• Title/Summary/Keyword: Exposure marker

Search Result 143, Processing Time 0.022 seconds

Investigation of Air Pollution Exposure and Health Effect Using Passive Sampler (샘플러를 통한 대기오염노출 평가와 건강영향 조사)

  • Lee Jee Na;Xu Quing Song;Leem Jong Han;Choi Ye Yong;Kim Sun Tae
    • Environmental Analysis Health and Toxicology
    • /
    • v.19 no.2
    • /
    • pp.217-225
    • /
    • 2004
  • In order to evaluate a health effect of air pollution, we designed exposure group (taxi driver, street sweeper, street trader,) and non -exposure group (office clerk). We analysed exposure and biologic marker by using personal sampler. Mean NO$_2$ and benzene level in each group were statistically significant. Also, respiratory symptom, chronic cough, sputum, and dyspnea on exertion were statistically significant in each group.

Identification of the Marker-Genes for Dioxin(2, 3, 7, 8- tetradibenzo-p-dioxin)-Induced Immune Dysfunction by Using the High-Density Oligonucleotide Microarray

  • Kim, Jeong-Ah;Lee, Eun-Ju;Chung, In Hye;Kim, Hyung-Lae
    • Genomics & Informatics
    • /
    • v.2 no.2
    • /
    • pp.75-80
    • /
    • 2004
  • In a variety of animal species, the perinatal exposure of experimental animals to the 2,3,7,8-tetrachlorodibenzo­p-dioxin (TCDD) leads to the immune dysfunction, which is more severe and persistent than that caused by adult exposure. We report here the changes of gene expression and the identification of the marker-genes representing the dioxin exposure. The expressions of the transcripts were analyzed using the 11 K oligonucleotide­microarray from the bone marrow cells of male C57BL/6J mice after an intraperitoneal injection of $1{\mu}g$ TCDD/kg body weight at various time intervals: gestational 6.5 day(G6.5), 13.5 day(G13.5), 18.5 day(G18.5), and postnatal 3 (P3W)and 6 week (P6W). The type of self-organizing maps(SOM) representing the specific exposure dioxin could be identified as follows; G6.5D(C14), G13.5D(C0, C5, C10, C18), G18.5D(7): P3W(C2, C21), and P6W(C4, C15, C20). The candidate marker-genes were restricted to the transcripts, which could be consistently expressed greater than $\pm$2-fold in three experiments. The resulting candidates were 85 genes, the characteristics of that were involved in cell physiology and cell functions such as cell proliferation and immune function. We identified the biomarker-genes for dioxin exposure: smc -like 2 from SOM C14 for the dioxin exposure at G6.5D, focal adhesion kinase and 6 other genes from C0, and protein tyrosine phosphatase 4a2 and 3 other genes from C5 for G13.5D, platelet factor 4 from C7 for G18.5D, fos from C2 for P3W.

Use of Nitrogen Dioxide as Exposure Marker of Passive Smiking for Non-smoking Service-workers at Restaurants (음식점 비흡연 종업원의 간접흡연 노출량 지표로써 이산화질소 이용)

  • Won-Ho Yang;Young-Lim Kho;In-Kyu(Paul) Han;Chong-Min Lee;Moon-Shik Zong;Moon-Ho Chung
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.1-7
    • /
    • 2000
  • There is increasing evidence suggestion that passive smoking increases the risk of lung cancer and other disease, though the potential health effects of exposure to environmental tobacco smoke (ETS) is a controversial subject. Since smoking in restaurant is prevalent in Korea, the concern on passive smoking exposure of non-smoking service-workers has been requested. ETS exposure of non-smoking service-workers at restaurant was assessed because they hare spent their times in restaurant indoors. The purpose of this study was feasibility of nitrogen dioxide($NO_2$) as exposure marker of ETS. The results of the study were as follows; 1. Average $NO_2$ concentrations in indoor and outdoor t restaurants were 57.1ppb(${\pm}12.4$) and 54.29ppb(${\pm}9.54$), respectively. Comparing office-workers, service-workers at restaurants were exposured highly. 2. The personal $NO_2$ measurement as exposure marker of ETS could cause the exposure error because $NO_2$ can be generated by combustion appliances in indoor. 3. Service-workers spent their most time(86.6%) in indoor. Mean time spent at restaurant indoors and at home was 9.4 hours and 10.9 hours, respectively. 4. Personal $NO_2$ levels correlated with indoor $NO_2$ concentrations of restaurant (r=0.70) and of their home (r=0.52) rather than of outdoor $NO_2$ concentration of restaurant (r=0.35). The cause of personal $NO_2$ exposure of non-smoking service-workers were considered as smoking of guests and combustion appliance indoors. 5. personal $NO_2$ exposures were estimated using Monte-Carlo simulation and time-weighted model. Estimated personal $NO_2$ level was 47.25ppb(${\pm}8.3$).

  • PDF

Chromium in Erythrocytes as a Biological Marker of Worker Exposed to Hexavalent Chromium (적혈구중 크롬농도를 이용한 6가크롬 노출의 생물학적 지표)

  • Yoon, Ui-Seoung;Kim, Kwang-Jong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.223-234
    • /
    • 2000
  • Objective - To evaluate the usefulness of chromium in erythrocytes as a biological marker of exposure to hexavalent chromium in chromate producers and chrome platers Methods - Blood and urine samples were ramdomly obtained from chromate producers (n=34) and chrome platers (n=35), and non-exposed workers (n=75), chromium level in erythrocytes and plasma, and urine were measured. Different chromium exposure workers were assessed through measurements of airborne hexavalent chromium concentrations using a personal air sampler. Linear associations between variables were evaluated with correlation analysis. Results - The chromate producers had mean chromium levels in erythrocytes five fold as higher than the chrome platers, and fifteen fold higher than non-exposed group. Among the chromium exposed workers, airborne hexavalent chromium was positively and strongly correlated with in erythrocytes (r=0.689, p<0.01), and erythrocytes chromium was inversely correlated with hematocrit (r=-0.441, p<0.01), hemoglobin (r=-0.465, p<0.01) and the number of red blood cells (r=-0.28, p<0.05). Conclusions - In conclusion, this study suggests that chromium in erythrocytes is a good indicator of the chromium body burden caused by exposure to hexavalent chromium.

  • PDF

Effect of Automatic Exposure Control Marker with Chest Radiography in Radiation Reduction (자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과)

  • Jung, Ji-Sang;Choi, Byoung-Wook;Kim, Sung-Ho;Kim, Young-Mo;Shim, Ji-Na;Ahn, Ho-Sik;Jin, Duk-Eun;Lim, Jae-Sik;Kang, Sung-Ho
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.177-185
    • /
    • 2014
  • This study focused on effects of patient exposure dose reduction with AEC (Auto Exposure Control) marker that is designed for showing location of AEC in X-ray Chest radiography. It included 880 adults who have to use Chest X-ray Digital Radiography system (DRS, LISTEM, Korea). AEC (Ion chambers are posited in top of both sides) are used to every adult and set X-ray system as Field size $17{\times}17inch$, 120kVp, FFD 180cm. 440 people of control group are posited on detector to include both sides of lung field and the other 440 people of experimental group are set to contact their lung directly to Ion chamber (making marker to shows location). Then, measured every DAP and, estimated patient effective dose by using PCXMC 2.0. The average age of control group (M:F=245:195) is 53.9 and the average BMI is 23.4. BMI ranges from under weight: 35, normal range: 279, over weight: 106 to obese: 20 and average DAP is 223.56mGycm2, Mean effective dose is 0.045mSv. The average age of experimental group (M:F=197:243) is 53.7 and the average BMI is 22.7. BMI ranges from under weight: 34, normal range: 315, over weight: 85 to obese: 6 and average DAP is 207.36mGycm2, Mean effective dose is 0.041mSv. Experimental group shows less Mean effective dose as 0.004mSv (9.7%) than control group. Also, patient numbers who got over exposure more than 0.056mSv (limit point to know efficiency of AEC marker) is 65 in control group (14.7%), 19 in experimental group (4.3%) and take statistics with t-Test. The statistical difference between two groups is 0.006. In order to use proper amount of X-ray in auto exposure controlled chest X-ray system, matching location between ion chamber and body part is needed, and using AEC marker (designed for showing location of ion chamber) is a way to reduce unnecessary patient exposure dose.

Evaluation of Usability Both Oblique Verification for Inserted Fiducial Marker of Prostate Cancer Patients (Fiducial Marker가 삽입된 전립선암 환자를 대상으로 한 양사방향 촬영의 유용성 평가)

  • Kim, Koon Joo;Lee, Jung Jin;Kim, Sung Gi;Lim, Hyun Sil;Kim, Wan Sun;Kang, Su Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.123-129
    • /
    • 2013
  • Purpose: The way check the movement of the fiducial marker insertion in the treatment of patients with prostate cancer. However the existing methods of fiducial marker verification process difficult to identify the specific location of the marker behind the femur and pelvic bone. So to study the evaluation of maker match with using kilo voltage (KV) X-ray by On-board imager to both oblique verification method. Materials and Methods: Five patients were selected for rectal ballooning and inserted fiducial marker. Compare the position of the fiducial marker of reference plan 2D/2D Anterior/Posterior verification method and 2D/2D both oblique verification method. So to measurement the shift score of X, Y, Z (axis) and measure exposure dose given to patients and compare matching time. Results: 2 dimensional OBI KV X-ray imaging using two-dimensional matching image are orthogonal, so locating fiducial marker matching clear and useful DRR (digital reconstruction radiography) OBI souce angle ($45^{\circ}/315^{\circ}$) matching most useful. 2D/2D both oblique verification method was able to see clearly marker behind the pelvic bone. Also matching time can be reduced accordingly. According to the method of each matching results for each patient in each treatment fraction, X, Y, and Z axis the Mean $value{\pm}SD$ (standard deviation) is X axis (AP/LAT: $0.4{\pm}1.67$, OBLIQUE: $0.4{\pm}1.82$) mm, Y axis (AP/LAT: $0.7{\pm}1.73$, OBLIQUE: $0.2{\pm}1.77$) mm, Z axis (AP/LAT: $0.8{\pm}1.94$, OBLIQUE:$1.5{\pm}2.8$) mm. In addition, the KV X-ray source dose radiation exposure given to the patient taking average when AP/LAT matching is (0.1/2.1) cGY, when $315^{\circ}/45^{\circ}$ matching is (0.27/0.26) cGY. Conclusion: In conclusion for inserted fiducial marker of prostate cancer patients 2D/2D both oblique matching method is more accurate verification than 2D/2D AP/LAT matching method. Also the matching time less than the 2D/2D AP/LAT matching method. Taken as the amount of radiation exposure to patients less than was possible. Suggest would improve the treatment quality of care patients more useful to establish a protocol such as case.

  • PDF

Forensic DNA methylation profiling from evidence material for investigative leads

  • Lee, Hwan Young;Lee, Soong Deok;Shin, Kyoung-Jin
    • BMB Reports
    • /
    • v.49 no.7
    • /
    • pp.359-369
    • /
    • 2016
  • DNA methylation is emerging as an attractive marker providing investigative leads to solve crimes in forensic genetics. The identification of body fluids that utilizes tissue-specific DNA methylation can contribute to solving crimes by predicting activity related to the evidence material. The age estimation based on DNA methylation is expected to reduce the number of potential suspects, when the DNA profile from the evidence does not match with any known person, including those stored in the forensic database. Moreover, the variation in DNA implicates environmental exposure, such as cigarette smoking and alcohol consumption, thereby suggesting the possibility to be used as a marker for predicting the lifestyle of potential suspect. In this review, we describe recent advances in our understanding of DNA methylation variations and the utility of DNA methylation as a forensic marker for advanced investigative leads from evidence materials.

Oxidative Damage in rats by Inhalation Exposure to Hexavalent Chromium (흰쥐의 6가 크롬 흡입폭로에 의한 산화적 손상에 관한 연구)

  • 맹승희;유일재;김현영;임철홍;이용묵;정호근;정해원
    • Environmental Mutagens and Carcinogens
    • /
    • v.22 no.4
    • /
    • pp.279-288
    • /
    • 2002
  • According to the epidemiological studies in chromium workers, hexavalent chromium is associated with the risk of lung cancer. Cellular oxidative damages by reactive oxygen species produced by hexavalent chromium exposure may play an important role in the carcinogenesis process. We investigated the availabilities of malondialdehyde measurement for the assessments of oxidative damages from chromium exposure with an experimental inhalation study in vivo. Lipid peroxidation, one kind of cellular oxidative damage, was measured in blood plasma of the rats which inhaled the hexavalent chromium mist for 1, 2 and 3 weeks. The concentrations of malondialdehyde (MDA), the metabolite of lipid peroxidation, in all exposed groups were higher than those of controls with dose-dependant manner. The levels of MDA were also correlated with urine chromium levels of the rats. Therefore, MDA as an indicator of lipid peroxidation could be proper biologic marker for the assessment of the oxidative damage from chromium exposure, which might be involved in carcinogenesis.

  • PDF

Effects of 915 MHz Radiofrequency Identification Electromagnetic Field Exposure on Neuronal Precursor Cells in the Dentate Gyrus of Adult Rat Brains

  • Kim, Hye Sun;Lee, Yu Hee;Lee, Yun-Sil;Choi, Hyung-Do;Kwon, Jong Hwa;Pack, Jeong-Ki;Kim, Nam;Ahn, Young Hwan
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.173-180
    • /
    • 2015
  • To explore the effects of radiofrequency electromagnetic field on the fate of neuronal cells, we investigated whether exposure to 915 MHz radiofrequency identification (RFID) caused morphological changes in neuronal cells in rat hippocampal dentate gyrus (DG). A reverberation chamber was used as a whole-body RFID exposure system. Rats were assigned to two groups: sham- and RFID-exposed groups. Rats in the RFID-exposed group were exposed to RFID at 4 W/kg specific absorption rate (SAR) for 8 hours daily, 5 days per week, for 2 weeks. Morphological evaluation of DG was performed using immunohistochemistry with doublecortin (DCX) as a neuronal precursor cell marker and neuronal nuclei (NeuN) as a mature neuronal cell marker. No significant morphological changes in DCX+ or NeuN+ cells in the DG of RFID-exposed rats were observed. These results suggest that RFID exposure induces no significant change in DCX+ neuronal precursor or NeuN+ neuronal cells in DG of rats.

Assessment of the Glycophorin A Mutant Assay as a Biologic Marker for Low Dose Radiation Exposure (저선량 방사선 노출에 대한 생물학적 지표로서 Glycophorin A 변이발현율 측정의 유용성 평가)

  • Ha, Mi-Na;Yoo, Keun-Young;Ha, Sung-Whan;Kim, Dong-Hyun;Cho, Soo-Hun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.33 no.2
    • /
    • pp.165-173
    • /
    • 2000
  • Objectives : To assess the availability of the glycophorin A (GPA) assay to detect the biological effect of ionizing radiation in workers exposed to low-doses of radiation. Methods : Information on confounding factors, such as age and cigarette smoking was obtained on 144 nuclear power plant workers and 32 hospital workers, by a self-administered questionnaire. Information on physical exposure levels was obtained from the registries of radiation exposure monitoring and control at each facility. The GPA mutant assay was performed using the BR6 method with modification by using a FACScan flow cytometer. Results : As confounders, age and cigarette smoking habits showed increasing trends with GPA variants, but these were of no statistical significance. Hospital workers showed a higher frequency of the GPA variant than nuclear power plant workers in terms of the NO variant. Significant dose-response relationships were obtained from in simple and multiple linear regression models. The slope of the regression equation for nuclear power plant workers was much smaller than that of hospital workers. These findings suggest that there may be apparent dose-rate effects. Conclusion : In population exposed to chronic low-dose radiation, the GPA assay has a potential to be used as an effective biologic marker for assessing the bone marrow cumulative exposure dose.

  • PDF