• 제목/요약/키워드: External Loading Type

검색결과 106건 처리시간 0.027초

Effect of cyclic loading and retightening on reverse torque value in external and internal implants

  • Cho, Woong-Rae;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.288-293
    • /
    • 2015
  • PURPOSE. The aim of this study was to evaluate the effect of cyclic loading and screw retightening on reverse torque value (RTV) in external and internal type implants. MATERIALS AND METHODS. Cement-retained abutments were connected with 30 Ncm torque to external and internal type implants. Experimental groups were classified according to implant connection type and retightening/loading protocol. In groups with no retightening, RTV was evaluated after cyclic loading for 100,000 cycles. In groups with retightening, RTV was measured after 3, 10, 100 cycles as well as every 20,000 cycles until 100,000 cycles of loading. RESULTS. Every group showed decreased RTV after cyclic loading. Before and after cyclic loading, external type implants had significantly higher RTVs than internal type implants. In external type implants, retightening did not affect the decrease in RTV. In contrast, retightening 5 times and retightening after 10 cycles of dynamic loading was effective for maintaining RTV in internal type implants. CONCLUSION. Retightening of screws is more effective in internal type implants than external type implants. Retightening of screws is recommended in the early stage of functional loading.

THE ASSESSMENT OF ABUTMENT SCREW STABILITY BETWEEN THE EXTERNAL AND INTERNAL HEXAGONAL JOINT UNDER CYCLIC LOADING

  • Lee, Tae-Sik;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jae-Bong;Kim, Sung-Hun
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.561-568
    • /
    • 2008
  • STATEMENT OF PROBLEM: Currently, many implant systems are developed and divided into two types according to their joint connection: external or internal connection. Regardless of the connection type, screw loosening is the biggest problem in implant-supported restoration. PURPOSE: The purpose of this study is to assess the difference in stability of abutment screws between the external and internal hexagonal connection types under cyclic loading. MATERIAL AND METHODS: Each of the 15 samples of external implants and internal abutments were tightened to 30 N/cm with a digital torque gauge, and cemented with a hemispherical metal cap. Each unit was then mounted in a $30^{\circ}$ inclined jig. Then each group was divided into 2 sub-groups based on different periods of cyclic loading with the loading machine (30 N/ cm - 300 N/cm,14 Hz: first group $1{\times}10^6$, $5{\times}10^6$ cyclic loading; second group $3{\times}10^6$, $3{\times}10^6$ for a total cyclic loading of $6{\times}10^6$) The removal torque value of the screw before and after cyclic loading was checked. SPSS statistical software for Windows was used for statistical analysis. Group means were calculated and compared by ANOVA, independent t-test, and paired t-test with ${\alpha}$=0.05. RESULTS: In the external hexagonal connection, the difference between the removal torque value of the abutment screw before loading, the value after $1{\tims}10^6$ cyclic loading, and the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was not significant. The difference between the removal torque value after $3{\times}10^6$ cyclic loading and after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. In the internal hexagonal connection, the difference between the removal torque value before loading and the value after $1{\times}10^6$ cyclic loading was not significant, but the value after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading was reduced and the difference was significant (P < .05). In addition, in the internal hexagonal connection, the difference between the removal torque value after $3{\times}10^6$ cyclic loading and the value after $3{\times}10^6$, and additional $3{\times}10^6$ cyclic loading was not significant. CONCLUSION: The external hexagonal connection was more stable than the internal hexagonal connection after $1{\times}10^6$, and additional $5{\times}10^6$ cyclic loading (t = 10.834, P < .001). There was no significant difference between the two systems after $3{\times}10^6$, and additional $3{\times}10^6$ cycles.

고무차륜형식 경전철(AGT) 대차의 구조해석 및 주파수 응답해석 (The Structural and Frequency Response Analysis for the Bogie of the Rubber Wheel-type AGT)

  • 변상윤;유형선;윤성호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.558-565
    • /
    • 1999
  • Rubber wheel-type AGT has two major kinds of bogie; one is the bogie type and the other and passenger loads. This paper deals with the statics analysis for two types of bogie frame subjected to combined external forces, as well as independent ones specified in UIC 515-4. Furthermore, the dynamics analysis is performed under vibrational loading conditions so as to compare dynamic characteristics, Numerical results by using commercial packages, Ⅰ-DEAS and NASTRAN show that maximum stresses do not exceed the yielding level of material used for both bogies. From an overall viewpoint of strength, the bogie type turns out to be superior to the steering type except the case of a lateral loading. It is also observed that the steering type shows a be stiffened. It is strongly anticipated that vibrational fatigue analysis should be carried out under realistic loading conditions closely matching to situations such as running surface and lateral clearances along the guideway.

  • PDF

이축압축 조건에서 실험체/재하판 경계면상의 마찰저항 감소를 위한 롤러 지지된 피스톤 형태의 하중재하판의 개발 (Development of a roller supported piston type loading platen reducing the frictional restraint along the interfaces between the specimen and platens under the biaxial loading condition)

  • 사공명;김세철;이준석;박두희
    • 한국터널지하공간학회 논문집
    • /
    • 제10권3호
    • /
    • pp.303-312
    • /
    • 2008
  • 암석의 물성평가 및 파괴모델 실험을 위하여 다축압축 실험이 자주 사용된다. 다축압축 실험을 통한 암반의 거동 평가시 정확한 결과의 산출을 위하여 실험체와 가압판 경계면에서의 경계조건에 대한주의를 기울일 필요가 있다. 일반적으로 철제로 된 일체형 가압판의 사용시 실험체의 경계면과 하중재하판사이에서 발생하는 마찰저항으로 인하여 실험체 경계부에서부터 응력회전 현상이 발생하여 경계면에서부터 작용하는 외력의 방향은 회전하게 된다. 이와 같은 실험체/하중재하판 경계면 사이에서 발생하는 마찰저항을 감소시키기 위하여 다양한 방법이 제시되었다. 그 중 대표적인 예가 빗살구조의 하중재하판이다. 본 논문에서는 빗살구조의 하중재하판의 단점을 극복하고 하중재하판의 공간이 상대적으로 덜 차지하는 롤러로 지지된 피스톤 형태의 하중재하판을 소개하고 있다. 롤러로 지지된 피스톤 형태의 하중재하판은 지지강성이 충분한 짧은 피스톤 후면에 샤프트 형태의 롤러를 설치하여 실험체의 변형과 동시에 각 피스톤이 동반하여 거동하도록 구성되었다. 본 논문에서는 롤러 지지된 피스톤의 구조 상세 및 요구되는 기능에 대한 검증을 위하여 측면부 마찰저항 실험과 이축압축 실험이 수행되었으며 실험결과와 수치해석 결과의 비교를 통하여 장비의 적용성에 대한 검증이 이루어 졌다.

  • PDF

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

보라매 전투기 전자광학타겟팅 장비 탑재형태의 분석 평가 (An Evaluating Analysis of Installing Type of EOTS for The Boramae Fighter)

  • 강치행;오승현;강희창;천호정;이범석
    • 한국항공우주학회지
    • /
    • 제40권10호
    • /
    • pp.910-915
    • /
    • 2012
  • 본 논문에서는 탐색개발중인 전투기에 탑재할 EOTS의 운용유지 소요기술 개발비용에 대한 기술적 특성을 평가 분석하여 탑재방식을 연구하였다. 15개 항의 운용성 측면의 평가 결과, 내장형은 스텔스 기능의 장점이 있으며, 외장형은 장 탈착성, 접근성, 현 운용 항공기와의 호환 활용성 및 무장 교체 가능성 등의 장점이 있다고 평가되었다. 17개 항의 기술 및 개발 비용 평가 결과, 소형 경량화 및 소모 전력에서는 내장형 탑재 방식이 유리하지만, 국내 기술의 적용에 의한 비용 절감과 성능 달성을 위한 기술 안정성 측면에서는 외장형 탑재방식이 우수하다고 평가되었다.

임플랜트 고정체의 형태와 연결방식에 따른 임플랜트 및 지지조직의 응력분포 (STRESS ANALYSIS OF SUPPORTING TISSUES AND IMPLANTS ACCORDING TO IMPLANT FIXTURE SHAPES AND IMPLANT-ABUTMENT CONNECTIONS)

  • 한상운;박하옥;양홍서
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.226-237
    • /
    • 2004
  • Purpose: Four finite element models were constructed in the mandible having a single implant fixture connected to the first premolar-shaped superstructure, in order to evaluate how the shape of the fixture and the implant-abutment connection would influence the stress level of the supporting tissues fixtures, and prosthethic components. Material and methods : The superstructures were constructed using UCLA type abutment, ADA type III gold alloy was used to fabricate a crown and then connected to the fixture with an abutment screw. The models BRA, END , FRI, ITI were constructed from the mandible implanted with Branemark, Endopore, Frialit-2, I.T.I. systems respectively. In each model, 150 N of vertical load was placed on the central pit of an occlusal plane and 150 N of $40^{\circ}$ oblique load was placed on the buccal cusp. The displacement and stress distribution in the supporting tissues and the other components were analysed using a 2-dimensional finite element analysis . The maximum stress in each reference area was compared. Results : 1. Under $40^{\circ}$ oblique loading, the maximum stress was larger in the implant, superstructure and supporting tissue, compared to the stress pattern under vertical loading. 2. In the implant, prosthesis and supporting tissue, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 3. In the superstructure and implant/abutment interface, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 4. In the implant fixture, the maximum stress was smaller with the internal connection type (FRI) and the morse taper type (ITI) when compared to that of the external connection type (BRA & END). 5 The stress was more evenly distributed in the bone/implant interface through the FRI of trapezoidal step design. Especially Under $40^{\circ}$ oblique loading, The maximum stress was smallest in the bone/implant interface. 6. In the implant and superstructure and supporting tissue, the maximum stress occured at the crown loading point through the ITI. Conclusion: The stress distribution of the supporting tissue was affected by shape of a fixture and implant-abutment connection. The magnitude of maximum stress was reduced with the internal connection type (FRI) and the morse taper type (ITI) in the implant, prosthesis and supporting tissue. Trapezoidal step design of FRI showed evenly distributed the stress at the bone/implant interface.

고무차륜형 AGT 주행장치의 진동피로해석 (Vibration Fatigue for the Bogie frame of the Rubber Wheel AGT)

  • 유형선;윤성호;변상윤;편수범
    • 한국철도학회논문집
    • /
    • 제3권3호
    • /
    • pp.117-124
    • /
    • 2000
  • The rubber wheel-type AGT has two major kinds of bogie; one is the bogie type and the other steering one. Both are important vehicular structure to support the whole running vehicle and passenger loads. This paper deals with the static analysis for the two types of bogie frame subjected to combined external forces, as well as independent ones specified in UIC 515-4. Furthermore, the dynamic analysis is performed under vibrational loading conditions so as to compare dynamic characteristics, Numerical results by using commercial packages, I-DEAS and NASTRAN show that maximum stresses do not exceed the yield strength level of material used for both bogies. From an overall viewpoint of strength, the bogie type turns out to be superior to the steering type except for the case of a lateral loading. It is also observed that the steering type shows a characteristics of low frequency behavior during a course of searching for structurally weak areas to be stiffened. The vibrational fatigue analysis for each bogie frame depends on the loading time history conditions which is applied. Time History Central Database List in the NASTRAN package. Subsequent1y, the fatigue life of bogie type is longer than the steering type.

  • PDF

반복하중을 받는 외부 보-기둥 접합부에 정착된 57mm 확대머리철근의 정착성능평가 (Evaluation on Anchorage Performance of 57mm Headed Bars in Exterior Beam-Column Joint under Cyclic Loading)

  • 정형석;정주홍;최창식;배백일;최현기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.68-75
    • /
    • 2021
  • 본 연구에서는 반복하중을 받는 외부 보-기둥 접합부에 정착된 57mm 확대머리철근의 정착성능을 평가하였다. 총 4개의 외부 보-기둥 접합부 실험체를 계획하였으며, 콘크리트 압축강도, 측면피복두께, 횡보강근비 및 파괴유형을 주요 실험 변수로 설정하여 정착성능평가를 수행하였다. 성능평가 결과, 접합부에 정착된 대구경 확대머리철근의 정착성능에 가장 큰 영향을 주는 요소는 측면피복두께 및 횡보강근으로 나타났으며, 외부 보-기둥 접합부에 정착된 57mm 대구경 확대머리철근은 반복하중하에서도 충분한 정착성능이 발현되는 것을 확인할 수 있었다.

Study of screw loosening in cementation type implant abutment

  • Hwang, Bo-Yeon;Kim, Yung-Soo;Kim, Chang-Whe
    • 대한치과보철학회지
    • /
    • 제38권6호
    • /
    • pp.765-781
    • /
    • 2000
  • The purpose of this study was to compare the screw loosening characteristics of three avail-able cementation type abutments: one-piece cementation type abutment; two-piece cementation type abutment using titanium abutment screw; two-piece cementation type abutment using gold abutment screw. Two implant supported three-unit superstructures were fabricated using a pair of 3 kinds of abutments for each experimental model. Cyclic loading was applied on the specimen, and made to stop when the superstructure showed movement over threshold range. The loaded cycle was counted until the machine stopped. Frequency analysis was done to measure the change of natural frequency before and after the application of cyclic load and to find the effect of screw loosening on the change of natural frequency. The specimen assembly was modeled to perform the finite element analysis to see the distribution of the stress induced by the application of preload over the screw joint and to compare the pattern of the distribution of stress induced by the external force with the change of the preload condition. The following results were obtained: 1. The failure loading cycle of two-piece cementation type abutment using gold screw was significantly greater than those of the other groups. 2. One-piece cementation type abutment applied to multi-unit restoration case did not show greater resistance to screw loosening compared to two-piece cementation type abutments. 3. Frequency analysis showed decrease in natural frequency when screw loosening occured.

  • PDF