Numerical analysis for the optimum design of a triple-glazed airflow window (환기식 3중 집열창의 최적설계를 위한 수치해석 연구)

  • Kim, H.J.;Hwang, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.484-496
    • /
    • 1997
  • The fluid flow and heat transfer characteristics of conjugate forced and natural convection in the triple-glazed airflow window, where the outer air passes through a space contrived between the interior and exterior window panes, were studied numerically by a finite volume method for the elliptic form of the Navier-Stokes equations. The investigation focused on the influence of window geometry, ventilastion rate and solar energy on the temperature, velocity distribution and thermal performance of the airflow window. The comparison between the triple-glazed airflow window and the enclosed triple-glazed window was also made to evaluate the effect of buoyancy upon which the thermal performance of the window depended.

  • PDF

Analysis of basic IAQ management factors in KTX passenger cabin (KTX 객실의 IAQ 관리 기초 인자 분석)

  • Cho Young-Min;Park Duckshin;Park Byunghyun;Park Eunyoung
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1153-1158
    • /
    • 2005
  • The passenger cabin of train is generally insulated from exterior environment to ensure the safety of passengers and to enhance the heating and cooling efficiency. Therefore, the IAQ management of passenger cabin is very important in aspect of amenity and health of passengers. In this study, we measured some IAQ factors influencing on the indoor air quality of passenger cabin. The measurement was carried out to investigate the PM-10, PM-2.5, PM-1.0, temperature, relative humidity, carbon monoxide, carbon dioxide leves of KTX. The results showed that the air quality of the cabin was largely satisfactory, but carbon dioxide level was relatively higher. The control of carbon dioxide levels need the extensive research in the future.

  • PDF

A Study on the Application of Fixed-concentrated PV Module Hybrid Panel for BIPV (고정식 집속형 PV모듈 복합패널의 BIPV적용성 검토)

  • Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.77-83
    • /
    • 2005
  • The verified thermal efficiency, thermal capacity confirmed the effects of the cooling system. Therefore, it is useful for preventing the PV cell temperature rising when solar radiation accumulates in summer. When adopting a hybrid panel for the BIPV system, the affected areas include the vertical outside walls facing the south, southeast, and southwest on the curtain walls excluding windows. The standards on replace aluminum panel which were the popular exterior material were investigated, Designing practice made sure that it could be manufactured in various sizes, and confirmed the most proper method to install a hybrid panel in the BIPV system.

A Study on Hybrid Living Space in Digital Architecture (디지털건축에서 추구하는 하이브리드한 주거공간에 관한 연구)

  • 이철재
    • Korean Institute of Interior Design Journal
    • /
    • no.29
    • /
    • pp.289-296
    • /
    • 2001
  • Changing demographics, changing lifestyles. An international group of architects designs the homes of the future in places diverse as USA, Japan, South America and Europe. These architecture are also challenging the traditional structure of the private house, as we know it. Many of these architects are reinterpreting the private house, challenging traditional notions of what makes house. Here, the interior and exterior surfaces are transformed into 'smart skins', which blur the distinction between the digital and the real and become a part of the daily life of the occupants. The smart house will make possible amazing things we though existed only in science fiction, guarding or welfare, guessing our moods and catering to our demands in music, movies, temperature and ambience. And new materials will further transform our living areas.

  • PDF

Development of Auto Mixing System of High Expansion Foam for Optimal Expansion Performance according to Changing Temperature (고발포 소화약제의 온도 변화에 따른 최적발포성능 유지를 위한 자동혼합시스템 개발)

  • Kim, Ha-Young;Kim, Sung-Soo;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.139-144
    • /
    • 2010
  • Fire fighting foam is expanded when it mix with many water in mechanical method. It have adaptability, mass production possibility, long-time storage possibility. But foam isn't recommended that it use for extinguish the fire in winter. Because of, expansion ratio is changed according to exterior temperature and environment. In this study, we analysis to effect of expansion according to temperature and develop auto mixing system available for fire engine. As a result of non-standard drug mixture is 3.0% up to 30.08% depending on the temperature of the fire showed that the difference in performance occurs. In addition, analysis of the applicability of automatic mixing system design values and actual experimental data as 0.012% maximum error of the applicability of the system obtained according nataname was judged.

A study on the fire resistance method using FR-ECC in long tunnel (고인성내화모르터(FR-ECC)를 사용한 장대터널 내화안전대책에 관한 연구)

  • Kim, Se-Jong;Kim, Dong-Jun;Kwon, Young-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.1
    • /
    • pp.9-18
    • /
    • 2011
  • The spalling phenomenon occurs in high-strength concrete when several factors such as sharp temperature increase, high water content, low water/cement ratio and local stress concentration in material combine in the concrete material. On the basis of the factors, the preventing methods from the spalling are known as reduction of temperature increase, preventing of concrete fragmentation and fast drying of internal moisture. In this study, the reduction of temperature increase was proposed as the most effective spalling-preventing method among the spalling-preventing methods. Engineered cementitious composite for fireproof and repair materials was developed in order to protect the new and existing RC structures form exterior deterioration factors such as fire, cloride ion, etc. This study was carried out to estimate the fire-resisting performance of high strength concrete slab or tunnel lining by repaired engineered cementitious composite (ECC) or fiber reinforcement cemetitious composite (FRCC) under fire temperature curve. and them we will descrike the result of HIDA tunnel in Japan.

An Evaluation of Indoor Thermal Environment for Zero-Carbon Green Home according to the Operation Conditions in Summer (제로카본 그린홈의 여름철 운영조건에 따른 실내 열환경 평가)

  • Yu, Jung yeon;Cho, Dong woo;Kim, Kee Han
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.25-36
    • /
    • 2020
  • The Korean government has a plan to mandate zero-energy buildings in 2020 for public and 2025 for private buildings. In order to design a zero-energy building, insulation and airtightness, which are the most basic elements of passive house technology, are required, and the government has been accomplished this through step-by-step strengthening of related standards. In passive house with high thermal insulation and airtightness performance, the heat introduced into the building through solar radiation can be stored for a long time to keep the inside warm during winter. On the other hand, during summer, heat introduced into the building cannot be easily released to outside, so it is necessary to actively block solar radiation and high temperature outdoor air to prevent an increase of indoor temperature. Therefore, this study aims to derive an appropriate operation condition of passive house to maintain the indoor temperature at an suitable level according to the ventilation methods and solar shading conditions. As a result, under the conditions that the outdoor temperature was 28℃ or less, the ventilation using a heat recovery ventilation system at daytime and natural ventilation at nighttime were selected for the most appropriate operation method. In addition, in the case of solar shading, it was found that blocking solar radiation at daytime using the blind and open the blind at nighttime to ensure natural ventilation were selected for the most appropriate solar shading condition.

The Development of Thermal Model for Safety Analysis on Electronics in High-Speed Vehicle (고속 비행체 전자 장비의 안전성 예측을 위한 열해석 모델 구축)

  • Lee, Jin Gwan;Lee, Min Jung;Hwang, Su Kweon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.5
    • /
    • pp.437-446
    • /
    • 2021
  • As flying vehicle's speed is getting faster, the magnitude of aerodynamic heating is getting bigger. High-speed vehicle's exterior skin is heated to hundreds of degrees, and electrical equipments inside the vehicle are heated, simultaneously. Since allowable temperature of electrical equipments is low, they are vulnerable to effect of aerodynamic heating. These days, lots of techniques are applied to estimate temperature of electrical equipments in flight condition, and to make them thermally safe from heating during flight. In this paper, new model building technique for thermal safety analysis is introduced. To understand internal thermal transient characteristic of electrical equipment, simple heating experiment was held. From the result of experiment, we used our new building technique to build thermal analysis model which reflects thermal transient characteristic of original equipment. This model can provide internal temperature differences of electrical equipment and temperature change of specific unit which is thermally most vulnerable part in the equipment. So, engineers are provided much more detailed thermal analysis data for thermal safety of electrical equipment through this technique.

Effects of Milk Replacer and Ambient Temperature on Growth Performance of 14-Day-Old Early-Weaned Pigs

  • Heo, K.N.;Odle, J.;Oliver, W.;Kim, J.H.;Han, In K.;Jones, E.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.908-913
    • /
    • 1999
  • This experiment was conducted in three trials to evaluate optimal ambient temperature for a novel milk replacer feeding system designed for early-weaned pigs, compared to commercial dry diets fed within a conventional hot nursery. A total of 165 PIC genotype pigs were weaned at $13.89{\pm}0.7$ days of age and allotted to one of two dietary treatments in three trials based on weight and litter origin. Each trial consisted of pigs fed dry diets (DD) and pigs fed milk replacer (MR) which was offered in one of 3 different ambient temperatures. Pigs fed milk replacer were housed in a specialized nursery building in which one half of each pen contained an enclosed hover that was thermostatically maintained at $32^{\circ}C$ while the exterior ambient temperature (where milk was fed) was set at either 17 (trial 1), 24 (trial 2) or $32^{\circ}C$ (trial 3). Pigs fed dry diets with the conventional nursery were maintained at $30^{\circ}C$ for each trial. From d 21 to d 49, all pigs were fed DD within a standardized hot nursery environment. During the first week (d 14-21), pigs fed MR showed increased ADG from 214% to 228% over control pigs fed DD (p<0.001), regardless of ambient temperature. As ambient temperature was increased from 17 to 24 to $32^{\circ}C$, ADG of MR-fed pigs was increased by 214%, 220% and 228% over those of pigs fed DD, respectively. ADFIs of MR-fed pigs at $17^{\circ}C$, $24^{\circ}C$, and $32^{\circ}C$ compared with pigs fed DD were increased by 108%, 139% and 164% from d 14 to d 21, respectively. Fed efficiency (G/F) of MR-fed pigs at $17^{\circ}C$, $24^{\circ}C$, and $32^{\circ}C$ compared with pigs fed DD were 199%, 162% and 139% of those of pigs fed DD, respectively. As ambient temperature increased, diarrhea scores showed a slight tendency to increase. The advantage of MR feeding was greater when the ambient temperature was higher, but G/F was impaired with increased ambient temperature. We conclude that ambient temperature within the specialized nursery influenced behavior, MR feed intake, and probably piglet energy expenditure. There were no differences between MR-fed and DD-fed pigs for ADG, ADFI and G/F in the subsequent growth period (d 21 to d 49, p>0.05). Maximal advantage of MR feeding was obtained at the intermediate ($24^{\circ}C$) ambient temperature during the overall period (p<0.05). Results from this experiment indicate that a milk replacer feeding system utilized in the early postweaning period can maximize pig growth performance, and that ADG, ADFI and G/F were affected by different ambient temperatures within MR-fed pigs. The high or low temperatures could not support the maximal growth of pigs fed MR.

A Study on the Eco-Friendly Durable Pre-Painting for Concrete Structure (콘크리트 구조물의 친환경 내구성 도장에 관한 기초 연구)

  • Jo, Byung Wan;Choi, Ji Sun;Lee, Seong Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2013
  • A concrete structure has become bigger and higher because of development of construction technology and a change in construction environment. Also it tends to focus on repairing, reinforcement and exterior in harmony with environment for structure maintenance and performance improvement. The research is about eco friendly durable painting applicable to concrete structure using civil and architecture. it purpose to improve external beauties and durable problems due to flexibility by variation of temperature, adhesion of exterior wall, crack and delamination in existing organic and mineral painting. For those problems, we made a eco friendly pre-paint that is made with preliminary treatment mixture as a highly enriched waterproof agent and adhesive increasing agent in preprocessing mixture. Then we performed an experiment on durability of prevention neutralization of concrete, durability abrasion, hiding power, adhesion, temperature resistance and resistance to chemical attack. The result of an experiment shows that hiding power is over 0.96 in standard test, durability abrasion test got higher value 1mg than water paint 75mg and tensile strength is 6 times higher than standard waterproof specification.