• Title/Summary/Keyword: External resistor

Search Result 49, Processing Time 0.023 seconds

Optimal Starting Torque Control of Wound Rotor Induction Motor by Microprocessor (개용분 PFN-PMW의 유전특성에 관한 연구)

  • Park, Min-Ho;Jung, So-Woong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.316-324
    • /
    • 1984
  • In the wound rotor induction motor, the external resistor is usually added to the rotor circuit in order to limit the starting current. In this scheme, whilst the starting current is limited, the available torque is remarkably reduced. In this paper, to improve the starting characteristics the stator current can be maintained constant by adjusting the external resistor. To change the external resistor, teh chopper and the resistor is connected in parallel, and the chopper duty cycle is adjusted by microprocessor. The duty cycle is calculated according to the actual speed of motor by microprocessor look-up table map. In this suggested scheme, the starting characteristics are remarkably improved without over-current. The starting time of this system is reduced by 20-48 Percent compared with fixed extemal resistance system in the same load.

  • PDF

Temperature sensor without reference resistor by indium tin oxide and molybdenum (인듐틴옥사이드와 몰리브데늄을 이용한 외부 기준 저항이 필요 없는 온도센서)

  • Jeon, Ho-Sik;Bae, Byung-Seong
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.483-489
    • /
    • 2010
  • Display quality depends on panel temperatures. To compensate it, temperature sensor was integrated on the panel. The conventional temperature sensor integrated on the panel needs external reference resistor. Since the resistance of external resistor can vary according to the variation of the environment temperature, the conventional temperature sensor can make error in temperature sensing. The environmental temperatures can change by the back light unit, driving circuits or chips. In this paper, we proposed a integrated temperature sensor on display panel which does not need external reference resister. Instead of external reference resistor, we used two materials which have different temperature coefficient in resistivity. They are connected serially and the output voltage was measured at the point of connection with the applied voltage to both ends. The proposed sensor was fabricated with indium tin oxide(ITO), and Mo metal electrode temperature sensor which were connected serially. We verified the temperature senor by the measurements of sensitivity, lineality, hysteresis, repeatability, stability, and accuracy.

Unequal Gysel Power Divider Using External One Resistor (한 개의 저항을 사용한 비균등 Gysel 전력 분배기)

  • Yoon, Young-Chul;Sim, Seok-Hyun;Kim, Young
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.3
    • /
    • pp.224-229
    • /
    • 2015
  • In this paper, we derived the design equation and implemented the unequal Gysel power divider that is one external resistors using the ABCD parameters analysis. Conventional unequal Gysel divider is difficult to obtain the characteristics of isolation and return loss at between output ports because it can't select a theoretical value of external resistor. To solve those problems, we design the new unequal Gysel power divider with transmission lines and one external resistor that has the characteristics of conventional unequal Gysel divider. To validate this design method, we simulated and measured an 4: 1 unequal Gysel power divider at the center frequency 1 GHz. The measured performances agreed well with the simulation results.

Passive Damping Enhancement of Composite Beam Using Piezo Ceramic Connected to External Electrical Networks (외부 회로가 연결된 압전 세라믹을 이용한 복합재 보의 수동 감쇠 개선)

  • Yang, Seung-Man;Kim, Do-Hyung;Han, Jae-Hung;Lee, In
    • Composites Research
    • /
    • v.12 no.2
    • /
    • pp.1-9
    • /
    • 1999
  • The piezoelectric material connected to external electric networks possesses frequency dependent stiffness and loss factor which are also affected by the shunting circuit. The external electric networks are generally specialized for two shunting circuits: one is the case of a resistor alone and the other is the combination of a resistor and an inductor. For resistive shunting, the material properties exhibit frequency dependency similar to viscoelastic materials, but are much stiffer and more independent of temperature. Shunting with a resistor and inductor introduces an electrical resonance, which can change the characteristics of structural resonance optimally in a manner analogous to a PMD (proof mass damper). Passive damping enhancement of composite beam using piezoelectric material connected to external electrical networks is achieved and presented in this paper.

  • PDF

Pd Shunt Resistor for Josephson Junction : Fabrication and Dynamic Simulation (Pd Shunt저항의 제작 및 동력학특성 조사)

  • 김규태;남두우;이규원;유광민
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.143-145
    • /
    • 2003
  • External shunt resistor is used in Nb/AlOx/Nb Josephson junction which is basic component of RSFQ circuit. This is to increase damping and to make the so called 'self-reset' optimized for high speed operation. In this study, we fabricated and investigated sheet resistance of Pd and PdAu thin film, and simulated the inductance effect of the shunt resistor to the Josepshon junction dynamics.

  • PDF

Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator (저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발)

  • Lee, Young Seob;Jung, Jae Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

Performance of Microbial Fuel Cell Integrated with Anaerobic Membrane Filter for Continuous Sewage Treatment with Stable Effluent Quality (안정적 유출수질의 연속 하수처리를 위한 혐기성 멤브레인 필터와 통합된 미생물연료전지의 성능 평가)

  • Lee, Yunhee;Oa, Seong-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.808-812
    • /
    • 2013
  • A new type of microbial fuel cell (MFC) with anaerobic membrane filter was designed to produce bioelectricity and to treat domestic sewage at relatively high organic loading rate (OLR) of $6.25kgCOD/m^3/day$ and short hydraulic retention time (HRT) of 1.9 h. A following aeration system was applied to ensure effluent water quality in continuous operation. Glucose was supplemented to increase the influent concentration of domestic sewage. Influent substrate of 95% was removed via the MFC and following aeration system and the corresponding maximum power density was $25.6mW/m^3$. External resistor of $200{\Omega}$ and air-cathode system contributed better MFC performance comparing to $2000{\Omega}$ and dissolved oxygen as a catholyte.

Design of a Novel Instrumentation Amplifier using Current-conveyor(CCII) (전류-컨베이어(CCII)를 사용한 새로운 계측 증폭기 설계)

  • CHA, Hyeong-Woo;Jeong, Tae-Yun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.80-87
    • /
    • 2013
  • A novel instrumentation amplifier(IA) using positive polarity current-conveyor(CCII+) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of two CCII+, three resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into two CCII+ used voltage and current follower converts into same currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the CCII+ and used commercial op-amp LF356. Simulation results show that voltage follower used CCII+ has offset voltage of 0.21mV at linear range of ${\pm}$4V. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the gain of 60dB was 400kHz. The IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 130mW at supply voltage of ${\pm}$5V.

A Design of Novel Instrumentation Amplifier Using a Fully-Differential Linear OTA (완전-차동 선형 OTA를 사용한 새로운 계측 증폭기 설계)

  • Cha, Hyeong-Woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • A novel instrumentation amplifier (IA) using fully-differential linear operational transconductance amplifier (FLOTA) for electronic measurement systems with low cost, wideband, and gain control with wide range is designed. The IA consists of a FLOTA, two resistor, and an operational amplifier(op-amp). The principal of the operating is that the difference of two input voltages applied into FLOTA converts into two same difference currents, and then these current drive resistor of (+) terminal and feedback resistor of op-amp to obtain output voltage. To verify operating principal of the IA, we designed the FLOTA and realized the IA used commercial op-amp LF356. Simulation results show that the FLOTA has linearity error of 0.1% and offset current of 2.1uA at input dynamic range ${\pm}3.0V$. The IA had wide gain range from -20dB to 60dB by variation of only one resistor and -3dB frequency for the 60dB was 10MHz. The proposed IA also has merits without matching of external resistor and controllable offset voltage using the other resistor. The power dissipation of the IA is 105mW at supply voltage of ${\pm}5V$.

Hysteretic behavior in polymer stabilized ferroelectric liquid crystal

  • Lee, Ji-Hoon;Lim, Tong-Kun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.334-337
    • /
    • 2005
  • We have found that the hysteretic behavior of a polymer stabilized ferroelectric liquid crystal system coincides with Blinov et. al's model qualitatively. The hysteresis inversion frequency could be promoted up to 7000 Hz by connecting external capacitor and resistor in serial. In addition, the influence of temperature and the amplitude of the applied field on hysteresis-free switching of the cell could be minimized.

  • PDF