• Title/Summary/Keyword: External Diffusion

Search Result 196, Processing Time 0.024 seconds

Development of Organization-level Evaluation Model and Process for Information Systems Quality (조직 수준의 정보시스템 품질평가 모형과 절차 개발)

  • Lee, Sang-Ho;Cho, Sung-Rim;Ahn, Byung-Oh
    • Journal of Information Technology Services
    • /
    • v.7 no.4
    • /
    • pp.151-165
    • /
    • 2008
  • This study suggests the organization-level standard(model and process) for quality evaluation of information systems(IS) in non-use organizations despite international standards(ISO/IEC 9126 and ISO/IEC 14598) and national standards(KS X 9126 and KS X 14598) related to quality evaluation of IS. The standard in this study is composed of quality evaluation processes, a quality model, and quality metrics. The weights of the attributes and the sub-attributes in the quality model were calculated by an analytic hierarchy process(AHP). The minimum level and the target level of each metrics were determined by brainstorming of the committee. Furthermore, the case study for the investigation of the applicability and the usability of the suggested organizational standard in the real IS development project was performed. For gaining significant benefits of the standard, both the diffusion and the experience accumulation by its continuous use are needed.

Microstructures and Cyclic Oxidation Resistance of Aluminide Coatings for Inconel 600 (Inconel 600에 있어서 Al抗散浸透 被覆層의 微細組織과 耐反復酸化性)

  • Chung, In-Sang;Byun, Chang-Suk
    • Journal of the Korean institute of surface engineering
    • /
    • v.20 no.2
    • /
    • pp.60-73
    • /
    • 1987
  • For the purpose of improving the cyclic oxidation resistance of Ni-base superalloy, Inconel 600, aluminide coating methods are studied. The formation rate of aluminide coating layers is measured as a function of time and pack composition to find out the optimum coating condition. The evaluation of cyclic oxidation is established by the change in weight, the microphotography and EPMA of cross sectional area during $200^{\circ}C\;{\leftrightarrow}\;950^{\circ}C\;and\;200^{\circ}C\;{\leftrightarrow}\;1100^{\circ}C$, respectively. The thickness of coating layer and weight gains are parabolic behavior in propotion to time and Al contents. In pack of low aluminum contents, 2 wt%, however, weight gain is decreased when activator, $NH_4Cl$ is higher than 2 wt%. The cyclic oxidation resistance of the coating carried out at 1100$^{\circ}C$ are superior to those of the coating diffusion-treated after pack cementation at 800$^{\circ}C$. Aluminide oxide, which is formed in external scale, is barrier to the cyclic oxidation.

  • PDF

Estimation of Effective Dose to Residents Due to Hypothetical Accidents During Dismantling of Steam Generator

  • Kyeong-Ju Lee;Chang-Lak Kim
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.183-191
    • /
    • 2023
  • The potential impact of hypothetical accidents that occur during the immediate and deferred dismantling of the Kori Unit 1 steam generator has been comprehensively evaluated. The evaluation includes determining the inventory of radionuclides in the Steam Generator based on surface contamination measurements, assuming a rate of release for each accident scenario, and applying external and internal exposure dose coefficients to assess the effects of radionuclides on human health. The evaluation also includes calculating the atmospheric dispersion factor using the PAVAN code and analyzing three years of meteorological data from Kori NPP to determine the degree of diffusion of radionuclides in the atmosphere. Overall, the effective dose for residents living in the Exclusion Area Boundary (EAB) of Kori NPP is predicted, an it is found that the maximum level of the dose is 0.034% compared to the annual dose limit of 1 mSv for the general public. This implies that the potential impact of hypothetical accidents on human health discussed above is within acceptable limits.

Prediction of Long-Term Carbonation Depth by Measurement of the Air Permeability Coefficient of Coating on Concrete (콘크리트에 도포된 도막의 투기계수 측정을 통한 장기 중성화 깊이 예측)

  • Park, Dong-Cheon;Nam, Min-Seok;Kim, Yong-Ro;Ko, Hyo-Jin;Ryu, Dong-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.113-114
    • /
    • 2023
  • This study measured the thickness and speculation coefficient of the coating for existing buildings and calculated the diffusion coefficient of the coating to predict the depth of carbonation through numerical analysis in order to evaluate the impact of the external finish and local environment. As a result, it was possible to predict the short-term and long-term carbonation depth of reinforced concrete buildings coated with coating film with considerable reliability.

  • PDF

A Study on Technological Forecasting of Next-Generation Display Technology (차세대 디스플레이 기술의 예측에 관한 연구)

  • Nam, Ki-Woong;Park, Sang-Sung;Shin, Young-Geun;Jung, Won-Gyo;Jang, Dong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2923-2934
    • /
    • 2009
  • This paper presents study on technological forecasting of Next-Generation Display technology. Next-Generation Display technology is one of the emerging technologies lately. So databases on patent documents of this technology were analyzed first. And patent analysis was performed for finding out present technology trend. And the forecast for this technology was made by growth curves which were obtained from forecast models using patent documents. In previous study, Gompertz, Logistic, Bass were used for forecasting diffusion of demand in market. Gompertz, Logistic models which were often used for technological forecasting, too. So, two models were applied in this study. But Gompertz, Logistic models only consider internal effect of diffusion. And it is difficult to estimate maximum value of growth in two models. So, Bass model which considers both internal effect and external effect of diffusion was also applied. And maximum value of growth in Gompertz, Logistic models was estimated by Bass model.

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

Luminance Normalization of Optical Sheets in a Backlight Unit for LCD-TVs (LCD-TV용 백라이트 광학시트의 휘도 정량화)

  • Jeong, Jong-Mun;Kim, Jung-Hyun;Shin, Myeong-Ju;Lee, Mi-Ran;Chung, Jae-Yoon;Jeong, Hee-Suk;Kim, Jin-Sheon;Hong, Byeong-Hee;Kang, June-Gill;Cho, Guang-Sup
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.424-432
    • /
    • 2007
  • Luminance properties of external electrode fluorescent lamps and optical components in backlight unit (BLU) and optical transmission rates of optical sheets, are investigated for LCD-TV of 32" in diagonal with WXGA level resolution (1366$\times$768). The luminance is measured in 12-lamps and 18-lamps of BLU. The luminance uniformity preserves about 85 % in the 12-lamps backlight, while the luminance of optical components and the efficiency of backlight in the 12-lamps are lower than those in the 18-lamps backlight. When the lamp luminance in BLU having 12-lamps and 18-lamps is normalized as 100 %, the relative luminance of a diffusion plate, a diffusion sheet, a prism sheet (BEF), a polarization sheet (DBEF), has a constant value without dependence on a lamp luminance. The relative luminance of optical components in 12-lamps BLU is lower than that in 18-lamps backlight. The light transmission rate, the relative luminance of liquid crystal display panel with the luminance 100 % of backlight, is 7.14 % in the use of DBEF and BEF, 6.12 % in the use of only DBEF, and 3.21 % in the use of only BEF. Those Data obtained in this experiment for the lamps and optical components, are the design parameters for the LCD backlight.

The Study on the Bi-directional Ejection Air Curtain System for Blocking Smoke Diffusion in case of Tunnel Fire (터널 화재시 연기확산 차단을 위한 양방향 토출 에어커튼 시스템에 대한 연구)

  • Yang, Sang-Ho;Choi, Young-Seok;Kim, Jung-Yup;Kim, Nam-Goo;Kim, Kyung-Yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.5
    • /
    • pp.43-53
    • /
    • 2014
  • This paper presents a the study on air curtain system of top and bottom bi-directional jet air discharge for blocking the spread of smoke in case of tunnel fire. The five kinds different air curtains of A, B, C, D, and E of models for various performance tested after manufactured. A results of the various performance test obtained the best efficiency from E model air curtain. And optimize the injection angle of the air curtain nozzle through the three-dimensional computational fluid dynamics (CFD) analysis and analyzed the effects of external pressure of tunnel. and also single factor design have been applied. At present, our attention is focused on the velocity distribution(flow width and flow position) of 1.5m on the ground in tunnel. Also, analyzed the influence of draft in the tunnel. Detailed effects of discharge angle of air curtain and velocity at nozzle exit are discussed.

Probabilistic Service Life Evaluation for OPC Concrete under Carbonation Considering Cold Joint and Induced Stress Level (콜드조인트 및 재하 응력을 고려한 탄산화에 노출된 OPC 콘크리트의 확률론적 내구수명평가)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.6
    • /
    • pp.45-52
    • /
    • 2019
  • Steel corrosion due to carbonation in RC (Reinforced Concrete) structures easily occurs in urban cities with high CO2 concentration. RC structures are always subjected to external loading with various boundary conditions. The induced stress level causes changes in diffusion of harmful ion like CO2. In this work, a quantification of carbonation progress with stress level is carried out and carbonation prediction is derived through the relations. Determining the design parameters like cover depth, CO2 diffusion coefficient, carbonatable materials, and exterior CO2 concentration as random variables, service lifes under carbonation with design parameter's variation are obtained through MCS(Monte Carlo Simulation). Additionally the service life with different stress level is derived and the results are compared with those from deterministic method. Cover depth and cement hydrates are evaluated to be very effective to resist carbonation, and the proposed method which can consider the effect of stress on service life can be applied to maintenance priority determination.

Removal of Cs and Sr Ions by Absorbent Immobilized Zeolite with PVA (제올라이트를 PVA로 고정화한 흡착제에 의한 Cs과 Sr 이온 제거)

  • Lee, Chang-Han;Lee, Min-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.8
    • /
    • pp.450-457
    • /
    • 2015
  • In this research a adsorbent, PVA-Zeolite bead, was prepared by immobilizing zeolite with PVA. The results of XRD and SEM analysis showed that the prepared PVA-Zeolite beads had porous structure and the zeolite particles were in mobilized within the internal matrix of the beads. The adsorption properties of Sr ion and Cs ion with the adsorbent were studied by different parameters such as effect of pH, adsorption rate, and adsorption isotherm. The adsorption of Sr ion and Cs ion reached equilibrium after 540 minutes. The adsorption kinetics of both ions by the PVA-Zeolite beads were fitted well by the pseudo-second-order model more than pseudo-first-order model. The equilibrium data fitted well with Langmuir isotherm model. The maximum adsorption capacities of Sr ion and Cs ion calculated from Langmuir isotherm model were 52.08 mg/g and 58.14 mg/g, respectively. The external mass transfer step was very fast compared to the intra-particle diffusion step in the adsorption process of Cs ion and Sr ion by the PVA-Zeolite beads. This result implied that the rate controlling step was the intra-particle diffusion step.