A Case Study on Behavior of High-Raised Reinforced Soil Wall

고성토 보강토옹벽의 거동에 관한 사례연구

  • Received : 2006.10.02
  • Accepted : 2006.12.04
  • Published : 2006.12.30

Abstract

This paper describes a field experience on geogrid-reinforced soil walls rising up to 29.5m in height. Since experiences of design and construction on very high-raised geogrid reinforced soil wall were limited, thorough design and construction management was performed for safe construction of the wall. Regarding design of the wall, both internal and external stabilities were examined based on the design guideline specified by FHWA and overall slope stability analyses were performed by using Bishop simplified method. Moreover, a series of instrumentations were performed. The results of instrumentation for two tiered reinforced soil wall showed that not only the deformations of both the wall face and the reinforcement but also the horizontal earth pressures acting on the wall facing were very small. These results indicate that the reinforced soil wall technology can be applied successfully for high-raised tiered wall more than 20m heights and FHWA design guideline is very conservative for that large wall.

최대 높이가 29.5m인 고성토 보강토옹벽에 대한 시공 및 계측이 수행되었다. 이와 같이 높은 보강토옹벽에 대한 설계 및 시공 경험이 그다지 많지 않기 때문에, 본 현장에서는 철저한 설계 및 시공관리가 이루어졌다. FHWA 설계기준에 근거하여 본 현장 보강토옹벽의 내적 및 외적안정을 검토하였고, Bishop의 간편법을 이용하여 전반활동에 대한 안정성 해석을 수행하였다. 또한 시공관리 및 안정성 검토를 위한 일련의 현장계측을 수행하였다. 본 논문에서는 높이가 20m 이상이고, 2단으로 시공된 대표단면 2개소에 대한 계측결과를 분석하였다. 계측결과, 벽체 및 보강재의 변형이 매우 작게 측정되었으며, 벽체작용 수평토압 또한 미소한 것으로 나타났다. 따라서 높이가 20m이상으로 매우 높은 옹벽구조물에 있어서, 보강토옹벽공법이 성공적으로 적용될 수 있음을 확인하였고, 또한 시공관리가 잘 이루어질 경우 이같이 높은 보강토옹벽에 대하여 FHWA 설계기준이 매우 보수적인 안전측 결과를 보임을 알 수 있었다.

Keywords