• 제목/요약/키워드: External Wall

검색결과 560건 처리시간 0.025초

층간변위 흡수형 커튼월 슬리브의 경제성 평가 (Economic Evaluation of Absorption Curtain Wall Sleeve with Relative Storey Displacement)

  • 홍상훈;유남규;서은석;김해나;김봉주;정의인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 춘계 학술논문 발표대회
    • /
    • pp.163-164
    • /
    • 2019
  • Curtain wall is constructed in various forms and designs by forming the exterior walls of a building, and refers to non-bearing walls that divide the exterior and interior spaces of a building. Curtain walls require not only wind pressure, but also waterproof, insulation, insulation, and durability, as well as the effects of recent frequent earthquakes. Studies on the sleeve used to connect the vertical member mullions in the process of high-rise curtain walls are insufficient. In this study, sleeves connecting curtain wall mullions were developed to absorb external displacement, and the purpose of this study was to evaluate economic feasibility through comparison with existing construction methods.

  • PDF

고성토 보강토옹벽의 거동에 관한 사례연구 (A Case Study on Behavior of High-Raised Reinforced Soil Wall)

  • 조삼덕;이광우;이훈연;장기수
    • 한국지반신소재학회논문집
    • /
    • 제5권4호
    • /
    • pp.35-42
    • /
    • 2006
  • 최대 높이가 29.5m인 고성토 보강토옹벽에 대한 시공 및 계측이 수행되었다. 이와 같이 높은 보강토옹벽에 대한 설계 및 시공 경험이 그다지 많지 않기 때문에, 본 현장에서는 철저한 설계 및 시공관리가 이루어졌다. FHWA 설계기준에 근거하여 본 현장 보강토옹벽의 내적 및 외적안정을 검토하였고, Bishop의 간편법을 이용하여 전반활동에 대한 안정성 해석을 수행하였다. 또한 시공관리 및 안정성 검토를 위한 일련의 현장계측을 수행하였다. 본 논문에서는 높이가 20m 이상이고, 2단으로 시공된 대표단면 2개소에 대한 계측결과를 분석하였다. 계측결과, 벽체 및 보강재의 변형이 매우 작게 측정되었으며, 벽체작용 수평토압 또한 미소한 것으로 나타났다. 따라서 높이가 20m이상으로 매우 높은 옹벽구조물에 있어서, 보강토옹벽공법이 성공적으로 적용될 수 있음을 확인하였고, 또한 시공관리가 잘 이루어질 경우 이같이 높은 보강토옹벽에 대하여 FHWA 설계기준이 매우 보수적인 안전측 결과를 보임을 알 수 있었다.

  • PDF

NUMERICAL ANALYSIS FOR UNSTEADY THERMAL STRATIFIED FLOW WITH HEAT TRACING IN A HORIZONTAL CIRCULAR CYLINDER

  • Jeong, Ill-Seok;Song, Woo-Young;Park, Man-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.304-309
    • /
    • 1997
  • A method to mitigate the thermal stratification flow of a horizontal pipe line is proposed by heating external bottom of the pipe with electrical heat tracing. Unsteady two dimensional model has been used to numerically investigate an effect of the external Denting to the thermally stratified flow. The dimensionless governing equations are solved by using the control volume formulation and SIMPLE algorithm. Temperature distribution, streamline profile and Nusselt numbers of fluids and pipe walls with time are analyzed in case of externally heating condition. no numerical result of this study shows that the maximum dimensionless temperature difference between the hot and the cold sections of pipe inner wall is 0.424 at dimensionless time 1,500 ann the thermal stratification phenomena is disappeared at about dimensionless time 9,000. This result means that external heat tracing can mitigate the thermal stratification phenomena by lessening $\Delta$ $T_{ma}$ about 0.1 and shortening the dimensionless time about 132 in comparison with no external heat tracing.rnal heat tracing.

  • PDF

가정용 냉장고의 단열 최적화 (Optimization of Heat Insulation System for a Household Refrigerator)

  • 박진구
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.95-102
    • /
    • 2003
  • Optimization for the insulation thickness and external shape of a household refrigerator is peformed in order to minimize thermal load through the insulation wall. The one dimensional conduction heat transfer model is adopted to calculate thermal load. Calculus of variation is employed to optimize the thickness and shape of refrigerator or freezer. The uniform distribution of an insulation thickness and cubed external shape make thermal load minimize. Finally, by using both of the computational and experimental method, the thermal load is minimized for a refrigerator/freezer. It is shown that there exists optimal thickness of insulation walls and external shape for given the external cabinet dimensions and freezer and refrigerator internal volumes, Also, the analytical results are well agreed with the experimental results.

External Field Dependence of $Fe^57$ NMR in Pure Iron

  • Dho, Joongheo;Kim, Mincheol;Lee, Soonchil;Lee, Wonjong;Kim, Yoonbae
    • Journal of Magnetics
    • /
    • 제1권1호
    • /
    • pp.14-18
    • /
    • 1996
  • The NMR spin echo in pure iron was measured as a function of external magnetic field up to 10 kgauss at room temperature. We observed the signal coming from a single domain formed over 7.5 kgauss which has not been detected in previous works. The resonance frequency shift with external field confirmed that the hyperfine field in iron is -330.2 kgauss. From the comparison of the magnetization curve with the domain wall signal and the resonance frequency in external field, we showed that NMR could give the useful qualitative information on the magnetization process. The extent of the internal strain removed by annealing, which can be hardly seen in hysteresis curves, was clearly shown up in the NMR line-width.

  • PDF

건축용 비내력 경량벽체의 정적 수평하중저항성 시험방법의 표준화 (Standardization of Stiffness Test Method of Non-bearing Lightweight Wall for building)

  • 김진식;최수경
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.185-186
    • /
    • 2015
  • The use of non-bearing lightweight wall has increased recently due to the increase of high-rise buildings and supply of long-life housing. Lightweight wall has advantages such as reducing the self-weight of the building, convenience in installation, and shortening construction period, however, must have a sufficient strength to external force. This study standardized the stiffness (static horizontal load resistance) test method for lightweight walls by using the actual impact load obtained through the load analysis test conducted in the previous studies. The size of specimen was set up as height 2.4m and width 3.0m. Test apparatus and test methods were referred to BS 5234-2:1992. However, the loading level applied to the specimen was divided into 3 steps (3000N, 1000N, 500N) that can be applied selectively depending on the purpose of the wall. The deformation characteristics according to the same loading level were vary depending on the specimen's type, and the evaluation criteria for functional damage may vary depending on the material, method of construction, and purpose of wall. Therefore, we did not suggest unified evaluation criteria of the stiffness to the test results.

  • PDF

외부화염에 의한 드라이비트의 소손패턴 연구 (A Study on the Damaged Pattern of Dryvit by External Flame)

  • 박영주;홍이표;이해평
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.40-47
    • /
    • 2015
  • In this study, temperature characteristics and fire damage form were analyzed to investigate flame spreading form and fire probability from ignition sources subject to drivit component materials which is finishing material in architecture. Ignition sources were limited to a gas torch and exterior panel board fire, and the size of the sample was manufacture in 30 cm length ${\times}$ 50 cm height ${\times}$ 5cm thickness size. Marble (inner wall) + 3 mm drivit (outer wall), marble (inner wall) + 4 mm plaster stone (outer wall), sandwich panel + 3 mm driver bit (outer wall), sandwich panel + 3 mm driver bit + insulation (outer wall), and gypsum board (inner wall) + 3 mm drivit (outer wall) were prepared for the sample. As result of the research for temperature characteristics, large temperature difference by each material was shown in $218^{\circ}C{\sim}995^{\circ}C$ at 30 seconds and $501^{\circ}C{\sim}1078^{\circ}C$ at 300 seconds. Especially when the inner wall was a plaster board, lowest temperature of $501^{\circ}C$ was shown at 300 seconds and marble inner wall showed the following lowest temperature of $900^{\circ}C$. Temperature rising over $1000^{\circ}C$ was shown in other materials. Regarding fire damage form, drivit or gypsum board outer wall parts exposed to fire showed combustion and carbonization to show calcination(breaking phenomenon) and influence of heat exposure was higher as calcination became more severe.

고속도로 도로부에 시공된 패널식 보강토 옹벽의 높이별 안전율과 경제성 검토 (A Study on Stability and Economic feasibility according to Height on the MSE Wall with Pacing Panel)

  • 박민철
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.54-63
    • /
    • 2018
  • 본 연구에서는 고속도로 도로부의 표준단면을 대상으로 패널식 보강토 옹벽의 높이별 안전율과 경제성에 대해 비교 검토하였다. 설계기준에 따라 하중조건은 고속도로의 단면 및 형상조건을 고려하여 콘크리트 포장의 사하중과 차량하중을 재하하고 최상단 보강재의 경우 방호벽의 충돌하중을 고려하였다. 보강재의 길이는 보강토 옹벽의 높이에 따라 0.9H로 배치하였기 때문에, 보강토체의 형상에 따라 지배되는 외적 안정성에 대해 높이의 증가에 따른 영향은 거의 없는 것으로 나타났다. 지지력에 대한 안전율은 보강토 옹벽의 높이에 따라 자중이 증가되기 때문에 급격히 감소되었다. 복합중력식 설계법에 따른 내적 안정성을 검토한 결과, 인발 안전율은 증가되고 파단 안전율은 감소되었다. 보강토 옹벽의 높이가 증가될수록 활동력으로 작용되는 수평토압과 저항력으로 작용되는 수직토압이 함께 증가되기 때문에 인발의 안전율은 증가되었다. 돌기형 강재 보강재의 장기 허용인장력은 상수이기 때문에, 높이에 따라 활동력에 대한 안전율은 수평토압이 증가되어 감소되었다. 블록식 보강토 옹벽보다는 패널식 보강토 옹벽의 경제성이 우수한 것으로 나타났고, 기존 옹벽과 비교하면 5.0 m이상의 높이에서 패널식 보강토 옹벽의 경제성이 가장 우수한 것으로 나타났다.

박공지붕형 저층건축물의 지붕 및 벽면에 작용하는 피크외압의 분포 특성 (Characteristics of Peak External Pressure Acting on the Roof and Wall of the Low-Rise Buildings with Gable Roofs)

  • 조원근;원종호;하영철
    • 한국강구조학회 논문집
    • /
    • 제21권3호
    • /
    • pp.245-255
    • /
    • 2009
  • 산업용 건축물은 일반적으로 박공지붕형 저층의 형태로 많이 건설된다. 본 연구는 박공지붕형 저층건물의 풍압분포와 특성을 알아보기 위하여 풍동실험을 수행하였다. 풍동실험은 경사각 변화에 따른 외장재용 피크외압계수 분포양상을 알아보기 위하여 동일한 폭과 높이, 길이를 가지지만 지붕 경사각이 서로 다른 7가지의 모형을 제작하여 실험하였다. 실험결과 지붕과 벽면의 모서리 부분에서 최대 피크외압계수가 나타났으며, 이를 KBC-2005 및 각국의 기준과 비교하여 보았다. 실험에 의한 피크외압계수는 AIJ-2004와 매우 유사하게 나타났지만 KBC -2005보다는 다소 크게 나타났다.

Rhodotorula glutinis K-24에 의해 구성적으로 생산되는 세포외 Invertase의 정제 및 특성 (Purification and Characterization of the External Invertase Constitutively Produced by Rhodotorula glutinis K-24)

  • 최미정;김철;이상옥;이태호
    • 한국미생물·생명공학회지
    • /
    • 제18권4호
    • /
    • pp.368-375
    • /
    • 1990
  • 세포내 및 세포벽 뿐만 아니라, 세포외에도 invertase를 구성적으로 생산하는 효모 Rh.glutinis K-24로 부터 세포외 invertase를 disc 전기 영동상으로 단일한 상태로까지 정제하였다. 정제 효소의 효소화학적 성질을 밝힌 후 이미 보고한 바 있는 세포내 및 세포벽 invertase와 그 개락적 성질을 비교 검토하였다.

  • PDF