• Title/Summary/Keyword: External temperature

Search Result 1,509, Processing Time 0.03 seconds

Utilization as External Carbon Source of TVFAs Fermentation with Sludge (슬러지를 이용한 유기산 발효공정의 외부 탄소원으로 활용)

  • 김영규;김인배;김민호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.79-83
    • /
    • 2001
  • The sludge wastes fermentation process reactors were operated to produce the VFAs(volatile fatty acids) as supplemental carbon sources and to determine the optimum operating conditions. The experiment was carried out by varied mixture ration of 400:0 350:30 300:100 200:200 and operating temperature 2$0^{\circ}C$ 3$0^{\circ}C$ and 4$0^{\circ}C$ The results were as follows: Higher VFAs production rate observed at higher mixed ratio of primary sludge. When the mixed ratio of primary sludge and return sludge were 400:0 350:50 300:100 200:200 respectively. VFAs production are were 829.6mg/l 944.2 mg/l 597.9mg/ml an d441.6 mg/l , respectively. the yield of VFAs increased with temperature, but decreased with initial TSS concentration Because fermented sludge has relatively low nitrogen and phosphorus and relatively high VFAs it can be used as a substitute for external carbon in biological nutrient removal process.

  • PDF

Highly sensitive temperature sensor based on etched fiber with thermally expanded core (식각된 열확산 코어 광섬유를 이용한 고감도 온도 센서)

  • Kim, Kwang-Taek;Song, Hyun-Suk;Shin, Eun-Soo;Hong, Ki-Bum
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.263-268
    • /
    • 2006
  • We have demonstrated a highly sensitive temperature sensor using an etched single mode fiber with a thermally expanded core region. Large core size of thermally expanded core facilitates access to evanescent wave by the wet etching. The etched region was surrounded by a low dispersive external medium with high thermo-optic coefficient. Due to the large difference between the dispersion property of the fiber and that of the external medium, the device reveals a cut-off properties at spectral region. The cut-off wavelength was shifted by the variations of the environmental temperatures because of thermo-optic effect of the external medium. The sensitivity of the fabricated device was found to be $45nm/^{\circ}C$.

COERCIVE FIELD AND SPIN-GLASS BEHAVIOR OF AMORPHOUS Y-Fe ALLOYS

  • Fujita, A.;Fukamichi, K.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.762-766
    • /
    • 1995
  • The coercive field $H_{c}$ of amorphous Y-Fe alloys in the spin-glass state has been investigated. Foramorphous $Y_{10}Fe_{90}$ alloy, the thermal variations of $H_{c}$ in the maximum external field $H_{max}=300,\;600$ and 1 k Oe exhibit a maximum. Since spin-glass behavior is strongly affected by external magnetic fields, the maximum point moves to lower temperature with increasing $H_{max}$. The appearance of the maximum in $H_{c}$ has been discussed in terms of the change of the spin-glass state in the external magnetic field. When the value of $H_{max}$ is 55 kOe, the temperature dependence of $H_{c}$ has no maximum and shows an exponential decrease with increasing temperature. Similar trends have been observed over a wide concentration range. The concentration dependence of $H_{c}$ is associated with the magnetic phase diagram.

  • PDF

An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter (차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구)

  • Kim, Jin-Hee;Kim, Young-Tag;Lee, Soo-Yeol;Choi, Won-Ki
    • Land and Housing Review
    • /
    • v.12 no.1
    • /
    • pp.129-137
    • /
    • 2021
  • External shading devices are well known solar control devices that can help reduce the cooling load of commercial buildings. For this study, experiments were conducted to examine the feasibility of shading devices in reducing both the cooling and heating loads. The influence of sky radiant cooling during winter was verified for the external shading device, internal roller blind, and window. Results can be summarized as follows. The temperature difference between the inner and outer surfaces of the window with the external shading device was 11.8℃ compared to 14.6℃ for one without the external shading device. This 2.8℃ difference was due to heat exchange by sky radiation when the surface temperature of the shading device was lower than the ambient outdoor air temperature. The roller blind resulted in a lower temperature of 0.8℃ compared to the average temperature of the window's air cavity. This was due to heat exchange by sky radiation of the roller blind surfaces. Without shading devices, the outside surface temperature of the window is about 3℃ higher. The study also found that when external shading devices were installed on both the southwest and southeast sides, the outside surface temperature of the windows were lower on the southwest side than the southeast side.

Development of a Ventilation Model for Mushroom House Using Adiabatic Panel

  • Kim Kee Sung;Han Jin Hee;Kim Moon Ki;Nam Sang Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.7
    • /
    • pp.35-44
    • /
    • 2004
  • In this study, a ventilation model was developed to determine a ventilation rate for the balance of heat, moisture and $CO_{2}$ in a mushroom house. Internal and external temperature, relative humidity and $CO_{2}$ concentration were measured and used to validate the ventilation model. The effects of various environmental factors on physiological responses of mushroom were also investigated. The verified model was simulated under the observed ventilation rates with a difference of$ 0.001{\~}0.065\;m^{3}{\cdot}S^{-1}$ (relative error of $0.3{\~}18.9\%$) when external temperature varied 22.5 to $24.8^{circ}C$ and average ventilation rates was $0.35m^{3}{\cdot}S^{-1}$. The optimal conditions for mushroom growth (internal temperature $22 ^{circ}C$, relative humidity $80\%$, $CO_{2}$ concentration 1,000 ppm) were used for the model application with external temperature, relative humidity and $CO_{2}$ concentration of $27.5{\~}33.5^{circ}C$, $60\%$, and 355 ppm, respectively. Thermal balance was a important factor for an optimum ventilation up to the external temperature of $32^{circ}C$, while $CO_{2}$ concentration balance was more important over $32^{circ}C$. This suggests that humidification for moisture balance is required to maintain temperature and $CO_{2}$ concentration at an optimal level by ventilation in a mushroom house.

Stability analysis of an insulationless HTS pancake coil under the magnitude of external magnetic field

  • Jung, Sung-Jun;Kim, Gyeong-Hun;Kim, Kwangmin;Park, Minwon;Yu, In-Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.4
    • /
    • pp.41-45
    • /
    • 2012
  • An HTS (high temperature superconducting) coil without insulation has been investigated since a metallic insulation was suggested in the mid-1980s. The advantage of an insulationless HTS pancake coil is that it is more stable than an insulated HTS pancake coil. This paper focuses on the various characteristics of the insulationless HTS pancake coil related with stability, especially under the external magnetic field. Because HTS pancake coil may be influenced by the external magnetic field in a real operational environment of electrical devices. First, charge-discharge test was performed for the characteristics evaluation of the insulationless HTS pancake coil as compared with insulated HTS pancake coil in liquid nitrogen at 77 K. Based on the experiment results, characteristics evaluation of the insulationless HTS pancake coil was implemented under the external magnetic field. In order to carry out the experiment, we have fabricated a cylindrical solenoid coil to apply the magnetic field. The various characteristics of the insulationless HTS pancake coil were evaluated for charge-discharge and over-current conditions. This paper proves that the insulationless HTS pancake coil is more stable than the insulated HTS pancake under the external magnetic field.

A Study on the Application of the Lean Boosting in a Hydrogen-fueled Engine with the SI and the External Mixture (흡기관 분사식 수소 SI기관의 희박과급 적용에 관한 연구)

  • Lee, Kwangju;Lee, Jonggoo;Lee, Jongtai
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.2
    • /
    • pp.136-141
    • /
    • 2013
  • In order to achieve simultaneously the ultra-low NOx, the high power and the high efficiency in a hydrogen-fueled engine with SI and the external mixture, the effects of low temperature combustion, performance and exhaust are compared and analyzed by the application of the lean boosting. As the results, the decrease rate of the high temperature in the hydrogen is less decreased than the other fuels by high constant-volume specific heat. However, when the conditions of 1.7bar and ${\Phi}=0.33$ are reached by the lean boosting, the maximum gas temperature of hydrogen is decreased under the temperature of NOx formation and it is possible to stabilize combustion below 2% of COVimep. Also, at that condition, it is feasible to achieve simultaneously NOx-free and the power of gasoline level. Therefore, it is found that the lean boosting is useful in the hydrogen-fueled engine.

NUMERICAL ANALYSIS FOR UNSTEADY THERMAL STRATIFIED FLOW WITH HEAT TRACING IN A HORIZONTAL CIRCULAR CYLINDER

  • Jeong, Ill-Seok;Song, Woo-Young;Park, Man-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.304-309
    • /
    • 1997
  • A method to mitigate the thermal stratification flow of a horizontal pipe line is proposed by heating external bottom of the pipe with electrical heat tracing. Unsteady two dimensional model has been used to numerically investigate an effect of the external Denting to the thermally stratified flow. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature distribution, streamline profile and Nusselt numbers of fluids and pipe walls with time are analyzed in case of externally heating condition. no numerical result of this study shows that the maximum dimensionless temperature difference between the hot and the cold sections of pipe inner wall is 0.424 at dimensionless time 1,500 ann the thermal stratification phenomena is disappeared at about dimensionless time 9,000. This result means that external heat tracing can mitigate the thermal stratification phenomena by lessening $\Delta$ $T_{ma}$ about 0.1 and shortening the dimensionless time about 132 in comparison with no external heat tracing.rnal heat tracing.

  • PDF

The Relationship between Thermal Preference and Hibernation Strategies in Endangered Plecotus ognevi (멸종위기 야생생물 II급 토끼박쥐 Plecotus ognevi의 온도선호도와 동면 전략)

  • Kim, Sun-Sook;Choi, Yu-Seong;Kim, Lyoun
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.4
    • /
    • pp.345-353
    • /
    • 2018
  • Hibernation is regarded as a physiological and behavioral adaptation that permits the survival of animals such as bats during seasonal periods of energy shortage. This study investigated the hibernation period of Plecotus ognevi in the temperate climate zone and the relationship between the thermal preference and hibernating process of bats. We hypothesized that the hibernation period of bats is closely related to the external temperature and temperature preference of bat species in the temperate region. To verify this hypothesis, we surveyed the distribution of the P. ognevi population in South Korea, and the temperature preference and the characteristics of hibernacula of P. ognevi. We predict that hibernation in the bat will begin when the external temperature drops below the thermal preference of the species and will leave from hibernation when the external temperature is higher than the thermal preference. P. ognevi hibernated in roosts maintained in low temperature ambient conditions with $-3.5{\sim}7.5^{\circ}C$). The body temperatures (averaged $3.01{\pm}1.30^{\circ}C$, ranged $0.1{\sim}7.8^{\circ}C$) of hibernating bats were closely related to the rock surface temperatures rather than the ambient temperatures. The bats began to hibernate in late November and final arousals occurred in mid-March, so that the total length of the hibernation was 115~120 days. The period of hibernation was strongly influenced by fluctuations in the external mean temperature. This study suggests that the onset and termination of P. ognevi hibernation is due to the interaction between the temperature of the hibernacula and that of the external environment and is based on the thermal preference of the bats. The study also suggests that the hibernation strategy such as thermal preference and hibernation periods of this species affect to distribution as bat species adapting to a severely climate.

A Counterplan of temperature crack control by a heat of hydration of Subway concrete box structure concerned External Temperature (대기온도를 고려한 지하철 콘크리트 Box 구조물의 수화열에 의한 온도균열제어 대책)

  • Roh, Hyun-Sup;Kim, Eun-Kyum;Yang, Sin-Chu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.581-584
    • /
    • 2007
  • The subway concrete box structure can`t establish expansion joint because of animal power delivery of the subway rail. In this case, As increase of structure volume, it is subjected to cause temperature crack. The temperature crack due to the heat of hydration classified a nonstructural crack. but it has a bad effect on durability of concrete structures. especially, in case of a subway concrete box structure, when a water-proof facilities is beaked on an outer-wall, the water leakage occurs through a penetration crack generated from a wall of the concrete structure too. This paper, for the subway concrete box structure, examined a condition of temperature crack occurrence by a heat of hydration concerned external temperature from analysing by a three dimensional finite element method.

  • PDF