• Title/Summary/Keyword: External Dose Rate

Search Result 196, Processing Time 0.023 seconds

Evaluation of auto contouring accuracy in 3D planning system (3차원 입체조형치료시 Auto Contouring tool의 유용성 평가)

  • Choi, JM;Ju, SG;Park, JY;Park, YH;Kim, JS
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.35-39
    • /
    • 2002
  • Introduction : It is essential to input patients external contour in 3D treatment plan. We would like to see changes in depth and dose when 3D RTP is operating auto contouring when windows value (Width/Level) differs in this process. Material & Methode : We have analyzed the results with 3D RTP after CT Scanning with round CT Phantom. We have compared and analyzed MU values according to depth changes to Isocenter changing external contour and inputting random Window value. We have watched change values according to dose optimization in 4 directions(LAO, LPO, RAO, RPO), We plan 100 case for exact analyzation. We have results changing window value random to each beam in 100 cans. Result : It showed change between minimum and maximum value in 4 beam is Depth 0.26mm, MU $1.2\%$ in LAO. It showed LPO-Depth 0.13mm, MU $0.9\%$, RAO-Depth 0.2mm MU $0.8\%$, RPO-Depth 0.27mm, MU $1.1\%$ Conclusion : Maximum change in depth 0.27 mm, MU error rate is $0.12\%$ according to Window change. As we can see in these results, it seems Window value change doesn't effect in treatment. However, it seems there needs to select appropriate Window value in precise treatment.

  • PDF

Advanced Biological Treatment of Industrial Wastewater using Food Waste Leachate as an External Carbon Source: Full-Scale Experiment (음식물쓰레기 탈리액을 이용한 산업폐수의 생물학적 고도처리 실증실험)

  • Lee, Byeongcheol;Ahn, Johwan;Lee, Junghun;Bae, Wookeun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.4
    • /
    • pp.461-466
    • /
    • 2011
  • The feasibility of utilizing food waste leachate as an external carbon source was tested to enhance biological nutrient removal from an industrial wastewater with an average flow rate of $164,800m^3/d$ and a low carbon/nitrogen ratio of 2.8. A considerable improvement in the removal of nitrogen and phosphorus was observed when a certain amount of the leachate, ranging from 70 to $142m^3/d$, was supplemented to the biological industrial wastewater treatment process. The addition of the leachate led to an increase in the BOD/N ratio (4.5) and the removal efficiency of nutritents from 29.7% to 71.7% for nitrogen and from 34.8% to 65.6% for phosphorus. However, an excessive dose of the leachate that significantly exceeded $120m^3/d$ caused serious operational problems, like oil-layer formation in the grit chamber and scum layer in the primary clarifier. Thus, an supplement of food waste leachate at a dose acceptable to an existing facilities can be a practical and effective means to enhance the nutrient removal from industrial wastewater and to dispose of the food waste leachate.

A Study on Retrospective of External Radiation Exposure Dose by Optically Stimulated Luminescence of Smart Chip Card (스마트칩 카드을 이용한 광 자극 발광 특성 연구)

  • Park, Sang-Won;Yoo, Se-Jong
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.379-385
    • /
    • 2019
  • Radiation is used for various purposes such as cancer therapy, research of industrial and drugs. However, in case of radiation accidents such as terrorism, collapsing nuclear plant by natural disasters like Fukushima in 2011, very high radiation does expose to human and could lead to death. For this reason, many people are concerning about radiation exposures. Therefore, assessment and research of retrospective radiation dose to human by various path is an necessary task to be continuously developed. Radiation exposure for workers in radiation fields can be generally measured using a personal exposure dosimeter such as TLD, OSLD. However, general people can't be measured radiation doses when they are exposed to radiation. And even if radiation fields workers, when they do not in possession personal dosimeter, they also can't be measured exposure dose immediately. In this study, we conduct retrospective research on reconstruction of dose after exposure by using smart chip card of personal items through Optically Stimulated Luminescence (OSL). The OSL signal of smart chip card shows linear response from 0.06 Gy to 15 Gy and results of fading rate 45 %, 48% for 24 and 48 hours due to the natural emission of radiation in sample, respectively. The minimum detectable limit (MDD) was 0.38 mGy. This values are expected to use as correction values for reconstruction of exposure dose.

Comparative Evaluation of Two-dimensional Radiography and Three Dimensional Computed Tomography Based Dose-volume Parameters for High-dose-rate Intracavitary Brachytherapy of Cervical Cancer: A Prospective Study

  • Madan, Renu;Pathy, Sushmita;Subramani, Vellaiyan;Sharma, Seema;Mohanti, Bidhu Kalyan;Chander, Subhash;Thulkar, Sanjay;Kumar, Lalit;Dadhwal, Vatsla
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.11
    • /
    • pp.4717-4721
    • /
    • 2014
  • Background: Dosimetric comparison of two dimensional (2D) radiography and three-dimensional computed tomography (3D-CT) based dose distributions with high-dose-rate (HDR) intracavitry radiotherapy (ICRT) for carcinoma cervix, in terms of target coverage and doses to bladder and rectum. Materials and Methods: Sixty four sessions of HDR ICRT were performed in 22 patients. External beam radiotherapy to pelvis at a dose of 50 Gray in 27 fractions followed by HDR ICRT, 21 Grays to point A in 3 sessions, one week apart was planned. All patients underwent 2D-orthogonal and 3D-CT simulation for each session. Treatment plans were generated using 2D-orthogonal images and dose prescription was made at point A. 3D plans were generated using 3D-CT images after delineating target volume and organs at risk. Comparative evaluation of 2D and 3D treatment planning was made for each session in terms of target coverage (dose received by 90%, 95% and 100% of the target volume: D90, D95 and D100 respectively) and doses to bladder and rectum: ICRU-38 bladder and rectum point dose in 2D planning and dose to 0.1cc, 1cc, 2cc, 5cc, and 10cc of bladder and rectum in 3D planning. Results: Mean doses received by 100% and 90% of the target volume were $4.24{\pm}0.63$ and $4.9{\pm}0.56$ Gy respectively. Doses received by 0.1cc, 1cc and 2cc volume of bladder were $2.88{\pm}0.72$, $2.5{\pm}0.65$ and $2.2{\pm}0.57$ times more than the ICRU bladder reference point. Similarly, doses received by 0.1cc, 1cc and 2cc of rectum were $1.80{\pm}0.5$, $1.48{\pm}0.41$ and $1.35{\pm}0.37$ times higher than ICRU rectal reference point. Conclusions: Dosimetric comparative evaluation of 2D and 3D CT based treatment planning for the same brachytherapy session demonstrates underestimation of OAR doses and overestimation of target coverage in 2D treatment planning.

The Role of Postoperative External Irradiation for the Incompletely Resected Meningiomas (불완전절제된 수막종에서 수술 후 방사선치료의 역할)

  • Kim Tae-Hyun;Yang Dae-Sik;Kim Chul-Young;Choi Myung-Sun
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.85-91
    • /
    • 2000
  • Purpose : The aim of this study is to look for the possible efficacy of postoperative external irradiation for incompletely resected meningiomas. Methods and Materials : From August 198: to January 1997, forty-four patients with intracranial meningioma were treated by postoperative external irradiation. Of the 44 meningiomas, 18 transitional, 13 meningotheliomatous, 6 hemangiopericytic, 4 atypical, 2 fibroblastic and 1 malignant meningioma were identified. We classified all patients into two groups by the histology. The benign group was consisted of the meningotheliomatous, transitional and fibroblastic types. The malignant group was consisted of the atypical, hemangiopericytic and malignat types. In the means of surgery, 37 patients were resected incompletely and 7 patients were managed by biopsy only. After surgery, all patients were received postoperative external irradiation. Radiotherapy was deliverd using Co-60 or 4 MV photon beam to a total dose of 50 to 65 Gy (mean dose 57.4 Gy) with a 1.8 to 2 Gy per fraction. The median follow-up was 48 months (range : 21 $\~$ 101 months). Multivariate analysis of the Influence by age, sex, location, histology and radiation dose on local control has been done using Cox's proportional hazard model. Results : 5-year local control rate was 93.8$\%$ for the benign histology and 51.8$\%$ for the malignant histology (p=0.0110) and overall local control rate at 5 years was 87.4$\%$. The analysis of the prognostic factors, such as age, sex, location, and radiation dose were not significant except for the histology. Conclusion : Adjuvant postoperative external irradiation appears to be significantly improved local control in the patients with incompletely resected meningiomas.

  • PDF

Treatment of Carcinoma of the Uterine Cervix with High-Dose-Rate Intracavitary Irradiation using Ralstron (고선량률 강내조사를 사용한 자궁경부암의 치료)

  • Suh Chang Ok;Kim Gwi Eon;Loh John J.K.
    • Radiation Oncology Journal
    • /
    • v.8 no.2
    • /
    • pp.231-239
    • /
    • 1990
  • From May 1979 through December 1981 a total of 524 patients with carcinoma of the uterine cervix were treated by radiation therapy with curative intent. Among the 524 patients, 350 were treated with a high-dose-rate (HDR), remote-controlled, afterloading intracavitary irradiation (ICR) system using a cobalt source (Ralstron), and 168 patients received a low-dose-rate (LDR) ICR using a radium source. External beam irradiation with a total dose of 40-50 Gy to the whole pelvis followed by intracavitary irradiation with a total dose of 30-39 Gy in 10-13 fractions to point A was the treatment protocol. ICR was given three times a week with a dose of 3 Gy per fraction. Five-year actuarial survival rates in the HDR-ICR group were $77.6{\%}$ in stage IB (N=20), $68.2{\%}$ in stage II (N=182), and $50.9{\%}$ in stage III (N=148). In LDR-ICR group, 5-year survival rates were $87.5{\%}$ in stage IB (N=22), $66.3{\%}$ in stage II (N=91), and $55.4{\%}$ in stage III (N=52). Survival rates showed a statistically significant difference by stage, but there was no significant difference between the two ICR groups. Late bowel complications after radiotherapy were noted in $3.7{\%}$ of the HDR-ICR group and $8.4{\%}$ of the LDR-ICR group. There was no severe complication requiring surgical management. The incidence of bladder complications was $1.4{\%}$ in the HDR-ICR group and $2.4{\%}$ in the LDR-ICR group. The application of HDR-ICR was technically simple and easily performed on an outpatient basis without anesthesia, and the patients tolerated it very well. Radiation exposure to personnel was virtually nil in contrast to that of LDR-ICR. Within a given period of time, more patients can be treated with HDR-ICR because of the short treatment time. Therefore, the HDR-ICR system is highly recommended for a cancer center, particularly one with a large number of patients to be treated. In order to achieve an improved outcome, however, the optimum dose-fractionation schedule of HDR-ICR and optimum combination of intracavitary irradiation with external beam irradiation should be determined through an extensive protocol.

  • PDF

High versus Low Dose-Rate Intracavitary Irradiation for Adenocarcinoma of the Uterine Cervix (자궁경부 선암 환자에서 고선량률 강내치료와 저선량률 강내치료의 비교)

  • Kim Woo Chul;Kim Gwi Eon;Chung Eun Ji;Suh Chang Ok;Hong Soon Won;Cho Young Kap;Loh JK
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.32-39
    • /
    • 2000
  • Purpose :The incidence of adenocarcinoma of the uterine cervix is low. Traditionally, Low Dose Rate (LDR) brachytherapy has been used as a standard modality in the treatment for patients with carcinoma of the uterine cervix. The purpose of this report is to evaluate the effects of the High dose rate (HDR) brachytherapy in the patients with adenocarcinoma of the uterine cervix compared with the LDR. : From January 1971 to December 1992, 106 patients of adenocarcinoma of uterine cervix were treated with radiation therapy in the Department of Radiation Oncology, Yonsei University with curative intent. LDR brachytherapy was carried out on 35 patients and 71 patients were treated with HDR brachytherapy. In LDR Group, 8 patients were in stage I, 18 in stage II and 9 in stage III. External radiation therapy was delivered with 10 MV X-ray, daily 2 Gy fractionation, total dose 40$\~$46Gy (median 48 Gy). And LDR Radium intracavitary irradiation was peformed with Henschke applicator, 22$\~$59 Gy to point A (median 43 Gy). In HDR Group, there were 16 patients in stage 1, 38 in stage II and 17 in stage III. The total dose of external radiation was 40$\~$61 Gy(median 45 Gy), daily 1.8$\~$2.0 Gy. HDR Co-60 intracavitary irradiation was peformed with RALS (Remote Afterloading System), 30 $\~$ 57 Gy(median 39 Gy) to point A, 3 times a week, 3 Gy per fraction. Conclusion : The 5-year overall survival rate in LDR Group was 72.9$\%$, 61.9$\%$, 45.0$\%$ in stage I, II, III, respectively and corresponding figures for HDR were 87.1$\%$, 58.3$\%$, 41.2$\%$, respectively (p>0.05). There was no statistical difference in terms of the 5-year overall survival rate between HDR Group and LDR Group in adenocarcinoma of the uterine cervix. There was 11$\%$ of late complication rates in LDR Group and 27$\%$ in HDR Group. There were no prognostic factors compared HDR with LDR group. The incidence of the late complication rate in HDR Group stage II, III was higher than that in LDR Group(16.7$\%$ vs. 31.6$\%$ in stage II, 11.1$\%$ vs. 35.3$\%$ In stage III, p>0.05). Although the incidence of radiation induced late complication rate was higher in HDR Group stage II and III patients than that in the LDR Group, statistical significance was not detected and within acceptable level. Conclusion : There was no difference in terms of 5-year survival rate and failure pattern in the patients with adenocarcinoma of the uterine cervix treated with HDR and LDR brachytherapy. Even late complication rates were higher in the HDR group It was an acceptable range. This retrospective study suggests that HDR brachytherapy seems to replace the LDR brachytherapy in the adenocarcinoma of the uterine cervix. However, further studies will be required to refine the dose rate effects.

  • PDF

Reproductive Toxicity Study of DA-125, A New Anthracycline Anticancer Agent: (I) Teratogenicity Study in Rats (새로운 안트라사이클린계 항암제 DA-125의 생식독성연구: (I) 랫트 최기형시험)

  • 정문구;한상섭;양중익;노정구
    • Biomolecules & Therapeutics
    • /
    • v.2 no.1
    • /
    • pp.82-93
    • /
    • 1994
  • DA-125, a new anthracycline antitumor antibiotic, was at dose levels of 0, 0.1, 0.3 and 1.0 mg/kg/day administered intravenously to pregnant Sprague-Dawley rats during the organogenetic period. Two-third of dams per group were subjected to caesarean section on day 20 of pregnancy and the remaining 10 dams per group were allowed to deliver. Effects of test substance on dams, embryonal development of Fl fetuses, as well as growth, behaviour and mating performance of Fl offspring were examined. 1. At 1 mg/kg, one out of the 10 dams showed difficult delivery. A decrease in food consumption, a loss in body weight and a decrease of spleen weight were found in this dose level group. At 0.3 mg/kg, difficult deliverys were observed in two out of the 10 dams. 2. At 1 mg/kg, an increased resorption rate and a decreased fetal weight were found. In addition, various types of external, visceral and skeletal malformations occurred at an incidence of 11.9, 41.8 and 14.5%, respectively. 3. At 1 mg/kg, body weight reduction, small eyeball, hydrocephalus and atrophy of sexual organs were observed in Fl offspring. One male pup receiving 0.3 mg/kg died on day 2 of lactation. The results show that the no-effect dose levels (NOELs) for dams and Fl offspring are 0.1 mg/kg/day and NOEL for Fl fetuses is 0.3 mg/kg/day.

  • PDF

Brachytherapy: A Comprehensive Review

  • Lim, Young Kyung;Kim, Dohyeon
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.25-39
    • /
    • 2021
  • Brachytherapy, along with external beam radiation therapy (EBRT), is an essential and effective radiation treatment process. In brachytherapy, in contrast to EBRT, the radiation source is radioisotopes. Because these isotopes can be positioned inside or near the tumor, it is possible to protect other organs around the tumor while delivering an extremely high-dose of treatment to the tumor. Brachytherapy has a long history of more than 100 years. In the early 1900s, the radioisotopes used for brachytherapy were only radium or radon isotopes extracted from nature. Over time, however, various radioisotopes have been artificially produced. As radioisotopes have high radioactivity and miniature size, the application of brachytherapy has expanded to high-dose-rate brachytherapy. Recently, advanced treatment techniques used in EBRT, such as image guidance and intensity modulation techniques, have been applied to brachytherapy. Three-dimensional images, such as ultrasound, computed tomography, magnetic resonance imaging, and positron emission tomography are used for accurate delineation of treatment targets and normal organs. Intensity-modulated brachytherapy is anticipated to be performed in the near future, and it is anticipated that the treatment outcomes of applicable cancers will be greatly improved by this treatment's excellent dose delivery characteristics.

Study of Patient's Position to Reduce Late Complications in High Dose Rate Intracavitary Radiation of the Uterine Cervix Cancer (자궁경부암의 고선량율 강내 방사선치료 시 부작용을 줄이기 위한 적정 치료 자세의 연구)

  • Yun, Hyong-Geun;Shin, Kyo-Chul
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.477-483
    • /
    • 1998
  • Purpose : Radiation proctitis and radiation cystitis are frequent and problematic late complications in patients treated with radiation for the uterine cervix cancer. Authors tried to find out the better patient's position in high dose rate intracavitary radiation to reduce the radiation dose of bladder and rectum. Materials and Methods : In 13 patients, Foley Catheters were inserted to patient's bladder and rectum and were ballooned with radioopaque dye. After insertion of a tandem and two ovoids, semi-orthogonal anteroposterior and lateral films were taken in both lithotomy and supine position. The rectal point and bladder point were defined according to the criteria recommended in the ICRU Report 38 with modification. Using these films, all patients' bladder and rectal dose were calculated in both positions (the radiation dose of A point was set to 400 cGy). And also, the distance of bladder and rectum from uterine cervical os was calculated in both positions. Results : The average radiation dose of rectum was 240.7 cGy in lithotomy position and 278.3 cGy in supine position, and the average radiation dose of bladder was 303.5 cGy in lithotomy position and 255.8 cGy in supine position. After the paired t-test, the radiation dose of rectum in lithotomy position was marginally significantly lower than that in supine position, while the radiation dose of bladder in lithotomy position was significantly higher than that in supine position. On the other hand, the average distance between rectum and cervical os was 35.2 mm in lithotomy position and 32.3 mm in supine position. and the average distance between bladder and cervical os was 30.4 mm in lithotomy position and 34.0 mm in supine position. After the paired t-test. the distance between rectum and cervical os in lithotomy position was significantly longer than that in supine position, while the distance between bladder and cervical os in lithotomy position was significantly shorter than that in supine position. Conclusion : The radiation dose of bladder can be reduced in supine position and the radiation dose of rectum can be reduced in lithotomy position, so we can choose appropriate position in each patient.

  • PDF