• 제목/요약/키워드: Exterior wall

검색결과 272건 처리시간 0.023초

교육시설물의 합리적인 유지관리를 위한 비용분류체계 (Cost Breakdown Structure for Reasonable Maintenance of Educational Facilities)

  • 정재혁;신한우;김태희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.65-67
    • /
    • 2011
  • It is necessary to the development of the best maintenance system for applying the long-term maintenance plan using the cost breakdown structure in the educational facilities. This study developed the cost breakdown structure for the best maintenance system using the delphi method. For the convenience of maintenance, the maintenance cost breakdown structures are separated into building exterior wall, building inside wall, electric installation, heating installation and outdoor facilities. And these results atomized in each parts. And this study constructed the cost breakdown structure to maintenance's practicality and effectiveness through the expert analysis.

  • PDF

반사파가 존재하는 실내 공간에서의 음원 탐지 방법 (Source Identification in an Interior Sound Field)

  • 최영철;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1203-1209
    • /
    • 2001
  • Identification of noise sources, their locations and strengths, have been taken great attention. The method that can identify noise sources normally assumes that noise sources are located at a free field. However, the sound in a reverberant field consists of that coming directly from the source plus sound reflected or scattered by the walls or objects in the field. In contrast to the exterior sound field, reflections are added to sound field. Therefore, we have to consider the reverberation effect on the source identification method. The main objective of this paper is to identify noise source in the reverberant field. At fist, we try to identify noise sources in a rigid wall enclosure using the spherical beamforming method. In many case of practical interest, the wall has an admittance so that complex reflection process occurred. In this paper, we assumed the complex reverberant field in the enclosure to be the sum of plane waves with random incidence and magnitude. Then the effects of reverberant field at interior source identification have been studied theoretically as well as experimentally

  • PDF

한옥 유지관리매뉴얼 개발을 위한 결함 유형 현장 조사 (A Field Investigation of Defect Type for Development of Maintenance Manual of Han-ok)

  • 이종신;최광식;양정무
    • 한국가구학회지
    • /
    • 제24권3호
    • /
    • pp.302-308
    • /
    • 2013
  • To collection of field data for development of maintenance manual of Han-ok, we investigated defects which occurred in members of Han-ok by field investigation. The noticeable defects were wood cracks, gaps that developed between wood pillar and wall or wood window frame and tenon joints. The most common biological defect was blue stain which was created in log. The mold generation was observed on exterior wood and wall which get wet by precipitation. The gaps between members of Han-ok pointed out as defect that is urgently improved by residents of Han-ok. The reason is mainly due to poor of insulation in winter by bad confidentiality. The maintenance work of defect such as gap was conducted personally. As a result, the repair parts were ugly for unfamiliar repair work.

  • PDF

공동주택의 단열현황 조사 및 단열보강 적용방안에 관한 연구 ((A)Study on Apartment Insulation Status and Insulation reinforcement Application)

  • 정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2015
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. The following conclusions could be derived thorough the investigation of outer wall temperature distribution and the insulation assesment experiments using a model of specimens for the apartment houses' outer walls. It was confirmed that for the thermal performance through the insulating material thicknesses 5cm, 8cm in walls, the thermal insulation thickened by 3cm, from 5cm to 8cm, but that the actual temperature difference reached only about 1 ~ 2℃. This implies that the thermal performance improvement using the thermal insulation in walls is not significant and that it is difficult to insulate the thermal bridge area.

  • PDF

실내 공간에서의 음원 탐지 방법 (Source Identification in an Interior Sound Field)

  • 김양한;최영철
    • 한국소음진동공학회논문집
    • /
    • 제12권7호
    • /
    • pp.520-526
    • /
    • 2002
  • Identification of noose sources, their locations and strengths, has been taken great attention. The methods that can identify noise sources normally assume that noise sources are located in a free field. However, the sound in a reverberant field consists of that coming directly from the source plus sound reflected or scattered by the walls or objects in the field. In contrast to the exterior sound field. reflections are added to sound field. Therefore, we haute to consider the reverberation effect on the source identification method. The main objective of this paper is to identify noise source in the reverberant field. At fist, we try to identify noise sources in a rigid wall emc;psire using the beamforming method. In many cases of practical interest, the wall has admittance so that random reflections occur in an enclosure. In this paper, we assumed the complex reverberant field in the enclosure to be the sum of plane caves with random Incidence and magnitude. Then we try to explain effects of reverberant field at interior source identification.

공동주택 지하바닥 및 외벽부위 방수설계를 위한 방수공법 제안 (Waterproofing Method for Waterproof Design of Underground Floor and Exterior Wall of Residential Buildings)

  • 이정훈;서현재;최은규;송제영;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.233-234
    • /
    • 2019
  • Research has begun to change the waterproofing design of domestic underground structure parts from the current negative-side waterproof design to the positive-side waterproof design. For this, active review from the design stage to prevent the ingress of external ground water into the waterproofing measures of the underground of apartment buildings is needed. Therefore, in this study, proper waterproofing method for the major leaks identified in the previous studies and a waterproofing method for the waterproof design of the underground floor and the outer wall is proposed. It is hoped that a follow-up study, such as a review of field applicability, for the proposed methods will provide an alternative to secure leakage stability in waterproof design.

  • PDF

근대건축물 리모델링을 위한 습열 거동 분석을 통한 설계기법 연구 -광주 지성고시원 외벽을 중심으로- (A Study on Modern Architecture Remodeling Design Technique through Analysis of Hygrothermal Simulations - Focusing on Ji-Sung Accommodation's wall in Gwangju -)

  • 김동준;천득염;김태룡;오세규
    • 건축역사연구
    • /
    • 제29권6호
    • /
    • pp.7-18
    • /
    • 2020
  • The domestic of modern architectural remodeling method emphasizes simple aesthetic elements, and the correct design and construction methods are not established based on quantitative grounds, thus damaging the value of cultural properties. This study attempts to re-examine the value of modern buildings recognized as old buildings. It is a basic step to present the correct remodeling of the building. The design criteria for exterior wall remodeling of modern buildings were presented. These research results are suitable for energy conservation design standards and can prevent defects in buildings. In the future, more accurate analysis will be required by securing physical property values for various domestic materials through subsequent research.

건물 외벽 청소 시스템의 무인자동화에 관한 연구 (Study of Automatic Cleaning Tool Designs for Exterior Wall of Buildings)

  • 이진구;김대명;이동주
    • 대한기계학회논문집A
    • /
    • 제37권6호
    • /
    • pp.815-820
    • /
    • 2013
  • 고층 건물 외벽의 유지보수작업은 매우 위험하며 건설부분 산업재해에서 추락이 상당부분을 차지하고 있다. 국내에서 수행되는 고층 건물 외벽의 유지보수작업은 재래식 로프와 곤돌라를 이용한 방법이 대부분이며, 이는 잦은 안전사고의 발생과 생산성 저하의 원인이 된다. 특히 비정형 형태의 고층 건물이 증가함에 따라 외벽 유지보수작업의 안전사고율이 매년 증가하고 있으며 사고의 상당부분이 사망으로 이어지고 있다. 이와 같은 산업재해와 숙련공의 노령화는 향후 건설인력수급의 불균형을 초래할 것으로 예상된다. 이에 대한 해결책으로 건설 산업의 자동화가 필수적이다. 고층 건물 외벽 유지보수의 자동화는 산업재해의 감소와 비용의 절감을 기대할 수 있다. 본 연구에서는 빌트-인 가이드 방식의 로봇시스템에 탑재되어 청소를 수행할 수 있는 자동화 기구를 기안하고 상용화를 위한 연구를 수행하였다.

부재속성에 따른 균열 형상 분석에 관한 연구 - 공동주택 외벽 균열을 중심으로 - (A Study of Crack Shape Analysis based on Properties of Member in Apartment Exterior Wall)

  • 김만장
    • 한국건설관리학회논문집
    • /
    • 제16권3호
    • /
    • pp.143-151
    • /
    • 2015
  • 콘크리트 구조물에 발생하는 균열은 구조물의 내력, 내구성, 방수성 등 모든 기능을 저하시키는 주요한 원인으로, 그 대책의 필요성은 구조물이 존재하는 한 계속될 것이다. 하지만 콘크리트 구조물에서의 균열은 재료와 시공 및 사용환경, 구조적 요인 등 다양한 변수가 복합적으로 작용하고 있어 이에 대한 대책 마련과 사전 예방이 쉽지 않은 것이 현실이다. 이에 본 연구에서는 공동주택 외벽에서 균열이 발생한 사례를 분석하여 이에 대한 데이터베이스를 구축하고, 발생한 균열과 부재의 속성간의 관계를 상관관계를 도출하고자 한다. 이는 각 부재가 가지는 기본적 속성이 유사함을 고려하여 균열과 부재의 관계를 분석하고 부재의 속성을 검토하여 균열에 대한 대책 마련에 일조하고자 함이다.

초고층건물에서 아웃리거 구조의 최적위치에 대한 캡 트러스가 미치는 영향 (Effect of Cap Truss on Optimal Outrigger Location in Tall Building)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.40-49
    • /
    • 2013
  • 본 연구는 구조해석 프로그램 MIDAS-Gen을 사용하여 80층 건물의 구조분야에 대한 계획설계를 실시한 후에 캡 트러스가 설치된 초고층건물의 아웃리거 구조의 최적위치에 대하여 연구하는 것을 목적으로 하였다. 이 논문에서 구조해석의 주요한 변수는 아웃리거 위치와 주요한 구조요소 (아웃리거, 외곽기둥, 전단벽 등)의 강성이다. 캡 트러스가 설치된 초고층건물의 아웃리거 구조의 최적위치를 찾기 위하여 초고층건물의 구조설계에서 가장 중요하게 고려해야하는 요소의 하나인 최상층의 수평변위를 분석하고 고찰하였다. 본 연구의 결과, 아웃리거 위치와 아웃리거, 외곽기둥, 전단벽과 같은 주요한 구조요소의 강성은 최적의 아웃리거 위치에 영향을 주는 것으로 나타났다. 그리고 본 연구의 결과는 초고층건물의 수평변위를 최소화시키는 최적의 아웃리거 위치를 결정할 수 있는 기본적인 엔지니어링 자료를 제공하는 것으로 나타났다.