• Title/Summary/Keyword: External source

Search Result 771, Processing Time 0.035 seconds

Analysis of Characteristic of Wound Therapy Apparatus using ${\mu}$-Controller (마이크로컨트롤러를 이용한 창상 치유기의 특성 평가)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.497-497
    • /
    • 2007
  • We developed the light medical therapy apparatus for external injury cure using a ${\mu}$-controller. This equipment was fabricated by using a high brightness LEDs and a ATmega 128, and designed to enable us to control irradiation timer, intensity and reservation. Especially, to control the light irradiation frequency, and to control the change of output value, TLC5941 was used. Control stage is divided into 4 step by program. Consequently, the current value could be controlled by the change of level in Continue Wave(CW) and the output of a high brightness LEDs could be controlled, stage by stage. In this paper, the designed device was used to find out how a high brightness LEDs light source affects the skin wound of a small animal. In result, compared with none light irradiation animal, the lower incidence of inflammation and faster recovery was shown in light irradiation animal.

  • PDF

A Study for Absolutely Distance Measurement System of Wavelength Variable Type by Using Pinciple of the Michelson Interometer (마이켈슨 간섭계의 원리를 이용한 파장변화형 절대 거리측정기의 기초 연구)

  • 김철한;신영록;양윤석;김한근;사공건
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.651-653
    • /
    • 2000
  • In this study, a distance-measurement system was proposed by using principle of the Michelson Interferometer and a fundamental research was carried out. In case of the rnichelson interferometer, relativity distance was measured by relativity-difference of two course of light. But wavelength of light source were changed in this system in order to use interference phenomenon of michelson interferometer in measuring absolutely distance. Wavelength of input signal were changed periodically and were interfered electrically. So absolute distance can be calculated by using $\Delta\lambda$ and measuring $\eta\Delta$ in electric interference. Nose by a external factor was small in this system because a absolutely distance was measured by phase difference. And a dispersion of noise was small in pulse-echo response because a error was occurred in range of phase difference of signal. Also very wide range can be measured by only single system because informations of distance were acquisited in wavelength level.

  • PDF

A development of the Hybrid Sensor for the detection of the High Frequency Partial Discharge(HFPD) (고주파 부분방전(HFPD)측정용 하이브리드 센서 개발에 관한 연구)

  • Kim, J.H.;Koo, J.Y.;Kim, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.173-175
    • /
    • 2002
  • In general, CT and Shunt have been traditionally used as a sensor for detecting the partial discharges in order to diagnose the present insulation state of the electric power apparatus. The former is very convenient for the practical application since it is not only non-contact method but its frequency bandwidth and resonance frequency could be designed for its specific application. However, it has been proved to have poor linearity and low sensitivity. For the latter, even though it is an ideal sensor, noise from the power source and the ground could flow into the system. Furthermore, the surge current could be easily come into the measuring systems giving rise to a severe breakdown. In this respect, a hybrid sensor has been designed and fabricated in order to overcome the shortcoming of these two types of sensors. For this purpose, the experimental comparison with commercialized products has been also carried out. In this concept of the hybrid sensor, two different impedances could provide the passage of the signals. In this way, the discrimination of the noise could be accomplished very effectively with high ratio of signal over noise(S/N) under the little influence from the external noises and the breakdown.

  • PDF

Design and Application of a Ground Risk Voltage Measurement System (대지 위험전압 측정기의 설계 및 적용)

  • Jang, Un-Yong;Cha, Hyeon-Kyu;Cha, Sang-Wook;Park, Dae-Won;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.250-255
    • /
    • 2011
  • This paper dealt with the design, fabrication and application of a risk voltage measurement system (RVMS) which analyzes the step and touch voltages in electrical grounding systems. The RVMS supply 300 V and 1.4 A in ranges from 40 Hz to 1 kHz as the test power source. A DAQ module having resolution of 400 kS/s and 16 bit is equipped with 7 inputs for measuring voltage and current. Also, a noise elimination algorithm of digital filter was applied to reduce the measurement error caused by external noises as a commercial frequency current. The performance of the RVMS was evaluated by measurement of the step and touch voltage according to the IEEE standard 80 and 81 in a grounding system with a 10 m counterpoise. The result showed that the RVMS analyzes the risk voltage with the error below 5%.

Red and Blue Photons Can Enhance the Production of Astaxanthin from Haematococcus pluviatis

  • Kim, Z-Hun;Lee, Ho-Sang;Lee, Choul-Gyun
    • ALGAE
    • /
    • v.24 no.2
    • /
    • pp.121-127
    • /
    • 2009
  • The unicellular green alga, Haematococcus pluvialis, accumulates the highest level of astaxanthin among knownastaxanthi.n-producing organisms. Light is the most important factor to induce astaxanthin by H. pluvialis. BIue andred LEDs, whose ${\lambda}_{max}$'s are 470 and 665 nm, respectively, were used for internally illuminated light sources.Fluorescent lamps were also used for both internal and external illumination sources. The astaxanthin levels in thesevarious lighting systems were analyzed and compared each other. The cultures under internally illuminated LEDsaccumulaled 20% more astaxanthin than those under fluorescent lamp. Furthermore, LEDs generated much lessheat than the fluorescent lamps, which gives one more reason for the LEDs being a suitable internal Light source forastaxanthin induction. The results reported here would lead novel designs of photobioreactors with improvementsof illumination methods for high level of astaxanthm production. The maximum astaxanthin concentrations as wellas the astaxanthin yield per supplied photon were increased by at least 20% when blue or red LEDs were supplied.

Combustion Characteristics of Spruce Wood by Pressure Impregnation with Waterglass and Carbon Dioxide (물유리와 이산화탄소로 가압함침한 가문비 나무의 연소특성)

  • Park, Hyung-Ju;Lee, Se-Myeoung
    • Fire Science and Engineering
    • /
    • v.26 no.4
    • /
    • pp.18-23
    • /
    • 2012
  • After produce the extracted wood to silicic acid gel, sodium carbonate and silicon dioxide with application of the making method for carbon dioxide, ignition time, ignition temperature, mass loss rate and critical heat flux are measured according to external radiation source (20, 25, 35 and 50 $kW/m^2$). From the results, pressure impregnation wood to use with water glass and carbon dioxide has fire retardant performance at heat flux (less than 20 $kW/m^2$) of Pre-Flashover fires. If we find out the excellent maxing ratio through continuously study, it might be decided to be able to be utilized as fire-retardant wood.

A Study of Hydraulic Actuator Based On Electro Servo Valve For A Walking Robot (보행 로봇을 위한 서보밸브 구동 유압 액추에이터의 특성 분석)

  • Cho, Jung San
    • Journal of Drive and Control
    • /
    • v.13 no.2
    • /
    • pp.26-33
    • /
    • 2016
  • This paper describes of a mathematical and real experimental analysis for a walking robot which uses servo valve driven hydraulic actuator. Recently, many researchers are developing a walking robot based on hydraulic systems for the difficult and dangerous missions such as walking in the rough terrain and carrying a heavy load. In order to design and control a walking robot, the characteristics of the hydraulic actuators in the joint through the view point of walking such as controllability and backdrivability must be analyzed. A general mathematical model was used for analysis and proceeds to position and pressure changes characteristic of the input and backdrivability experiment. The result shows the actuator is a velocity source, had a high impedance, the output stiffness is high in contact with the rigid external force. So stand above the controller and instruments that complement the design characteristics can be seen the need to apply a hydraulic actuator in walking robot.

Frequency Dependent Damping for a Nonlinear Vehicle Active Suspension System (비선형 차량능동현가시스템의 주파수 감응감쇠 특성연구)

  • Kim, J.Y.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.45-54
    • /
    • 2011
  • A vehicle suspension system performs two functions, the ride quality and the stability, which conflict with each other. Among the various suspension systems, an active suspension system has an external energy source, from which energy is always supplied to the system for continuous control of vehicle motion. In the process of the linearization for the nonlinear active suspension system, the frequency dependent damping method is used for the exact modelling to the real model. The pressure control valve which is controlled by proportional solenoid is the most important component in the active suspension system. The pressure control valve has the dynamic characteristics with 1st order delay. Therefore, It's necessary to adopt the lead compensator to compensate the dynamics of the pressure control valve. The sampling time is also important factor for the control performances. The sampling time value is proposed to satisfy the system performances. After the modelling and simulation for the pressure control valve and vehicle dynamic, the performances of the vehicle ride quality and the stability are enhanced.

Prototyping of Basic Components in Catalog Services of Geo-spatial Information Linked to PostgreSQL (지형공간정보 카탈로그 서비스 기본요소의 PostgreSQL 연동 시험모델 구현)

  • Han, Sun-Mook;Lee, Ki-Won
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.133-142
    • /
    • 2010
  • As diverse web-based geos-spatial services are developed, the values of technologies and standards related to this trend are also emphasized. In this study, a prototype supporting mandatory components in OGC standard catalog service is designed and implemented, linked to PostgreSQL, open source DBMS. As the main features, XML metadata server was built with the helps of XML query functions in PostgreSQL. Given target applications with geo-spatial data sources and contents, this model can be applied, and it can be used for extension in other external web-based service systems or applications, because it supports international standard specifications.

A Study on Design of EMC Filter in the High Powered Breaker (대전력용 차단기 내의 EMC 필터 설계에 관한 연구)

  • Kim, Eun-Mi;Jeon, Mi-Hwa;Kim, Dong Il
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.139-142
    • /
    • 2009
  • Rapid developments in the field of electronic communication have given people's daily life much more convenience and abundance. However, making precise electrical and electronic devices and control systems lighter, smaller, and faster have caused lots of problems such as interference of external electric source, malfunction brought by electric fast transient(EFT), and influence on human body. In this research, the EMC filter in the high powered breaker was designed and fabricated as a countermeasure. The filter attenuated noise more than 30 ~ 75 dB in the range of 10 MHz ~ 1.5 GHz. And, when the EFT of 4 kV in the level 4 of IEC 61000-4-4 was induced, it was soon suppressed to 600 V.

  • PDF