• 제목/요약/키워드: External Cooling

검색결과 298건 처리시간 0.021초

주상복합의 실외기 형태에 따른 냉방시스템 성능 평가 (The performance evaluation of outdoor unit cooling system in a residential apartment complex)

  • 경서경;김윤진;임정희;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

차양장치의 겨울철 천공복사 냉각 저감 효과에 관한 실험적 연구 (An Experimental Study on the Reduction Effects of Shading Devices on Sky Radiant Cooling in Winter)

  • 김진희;김영탁;이수열;최원기
    • 토지주택연구
    • /
    • 제12권1호
    • /
    • pp.129-137
    • /
    • 2021
  • 외부 차양장치는 대표적인 여름철 일사조절 장치이다. 특히 냉방부하가 높은 업무용 건물에 적합한 기술로 인식되어왔다. 그러나 본 연구에서는 차양장치의 냉방부하 저감뿐만 아니라 난방부하 저감 효과를 검증하기 위한 실험을 수행하였다. 이를 위해 겨울철 야간 천공복사냉각에 따른 영향을 중심으로 일반 창호, 롤 블라인드, 외부 차양장치를 대상으로 실험을 수행하였으며, 그 결과는 다음과 같다. 외부 차양장치가 적용된 경우 유리 내·외표면 온도차는 평균 11.8℃로 차양장치가 없는 경우의 14.6℃ 보다 평균 2.8℃ 낮은 온도차를 나타냈으며, 이는 천공복사에 의한 열교환으로 차양 표면온도가 외기온도보다 낮은 시간때에 발생한다. 한편, 롤 블라인드는 내부 중공층의 평균온도보다 0.8℃ 낮은 온도를 나타냈으며 이 또한 투과체를 통과한 천공복사가 롤 블라인드 표면과 열교환이 이뤄졌기 때문이다. 유리 외부 표면온도만을 고려하면 약 3℃ 이상의 온도 상승이 예상된다. 그리고 차양장치가 없는 경우 일반적인 온도구배를 나타내고 있었다. 한편 남동향과 남서향에 외부 차양장치가 설치되었을 때 남서향의 외측 유리 표면온도가 더 낮게 나타나는 특징이 있다. 이 결과는 천공복사에 의한 냉방 저감 효과를 정량화할 수는 없지만 적어도 타당성은 확인할 수 있었다. 향후 연구에서는 천공복사 냉각과 에너지 소비 사이의 상관관계를 조사하고 외부 차양장치의 난방에너지 절감 효과에 대한 독립 챔버 실험을 진행할 계획이다.

흡습 냉각 원리를 이용한 소형 냉각 패드에 관한 연구 (Conceptual Development of a Subminiature Cool Pad Applying Sorption Cooling Effect)

  • 황용신;이대영;김우승
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.121-127
    • /
    • 2004
  • This paper describes conceptual development and idea-verification of a sub-miniature portable cooler which dose not necessitate any pre-cooling nor any external energy supply. The basic principle of the cooling mechanism is the vaporization of water and sub-sequent cooling due to the evaporative latent heat loss. In this work, the vaporization of the water is stimulated by desiccant material to improve the cooling effect. The evaporative cooling caused by the desiccant is modeled and analyzed considering the sorption characteristics of the desiccant. In addition, the portable cooler is fabricated in the shape of a thin pad, and its cooling characteristics are tested and compared with the analytic results.

단열재 조건에 따른 원자로용기 외벽냉각 성능 예비분석 (A Preliminary Assessment on ERVC Performance Depending on Insulation Conditions)

  • 최동현;장윤석
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.36-43
    • /
    • 2023
  • Lots of researches have been conducted on in-vessel retention (IVR) to prevent or mitigate severe accident in nuclear power plants. Various methodologies were proposed and the external reactor vessel cooling was selected as a part of promising IVR strategy. In this study, the strategy is strengthened by enhancing the natural circulation performance through the adoption of insulation in the reactor cavity. A thermal analysis was carried out based on an assumed accident scenario and its results were used as boundary conditions for subsequent seven flow analysis cases. By comparing the natural circulation performance, effects of annular gaps and insulation shapes on the mass flow rate and flow velocity were quantified. The improvement in cooling performance can be reflected in actual design via detailed assessment.

기존 학교 건물의 외피 성능 개선 방안에 관한 연구 (The Improvement of Building Envelope Performance in Existing School Building)

  • 방아영;박세현;김진희;김용재;김준태
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: This study is to investigate the effects of facade insulation and window remodeling of an existing old middle school building on the reduction of energy consumption. Method: To analyze energy performance of building, using DesignBuilder v3.4, building energy simulation tool based EnergyPlus engine. Energy consumption and problem of target building was analyzed based on data and survey. Based on building energy simulations it analyzed the variation of energy demand for the building according to U-value of wall, glazing properties and external shading devices. Result: When insulation of building was reinforced, cooling and heating load was decreased. Glazing properties that minimize cooling and heating energy consumption were analyzed. In conclusion, it is important to choose SHGC and U-value of window fit in characteristic of target building. Setting external blind for cooling load decreases 5%.

Sensitivity Studies on Thermal Margin of Reactor Vessel Lower Head During a Core Melt Accident

  • Kim, Chan-Soo;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.379-394
    • /
    • 2000
  • As an in-vessel retention (IVR) design concept in coping with a severe accident in the nuclear power plant during which time a considerable amount of core material may melt, external cooling of the reactor vessel has been suggested to protect the lower head from overheating due to relocated material from the core. The efficiency of the ex-vessel management may be estimated by the thermal margin defined as the ratio of the critical heat flux (CHF)to the actual heat flux from the reactor vessel. Principal factors affecting the thermal margin calculation are the amount of heat to be transferred downward from the molten pool, variation of heat flux with the angular position, and the amount of removable heat by external cooling In this paper a thorough literature survey is made and relevant models and correlations are critically reviewed and applied in terms of their capabilities and uncertainties in estimating the thermal margin to potential failure of the vessel on account of the CHF Results of the thermal margin calculation are statistically treated and the associated uncertainties are quantitatively evaluated to shed light on the issues requiring further attention and study in the near term. Our results indicated a higher thermal margin at the bottom than at the top of the vessel accounting for the natural convection within the hemispherical molten debris pool in the lower plenum. The information obtained from this study will serve as the backbone in identifying the maximum heat removal capability and limitations of the IVR technology called the Cerium Attack Syndrome Immunization Structures (COASISO) being developed for next generation reactors.

  • PDF

Two Dimensional Analysis for the External Vessel Cooling Experiment

  • Yoon, Ho-Jun;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.410-423
    • /
    • 2000
  • A two-dimensional numerical model is developed and applied to the LAVA-EXV tests performed at the Korea Atomic Energy Research Institute (KAERI) to investigate the external cooling effect on the thermal margin to failure of a reactor pressure vessel (RPV) during a severe accident. The computational program was written to predict the temperature profile of a two-dimensional spherical vessel segment accounting for the conjugate heat transfer mechanisms of conduction through the debris and the vessel, natural convection within the molten debris pool, and the possible ablation of the vessel wall in contact with the high temperature melt. Results of the sensitivity analysis and comparison with the LAVA-EXV test data indicated that the developed computational tool carries a high potential for simulating the thermal behavior of the RPV during a core melt relocation accident. It is concluded that the main factors affecting the RPV failure are the natural convection within the debris pool and the ablation of the metal vessel, The simplistic natural convection model adopted in the computational program partly made up for the absence of the mechanistic momentum consideration in this study. Uncertainties in the prediction will be reduced when the natural convection and ablation phenomena are more rigorously dealt with in the code, and if more accurate initial and time-dependent conditions are supplied from the test in terms of material composition and its associated thermophysical properties.

  • PDF

Characteristics of wind loading on internal surface and its effect on wind-induced responses of a super-large natural-draught cooling tower

  • Zou, Yun-feng;Fu, Zheng-yi;He, Xu-hui;Jing, Hai-quan;Li, Ling-yao;Niu, Hua-wei;Chen, Zheng-qing
    • Wind and Structures
    • /
    • 제29권4호
    • /
    • pp.235-246
    • /
    • 2019
  • Wind loading is one of important loadings that should be considered in the design of large hyperbolic natural-draught cooling towers. Both external and internal surfaces of cooling tower are under the action of wind loading for cooling circulating water. In the previous studies, the wind loads on the external surface attracted concernedly attention, while the study on the internal surface was relatively ware. In the present study, the wind pressure on the internal surface of a 220 m high cooling tower is measured through wind tunnel testing, and the effect of ventilation rate of the packing layer on internal pressure is a major concern. The characteristics of internal wind pressure distribution and its effect on wind-induced responses calculated by finite element method are investigated. The results indicate that the wind loading on internal surface of the cooling tower behaves remarkable three-dimensional effect, and the pressure coefficient varies along both of height and circumferential directions. The non-uniformity is particularly strong during the construction stage. Analysis results of the effect of internal pressure on wind-induced responses show that the size and distribution characteristics of internal pressure will have some influence on wind-induced response, however, the outer pressure plays a dominant role in the wind-induced response of cooling tower, and the contribution of internal pressure to the response is small.

The combined effect of extraoral vibratory stimulus and external cooling on pain perception during intra-oral local anesthesia administration in children: a systematic review and meta-analysis

  • Tirupathi, Sunny Priyatham;Nanda, Neethu;Pallepagu, Sneha;Malothu, Sardhar;Rathi, Nilesh;Chauhan, Rashmi Singh;Priyanka, VakaJeevan;Basireddy, Rameshreddy
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권2호
    • /
    • pp.87-96
    • /
    • 2022
  • This study aimed to assess the combined use of extraoral vibratory stimulation and extraoral cooling in reducing the pain (subjective and objective) of dental local anesthesia administration in children. PubMed, Cochrane Central Register of Controlled Trials, and Ovid SP databases were searched up to July 2021. Article titles were screened and full-text evaluations of the selected articles were performed. Finally, seven studies (391 children, aged 4 - 12 years) were included in this qualitative and quantitative analysis. The pooled data determined the combined effect of extraoral vibration and extraoral cooling as a single measure. Extraoral vibration or cooling alone were not compared. The measured primary and secondary outcomes were pain perception and subjective and objective pain, respectively. When compared with the control, extraoral vibration and cooling resulted in significant differences in the mean combined data for the variables, pain perception, and pain reaction. Children's subjective pain as measured by pain scores were reduced when extraoral vibration and cooling was used during local anesthesia administration (mean difference -3.52; 95% confidence interval [-5.06 - 1.98]) and objective pain (mean difference -1.46; 95% confidence interval [-2.95 - 0.02] ; mean difference -1.93; 95% confidence interval [-3.72 - 0.14]). Within the confines of this systematic review, there is low-quality evidence to support the use of combined extraoral vibration and cooling for reducing pain (subjective and objective) during intraoral local anesthesia administration in children.

CICC 형태의 초전도 버스 선에서 냉각 및 자기장에 의한 응력 해석 (Analysis of the stresses induced by magnetic field and cooling in the CICC type superconducting bus-line)

  • 이호진;남현일;김기백;홍계원
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제2권2호
    • /
    • pp.20-25
    • /
    • 2000
  • A CICC type superconducting bus-line electrically connecting a superconducting magnet to a power supply is cooled down to low temperature under the external magnetic field during operation. The thermal contraction during the cooling may be constrained by the supports which are installed to protect the bus-line from Lorenz magnetic forces. This constrained contraction causes thermal stresses in the bus-line to release thermal contraction. The minimum stress conditions in the bus-line may be optimized by controlling the supporting arrangement considering the thermal contraction and the external field. The analytical method to find optimal supports arrangement was suggested by using the beam theory, and numerical calculation using commercial code was performed to verify the suggested analytical optimization method.

  • PDF