• Title/Summary/Keyword: External Quality

Search Result 1,325, Processing Time 0.029 seconds

Survey on the vibration transfer characteristics of the human body vibration models (인체 진동모델의 진동 전달 특성에 관한 조사)

  • 우춘규;정완섭;김수현;곽윤근
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.29-33
    • /
    • 1996
  • This paper addresses a systematic way of understanding the transfer characteristics of whole-body vibration due to the external excitation. Amirouche's and Tamaoki's models are considered, whose analysis shows a new result that resonant frequencies related to the head vibration are well coincided with those of the body. This point reveals that the improvement of the ride quality of passenger cars can be achieved by isolating only external vibration components transfered to the body. Finally, this paper points out the limitation of previous whole-body vibration models, which gives the motivations of setting up more 'practical and generalized' whole-body vibration models of interests in this study.

  • PDF

Survey on the Vibration Transfer Characteristics of thw Whole-Body Vibration Models (인체 진동모델의 진동 전달특성에 관한 조사)

  • 우춘규;정완섭;김수현;곽윤근
    • Journal of KSNVE
    • /
    • v.6 no.5
    • /
    • pp.625-633
    • /
    • 1996
  • This paper addresses a systematic way of understanding the transfer characteristics of whole-body vibration due to the external excitation. Amirouche's and Tamaoki's models are considered, whose analysis shows a new result that resonant frequencies related to the head vibration are well coincided with those of the body. This point reveals that the improvement of the ride quality of passenger cars can be achieved by isolating only external vibration components transfered to the body. Finally, this paper points out the limitation of previous whole-body vibration models, which gives the motivations of setting up more 'practical and generalized' whole-body vibration models of interest in this study.

  • PDF

Phophorus External Gettering for High Quality Wafer of Silicon Heterojunction Solar Cells

  • Park, Hyo-Min;Tak, Seong-Ju;Kim, Chan-Seok;Park, Seong-Eun;Kim, Yeong-Do;Kim, Dong-Hwan
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.43.2-43.2
    • /
    • 2011
  • Minority Carrier recombination should be suppressed for high efficiency solar cells. However, impurities in the silicon bulk region deteriorate the minority carrier lifetimes, causes conversion efficiency drop. In this study, we introduced phosphorus external gettering for silicon heterojunction solar cell substrates. Gettering was undergone at 750, 800, 850 and $900^{\circ}C$ in furnace for 30 minutes. Bulk lifetimes and calculated diffusion length were improved. We applied phosphorus gettering to silicon heterojunction solar cells. Gettered group and ungettered group were used as substrate of silicon heterojunction solar cells. After fabrication, characteristics of solar cells were analyzed. The results were observed to see the enhancement of substrate quality which directly connects with solar cell properties.

  • PDF

A new research program that aims to establish an external audit system to radiotherapy QA in Japan

  • Shimbo, Munefumi;Tabushi, Katsuyoshi;Endo, Masahiro;Ikeda, Hiroshi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.17-18
    • /
    • 2002
  • Last year, a three-year research program was started in order to establish an external audit system to radiotherapy QA in Japan. It consists of questionnaire surveys, mailed (off-site) dosimetry and visited (on-site) dosimetry at radiotherapy facilities in Japan. The first questionnaire was sent to all Japanese radiotherapy facilities in October 2001, surveying basic QA procedures at each facility. 628 answers were returned with the return rate of 87%. In February 2002, the second questionnaire was sent. Off-site and on-site dosimetry have been tested in several facilities, and will be started soon. We anticipates that this program will gradually grow to a radiotherapy quality control center similar to Radiological Physics Center at MD Anderson Hospital.

  • PDF

Design of Semi-Active suspension system for Railway Vehicle with narrow gauge (협궤 차량용 준능동형 현가 시스템 설계)

  • Lee Nam-Jin;Kim Chul-Gun;Nam Hak-Gi
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.473-478
    • /
    • 2005
  • Active suspension system improves ride quality with optimized suspension force, generated by electric, hydrolic or pneumatic power and controlled by micro-processor under various operation condition of train, while Semi-Active susepsion system provides optimized and controlled characteristics of suspensions such as damping coefficient without external energy. The benefits fo Semi-Active suspension are no required power source and to be made compact with lower cost. Train with narrow gauge could be more unstable than one for normal or wide gauge, and it could be more vibrated than others one by external force such as aerodynamic force and track irregularity. So, the reduced ride quality could be improved with appling with Semi-active suspension system. In this report, the Semi-Active suspension system for narrow gauge train shall be proposed and to prepare the Roller Rig test of this train, integration of system, development of control algorithm and confirmation of its performance with simulation tool would be taken.

  • PDF

Effectiveness of external agents in polluted sedimentary area

  • Alam, Md. Mahabub;Haque, Md. Niamul;Cho, Daechul;Kwon, Sung-Hyun
    • Environmental Engineering Research
    • /
    • v.21 no.1
    • /
    • pp.52-57
    • /
    • 2016
  • Sediment is a useful natural source but deteriorated continually by anthropogenic and industrial sources. Therefore, it is imperative to search a suitable method for improving or restoring sediment quality. Sediment has been tested to identify the effects of some external agents on a polluted area for 28 days. Chemical analysis and total viable counts (TVC) test have been conducted for 4 days interval to assess their performance. The analyses of chemical oxygen demand (COD), acid volatile sulfide (AVS), total phosphorous (T-P), total nitrogen (T-N) indicate that the chemical agents was more efficient to improve sediment quality whereas the microbial agent was more efficient for nutrient releasing from sediment. Oxygen releasing property of the chemical agent was thought to be providing with more congenial environment for the higher growth of the bacterial community than the direct application of microbial agents.

Performance of Microbial Fuel Cell Integrated with Anaerobic Membrane Filter for Continuous Sewage Treatment with Stable Effluent Quality (안정적 유출수질의 연속 하수처리를 위한 혐기성 멤브레인 필터와 통합된 미생물연료전지의 성능 평가)

  • Lee, Yunhee;Oa, Seong-Wook
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.808-812
    • /
    • 2013
  • A new type of microbial fuel cell (MFC) with anaerobic membrane filter was designed to produce bioelectricity and to treat domestic sewage at relatively high organic loading rate (OLR) of $6.25kgCOD/m^3/day$ and short hydraulic retention time (HRT) of 1.9 h. A following aeration system was applied to ensure effluent water quality in continuous operation. Glucose was supplemented to increase the influent concentration of domestic sewage. Influent substrate of 95% was removed via the MFC and following aeration system and the corresponding maximum power density was $25.6mW/m^3$. External resistor of $200{\Omega}$ and air-cathode system contributed better MFC performance comparing to $2000{\Omega}$ and dissolved oxygen as a catholyte.

Design of Multipurpose Phantom for External Audit on Radiotherapy

  • Lim, Sangwook
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.122-129
    • /
    • 2021
  • Purpose: This study aimed to design a multipurpose dose verification phantom for external audits to secure safe and optimal radiation therapy. Methods: In this study, we used International Atomic Energy Agency (IAEA) LiF powder thermoluminescence dosimeter (TLD), which is generally used in the therapeutic radiation dose assurance project. The newly designed multipurpose phantom (MPP) consists of a container filled with water, a TLD holder, and two water-pressing covers. The size of the phantom was designed to be sufficient (30×30×30 cm3). The water container was filled with water and pressed with the cover for normal incidence to be fixed. The surface of the MPP was devised to maintain the same distance from the source at all times, even in the case of oblique incidence regardless of the water level. The MPP was irradiated with 6, 10, and 15 MV photon beams from Varian Linear Accelerator and measured by a 1.25 cm3 ionization chamber to get the correction factors. Monte Carlo (MC) simulation was also used to compare the measurements. Results: The result obtained by MC had a relatively high uncertainty of 1% at the dosimetry point, but it showed a correction factor value of 1.3% at the 5 cm point. The energy dependence was large at 6 MV and small at 15 MV. Various dosimetric parameters for external audits can be performed within an hour. Conclusions: The results allow an objective comparison of the quality assurance (QA) of individual hospitals. Therefore, this can be employed for external audits or QA systems in radiation therapy institutions.

Decision on Quality Investment Level Under Moral Hazard Environment

  • Zhang, Cui-Hua;Yu, Hai-Bin
    • International Journal of Quality Innovation
    • /
    • v.8 no.2
    • /
    • pp.20-31
    • /
    • 2007
  • Moral hazard and adverse selection often exist in asymmetric information environment. In this paper, quality investment decision problem is studied under moral hazard. A basic model for quality investment level decision is developed with the supplier as a principal and the buyer as an agent. And then we regard the supplier and the buyer's rational limitations to set up a model when the buyer's quality evaluation and processing activities are hidden. The model is optimized and the results under different backgrounds are discussed and compared. Results show that the buyer's quality evaluation level and processing level are mostly influenced by the supplier's quality assurance payment. Both the supplier and the buyer choose different quality investment levels under moral hazard because of the supplier's payment to the buyer in case of internal failure and external failure.

Development of Organization-level Evaluation Model and Process for Information Systems Quality (조직 수준의 정보시스템 품질평가 모형과 절차 개발)

  • Lee, Sang-Ho;Cho, Sung-Rim;Ahn, Byung-Oh
    • Journal of Information Technology Services
    • /
    • v.7 no.4
    • /
    • pp.151-165
    • /
    • 2008
  • This study suggests the organization-level standard(model and process) for quality evaluation of information systems(IS) in non-use organizations despite international standards(ISO/IEC 9126 and ISO/IEC 14598) and national standards(KS X 9126 and KS X 14598) related to quality evaluation of IS. The standard in this study is composed of quality evaluation processes, a quality model, and quality metrics. The weights of the attributes and the sub-attributes in the quality model were calculated by an analytic hierarchy process(AHP). The minimum level and the target level of each metrics were determined by brainstorming of the committee. Furthermore, the case study for the investigation of the applicability and the usability of the suggested organizational standard in the real IS development project was performed. For gaining significant benefits of the standard, both the diffusion and the experience accumulation by its continuous use are needed.