• Title/Summary/Keyword: Exterior Blind

Search Result 18, Processing Time 0.023 seconds

An Experimental Study on the Effect on Indoor Environment by the Application of the Shading Device in Winter (동계에 차양 적용에 의한 실내 환경 측면의 효과에 관한 실험적 연구)

  • Paik, Joo-Young;Kim, Ji-Hyun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.854-859
    • /
    • 2006
  • This study aims to evaluate the effect on indoor environment by the application of the shading device on winter season. Therefore, thermal and visual experiments were conducted at two side-by-side mock-Lip test cells which were equipped with the shading device(venetian blind & roll blind) at interior and exterior side of the window. The results of this study are as follows: 1) At night of winter, the shading device can prevent internal heat from going out. 2) Exterior shading device is more effective in winter as well as in summer. 3) At daytime of winter, the shading device can provide the uniformity of illuminance, and the interior shading device is more effective.

  • PDF

The Survey Analysis on the Exterior Connection Facility Conditions of University Campuses for Handicapped Students (장애학생을 위한 대학캠퍼스 옥외매개시설의 실태에 관한 조사 분석)

  • Choi, Jang-Soon
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Campus facilities were recently remodeled to provide the substantial learning rights of handicapped students in many campus to embody the dignity and value as man. So this study aims to identify the exterior connection facilities for handicapped students of S and D campuses. The summaries of this research are as follows. Installations of even crossing area(1.5mx1.5m) per 50m and even rest area(1.5mx1.5m) per 30m in walking or access ramp. Improving in accordance with exterior connection facility repairing master plan in S campus. Bringing down an angle degrees of the inclined walking or access ramp in D campus. Installation of exterior braille guide sign for blind students. All handicapped students must be guaranteed the same learning rights as normal men to remove obstacles as the upper mentioned imperfections in using exterior campus facilities.

A Study on Simulation for Decreasing Energy Demand According to Window-to-Wall Ratio and Installation Blind System in Building (블라인드 도입과 창면적비에 따른 표준건축물의 에너지 수요 저감에 대한 시뮬레이션 연구)

  • Kang, Suk-Min;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.531-542
    • /
    • 2018
  • Building energy demands have highly risen in modern society; thus, It is necessary to reduce building energy demands especially commercial buildings adopting a curtain wall architecture. Curtain wall architectures have a high ratio of windows which is a vulnerable in heat insulations as cladding. In order to complement insulation performance of windows in these buildings, there are various methods adopted often such as installing blinds, wing wall and films. There are two suggestions of this paper. 1) WWR (Window-to-Wall Ratio) makes a impaction of energy demands in buildings. 2) Another one is an efficiency of blind systems which are installed in buildings in order to reduce cooling demands. It is also critical to make fundamental model for low-energy building construction by processing a lot of simulation As a result by this study, 1) an external blind system is more useful for reducing cooling energy demands rather than an internal blind system. 2) Buildings which have a large window require more amount of cooling demands. In case of WWR 45%, it needs more cooling energy rather than WWR 15% model's 3) Adopting blind system would reduce energy demands. WWR 45% model with external blind systems reduces about 4% of cooling energy demands compared to same model without any blind systems.4) it is necessary to study an efficiency of blind systems combined with renewable energy and it will be possible to reduce more energy demand in building significantly.

A Study on the Effect of inflow Daylight according to the installation method of controlling Light Shelf and Blind in the Room of General Hospital (종합병원 병실 내 광선반과 블라인드 설치 방식에 따른 자연채광 유입 효과 연구)

  • Cho, Ju Young;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.3-10
    • /
    • 2013
  • This study aims to identify convenient surrounding of the hospital room to be improved by specifically focusing on light environment and to examine a change of inflow of the daylight in the hospital room by using blind and light shelf device as base data of preliminary research for comprehending the relationship between healing environment and natural day light. Simulation analysis on previous facilities and the installation of horizontal light shelf that derives the inflow of day light has been specifically referred by using ECOTECT2011 program. In case of C-facility that mostly adjoined to exterior spaces, it was shown to be closer to a proper uniformity factor when an angle was controlled on the light shelf with blind installed at the same time. However, it was not overall appropriate because of visual displeasure occurred from inflow of much day light. In conclusion, it is the form of flat surface such as H-facility that provides an effect after installing the device to derive day light. Especially, it was shown that interior day light environment was improved when installing blind and controlling the angle at the same time.

Evaluation of the Indoor Thermal Comfort in Naturally Ventilated Apartment During Summer (자연환기가 가능한 서울시 공동주택의 하절기 실내 온열 쾌적성 평가)

  • Lee, Seung-Jae;Cheong, Chang Heon;Hwang, Suckho;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.59-66
    • /
    • 2010
  • Natural ventilation is major strategy of 'sustainable building'. It aims to supply fresh air to the indoor, and to remove heat from the indoor during summer. In the latter point of view, natural ventilation can be grouped into two main strategies, daytime ventilation and night cooing. If we take advantage of these two natural ventilation strategies, indoor thermal comfort can be significantly improved. This study focused on grasping the current situation and problem of indoor thermal comfort of the naturally ventilated residential buildings to seek for direction of later studies. Additionally, thermal comfort of residence where the interior blind and exterior insulation were applied was analyzed. It was analyzed that the percentage of the time which satisfy the indoor acceptable operative temperature during summer was 90 ~ 95% and the heat control performance of natural ventilation has a limitation. When the interior blind and exterior insulation were applied, indoor thermal comfort was significantly improved. However, it still need more improvement.

Light Factor Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 주광조도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 2007
  • This study aims to evaluate the illuminance performance of sloped light guide with automated venetian blind systems. For the purpose, a mock-up model was constructed as a prototype of Korean office building with $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and south facing side-window mounted between the clerestory window($2.0m^2$) and the view window($5.6m^2$). The light guide of 1.28m deepth and $29^{\circ}$ tilted angle, is covered with 0.6mm galvanized steel sheet and 97% reflective film. To protect the room from low solar angle, a blind systems, 0.15m deepth and $30^{\circ}$ automated slat angle was installed. To assess illuminance performance, the totally 37 measuring points for illuminance were monitored. For the detailed analysis, photometric sensors were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point) respectively. The performance was measured under clear sky and is monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons of light factor and uniformity are discussed.

A Study on the Characteristics of Daylighting Environment in Classroom of an School Building Due to the External Shading Devices (학교 건물에서 외부 차양 장치 유형에 따른 일반교실 내 빛환경 특성에 관한 연구)

  • Lim, Jae-Han;Jung, Jin-Ju;Lee, Ji-Young
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.2
    • /
    • pp.4-15
    • /
    • 2008
  • The purpose of this study was to evaluate the characteristics of daylighting environment in classroom of an school building due to the external shading devices such as fixed louvers, light shelves and exterior venetian blinds. In this study, we have made a field research with regard to the facade design in classroom of an school building. And we have made a classification of external shading devices considering the design parameters. Finally, through RADIANCE simulation, we have calculated the spatial distribution of illuminance, uniformity ratio of illuminance and daylight factors. The results of this study will provide the building designer with the basic daylighting performance data at early design stages.

A Case Study on Thermal Performance for Transparent Glazing Space Considering Solar Radiation in Summer (여름철 일사를 고려한 투명 투과체 공간의 열환경 특성에 관한 사례연구)

  • Ryu, Young-Hee;Seo, Hye-Soo;Lee, Min-Jung;Nam, Ji-yeon;Song, Mi-Na;Chun, Chung-Yoon
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.31-36
    • /
    • 2003
  • Recently, buildings with transparent glazing on exterior walls have increased. The transparent glazing on exterior walls gives an impression of opening through introducing external environment's elements to inside of the building, and has various merits and so on, but has defects in controling indoor environments. Especially, the excess of solar radiation in summer increases cooling load causing discomforts to occupants providing radiant environment with high temperature. Cooling load mainly depends on electricity comparing to heating load and intents to centralize specific time. So it is necessary to work out a countermeasure. In this study, showed P building with transparent glazing on exterior walls as a case, investigated indoor thermal performance, numerical analysis of P building in summer through comparing dry-sauna which is represented as radiant environment with high temperature. In the results of this study, transparent glazing space has radiant environment with high temperature such as dry-sauna because of the excess of solar radiation. Accordingly countermeasures are considered in building planning. As concrete methods, there are adiabatic effects using double glazing, use of sunscreen, blind, ventilation facilitation using natural draft, decrease of surface temperature through evaporation cooling and cooling coils.

A Study on the Suitability of Characteristics for Planning of Exterior Pedestrian Spaces in Large-scale Apartment Complexes (대규모 아파트단지 외부보행공간의 계획특성에 관한 적합성 평가 연구)

  • Kwon, So-Young;Ha, Mi-Kyoung
    • KIEAE Journal
    • /
    • v.9 no.6
    • /
    • pp.27-36
    • /
    • 2009
  • Lately construction companies are differentiating the outdoor spaces of apartment complexes to satisfy the needs of residents by providing underground parking area and variety of outdoor community spaces. Building walking networks through residential unit area, the major passage area and the entrance area of the complexes is very important factor to increase the use of the outdoor environment in the complexes. The purpose of this study is to evaluate the characteristics and the elements for the planning of exterior pedestrian spaces carefully through the analysis of current large-scale apartment complexes. In this study, the utilization of space, the connectivity to other spaces and the application of Universal design were evaluated through site visits in 5 large-scale apartment complexes. As a result, the utilization of space is well applied in the most of complexes especially in residential unit area. The connectivity to other spaces has low application compared to the others. Universal design is also well applied except sub criteria for the blind in most of complexes. This study will be able to help in providing better exterior pedestrian environment for residents in apartment complexes.

An Analysis on Building Energy Reduction Effect of Exterior Venetian Blind According to Orientation and Reflectance of Slat (블라인드형 외부차양의 종류 및 반사율에 따른 건물에너지 저감효과 분석)

  • Kim, Jin-Ah;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.28-34
    • /
    • 2013
  • It is essential to reduce building energy consumption in office building because government enact policy which encourages building energy certification from 2013. Office building has high cooling energy demand due to large glazed area of facade in these days. Shading devices can be an alternative of reducing high cooling energy demand. So, this study simulated a variety of exterior venetian blinds to know how much building energy be affected by orientation and reflectance of slat. The results of this study are based on Seoul weather data. The following is a summary of this study. 1) As a slat of venetian blinds has the lower reflectance, the more building energy reduced. Reflectance is usually affected by color and material of slat. In case reflectance is 0.2 reduce 4% of building energy than reflectance is 0.8. 2) Horizontal exterior venetian blinds are more effective than vertical exterior venetian blinds in all of orientation. Horizontal shape is average 16% more effective in shading effect than vertical shape. 3) In this case study, the most effective shading device is low reflectance horizontal exterior venetian blinds that result about 18% building energy reduction than no shade model. The results of this research can be used to plan shading devices for energy conservative office building.