• Title/Summary/Keyword: Extra high voltage transmission

검색결과 35건 처리시간 0.022초

초고압 송전선로의 최적 격상전압 선정에 관한 연구-리비아국 사례 (A STUDY ON OPTIMAL UPGRADING VOLTAGE OF EHV GRID NETWORK-LYBIAN CASE)

  • 김봉희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1041-1043
    • /
    • 1997
  • When a new transmission line is planned to construct, the system voltage and the conductor size of the transmission line should be decided by both economical and technical point of view. This paper presents a methodology to determine the optimal voltage for upgrading the transmission system voltage of existing the extra high voltage grid network by meeting the requirements of the transmission cost minimization as well as technical constraints of thermal limit and stability limit in the transmission line. As a case study, calculated are optimal voltages versus distance and capacity of a practically applicable transmission line with 4 bundles 2 circuits. By this study 400kV was selected as the next higher voltage for the existing 220kV Libyan grid network.

  • PDF

초고압 XLPE 케이블 금속 차폐층 고찰 (A study or Metallic sheath for Extra-high voltage XLPE cable)

  • 최창수;이갑중;정무영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

초고압 송전선로에 의한 TV Ghost 장해 발생 특성 (Characteristics of TV Ghost Interference from Extra High Voltage Transmission Line)

  • 주문노;양광호;이동일;신구용
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.412-417
    • /
    • 2000
  • TV ghost interference can be described as passive interference by the conducting part of transmission lines. In order to survey this interference from large-sized overhead EHV (extra high voltage) transmission line, TV reception quality was measured in the vicinity of that before and after construction. Instrumentation system was composed of ghost analyzer, TV received field intensity meter, VHF/UHF antennas, TV monitor and so on. The system is installed inside the vehicle. TV field intensity and PDUR (Perceived Desired wave to Undersired wave Ratio) are measured to evaluate TV ghost by using the system and vehicle. As the results, the useful data, which can be used to evaluate the effect of TV ghost interference from transmission lines could be obtained. In this paper, it is shown that the range of TV ghost interference from transmission lines can vary according to the frequency of TV electromagnetic wave, an incidence angle to the line and the other conditiions. At present, we are making efforts to establish a PDUR guideline for transmission lines.

  • PDF

차기 초고압 송전선로의 도체방식 선정을 위한 환경설계 연구 (An Environmental Design Study for selecting Conductor Configurations of the next Extra High Voltage Transmission Line)

  • 박동욱;안희성;양광호;김정부;정상진;민석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.197-200
    • /
    • 1989
  • The corona interference of extra high voltage (EHV) transmission lines has to be considered as an important design factor for establishing an electrical environmental countermeasure at a basic line design stage. This paper describes the conductor selection procedure through both corona performance test result in corona cage and its evaluation by the design criterion. It is known that three conductor configurations including $6{\times}810mm^2$ (spacing: 40 cm) are the suitable conductor bundle for the environmental preservation around both 2-circuits and 1-circuit T/L.

  • PDF

충격전압발생기 트리거 시동장치 성능개선 (Improvement of triggering system of impulse voltage generator for Extra high-voltage)

  • 허종철;박승재;문인욱;박정후;오창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1704-1706
    • /
    • 2002
  • With increasement of use in electricity energy, quality of electric apparatus has been recognized as important factor in distribution and transmission line. Especially In laboratories, lightning and switching impulse performances of electric apparatus have been carrying out by impulse voltage generator (IVG), simulated into lightning and switching surge circuit. In this paper, we describe triggering system of impulse voltage generator(IVG) for extra high voltage, which has been newly designed.

  • PDF

대칭분 전압 단위 벡터를 이용한 송전선로 보호용 고장상 선택 알고리즘 (Fault Phase Selection Algorithm using Unit Vector of Sequence Voltages for Transmission Line Protection)

  • 이명수;이재규;김수남;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.460-466
    • /
    • 2002
  • A reliable fault phase selection algorithm plays a very important role in transmission line protection, Particularly in Extra High Voltage (EHV) networks. The conventional fault phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and select the fault phase in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can select the accurately fault phase using the sum of unit vectors which are calculated by positive-sequence voltage and negative-sequence voltage.

A Case Study of Resolving Conflict in Energy Infrastructure Siting by the Solar PV Project

  • Lee, Jonghwan;Shin, Dong-hwi;Han, Soohee;Roh, Jae Hyung
    • Current Photovoltaic Research
    • /
    • 제8권3호
    • /
    • pp.79-85
    • /
    • 2020
  • The growing demand for new energy infrastructure has often been encountered with the difficulties of siting in power plants and electric transmission lines. Siting such large-scale and complex facilities produces so many-sided issues that it is highly necessary to develop an approach to resolving the related problems and conflicts. This paper introduces how the stakeholders have handled the issues and resolved conflicts with residents opposed the construction of 765 kV transmission line. The solar photovoltaic power generation, called "Hee-Mang Sunlight Power project", is used for persuading residents to agree with constructing high-voltage transmission line and sharing benefits. It is considered how the project performance such as generation output and resident's profits is and proposed what the project should be revised and supplement. The project is shown that the intractable spiting in energy systems can be smartly resolved with cost-effective institutional solutions instead of relatively expensive technical ones.

초고압용 Composite hollow Insulator의 성능평가검토 (The Review of Performance Evaluation on Composite Hollow Insulator for Extra high-voltage)

  • 허종철;최익순;반석걸;최병화;박정후
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1808-1810
    • /
    • 2001
  • Because of its advantages such as more safe better electrical properties, lighter and easier to handle etc. than conventional ceramic materials, the development and application of composite insulator to the distribution and transmission system have been rapidly increased lately. In this paper, we reviewed performance evaluation on composite hollow insulator for extra high voltage based on IEC 61462 Technical Report 2, prospected to be published as international standards of Insulator for $SF_6$ GIS, Transformer, Arrestor etc, having been prepared by IEC technical committee 36 : insulator.

  • PDF

Wing Technique: A Novel Approach for the Detection of Stator Winding Inter-Turn Short Circuit and Open Circuit Faults in Three Phase Induction Motors

  • Ballal, Makarand Sudhakar;Ballal, Deepali Makarand;Suryawanshi, Hiralal M.;Mishra, Mahesh Kumar
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.208-214
    • /
    • 2012
  • This paper presents a novel approach based on the loci of instantaneous symmetrical components called "Wing Shape" which requires the measurement of three input stator currents and voltages to diagnose interturn insulation faults in three phase induction motors operating under different loading conditions. In this methodology, the effect of unbalanced supply conditions, constructional imbalances and measurement errors are also investigated. The sizes of the wings determine the loading on the motor and the travel of the wings while their areas determine the degree of severity of the faults. This approach is also applied to detect open circuit faults or single phasing conditions in induction motors. In order to validate this method, experimental results are presented for a 5 hp squirrel cage induction motor. The proposed technique helps improve the reliability, efficiency, and safety of the motor system and industrial plant. It also allows maintenance to be performed in a more efficient manner, since the course of action can be determined based on the type and severity of the fault.