Browse > Article
http://dx.doi.org/10.5389/KSAE.2004.46.7.035

Development of a Ventilation Model for Mushroom House Using Adiabatic Panel  

Kim Kee Sung (Dept. of Agricultural and Biosystems Engineering, University of Arizona)
Han Jin Hee (Dept. of Agricultural and Biosystems Engineering, University of Arizona)
Kim Moon Ki (Department of Agricultural Engineering, Seoul National University)
Nam Sang Woon (Department of Bioresource Engineering, Chungnam National University)
Publication Information
Journal of The Korean Society of Agricultural Engineers / v.46, no.7, 2004 , pp. 35-44 More about this Journal
Abstract
In this study, a ventilation model was developed to determine a ventilation rate for the balance of heat, moisture and $CO_{2}$ in a mushroom house. Internal and external temperature, relative humidity and $CO_{2}$ concentration were measured and used to validate the ventilation model. The effects of various environmental factors on physiological responses of mushroom were also investigated. The verified model was simulated under the observed ventilation rates with a difference of$ 0.001{\~}0.065\;m^{3}{\cdot}S^{-1}$ (relative error of $0.3{\~}18.9\%$) when external temperature varied 22.5 to $24.8^{circ}C$ and average ventilation rates was $0.35m^{3}{\cdot}S^{-1}$. The optimal conditions for mushroom growth (internal temperature $22 ^{circ}C$, relative humidity $80\%$, $CO_{2}$ concentration 1,000 ppm) were used for the model application with external temperature, relative humidity and $CO_{2}$ concentration of $27.5{\~}33.5^{circ}C$, $60\%$, and 355 ppm, respectively. Thermal balance was a important factor for an optimum ventilation up to the external temperature of $32^{circ}C$, while $CO_{2}$ concentration balance was more important over $32^{circ}C$. This suggests that humidification for moisture balance is required to maintain temperature and $CO_{2}$ concentration at an optimal level by ventilation in a mushroom house.
Keywords
Mushroom house; Heat and mass balance; Ventilation model;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Baptista. F. J.. Bailey. B. J.. Randall. J. M., and Meneses, J. F., 1999. Greenhouse ventilation rate: theory and measurement with tracer gas techniques. J. Agric. Engng. Res. 72 : 363-374   DOI   ScienceOn
2 Esmav, M. L. and Dixon, J. E. 1986. Environmental control for agricultural buildings. The AVI Publishing Company
3 Hellickson. M. A. and J. N. Walker. 1983. Ventilation of Agricultural Structures. American Society of Agricultural Engineers
4 Loeffen, H., 1994, Carbon dioxide production rate as a measure of growth of mushroom crops, Mushroom Journal, 517 : 28-29
5 Loeffen, H.. 1995. The influence of compost temperature on the activity of mushroom substrate. Mushroom Journal. 548 : 28-29
6 Son. J. E.. 2000, Thermal and ventilation characteristics of single span oak mushroom production facility as affected by area of roof opening and shading rates, Journal of Bio-environrnent Control. 9(2) : 120-126
7 Thepa, S.. Kirtikara, K., Hirunlabh, J. and khedari, J., 1999. improving indoor conditions of a Thai-rstyle mushroom house by means of an evaporative cooler and continuous ventilation, Renewable Energy 17 : 359-369
8 Choi, H. L, Kim, W. J. Kim, H. T. 1991, Development of new conceptual ventilation graphs for mechanically ventilated livestock building, The Korean society of agricultural engineers. 33 (3) : 91-100
9 Chao D. Y, 1989. New mushroom cropping technique, Sangrocksa
10 Albright L. D.. 1990. Environment Control for animal and plants. ASAE Textbook. Michigan. USA
11 Choi. W. S., K. S. Park and J. E. Son. 2000. Environmental analysis of oak mushroom production facilities using different shading methods. Proceeding of Bio-Environment Control 9(1): 65-68
12 Nam, S. W, 2000. Application of heat balance model to design of ventilating and cooling greenhouses, Journal of Bio-Environment Control, 9(4) : 201-206
13 Trevor V. Suslow and Marita Cantwell. 2002, Recommendations for maintaining postharvest quality. Postharvest Technology Research & Inforamtion Center. UC Davis
14 Campen. J. B., Bot. G.P.A. 2003. Determination of greenhouse-specific aspects of ventilation using three-dimensional computational fluid dynamics. Biosvstems Engineering 84 (1) : 69-77