Summary/Keyword: Extreme-Pressure

Search Result 314, Processing Time 0.034 seconds

아날로그 PID 제어기를 이용한 2단 비례 압력 제어 밸브의 실현에 관한 연구 (A Study on PID Control Law's Realization for 2-Stage Proportional Pressure Control Valve with Analog Controller)

  • 윤소남;정황훈
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.58-61
    • /
    • 2012
  • The customers who used the hydroulic system desire the product that has more detailed specification quickly during the industrial technology is developed. Every researcher try to reduce the developed period and to satisfy the customers' desire. Lot's of simulation software and hardware already was used to be satisfied those purpose. But these kind of equipment need a lot of cost to set up and technical knowledge to drive that system. This paper concerns about analog PID controller that can be assembled with a few resistor, condenser and optional amplifier and doesn't need technical knowledge to drive. At the first, the plant was modeled mathematically to design the analog PID controller's circuit. After that, PID controller's parameter was selected by customers' desire. Finally, the analog PID controller's circuit was assembled from the control law. The circuit's availability was confirmed by step response test in the controlled system.

자동차 엔진의 ZnDTP 첨가제 농도에 따른 트라이볼로지 특성 (Tribological Characteristics with Concentration ZnDTP Additives in Automotive Engine)

  • 오성모
    • 한국산학기술학회논문지
    • /
    • 제8권4호
    • /
    • pp.697-702
    • /
    • 2007
  • 마찰 마모에 대한 트라이볼로지 특성은 표면 재질에 대하여 중대한 영향을 끼친다. 더욱이 자동차의 가혹한 운전조건하에서의 엔진오일의 경우 내스커핑성과 시져는 트라이볼로지 특성에 상당히 중요하다. 본 연구에서는 펠렉스 마찰 마모시험기를 이용 첨가제들을 자동차 엔진오일에 널리 쓰이는 윤활기유에 첨가하여 트라이볼로지 특성을 연구하였다. 연구결과 다음과 같은 결론을 얻었다. 엔진오일에 표면거칠기의 특성을 가진 인산염(Phosphate)을 첨가하면 낮은 온도에서 우수하고, ZnDTP와 Ca-phenate를 첨가했을 때 높은 하중에서 내마모성, 극압성이 월등히 뛰어나며, ZnDTP와 P를 첨가했을 때는 높은 온도에서도 안정적으로 온도특성 또한 우수하였다.

  • PDF

Computational method in database-assisted design for wind engineering with varying performance objectives

  • Merhi, Ali;Letchford, Chris W.
    • Wind and Structures
    • /
    • 제32권5호
    • /
    • pp.439-452
    • /
    • 2021
  • The concept of Performance objective assessment is extended to wind engineering. This approach applies using the Database-Assisted Design technique, relying on the aerodynamic database provided by the National Institute of Standards and Technology (NIST). A structural model of a low-rise building is analyzed to obtain influence coefficients for internal forces and displacements. Combining these coefficients with time histories of pressure coefficients on the envelope produces time histories of load effects on the structure, for example knee and ridge bending moments, and eave lateral drift. The peak values of such effects are represented by an extreme-value Type I Distribution, which allows the estimation of the gust wind speed leading to the mean hourly extreme loading that cause specific performance objective compromises. Firstly a fully correlated wind field over large tributary areas is assumed and then relaxed to utilize the denser pressure tap data available but with considerably more computational effort. The performance objectives are determined in accordance with the limit state load combinations given in the ASCE 7-16 provisions, particularly the Load and Resistance Factor Design (LRFD) method. The procedure is then repeated for several wind directions and different dominant opening scenarios to determine the cases that produce performance objective criteria. Comparisons with two approaches in ASCE 7 are made.

조선 중기 이후 서울의 장마철 강수 평균과 극한강수현상의 변화 (Changes in Means and Extreme Events of Changma-Period Precipitation Since mid-Joseon Dynasty in Seoul, Korea)

  • 최광용
    • 대한지리학회지
    • /
    • 제51권1호
    • /
    • pp.23-40
    • /
    • 2016
  • 본 연구에서는 조선시대 측우기(1777~1907년)와 현대적 기상장비(1908~2015년)로 측정한 강우량 자료를 종합 분석하여 서울의 장마철 강수량과 극한강수현상에 나타난 장기간 변화 양상을 밝히고자 하였다. 또한 이와 관련된 동아시아 영역의 종관 기후장에 나타난 변화 특징을 밝히고자 하였다. 약 239년 동안의 서울의 강수자료 시계열을 분석한 결과, 20세기 후반으로 올수록 장마철(6월 하순~9월 초순) 강수량이 증가하고, 경년변동성도 더 커짐을 알 수 있다. 특히 1990년대 초반부터는 장마철 중에서도 여름장마기(6월 하순~7월 중순)와 장마 휴지기(7월 하순~8월 초순)에 극한강수현상 중심의 강수량이 뚜렷하게 증가하면서 장마기의 구분이 모호해지고 있음을 알 수 있다. 이와 관련하여 변화가 뚜렷한 1990년 전후의 상층 종관기후장을 비교해 보면, 최근에는 북서태평양 주변의 해수면 온도가 상승하고 북태평양 아열대 고기압 강도가 강화되어 해양성 기단이 한반도 방향으로 더 확장하고, 유라시아 대륙 내부 몽골 지역을 중심으로 강한 고기압 편차핵이 형성되면서 고위도로부터 기류가 더 활발하게 유입되고 있음을 알 수 있다. 즉, 서로 다른 성질의 기류들이 강해지면서 이들 기류들이 만나는 북서태평양 연안 지역에 상승 기류 흐름이 활발해지면서 최근에는 서울의 장마철 강수평균 및 극한강수현상이 증가하였다고 할 수 있다.

  • PDF

Wind pressures on a large span canopy roof

  • Rizzo, Fabio;Sepe, Vincenzo;Ricciardelli, Francesco;Avossa, Alberto Maria
    • Wind and Structures
    • /
    • 제30권3호
    • /
    • pp.299-316
    • /
    • 2020
  • Based on wind tunnel tests, this paper investigates the aerodynamic behavior of a large span canopy roof with elliptical plan and hyperbolic paraboloid shape. The statistics of pressure coefficients and the peak factor distributions are calculated for the top and bottom faces of the roof, and the Gaussian or non-Gaussian characteristics of the pressure time-histories in different areas of the roof are discussed. The cross-correlation of pressures at different positions on the roof, and between the top and bottom faces is also investigated. Combination factors are also evaluated to take into account the extreme values of net loads, relevant to the structural design of canopies.

적층 벤더형 압전식 공압밸브의 내구 특성 (Endurance of Pneumatic Valve with a Multi-bender PZT Actuator)

  • 윤소남;박인섭
    • 동력기계공학회지
    • /
    • 제18권2호
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, pneumatic valve which consists of valve body, valve controller, nozzle and a multi-bender PZT actuator was suggested and fabricated. The fabricated pneumatic valve was experimented for performance evaluation. From the experimental results, we know that the flow rate of the suggested valve is 23 lpm at the pressure difference of 1bar and the maximum flow rate is 30 lpm at the pressure difference of 4 bar. The flow rates after endurance test of 9.8 million were 22.57 lpm and 28.62 lpm at the pressure difference of 1bar and 4bar, respectably. Finally, it was verified that the B10 life of the suggested pneumatic valve is over 50 million.

관재 하이드로 포밍에 의한 성형 공정의 실험적 연구 (Experimental Studies of the Forming Process for the Tubular Hydroforming Technology)

  • 김성태;임성언;이택근;김영석
    • 소성∙가공
    • /
    • 제9권1호
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, we developed the hydroforming simulator which can apply an axial compressive force and high internal pressure to bulge a tube. Experimental dtudies have been performed to investigate the effect of each parameters such as internal pressure and axial compression stroke required for the forming of circular components. Under the improper forming conditions there were two forming failures. One was the axial buckling due to excessive axial compressive load and the other was the circumferential necking fracture due to relatively high internal pressure. A safe forming zone without any failures exists between these two extreme zones. Also the condition of forming failure such as fracture is examined throughout the theoretical analysis. This paper covers a brief overview of the mechanism of hydroforming process as well as the design of die and tools.

  • PDF

평판디스플레이 세정 용 Quartz 메가소닉 시스템 (Quartz Megasonic System for Cleaning Flat Panel Display)

  • 김현세;이양래;임의수
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1107-1113
    • /
    • 2014
  • In this article, the megasonic cleaning system for cleaning micro/nano particles from flat panel display (FPD) surfaces was developed. A piezoelectric actuator and a waveguide were designed by finite element method (FEM) analysis. The calculated peak frequency value of the quartz waveguide was 1002 kHz, which agreed well with the measured value of 1003 kHz. The average acoustic pressure of the megasonic cleaning system was 43.1 kPa, which is three times greater than that of the conventional type of 13.9 kPa. Particle removal efficiency (PRE) tests were performed, and the cleaning efficiency of the developed system was proven to be 99%. The power consumption of the developed system was 64% lower than that of the commercial system. These results show that the developed megasonic cleaning system can be an effective solution in particle removing from FPD substrate with higher energy efficiency and lower chemical and ultra pure water (UPW) consumption.

벤더형 고응답 압전밸브의 주파수 특성에 관한 연구 (A Study on Frequency Characteristics of a Bender Type High-Speed Piezoelectric Pneumatic Valve)

  • 윤소남;함영복;박중호;이성수
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.14-18
    • /
    • 2012
  • Two kinds of piezoelectric actuator are applied to the valve for controlling the direction, the flow and the pressure of the fluid. One is a stack type piezoelectric actuator which has very fast response characteristics but very tiny displacement. The other is a bender type piezoelectric actuator which has also fast response characteristics but lower than the stack type one, and has longer displacement than the stack type one. So, the bender type piezoelectric actuator has advantage to apply to the valve for controlling a large amount of flow and fast on-off operating. In this study, the bender type piezoelectric pneumatic valve for color sorter is designed and fabricated. The new type high speed piezo valve with the both side supporting mechanism for high operating frequency and high reliability is discussed for separating the foreign body from the grains. Finally, the performance characteristics of a fabricated valve are analyzed and the frequency characteristics are also discussed for substituting the conventional type solenoid actuator.

Experimental assessment of the effect of frozen fringe thickness on frost heave

  • Jin, Hyun Woo;Lee, Jangguen;Ryu, Byun Hyun;Shin, Yunsup;Jang, Young-Eun
    • Geomechanics and Engineering
    • /
    • 제19권2호
    • /
    • pp.193-199
    • /
    • 2019
  • A frozen fringe plays a key role in frost heave development in soils. Previous studies have focused on the physical and mechanical properties of the frozen fringe, such as overall hydraulic conductivity, water content and pore pressure. It has been proposed that the thickness of the frozen fringe controls frost heave behavior, but this effect has not been thoroughly evaluated. This study used a temperature-controllable cell to investigate the impact of frozen fringe thickness on the characteristics of frost heave. A series of laboratory tests was performed with various temperature boundary conditions and specimen heights, revealing that: (1) the amount and rate of development of frost heave are dependent on the frozen fringe thickness; (2) the thicker the frozen fringe, the thinner the resulting ice lens; and (3) care must be taken when using the frost heave ratio to characterize frost heave and evaluate frost susceptibility because the frost heave ratio is not a normalized factor but a specimen height-dependent factor.