• Title/Summary/Keyword: External and internal stability

Search Result 277, Processing Time 0.024 seconds

A Study on Stability of Marine Embankment Using Reliability Analysis (신뢰성해석을 이용한 호안제체의 안정성에 관한 연구)

  • 박준모;장연수;오세웅
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.789-796
    • /
    • 2003
  • A reliability analysis is performed to investigate the influence of the uncertainty from the limited in-situ samples and the inherent heterogeneity of the ground on the probability of piping for the marine embankment near shore. The result are compared with those of the deterministic piping stability analysis performed using the fininte element flow analysis. The random variables used are hydraulic conductivity of the ground subsurface and embankment, and the water level of both internal and external side of the embankment. The probability of piping is most sensitive to the mean and standard deviation of internal water level of the embankment among the random variables included in the reliability analysis. It is found that the lower limits of internal water level which satisfies the allowable proability of piping failure for the embankment studied were E.L(-) 1.83m and E.L(-) 1.48m during and after the construction of the embankment, respectively.

  • PDF

Comparison of Abdominal Muscle Activity according to Plank Exercise, Side Plank Exercise, and Crunch Exercise (플랭크 운동, 사이드 플랭크 운동, 그리고 크런치 운동에 따른 배근육의 근활성도 비교)

  • Chung-Yoo Kim;Won-Sik Bae
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.1
    • /
    • pp.159-166
    • /
    • 2023
  • Purpose : The purpose of this study was to compare the differences in muscle activity of the rectus abdominis, internal oblique, and external oblique muscles according to abdominal muscle exercise methods such as plank exercise, side plank exercise, and crunch exercise. Methods : This study was conducted with 37 college students. All subjects participating in this study were randomly assigned to the plank exercise group, the side plank exercise group, and the crunch exercise group. The exercise corresponding to each group was performed for a total of 8 weeks. The muscle activity of the abdominal muscles was measured before the experiment, 4 weeks, and 8 weeks, and the rectus abdominis, internal oblique, and external oblique muscles were measured. Results : As a result of comparison according to the period in the change in muscle activity of the abdominal muscles after exercise, the amount of change in muscle activity in all three muscles showed a significant difference. As a result of the post-hoc analysis, the muscle activity value of the internal oblique muscle after 4 weeks in the plank exercise showed a significant difference from the value after 8 weeks. In the side plank exercise, the muscle activity values of the rectus abdominis and external oblique muscles before and after 4 weeks showed significant differences from those after 8 weeks. And in the crunch exercise, the muscle activity value of the rectus abdominis muscle before exercise showed a significant difference from the value after 8 weeks. Conclusion : Plank exercise increases the muscle activity of the rectus abdominis, side plank exercise increases the rectus abdominis and external oblique muscles, and crunch exercise increases the muscle activity of the rectus abdominis. Therefore, it is thought that the stability of the trunk can be improved more efficiently if all three exercises are performed.

Internal Model Control for Unstable Overactuated Systems with Time Delays

  • Mahmoud, Ines;Saidi, Imen
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.1
    • /
    • pp.64-69
    • /
    • 2021
  • In this paper, we have proposed a new internal model control structure (IMC). It is aimed at unstable overactuated multivariable systems whose transfer matrices are singular and unstable. The model inversion problem is essential to understand this structure. Indeed, the precision between the output of the process and the setpoint is linked to the quality of the inversion. This property is preserved in the presence of an additive disturbance at the output. This inversion approach proposed in this article can be applied to multivariable systems with no minimum phase or minimum phase shift with or without delays in their transfer matrices. It is proven by an example of simulation through which we have shown its good performance as a guarantee of stability, precision as well as rapidity of system responses despite the presence of external disturbances and we have tested this control structure in the frequency domain hence the robustness of the IMC.

Model Tracking Dual Stochastic Controller Design Under Irregular Internal Noises

  • Lee Jong-Bok;Cho Yun-Hyun;Ji Tae-Young;Heo Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.652-657
    • /
    • 2006
  • Although many methods about the control of irregular external noise have been introduced and implemented, it is still necessary to design a controller that will be more effective and efficient methods to exclude for various noises. Accumulation of errors due to model tracking, internal noises (thermal noise, shot noise and 1/f noise) that come from elements such as resistor, diode and transistor etc. in the circuit system and numerical errors due to digital process often destabilize the system and reduce the system performance. New stochastic controller is adopted to remove those noises using conventional controller simultaneously. Design method of a model tracking dual controller is proposed to improve the stability of system while removing external and internal noises. In the study, design process of the model tracking dual stochastic controller is introduced that improves system performance and guarantees robustness under irregular internal noises which can be created internally. The model tracking dual stochastic controller utilizing F-P-K stochastic control technique developed earlier is implemented to reveal its performance via simulation.

THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND PRELOAD OF DIFFERENT CONNECTION TYPES IMPLANT WITH INITIAL CLAMPING (임플랜트의 체결방식에 따른 초기조임력에 의한 응력분포 및 전하중에 관한 연구)

  • Lee Bum-Hyun;Chun Heoung-Jae;Lee Soo-Hong;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.197-206
    • /
    • 2006
  • Statement of problem: One of common problems associated with single teeth dental implant prosthetic is the loosening of screws that retain the implants. Purpose: The maintenance of screw joint stability is considered a function of the preload achieved in the screw when the suggested initial tightening torque is applied. The purpose of this study was to investigate acquired preload after initial clamping torque for estimating screw joint stability. Material and methods: A comparative study on the effect of initial clamping of two types of implant systems with different connections was conducted Three dimensional non-linear finite element analysis is adopted to compare the characteristics of screw preloads and stress distributions between two different types of implant systems composed with abutment, screw, and fixture under the same loading and boundary conditions. Results: 1. When the initial clamping torque of 32Ncm was applied to the implant systems, all types of implants generated the maximum effective stress at the first helix region of screw. 2. Morse taper connection types of implants generate lower stress distributions compared to those by butt joint connection types or implants due to large contact surface between abutment and fixture. 3. The internal types of implant systems with friction grip type implant systems have higher resistance to screw loosening than that of the external types of implant systems since the internal types of implant systems generated larger preload than that generated by the external types for the same tightening moments.

An Evaluating Analysis of Installing Type of EOTS for The Boramae Fighter (보라매 전투기 전자광학타겟팅 장비 탑재형태의 분석 평가)

  • Kang, Chi-Hang;Oh, Seung-Hyun;Kang, Hee-Chang;Cheon, Ho-Jeong;Lee, Beom-Seok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.10
    • /
    • pp.910-915
    • /
    • 2012
  • In this paper, the loading methods of EOTS for an exploratory developing fighter were analysed by the technical characteristics of it's operation, maintenance, engineering technology and development cost. By the analysis of operational ability evaluation, the internal type had the merits of stealth function, but the external loading type was preferable to certificate the accessibility, install/detach, compatibility and interoperability with the existing fighter aircraft. From the results of 17 items of technology and development cost evaluation, we found out that the internal type had the advantage of small sizing lightweight, but the external type was highly estimated in the field of application of domestic technology, cost reduction and technical stability for achievement of performance.

Dynamic Stability Analysis of Nonconservative Systems for Variable Parameters using FE Method (유한요소기법을 이용한 비보존력이 작용하는 보-기둥 구조의 다양한 제변수 변화에 따른 동적 안정성 해석)

  • Lee Jun-Seok;Min Byoung-Cheol;Kim Moon-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.351-363
    • /
    • 2004
  • Equation of motion of non conservative system considering mass matrix, elastic stiffness matrix, load correction stiffness matrix by circulatory force's direction change and Winkler and Pasternak foundation stiffness matrix is derived. Also stability analysis due to the divergence and flutter loads is performed. And the influence of internal and external damping coefficient on flutter load is investigated applying the quadratic eigen problem solution. Additionally the influence of non-conservative force's direction parameter, internal and external damping and Winkler and Pasternak foundation on the critical load of Beck's and Leipholz's and Hauger's columns are investigated.

The Effects of Pilates based Breathing on Changes in the Thicknesses of the Abdominal Muscles

  • Kwon, Hae-Yeon;Moon, Hyun-Ju;Kim, Moon-Jeoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.3
    • /
    • pp.59-63
    • /
    • 2016
  • PURPOSE: The purpose of the present study is to examine the effects of sole Pilates based breathing on the thicknesses of the abdominal muscles. METHODS: Twenty adults aged in their 20-30s were randomly selected. The selection criteria were those who had no medical history of pain due to musculoskeletal system, neurologic, or orthopedic diseases within six months before the selection. The thicknesses of the abdominal muscles (the transversus abdominis muscle, internal oblique abdominal muscle, and external oblique abdominal muscle) of the subjects were measured using ultrasonography before and after Pilates breathing. The study was approved by the research ethics committee of the Catholic University of Pusan. RESULTS: After Pilates based breathing, the thicknesses of the transversus abdominis muscle, the internal oblique abdominal muscle, and the external oblique abdominal muscle increased significantly. In particular, the thickness increase rate of the transversus abdominis muscle was shown to be the highest. CONCLUSION: Sole Pilates based breathing is expected to be effective for the improvement of trunk stability through strengthening of abdominal muscles, because it induces the coordinated contraction of the transversus abdominis muscle and other abdominal muscle. It will be need the Longitudinal study for identify to long term effects of Pilates based breathing.

A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT PROSTHESES ACCORDING TO THE HEX-LOCK TYPE (단일 임플랜트 보철물의 Hex-lock 형태에 따른 3차원 유한요소법적 응력분석)

  • Hwang, Young-Pil;Kay, Kee-Sung;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.385-402
    • /
    • 1996
  • The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.

  • PDF

Examination of GC-TD sensitivity for reduced sulfur compounds in relation to temporal stability and reproducibility (환원 황화합물의 열탈착 분석기법에 대한 감도의 경시변화 및 재현성에 대한 연구)

  • Hong, One-Feel;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.24-35
    • /
    • 2010
  • To learn more about the calibration properties of reduced sulfur compounds (RSCs) by the combination of gas chromatography(GC)-pulsed flame photometric detector (PFPD) and thermal desorption method, a series of calibration experiments were conducted on the basis of both internal and external calibration approaches. For these experiments, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) were prepared at two different concentration levels of both low (10, 20, 50,and 100 ppb) and high ranges (100, 200, 500, and 1000 ppb) along with $CS_2$ as an internal standard. First, the external calibration results were compared between fixed standard volume (FSV) and fixed standard concentration (FSC) method. Secondly, FSV-based calibration results were compared between external and internal calibration results. As FSV method suffers from sensitivity variations less significantly than FSC, the former is recommended to maintain the consistency in GC-TD sensitivity for RSC analysis. In addition, when the calibration data were examined in terms of RSE between external and internal calibration data, the results were not consistent enough to show improvements in internal method. Hence, diverse efforts are desirable to optimize the reproducibility in terms of GC-TD sensitivity for RSC analysis.