• 제목/요약/키워드: Extinguishing Time

검색결과 107건 처리시간 0.027초

HCFC-123의 급성 독성간질환 발생 사례에 따른 노출기준 및 법 관리 필요성 권고 (Recommendation of an Occupational Exposure Limit and Legal Control Following an Acute Hepatotoxicity Incident from HCFC-123)

  • 이권섭;조지훈;최보경;이혜림;변상훈
    • 한국산업보건학회지
    • /
    • 제28권1호
    • /
    • pp.80-90
    • /
    • 2018
  • Objectives: This study was performed to propose a domestic occupational exposure limit(OEL) following a health hazard assessment, calculation of a non-carcinogenicity reference concentration worker($RfC_{worker}$) value, and examination of international agencies' exposure limits. It also recommends legal management within the Occupational Safety and Health Act for HCFC-123, which caused an acute hepatotoxicity incident. Methods: An acute hepatotoxicity incident due to the fire extinguishing agent HCFC-123 was investigated. Toxicological hazard and health hazard classifications were examined and a non-carcinogenicity $RfC_{worker}$ value was calculated for HCFC-123. An OEL and the necessity of legal management were recommended as well. Results and Conclusions: An OEL for HCFC-123 of 10 ppm($62.5mg/m^3$), which considered the $RfC_{worker}$ value, 5.56 ppm, produced in dose-response assessment and the exposure level of 19.1-20.9 ppm measured as an eight-hour TWA(time-weighted average) in the incident place, is recommended. HCFC-123 is urged to be included as a chemical requiring legal management in the Occupational Safety and Health Regulations. In addition, it is recommended that a peak exposure of ACGIH be adopted in the Notice of the Ministry of Employment and Labor.

DWT 및 고주파 노이즈 성분 분석을 이용한 PV 시스템 인버터 노이즈 구분 및 직렬 아크 검출 (Separation Inverter Noise and Detection of DC Series Arc in PV System Based on Discrete Wavelet Transform and High Frequency Noise Component Analysis)

  • 안재범;조현빈;이진한;조찬기;이기덕;이진;임승범;류홍제
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.271-276
    • /
    • 2021
  • Arc fault detector based on multilevel DWT with analysis of high-frequency noise components over 100 kHz is proposed in this study to improve the performance in detecting serial arcs and distinguishing them from inverter noise in PV systems. PV inverters generally operate at a frequency range of 20-50 kHz for switching operation and maximum power tracking control, and the effect of these frequency components on the signal for arc detection leads to negative arc detection. High-speed ADC and multilevel DWT are used in this study to analyze frequency components above 100 kHz. Such high frequency components are less influenced by inverter noise and utilized to detect as well as separate DC series arc from inverter noise. Arc detectors identify the input current of PV inverters using a Rogowski coil. The sensed signal is filtered, amplified, and used in 800kSPS ADC and DWT analysis and arc occurrence determination in DSP. An arc detection simulation facility in UL1699B was constructed and AFD tests the proposed detector were conducted to verify the performance of arc detection and performance of distinction of the negative arc. The satisfactory performance of the arc detector meets the standard of arc detection and extinguishing time of UL1699B with an arc detection time of approximately 0.11 seconds.

원칩형 PLC를 이용한 IT 기반 방재용 자동화시스템 개발에 관한 연구 (A Study on Development of Disaster Prevention Automation System on IT using One-chip Type PLC)

  • 곽동걸
    • 전력전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.97-104
    • /
    • 2011
  • 본 논문은 건물 내에서 발생되는 각종 화재 및 재해를 자동으로 신속히 감지한 후 현지에 설치된 방재설비들을 자동으로 동작시켜 화재 및 재해를 초기진압하고, 이들 재해상황들을 유무선 통신망을 통하여 실시간으로 원격지 상황실의 중앙관리시스템에서 모니터링되는 고속 고정밀의 IT 기반의 방재용 자동화시스템을 개발한다. 본 논문에서 제안하는 방재용 자동화시스템은 소형.경량 및 고감도 고정밀의 원칩형 PLC (one-chip type PLC)가 적용되어, 각종 재해 센서로부터 감지된 신호를 분석하고 재해발생시 조기진압을 위한 현장의 방재용 구동장치들을 작동시킨다. 또한 검출된 데이터들은 RS232c 및 블루투스에 의한 유무선 통신망을 통해 원격지 상황실에 데이터 전송 및 긴급 경보신호를 송출시키고, 모니터링 프로그램을 구동시킨다. 제안한 IT 기반의 방재용 자동화시스템은 화재와 각종 재해에 대한 예방과 신속한 조치로 인명과 재산의 손실을 최소화 하고자 한다.

소비자의 적합성 실증분석을 통한 가정용 소화기의 디자인 개선방안 (Methods to Improve the Design of Household Fire Extinguishers through an Empirical Analysis of Consumer Compatibility)

  • 이성우
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.58-66
    • /
    • 2020
  • 주택의 경우에는 소방법에서 제외 대상으로 되어 있어 화재가 발생하더라도 초기 소화에 골든타임을 놓쳐 대부분 인명사고로 이어지고 있다. 이처럼 주택에서 화재와 사망자가 많이 발생하고 있어 소방법을 개정하여 정부에서는 2017년부터 단독 주택에도 소화기를 의무적으로 비치하도록 하였다. 소방청 2018년 주택용 기초 소방시설 설치 실태조사 자료에 의하면 전체 비치율이 34.8%에 불과하다. 소화기는 화재 시에는 꼭 필요한 기구이지만 가정집에서는 기피 대상으로 생각하고 있다. 투박하고 빨간 색상으로 되어 있어 집안 분위기와 어울리지 않기 때문이다. 이제 소화기도 평상시에는 장식품과 팬시용품처럼 집안에 비치해 두다가 화재가 발생하면 화재를 진압할 수 있도록 심플하면서도 디자인이 다양한 소화기가 있어야 한다. 집안 어디에 두어도 장식물처럼 어울릴 수 있는 제품이라면 소비자들의 구매력을 향상시킬 수 있는 동기부여가 될 수 있다. 이제는 다양한 디자인으로 심플한 소화기가 개발되도록 관련업체의 디자인 개발이 실질적으로 이루어져 상품화를 기대한다.

SF6, g3 및 Dry Air 절연에서 PD 특성 비교 분석 (Comparative Analysis of PD Characteristics Under SF6, g3 and Dry Air Insulation)

  • 신한신;김남훈;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.490-494
    • /
    • 2020
  • Sulphur hexafluoride (SF6) is mostly used as a current-insulating medium in gas-insulated switchgears (GIS), owing to its excellent dielectric strength and arc-extinguishing performance. The global warming potential (GWP) of SF6, however, is 23,900 times that of CO2, and its life time in the atmosphere is 3,200 years. For these reasons, new eco-friendly gases to replace SF6 are required. In this study, the partial discharge (PD) characteristics of green gas for grid (g3) and dry air (N2/O2) were analyzed to compare with those of SF6. A PD electrode system was designed to simulate the protrusion defect in GISs and fabricated for experimentation. To compare the PD characteristics of each gas, the discharge inception voltage (DIV), discharge extinction voltage (DEV), discharge magnitude, discharge pulse number, and phase pattern were analyzed. Results from this study are expected to provide fundamental materials for the design of eco-friendly GISs.

열성 경련에 대한 최신 지견 (Recent Advance in Febrile Seizure)

  • 한윤정;장규태
    • 대한한방소아과학회지
    • /
    • 제21권3호
    • /
    • pp.189-203
    • /
    • 2007
  • Objectives The prognosis, recurrence rate and treatment of febrile seizure were studied through the research of recent western medicine and Chinese oriental medicine paper. Methods Recent western medicine paper of internal and external and chinese oriental medicine paper from 1999 to 2007 were investigated. Results and Conclusions The prognosis of febrile seizure was good in most cases, but children with febrile seizure who developed epilepsy range between 2 and 10%. The risk factors developed epilepsy including complex febrile seizure, focal and prolonged seizure, pre-existing neurodevelopmental abnormalities and recurrent febrile seizure. Recurrence rate of febrile seizure ranges between 30 and 50% was high. The risk factors can be predicted by their age at first febrile seizure happened, family medical history of febrile seizure and epilepsy, complex febrile seizure, and neurodevelopmental abnormalities. However, the most important factor of those is the age when they have first febrile seizure. Diazepam or Lorazepam was administrated for a child with prolonged seizure but only Diazepam was used for reducing recurrence of febrile seizurein febrile illness. However, there were some side effects such as lethargy, ataxia, and irritability. The study of chinese oriental medicine demonstrates that the acupuncture and venesection were used for seizure attack and reduced of recurrences and second attack. To reduce recurrence of febrile seizure, herbal medicine was also used for febrile illness or after seizure attack within a certain period of time, so reduce the recurrence, frequency of seizure and febrile illness. The most of herbs in prescription were used for removing heat and toxic meterials(淸熱解毒), extinguishing wind and to stopping the convulsion(熄風止痙)

  • PDF

고압 호스에서 굽힘의 각도가 압력 변화에 미치는 영향에 대한 수치해석적 연구 (Numerical Study on The Effect of Bending Angle on Pressure Change in High Pressure Hose)

  • 홍기배;김민석;유홍선
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.61-70
    • /
    • 2022
  • Fire damage time in high-rise buildings and wildland fire increasing every year. The use of high-pressure fire pumps is required to effectively extinguish fires. Reflecting the curvature effect of the fire hose occurring at the actual fire fighting site, this study provides a database of pressure drop, discharge velocity and maximum discharge height through C FD numerical analysis and it can provide using standards for fire extinguishing. Two Reynolds numbers of 200000 and 400000 were numerically analyzed at 0° -180° bending with water of 25℃ as a working fluid in hoses with a diameter of 65mm, a length of 15m, and a radius of curvature of 130mm. Realizable k-ε turbulence model was used and standard wall function was used. The pressure drop increases as the bending angle increases, and the maximum value at 90° and then decreases. The increasing rate is greater than the decrease. The velocity of the secondary flow also decreases after having the maximum value at 90°. The decreasing rate is greater than the increase. The turbulent kinetic energy increases to 120° and decreases with the maximum value. Pressure drop, velocity of the secondary flow, and turbulence kinetic energy are measured larger in the second bending region than in the first bending region.

음파 소화기를 이용한 안전 스토브 시스템 개발 (Development of Safe Stove System using Sound Wave Fire Extinguisher)

  • 서윤원;이석재;박형주;김기남;최용래;황형준;한승한;심동하
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.34-39
    • /
    • 2018
  • 본 논문에서는 최초로 음파 소화기를 이용한 자동 화재진압 기능을 가진 안전 스토브 아키텍처를 제안하고 개발하였다. 화재가 발생하면 화재 센서와 연동된 마이크로컨트롤러가 화재를 감지하고 음파 소화기를 구동하여 화재를 진압하는 구조를 가진다. 음파 소화기는 스피커와 콜리메이터로 구성되며, 오디오 증폭기를 포함하는 구동모듈에 의해 구동된다. 스토브를 둘러싸는 인클로저를 사용해 거리에 따른 음파의 확산을 막아 음파의 감쇠를 줄일 수 있었다. 이때, 사용된 음파의 주파수는 50 Hz이며, 음압은 소화기로 부터 0.5 m 거리에서 93 dBA로 측정되었다. 7 cc 및 14 cc의 가연성 액체에서 발생한 화염에 대해 진화에 소요되는 시간은 각각 최대 8 s와 15 s로, 각각 자연소화 시간의 24%와 42%에 해당한다. 제안된 안전 스토브는 기존 안전 스토브와 비교하여 무해하고 잔여물질이 남지 않기 때문에, 다양한 가전기기에 적용되어 원활한 초기 화재 진압 및 화재 확산 방지에 기여할 것으로 기대된다.

공동주택 건축물 내 화재방호시스템이 피난안전성에 미치는 영향에 대한 수치해석적 연구 (A Numerical Analysis Study on the Influence of the Fire Protection System on Evacuation Safety in Apartment Houses)

  • 김학경;최두찬;이두희;황현수;김희문
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.38-50
    • /
    • 2022
  • 연구목적: 본 연구는 방화관리자 및 건물 관계인이 피난안전성능 향상 계획 수립 시, 한정된 예산을 고려하여 피난안전성능 개선 항목 선정에 도움을 주는 수치해석 DB 구축 방향 수립이 목적이다. 연구방법: 직통계단형 아파트 1개동과 복도형 1개동을 선정하여 정량적 평가기법인 CFD기반 피난안전성평가를 수행하였다. 연구결과: 직통계단형 아파트는 방화구획 항목에서의 피난허용시간이 스프링클러설비 등 피난허용시간보다 약 130%이상 높게 나타났다. 결론: 방화관리자 및 건축물 관계인은 적법하게 유지관리하고 직통계단형 공동주택에서는 "주거세대 별도 방화구획"을 우선 적용하는 것이 피난안전성이 가장 개선되고, 층간 방화구획과 스프링클러설비를 상시 유지보수 및 강화하는 것이 효과적일 것으로 판단된다. 복도형 공동주택에서는 연기확산이 직통계단형 공동주택보다 제한적인 특성을 고려하여 소화설비의 유지보수가 우선되어야 할 것으로 사료된다.

일반재와 난연재 알루미늄복합패널의 수직화재 성상분석을 위한 실대형시험(ISO 13785-2)에 관한 연구 (A Study on the Large Experiments (ISO 13785-2) for Vertical Fire Behavior Analysis of Aluminum Composite Panels in General and Flame-retardant Material)

  • 최취경;민세홍
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.92-98
    • /
    • 2012
  • 본 연구에서는 건축 외장재로 많이 사용되고 있는 알루미늄복합패널의 일반재와 난연재에 대한 실제 화재에서의 화재성상을 분석하기 위하여 실대형 시험(ISO 13785-2)을 수행하였다. 시험결과, 일반재인 경우 최고 온도가 210초에 $1,021^{\circ}C$가 측정되었으며, 난연재는 약 1,200초에 $1,190^{\circ}C$가 측정되었다. 화재성상은 알루미늄복합패널 중 난연재의 경우 착화가 더디게 진행되었으며, 일반재의 알루미늄복합패널은 연소착화와 동시에 화재가 빠르게 확산되었다. 일반재와 난연재의 알루미늄복합패널은 연소착화하는데는 분명한 차이를 보였지만, 일단 착화된 이후에는 수직화염의 확산의 연소형태는 일반재나 난연재 모두 빠르게 수직확산되는 비슷한 양상을 보였다. 이에 본 연구결과, 알루미늄복합패널에 대한 화재위험성을 줄이기 위해서는 난연재 사용을 적극적으로 유도하도록 하며, 또한, 일단 착화 후에는 이를 진압할 외장재 전용 소화설비의 적용이 시급함을 알 수 있었다.