• 제목/요약/키워드: Extra Capacity

검색결과 117건 처리시간 0.044초

A Retrospection on Foundation Design of Taipei 101

  • Chin, Chung-Tien;Chao, Hsiao-Chou;Chang, Der-Wen
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.145-156
    • /
    • 2009
  • Large diameter bored pile was selected as the foundation type for Taipei 101. The pile construction method and specific construction procedures were determined based on the results of trial installation and pile load tests. The baseline for foundation design was established using the friction versus depth characteristics of each ground layer obtained from the pile load tests. As the ground profile and depth to the top of rock formation varied significantly on this site, the pile length, bearing capacity and settlement for single pile were analyzed using the information interpreted from adjacent boreholes. The post grouting at pile tip was mandatory for pile construction. Nevertheless, it was treated as a measure reducing the influence of construction uncertainties and providing extra safety for the foundation system.

  • PDF

Nano-composites 절연파괴강도의 온도의존성 (Temperature dependance of Dielectric strength in Nano-composites)

  • 이강원;이혁진;김종환;신종열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.256-257
    • /
    • 2008
  • Recently, with the increase of demand of electricity, electric cable or electric transfer machine are rapidly developed and meet the demand with the extra high voltage and massive capacity, the dangers of electrical accident of insulator are increasing by the electric stress, insulation degradation and insulation breakdown in insulator. In this paper, it is investigated that the temperature dependance of dielectric strength in nano-composites. We obtained that breakdown voltage of 0.4 [wt%] specimens is higher than the other $SiO_2$ content.

  • PDF

Balancing Inter-Ring Loads on SONET Dual-Ring without Demand Splitting

  • Lee, Chae-Y.;Moon, Jung-H.
    • 산업공학
    • /
    • 제9권3호
    • /
    • pp.64-71
    • /
    • 1996
  • In the survivability and simplicity aspect, SONET Self-healing Ring(SHR) is one of the most important schemes for the high-speed telecommunication networks. Since the ring capacity requirement is defined by the largest STS-1 cross-section in the ring, load balancing is the key issue in the design of SONET SHR. Recently, most of the research on load balancing problem have been concentrated on the SONET single-ring case. However, in certain applications, multiple-ring configuration is necessary because of the geographical limitations or the need for extra bandwidth. In this paper, the load balancing problem for SONET dual-ring is considered by assuming symmetric inter-ring demands. We present a linear programming based formulation of the problem. Initial solution and improvement procedures are presented, which solves the routing and interconnection between the two rings for each demand. Computational experiments are performed on various size of networks with randomly generated demand sets. Results show that the proposed algorithm is excellent in both the solution quality and the computational time requirement. The average error bound of the solutions obtained is 0.26% of the optimum.

  • PDF

A Phase-shifter for Regulating Circulating Power Flow in a Parallel-feeding AC Traction Power System

  • Choi, Kyu-Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1137-1144
    • /
    • 2014
  • A parallel-feeding AC traction power system increases the power supply capacity and decreases voltage fluctuations, but the circulating power flow caused by the phase difference between the traction substations prevents the system from being widely used. A circuit analysis shows that the circulating power flow increases almost linearly as the phase difference increases, which adds extra load to the system and results in increased power dissipation and load unbalance. In this paper, we suggest a phase shifter for the parallel-feeding AC traction power system. The phase shifter regulates the phase difference and the circulating power flow by injecting quadrature voltage which can be obtained directly from the Scott-connection transformer in the traction substation. A case study involving the phase shifter applied to the traction power system of a Korean high-speed rail system shows that a three-level phase shifter can prevent circulating power flow while the phase difference between substations increases up to 12 degrees, mitigate the load unbalance, and reduce power dissipation.

이질적 다중서버 시스템에서 공정한 잔여용량 공유기법 (A Fair Extra Capacity Sharing Scheme for Heterogeneous Multi-Server Systems)

  • 이주현;박경호;김강희;민상렬
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2004년도 가을 학술발표논문집 Vol.31 No.2 (1)
    • /
    • pp.532-534
    • /
    • 2004
  • 단일서버 시스템에서 응용간 자원의 공정한 분배는 GPS(Generalized Processor Sharing)을 통친 실현될 수 있다. 그러나 다중서버시스템에서 GPS를 적용한다면, 각 서버 내에서의 공정성은 보장해 주지만, 시스템 관점에서의 공정성은 더 이상 보장되지 않는다. 본 논문에서는 멀티서버 시스템에서 시스템 관점에서의 공정성 보장을 위한 기법을 제시한다. 이 기법은 시스템에서 발생하는 각 서버의 잔여용량을 응용간 공정하게 분배하는 모델과 모델을 참조하여 실행하는 실제 스케줄링 알고리즘으로 구성된다 모델에서는 긴 시간동안 각 서버에서 발생하는 잔여용량의 사용을 관측하여, 향후 각 응용의 요청들에게 제공할 잔여용량 분배를 결정한다. 스케줄링 알고리즘은 모델에 의해 결정된 잔털용량 분배를 실제 각 응용들이 제대로 가져갈 수 있도록 제어한다. 실제 모델을 참조하여 공정 잔여용량 분배를 수행하는 스케줄링 알고리즘의 동작은 시뮬레이션을 통해 검증하였다.

  • PDF

Simplified Numerical Load-transfer Finite Element Modelling of Tunnelling Effects on Piles

  • Nip, Koon Lok (Stephen);Pelecanos, Loizos
    • 자연, 터널 그리고 지하공간
    • /
    • 제21권2호
    • /
    • pp.117-129
    • /
    • 2019
  • Tunnelling in urban environments is very common nowadays as large cities are expanding and transportation demands require the use of the underground space for creating extra capacity. Inevitably, any such new construction may have significant effects on existing nearby infrastructure and therefore relevant assessment of structural integrity and soil-structure interaction is required. Foundation piles can be rather sensitive to nearby tunnel construction and therefore their response needs to be evaluated carefully. Although detailed three-dimensional continuum finite element analysis can provide a wealth of information about this behaviour of piles, such analyses are generally very computationally demanding and may require a number of material and other model parameters to be properly calibrated. Therefore, relevant simplified approaches are used to provide a practical way for such an assessment. This paper presents a simple method where the pile is modelled with beam finite elements, pile-soil interaction is modelled with soil springs and tunnelling-induced displacements are introduced as an input boundary condition at the end of the soil springs. The performance of this approach is assessed through some examples of applications.

출하 된 레미콘의 용적실태에 관한 조사연구 (A Survey Study on the Shipment Volume of the Ready-Mixed Concrete)

  • 조만기;곽용진;김준호;손석헌;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.72-73
    • /
    • 2013
  • In this paper, types of ready mixed concrete in construction site supported by different company has been researched. The practicability of the commercial available ready mixed concrete has been tested, and the standard deviation has been modified from Vc=Vo+3б to Vc=Vo+1.73б. Unnecessary premium rate has been cut and economical efficiency of the ready mixed concrete has been improved.

  • PDF

생물막을 이용한 다공성 콘크리트의 수질정화 효율 개선에 대한 연구 (Research on improvement of water purification efficiency by porous concrete using bio-film)

  • 김태훈;;안태웅;최이송;오종민
    • 환경영향평가
    • /
    • 제20권6호
    • /
    • pp.815-821
    • /
    • 2011
  • This study aims to estimate the biological decomposition capacity of MPC(Microorganism Porous-Concrete). MPC has specific surface area formed by inside pores, and bio compound was added to those pores to reduce pollutants loading. To evaluate the water purification capacity of MPC, we carried out the comparative studies using different media types [GPC(General Porous-concrete), CPC(Compound porous-concrete), LPC(Lightweight aggregate porous-concrete)] under the condition of CFSTR, and different retention times (30, 60 and 120 min). We also estimated the purification capacity of MPC under different concentrations of pollutant loadings. The MPC showed higher efficiency in water purification function than other conventional porous concretes with efficient decrease rates of SS, BOD, COD, and nutrient concentrations. In the comparison experiment for different retention times, MPC showed the highest removal efficiency for all tested pollutants in the longest retention time(120 min). In the long period test, the removal efficiencies of MPC concrete were high until 100 days after the set up of the operation, but began to decrease. Outflow flux was invariable compared with inflow flux so that extra detention time for media fouling such as back washing is not needed. But the results suggested that appropriate management is necessary for long-term operation of MPC. As the final outcome, MPC using bio organisms is considered to be efficient for stream water purification when they used as substrates for artificial river structure.

농촌의 주곡 건조.저장.가공 작업체계 개선확립 (Improvement of System for Grain Drying, Storing , and Processing in Rural Area)

  • 서상용;이승규;김용환
    • Journal of Biosystems Engineering
    • /
    • 제3권1호
    • /
    • pp.33-46
    • /
    • 1978
  • To get the goal of self-supply of food grain, improvement of post-harvest grain operations in rural area is under consideration as an important task of agriculture in Korea. This is study is focused on elimination of losses and deteriorations of grain and reduction of labour requirements and funds for post-harvest grain operations. The purpose of this study are presentation of basic data referring to conventional post-harvest grain operations in rural area and suggestion of improving methods for the operations, and also finding out reasonable operating processes of the operations. The result of this study are follows; 1. Grain drying in-the-filed which is performed before threshing has major factors of grain loss during drying, and so should be restrained as possible. Combine harvesting system is recommended among other king of mechanized harvesting systems for restraining in-the-field drying and securing available labors for drying. 2. It is predicted that mechanical grain drying could be prevalent when combine harvesting is taken place. Recommended grain drier for pre-combine harvesting system and for combine harvesting system is batch-type drier and circulating -type drier, respectively. 3. As existing farm storages for grain have insufficient spaces and offer poor conditions for grain storing , it is greatly needed to build up new storage which store only grains. And it is concluded that storing grain in community common storages in desirable. 4. Power supplying system for milling machinery in local milling plants, that a large capacity prime mover supplies power to 4 to 6 kinds of milling machinery simultaeously, should be converted to a system of several small capacity prime movers supplying power to each machiner y for the purpose of reducing extra consumption of energy. 5. Governmental grain, of which Korean farms produced, should be milled and stored in the local milling plant successively for the purpose of reducing transportation fee and stroing facilities. 6. Furture post-havest grain operations-drying, storing and milling should be periormed successively in he community common plant. And average optimum processing capacity of the plant is estimated about 300 metric ton of grain every year.

  • PDF

MIMO 기법을 적용한 HDR-WPAN 시스템의 성능분석 (Performance Analysis of HDR-WPAN System with MIMO Techniques)

  • 한덕수;강철규;오창헌;조성준
    • 한국정보통신학회논문지
    • /
    • 제10권8호
    • /
    • pp.1502-1509
    • /
    • 2006
  • 본 논문에서는 최근 홈 네트워크 기술로 관심을 받고 있는 IEEE 802.15.3 HDR-WPAN (High Data Rate-Wireless Personal Area Network) 시스템의 성능 및 용량 향상 방안으로 MIMO 기법을 적용하고 컴퓨터 시뮬레이션을 통해 성능을 분석하였다. 특히, MIMO 기법 중 독립적인 각각의 부채널들에 서로 다른 데이터를 전송하여 전송률을 높이는 V-BLAST 기법을 적용하였다. HDR-WPAN 시스템의 TCM-64QAM 모드에서 V-BLAST 기법을 적용한 경우 최소 2개의 송수신 안테나를 사용하는 것으로도 대역폭 확장 없이 110Mbps 이상의 전송속도를 얻을 수 있었으며, 레일리 페이딩 채널에서 송신 안테나 2개, 수신 안테나 2개를 사용할 경우 약 $E_b/N_0=35dB$ (MMSE 알고리즘)에서 10-4의 BER 성능을 얻을 수 있었다. V-BLAST 기법을 적용한 HDR-WPAN 시스템은 수신단에서 복조 순서(ordering)를 결정하는 과정이 다소 복잡하지만 추가적인 대역폭 확장 없이 데이터 스트림을 다수의 안테나로 전송하여 전송 용량 및 성능을 높일 수 있었다.