• Title/Summary/Keyword: External Wall

Search Result 560, Processing Time 0.04 seconds

Analysis of the Types of External Wall and Roof Structure Layer Composition of CLT Building (CLT 건축물의 외벽 및 지붕 구조체 레이어 구성 유형 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.4
    • /
    • pp.71-78
    • /
    • 2020
  • Today, the whole world is going through a big chaos due to the COVID-19, but paradoxically, the emergence of COVID-19 has been leading to the need for sustainable development, such as Green New Deal that can improve global warming and carbon emissions, and the need for sustainable architecture is growing bigger and bigger in the architectural field as well. The level of CLT buildings in Korea is at a very rudimentary stage, while CLT buildings remedying existing wooden buildings are getting the spotlight among European countries for sustainable architecture. This study was conducted to categorize structure layer compositions of overseas CLT buildings and analyze architectural techniques and materials applied by collecting and analyzing information about CLT structure layer compositions of overseas CLT building-related institutions, companies and cases. When classifying structure layer compositions of foreign CLT buildings depending on the roles of layers. it was revealed that exterior wall structure layers were combined and organized within a sequence of external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, sloped roof structure layers were external finishing, ventilation, waterproof, board, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing, flat roof structure layers were external finishing, ventilation, waterproof, planking wood, external insulation, waterproof, external insulation, airtightness, structure, airtightness, interior insulation, interior finishing.

Physical protection system vulnerability assessment of a small nuclear research reactor due to TNT-shaped charge impact on its reinforced concrete wall

  • Moo, Jee Hoon;Chirayath, Sunil S.;Cho, Sung Gook
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2135-2146
    • /
    • 2022
  • A nuclear energy facility is one of the most critical facilities to be safely protected during and after operation because the physical destruction of its barriers by an external attack could release radioactivity into the environment and can cause harmful effects. The barrier walls of nuclear energy facilities should be sufficiently robust to protect essential facilities from external attack or sabotage. Physical protection system (PPS) vulnerability assessment of a typical small nuclear research reactor was carried out by simulating an external attack with a tri-nitro toluene (TNT) shaped charge and results are presented. The reinforced concrete (RC) barrier wall of the research reactor located at a distance of 50 m from a TNT-shaped charge was the target of external attack. For the purpose of the impact assessment of the RC barrier wall, a finite element method (FEM) is utilized to simulate the destruction condition. The study results showed that a hole-size of diameter 342 mm at the front side and 364 mm at the back side was created on the RC barrier wall as a result of a 143.35 kg TNT-shaped charge. This aperture would be large enough to let at least one person can pass through at a time. For the purpose of the PPS vulnerability assessment, an Estimate of Adversary Sequence Interruption (EASI) model was used, which enabled the determination of most vulnerable path to the target with a probability of interruption equal to 0.43. The study showed that the RC barrier wall is vulnerable to a TNT-shaped charge impact, which could in turn reduce the effectiveness of the PPS.

The effect of wall squat exercise according to the difference in the support surface on the muscle thickness and balance of the trunk (지지면 차이에 따른 월 스쿼트 운동이 몸통 근두께와 균형에 미치는 영향)

  • Jeong, Jin Gyu;Park, Jae Cheol
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.1
    • /
    • pp.64-72
    • /
    • 2022
  • Background: The purpose of this study is to investigate the effect of wall squat exercise according to the difference in the support surface on the thickness change of external oblique, internal oblique and transverse abdominalis of the trunk muscles and the change in distance of center of pressure when the eyes are opened and closed. Design: Randomized controlled trial. Methods: The subjects were 26 healthy adults, 18 males and 8 females. The composition of each group using the single-blind method was 13 people in the unstable side wall squat exercise group and 13 people in the stable side wall squat exercise group. Experimental measurements were divided into before, 3 weeks, and 6 weeks after the experiment, and changes in muscle thickness and balance were confirmed. Muscle thickness was measured using ultrasinic, and static balance change was measured using Bio-rescue. Results: There were significant differences in the thickness changes of external oblique, internal oblique and transverse abdominalis according to the wall squat exercise method by period and in the interaction between the period and the group (p<0.05). As a result of the post-hoc analysis, there was a significant difference in the change between the two groups in external oblique muscle after 6 weeks. And there was a significant difference in the distance of the pressure center between eyes open and closed eyes (p<0.05). Conclusion: In terms of instability, wall squat exercise was positive for changes in trunk muscle thickness. It suggests the possibility of using it for trunk muscle strengthening training in the future.

The Three -Dimensional Stability Analysis of the Diaphragm Wall under the Influence of External Loads (상재하중의 영향을 고려한 Diaphragm Wall의 3차원 안정도 해석)

  • Gu, Ja-Gap;Lee, Sang-Deok;Jeon, Mong-Gak
    • Geotechnical Engineering
    • /
    • v.7 no.3
    • /
    • pp.43-50
    • /
    • 1991
  • To analyze the effects of ground water levels and external loads on the stability of a Dia- phragm wall, the three models of Bell, Piaskowski/kowalewski, and Washbourne were modified and extended to develop a new program SL3D. Comparing to the other two models, Washbourne's model shows the stability in on safes at the beginning of the excavation and increase as the excavation continue . Also the effects of various design factors, such as the density of slurry, ground water levels, the friction angle of soil, external loads and the length of trench, have been analyzed and a nomogram was developed.

  • PDF

An Algorithm to Speed Up the Rapid Prototyping (쾌속조형의 속도를 향상시키기 위한 알고리즘)

  • Ko, Min-Suk;Chang, Min-Ho;Wang, Gi-Nam;Park, Sang-Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.3
    • /
    • pp.157-164
    • /
    • 2008
  • While developing physical prototype from CAD model, rapid prototyping mainly focuses on two key points reducing time and material consumption. So, we have to change from a traditional solid model to building a hollowed prototype. In this paper, a new method is presented to hollow out solid objects with uniform wall thickness to increase RP efficiency. To achieve uniform wall thickness, it is necessary to generate internal contour by slicing the offset model of an STL model. Due to many difficulties in this method, this paper proposes a new algorithm that computes internal contours computing offset model which is generated from external contour using wall thickness. Proposed method can easily compute the internal contour by slicing the offset surface defined by the sum of circle swept volumes of external contours without actual offset and the circle wept volumes. Internal contour existences are confirmed by using the external point. Presented algorithm uses the 2D geometric algorithm allowing RP implementation more efficient. Various examples have been tested with implementation of the algorithm, and some examples are presented for illustration.

Analysis of the Energy Saving Effect for the External Insulation Construction by Building Load Calculation Method (건물 부하계산 프로그램을 이용한 외단열 시공의 에너지 절감 효과 분석)

  • Park, Jaejoong;Myeong, Jemin;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.3
    • /
    • pp.97-104
    • /
    • 2017
  • Reinforcement of insulation in apartment buildings reduces the heating and cooling energy consumption by lowering the heat transfer in the building envelope. There are differences between internal and external insulation methods in heat transmission properties. However, some building load calculation programs cannot analysis the differences between the two. This is because these programs do no account for the timelag or thermal storage effect of the wall according to the location of insulation. In this study, the heat transmission characteristics of internal and external insulation were analyzed by EnergyPlus, and heating and cooling energy demand was compared. The results showed that external insulation system had lower heating and cooling loads than internal insulation system. Also the heat transfer rate of external insulation is steadier than internal insulation. About 13.6% of heating and cooling energy demand decreased when the outdoor wall was finished with external insulation compared to the demand with internal insulation.

A Study on the Architectural Characteristics and Facade Construction of the Brick Masonry Auditorium in Daegu During the Modern Age - Focused on the Auditorium of Namsan Primary School - (근대기 대구지역 벽돌조 강당 건물의 건축특성과 파사드 구성에 관한 연구 - 남산초등학교 강당을 중심으로 -)

  • Yoon, Jae-Woong
    • Journal of architectural history
    • /
    • v.19 no.6
    • /
    • pp.121-135
    • /
    • 2010
  • This study was to analyze the architectural characteristics and facade construction of brick masonry auditorium through the Auditorium of Namsan Primary School in 1936. The results of this study were described separately as follows. 1. The auditorium is located away from the school buildings, and its plane is a chamber of rectangle type with an entrance installed on each of the four sides. 2. The external appearance is Renaissance eclectic style, laid red bricks on the lower wall of the window and having a mansard roof. The front and the rear are symmetric with respect to the projected wall at the center. 3. As to the structure of the building, a concrete lower wall was built on the concrete continuous footing, and the brick wall was constructed on the lower wall. The roof is queen post roof truss, and the wall girders were installed on the brick wall. 4. The auditorium has had a number of repairing and maintenance works, which changed the roof and windows outside and the floor, walls, ceiling, etc. inside. 5. The decorative elements of external appearance include lower wall, brick wall, entrances, windows, roof, and dormer windows. The brick wall gives verticality and solidity to the surface of the wall, and the lower wall and wall girders are connected like a cornice of the wall. The surface of the mansard roof and dormer windows express a stable vertically oriented shape.

A Self-contained Wall Climbing Robot with Closed Link Mechanism

  • Park, Hyoukryeol;Park, Jaejun;Taehun Kang
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.573-581
    • /
    • 2004
  • A self-contained wall climbing robot, called MRWALLSPECT (Multi-functional Robot for WALL inSPECTion) II, is developed. It is designed for scanning external surfaces of gas or oil tanks with small curvature in order to find defects. The robot contains all the components for navigation in itself without any external tether cable. Although it takes the basic structure of the sliding body mechanism, the robot has its original characteristic features in the kinematic design with closed link mechanism, which is enabled by adopting a simple and robust gait pattern mimicking a biological system. By employing the proposed link mechanism, the number of actuators is reduced and high force-to-weight ratio is achieved. This paper describes its mechanism design and the overall features including hardware and software components. Also, the preliminary results of experiments are given for evaluating its performances.

Analysis of External Fibrillation of Fiber by Confocal Reflection Microscopy (공초점반사현미경법을 이용한 섬유의 외부소섬유화 분석)

  • Kwon, Ohkyung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.46 no.2
    • /
    • pp.35-45
    • /
    • 2014
  • Confocal Reflection Microscopy (CRM) was applied to investigate external fibrillation of different types of fibers such as Kajaani reference fiber, Whatman filter fiber, thermomechanical pulp (TMP), and recycled TMP fiber. It was confirmed that the CRM images are created from surface structures of the fiber cell wall. Confocal Laser Scanning Microscopy (CLSM) captured overall shape of the fiber, but minute details of the surface of the fiber were missed. CRM captured the minute details of the fiber surface. From the CRM and CLSM images, it was observed that the CRM images mainly appeared on the fiber surfaces. External fibrillation of the fiber occurs at the fiber surface, not inside the cell wall. Thus, it was concluded that investigation on the external fibrillation of the fiber was possible by utilizing CRM images. A direct qualtitative and quantitative method for analysis of external fibrillation of fiber was demonstrated by utilizing surface area to volume ratio, volume fraction, and roughness calculated from 3-dimensional images reconstructed from stacks of CRM images from the different fibers.

External Auditory Canal Atresia with Otitis Media in a Dog

  • Kim, Ah Reum;Han, Changhee;Hwang, Gunha;Kim, Rakhoon;Go, Woohyun;Lee, Ji Yeong;Lee, Jongbong;An, Soyon;Hwang, Tae Sung;Lee, Dongbin;Lee, Jae-Hoon;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.38 no.3
    • /
    • pp.159-162
    • /
    • 2021
  • A 5-year-old, intact male, poodle dog with right external auditory canal obstruction and subaural mass was presented. Physical examination revealed that right external auditory canal opening was absent and right head tilt was identified. Aspiration in right subaural mass revealed a small amount of dark brown exudate. Streptococcus canis and Staphylococcus spp. were identified on the microbial culture. Radiography of the skull was revealed absence of air-filled ear canal at the right external ear canal (EEC) level. Computed tomography (CT) revealed well capsulated, hypoattenuated mass in the right EEC region. On the contrast enhanced CT images, rim enhancement around the mass and ear canal obstruction were identified. Fluid attenuated material filled with right bulla. Mild thickening of the right tympanic bulla wall with mild lytic lesion of the ventral wall were found. Based on the images findings, the case was tentatively diagnosed as right external auditory canal atresia with otitis media. Total ear canal ablation and lateral bulla osteotomy was performed. The entire ear canal was removed, numerous hair in the canal and the thickening wall were founded. Right ear canal was sent for histopathological evaluation and found to otitis externa. The patient was followed up for two weeks and there were no complications. This report described the CT diagnosis of right EEC atresia with otitis media rarely reported in small breed dogs.