• Title/Summary/Keyword: External Resistance

Search Result 614, Processing Time 0.027 seconds

Effect of an External AC Magnetic field on Dynamic Resistance and Loss Characteristic in a Bi-2223 Tape (외부 교류자장이 Bi-2223테이프의 동저항 및 손실특성에 미치는 영향)

  • Ryu, Kyung-Woo;Choi, Byoung-Ju
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.473-477
    • /
    • 2005
  • A Bi-2223 tape has been developed for power applications such as a fault current limiter, a power cable and a superconducting magnetic energy storage system. In such applications, the Bi-2223 tape carries time varying transport current and in addition experiences time varying external magnetic field. It is well known that the external magnetic field not only causes magnetization loss in the Bi-2223 tape, but also drastically increases transport loss due to a so-called 'dynamic resistance' We developed an evaluation setup, which can measure transport loss in external at magnetic fields. Using this equipment, we measured the dynamic resistances for various amplitudes and frequencies of an external at magnetic field perpendicular to the face in the tape. Simultaneously we investigated the effect of an external ac field on transport loss with different experimental conditions. This paper describes test results ana discussions on correlation between the dynamic resistance and the transport loss for the Bi-2223 tape.

Systems to prevent the load resistance loss of pallet racks exposed to cyclic external force

  • Heo, Gwanghee;Kim, Chunggil;Baek, Eunrim;Jeon, Seunggon
    • Structural Engineering and Mechanics
    • /
    • v.83 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • This study aims to determine the cause of the load resistance loss in storage racks that can be attributed to external forces such as earthquakes and to improve safety by developing reinforcement systems that can prevent load resistance loss. To this end, a static cyclic loading test was performed on pallet racks commonly used in logistics warehouses. The test results indicated that a pallet rack exposed to an external force loses more than 50% of its load resistance owing to the damage caused to column-beam joints. Three reinforcement systems were developed for preventing load resistance loss in storage racks exposed to an external force and for performing differentiated target functions: column reinforcement device, seismic damper, and viscoelastic damper. Shake table testing was performed to evaluate the earthquake response and verify the performance of these reinforcement systems. The results confirmed that, the maximum displacement, which causes the loss of load resistance and the permanent deformation of racks under external force, is reduced using the developed reinforcement devices. Thus, the appropriate selection of the developed reinforcement devices by users can help secure the safety of the storage racks.

A study on the effect of the external electric type corrosion resistance for the bolt connection in weathering steel box girders. (무도장 내후성 강교량의 Box Girder 내부볼트 연결부에 대한 외부전원식 정기방식효과에 관한 연구)

  • Park Yong-Gul;Kim Hun-Tae;Baek Chan Ho;Choi Jung Youl
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.988-993
    • /
    • 2004
  • This paper considers corrosion problems in the bolt connection of weathering steel box girder bridge using the external electric type corrosion resistance method which resisted to local corrosion in coated steel surface with contacted air. The weathering steel was created a rust itself in the passive state. but a coated box girder type was easily dew form could be made galvanic cell that accelerated corrosion. so that it was ruled by protection coat with some paint. Therefore, it needed that can be applied the external electric type corrosion resistance method in coated surface. As a result of the test of polarization amount had measured that the weathering steel was higher currents than the general steel by about $5\~10\%$. Therefore. an external electric type corrosion resistance method can be used to protect local corrosion in the coated bolt connection of weathering steel box girders effectively.

  • PDF

The Study on Vigor and External Factors of Tree in Damaged Pine Stands by Thecodiplosis japonensis Uchida et Inouye (솔잎혹파리 피해임지내 수목의 외형적 인자와 관련한 수세변동과정 해석)

  • Lee, Chan-Yong;Kim, Joung-Kuk;Chae, Hee-Mun;Lee, Sang-Bae;Won, Dae-Sung
    • Journal of Forest and Environmental Science
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This paper investigated external factors (height. crown width. diameter breath height, clear length) of tree and electric resistance ($k{\Omega}$) in damaged forest by Thecodiplosis japonensis Uchida et Inouye. The height. crown width and diameter breath height of tree external factors have high a coefficient of correlation. but clear length has not a coefficient of correlation. In relationship of electric resistance and external factor. big tree that height. crown width. diameter breath height has lower electric resistance value than that of small tree. (low electric resistance value is high tree vigor, high electric resistance value is low tree vigor)) Dead tree have smaller diameter breath height. crown width. higher clear length than survival tree in damaged forest by Thecodiplosis japonensis Uchida et Inouye. To investigation of relationship external factors according to electric resistance value. electric resistance value was divided three class (< $l4k{\Omega}$, possible of survival. $14{\sim}20k{\Omega}$, > $20k{\Omega}$, possible of dead). In lower class(< $l4k{\Omega}$), external factors have bigger which was height. crown width. diameter breath height and lower which was clear length than them of higher class ($14{\sim}20k{\Omega}$, > $20k{\Omega}$). Linear regression solutions of electric resistance and external factors were Y = -0.572 ${\times}$ Height - 1.163 ${\times}$ crown width - 0.242 ${\times}$ diameter breath height + 0.757 ${\times}$ clear length + 25.765. Regression solutions were significant in 5%.

  • PDF

Transport Loss Characteristics of a Bi-2223 Tape in External AC Magnetic Fields (외부 교류지장에 대한 Bi-2223테이프의 통전손실 특성)

  • Ryu, Kyung-Woo;Kim, Chang-Wan;Cha, Guee-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.6
    • /
    • pp.290-295
    • /
    • 2001
  • The transport loss of a Bi-2223 tape exposed to external magnetic fields was investigated. The results show that the transport loss is independent on voltage lead arrangements in case the magnetization loss is compensated. A serous increase of the transport loss due to external AC magnetic field is observed. The loss is described well by dynamic resistance loss in relatively high fields, but another mechanism than the dynamic resistance must be responsible for the increase of the loss in low fields. The transport loss is also dependent strongly on the orientation of the external fields.

  • PDF

Dynamic Resistance Characteristics of a Technical High-Tc Superconductor (실용 고온초전도체의 동저항 특성)

  • Ryu, K.;Choi, B.J.;Kim, H.J.;Seong, K.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1225-1227
    • /
    • 2005
  • A Bi-2223 tape has beer developed for power applications such as a fault current limiter, a power cable and a superconducting magnetic energy storage system. In such applications, the Bi-2223 tape carries time varying transport current and in addition experiences time varying external magnetic field. It is well known that the external magnetic field not only causes magnetization loss in the Bi-2223 tape, but also drastically increases transport loss due to a so-called "dynamic resistance". We developed an evaluation setup, which can measure transport loss in external at magnetic fields. Using this equipment, we measured the dynamic resistances for various amplitudes and frequencies of an external ac magnetic field perpendicular to the face in the tape. Simultaneously we investigated the effect of an external ac field on transport loss with different experimental conditions. This paper describes test results and discussions on correlation between the dynamic resistance and the transport loss for the Bi-2223 tape.

  • PDF

Effect of External Resistance on Electrical Properties of Two-Chamber type Microbial Fuel Cells (이형반응기 미생물연료전지의 전기적 특성에 미치는 외부저항의 영향)

  • Lee, Myoung-Eun;Jo, Se-Yeon;Chung, Jae-Woo;Song, Young-Chae;Woo, Jung-Hui;Yoo, Kyu-Seon;Lee, Chae-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.167-173
    • /
    • 2011
  • The Effects of external resistance on electrical properties such as current density, power density and coulombic efficiency were investigated in two-chamber type MFCs using a ferricyanide as reducing agent. A stable electricity was produced when a constant time elapsed after innoculation of mixed cultures into the anode compartment; voltages from 0.13 to 0.16 V was measured at $50{\Omega}$ of external resistance. When the external resistance was increased, the current density decreased and the power density rapidly increased and then slowly decreased. Big variation of electrical properties was observed in high-current density region due to the concentration loss related with substrate consumption in repeated experiments changing the external resistance. The maximum power density ($175.8mW/m^2$) and coulombic efficiency (46.1%) were obtained at $100{\Omega}$ of the external resistance which is nearest with the internal resistance ($134{\Omega}$) of MFC system.

Protection Resistance Determination for Field Winding in Superconducting Generator (초전도발전기의 계자권선 보호저항 선정에 관한 연구)

  • Kang, Joon-Sun;Nah, Wan-Soo;Kwon, Young-Kil;Sohn, Myoung-Hwan;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.238-240
    • /
    • 1999
  • In this paper, the protection resistance determination for the field winding in superconducting generator is suggested. To protect the field winding in a generator, they usually use the external resistance to decrease the field current more rapidly when quench occurs in the winding. Since the field winding is actually separated into four sections (magnets), we have choices to insert 1, 2, and 4 external resistances. For each case, the current decay and the voltages across e winding are calculated, and we can choose the best external resistance.

  • PDF

Effects of Different External Loads on the Activities of the Gluteus Maximus and Biceps Femoris during Prone Hip Extension in Healthy Young Men

  • Bae, Chang-Hwan;Choe, Yu-Won;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 2020
  • PURPOSE: This study examined the effects of different external loads on the muscle activities around the hip during prone hip extension with knee flexion (PHEKF) exercise in healthy young men. METHODS: Sixteen healthy adult males participated in the study. A pressure biofeedback unit was used to provide feedback to the participants during the abdominal drawing-in maneuver (ADIM) with PHEKF. Sandbags (0 kg, 1 kg, 2 kg, and 3 kg) were used to provide external resistance. The quadriceps was contracted to maintain knee flexion 90° against resistance. Each resistance condition using a sandbag weight was given in random order. Surface electromyography (sEMG) was used to measure the electrical activity of the gluteus maximus, biceps femoris, and erector spinae during PHEKF. RESULTS: The muscle activity of the gluteus maximus was highest with the 3 kg resistance and lowest with 0 kg (F = 128.46, P = .00). The muscle activities of the biceps femoris and erector spinae were highest with 0 kg and lowest with 3 kg (F = 29.49, P = .00). The muscle activity rate of the gluteus maximus/biceps femoris was highest with 3 kg and lowest with 0 kg (F = 37.49, P = .00). CONCLUSION: The activity of the gluteus maximus was increased using a higher external weight load during PHEKF, while the activity of the biceps femoris decreased. These findings suggest that an external weight is needed during hip extensor exercise to strengthen the gluteus maximus and inhibit the biceps femoris.

A Study on an External Thermal Resistance Equation of Underground Tunnel in Korea (우리나라 실정에 맞는 전력구에 대한 외부열저항 계산식에 관한 연구)

  • Jeong, S.H.;Kim, D.K.;Choi, S.B.;Bae, J.H.;Ha, T.H.;Lee, H.G.;Gwag, B.M.;Yoon, H.H.;Kang, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.162-164
    • /
    • 2000
  • This paper compares some calculation equations of the external thermal resistance in underground tunnel. As result, this paper suggests the external thermal resistance equation suitable for Korea's underground tunnel.

  • PDF