• 제목/요약/키워드: External Insulation

검색결과 206건 처리시간 0.032초

지역난방 열배관의 외부작용력 및 되메움재의 안정성 확보에 관한 연구 (The Stability Assessment of Backfill Materials and External Loads in Pre-Insulated District Heating Pipes)

  • 김진만;최봉혁;고현일
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.656-661
    • /
    • 2009
  • In this study, theoretical analysis and evaluation tests were performed to assess the pipe stability against compaction equipments and vehicle loads when conventional construction criteria for pre-insulation heating pipes are applied and the alternative material, crushed sand, are used for backfills. The research outcomes shows that (1) the conventional code criteria for pre-insulated heating pipes is well established to support compaction equipments and vehicle loads, (2) the crushed sands as an alternative is usable as backfill materials for pre-insulated heating pipes based on the suitability evaluations of various types of pipes, and (3) the crushed sand agree well with the design consideration of pre-insulated heating pipes construction in the points of economical efficiency and construction criteria.

  • PDF

GIS의 도파관 특성을 고려한 절연결함 위치판정에 관한 연구 (A Study for the Fault Location of Insulation Defects considering Waveguide Characteristics in GIS)

  • 이승철;정승용;이재호;구자윤
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.252-255
    • /
    • 2008
  • A study for discharge pattern analysis partial and fault location by use of UHF sensors in GIS. However, in the latter case, the results considered the velocity of EM waves modified by the waveguide characteristics of GIS bus bar were not reported yet. In this paper, UHF wide band sensor to detect partial discharge signals have been designed and manufactured to get the widest band characteristic by an application of Fat-Dipole UHF antenna and the result that the transmission velocity of EM waves is 2/3 of the light have been got through the consideration of waveguide characteristics. Also, to verify applicability on site of the developed method, self-designed external type UHF sensor have been installed on operating GIS in Korea Midland Power co. and detected location of the fault. Through the fault have been found at the location, the reliability of the developed method have been proved.

진공인터럽터 내부 shield gap에 따른 전계분포해석 (Electric field distribution analysis along shield gap inner vacuum interrupter)

  • 윤재훈;김병철;이승수;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1368-1369
    • /
    • 2008
  • This paper describes the electric field distribution analysis along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield gap. The reason is as it gets distortion of equipotential line done. finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

두개의 전극도자를 사용하게 된 Permanent Transvenous Pacemaker Implantation: 1례 보고 (Permanent Transvenous Endocardial Pacemaker Inevitably Implanted Two Electrode Leads)

  • 곽문섭;이홍균
    • Journal of Chest Surgery
    • /
    • 제14권2호
    • /
    • pp.168-174
    • /
    • 1981
  • Since cardiac pacemaker was first totally implanted by Chardack, Gage and Greatbatch [1966], the electrical circuity of the cardiac pacemaker has been improved, modified, and refined. The problem of transvenous electrodes, however, is still remained; this may be due to electrode displacement, exit and/or entrance block, lead fracture and insulation defects. In permanent cardiac pacing, Irreversible loss of function of the transvenous electrode catheter eventually requires insertion of new lead. Authors now report one case that disclosed easy displacement of electrode tip in early phase of implantation and then two years and five months later, malfunctioning electrode could not be withdrawn from the cardiovascular system because it has become firmly enclosed by fibrous tissue along its course from the vein tract to the right ventricle. Under such circumstances, the electrode catheter tip was left in tricuspid annulus after being sutured at its entrance and burying the loop of lead in generator pocket. New other one electrode was then reimplantation through left external jugular vein.

  • PDF

공동주택에 적용 가능한 건식 외벽시스템 시공에 따른 단열성능 검토 (Thermal Performance of Developed Cladding Systems on Multi-Family Residential Buildings)

  • 홍구표;강지연;김형근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.267-268
    • /
    • 2018
  • The purpose of this study was to analyze the thermal performance of a cladding system which developed for easy maintenance and flexibility and installed on a long-life housing. The developed cladding systems were finished mock-up test at an authorized certification laboratory and were satisfied with the standard of the external wall system. The surface temperature and linear thermal transmittance of the cladding system were investigated by using the THERM as a simulation program. The joining part between the cladding systems had a weakness of condensation resistance. The surface temperature of the joining part was improved by filling and adding insulation.

  • PDF

가연성 외장재를 사용한 건축물의 화재확대방지에 관한 연구 (A Study on Fire Spread Prevention of Building using Combusitible Exterior)

  • 박성하;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.149-150
    • /
    • 2018
  • Recently, a large fire has occurred through a dry bit, which is a flammable exterior material, in Daebong Green Apartment Fire in Uijeongbu in 2015 and Jecheon Sports Center Fire in 2017. In this study, KS F ISO 5660-1 Cone calorimeter experiment was used to examine the fire risk of dry bit. Also, the performance of the repair and reinforcement materials to prevent fire expansion was examined. As a result, the dry bit is likely to be ignited by internal and external flower gardens, and its combustion rate and calorific value are very high. In addition, the performance of heat resistance such as ALC panel and ceramic board as a repair and reinforcement material has been proved. However, the insulation is expected to require further consideration.

  • PDF

단순화된 Mark III 방열판의 구조 강도 평가에 관한 연구 (Structural Strength Assessment of Simplified Mark III CS Plate)

  • 정한구;양영순
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.539-543
    • /
    • 2011
  • LNG cargo containment system (CCS) has the primary function of ensuring adequate thermal insulation with keeping natural gas below its boiling point. From the viewpoint of structural design, this LNG CCS can be treated as a laminated composite structure showing complex structural responses under the sloshing load which can be defined as a violent behavior of the liquid contents in cargo tanks due to external forced motions. As LNG CCS type, Mark III containment system from TGZ is considered in this paper and then its structural strength assessment is performed based on a simple higher-order shear deformation theory and maximum stress, maximum strain, Tsai-Wu failure criteria developed for laminated composite plates. The assessment is performed to the initial failure of the Mark III CS plate by investigating failure locations and loads.

  • PDF

Vacuum Interrupter 내부 End_shield가 전계분포에 미치는 영향 (The influence that cup-type shield inner vacuum interrupter causes to electric field distribution)

  • 윤재훈;김병철;허준;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.478-479
    • /
    • 2008
  • this paper describes the electric field distribution interpretation along a shield form inner vacuum interrupter(VI). The equipotential line and electric field and field vector in a VI are analysed by a finite element method at various shield form. in result, The equipotential line and electric field distribution was affected to VI shield form. The reason is as it gets distortion of equipotential line done. shield of cup type is how to electric field distribution, finally, this paper recognized whether or not affected, and proposed gap with the most suitable shield length and an external insulation.

  • PDF

Numerical Modeling of Charge Transport in Polymer Materials Under DC Continuous Electrical Stress

  • Hamed, Boukhari;Fatiha, Rogti
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권3호
    • /
    • pp.107-111
    • /
    • 2015
  • Our work is based on the development of a numerical model to develop a methodology for predicting the aging and breakdown in insulation due to the dynamics of space charge packets. The model of bipolar charge transports is proposed to simulate space charge dynamic for high DC voltage in law-density polyethylene (LDPE), taking into account the trapping and detrapping of recombination phenomena, this model has been developed and experimentally validation. Theoretical formulation of the physical problem is based on the Poisson, the continuity and the transport equations as well as on the appropriate models for injection. Numerical results provide temporal and local distributions of the electric field, the space charge density for the different kinds of charges, conduction and displacement current densities, and the external current.

농촌주택의 봉당·마루 개보수 현황 및 문제점 분석 (A Study on the Current Status and Analysis on the Problem of Unfloored space and Floor Repair in Rural House)

  • 박길범;박준모;김옥규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.117-118
    • /
    • 2014
  • The unfloored space and floor is one of characteristic of traditional house in Korea. This space is used to connecting passage between room or entrance of house. Currently, according to decline of heat insulation property thereby becoming decrepit house, native is repairing it for block external environment such as rain, wind and so on. But, variety problem is happening from wrong repair. This object of this study is current status and analysis on problem of unfloored space and floor repair. As a result, current status of repair is classified repair type, installation position and using form. And position of problem is confirmed connection between original house and extend space.

  • PDF