• Title/Summary/Keyword: Exposure dose rate

Search Result 377, Processing Time 0.023 seconds

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

A Study on the Application of Two-dosimeter Algorithm to Estimate the Effective Dose in an Inhomogeneous Radiation Field at Korean Nuclear Power Plants (원전 불균일 방사선장하에서 유효선량 평가를 위한 복수선량계 알고리즘 적용방안 연구)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.4
    • /
    • pp.151-160
    • /
    • 2008
  • In Korean nuclear power plants (NPPs), two thermoluminescent dosimeters (TLD) were provided to workers who work in an inhomogeneous radiation field; one on the chest and the other on the head. In this way, the effective dose for radiation workers at NPPs was determined by the high deep dose between two radiation dose from these TLDs. This represented a conservative method of evaluating the degree of exposure to radiation. In this study, to prevent the overestimation of the effective dose, field application experiments were implemented using two-dosimeter algorithms developed by several international institutes for the selection of an optimal algorithm. The algorithms used by the Canadian Ontario Power Generation (OPG) and American ANSI HPS N13.41, NCRP (55/50), NCRP (70/30), EPRI (NRC), Lakslumanan, and Kim (Texas A&M University) were extensively analyzed as two-dosimeter algorithms. In particular, three additional TLDs were provided to radiation workers who wore them on the head, chest, and back during maintenance periods, and the measured value were analyzed. The results found no significant differences among the calculated effective doses, apart from Lakshmanan's algorithm. Thus, this paper recommends the NCRP(55/50) algorithm as an optimal two-dosimeter algorithm in consideration of the solid technical background of NCRP and the convenience of radiation works. In addition, it was determined that a two-dosimeter is provided to a single task which is expected to produce a dose rate of more than 1 mSv/hr, a difference of dose rates depending on specific parts of the body of more than 30%, and an exposure dose of more than 2 mSv.

Clonal plant as experimental organisms - DNA mutation rate evaluation in the radiation contaminated area of Fukushima Daiichi NPP accident

  • KANEKO, Shingo
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.10a
    • /
    • pp.25-25
    • /
    • 2018
  • The Fukushima Daiichi Nuclear Power Plant accident in March 2011 caused severe radioactive contamination in the surrounding environment. Since the accident, much attention has been paid to the biological and genetic consequences of organism inhabiting the contaminated area. The effect of radiation exposure on genetic mutation rates is little known, especially for low doses and in situ conditions. Evaluating DNA mutation by low levels of radiation dose is difficult due to the rare mutation event and lack of sequence information before the accident. In this study, correlations with air dose levels and somatic DNA mutation rates were evaluated using Next Generation Sequencer for the clonal plant, Phyllostachys edulis. This bamboo is known to spread an identical clone throughout Japan, and it has the advantage that we can compare genetic mutation rate among identical clone growing different air dose levels. We collected 94 samples of P. edulis from 14 sites with air dose rates from $0.04{\sim}7.80{\mu}Gy/h$. Their clonal identity was confirmed by analysis using 24 microsatellite markers, and then, sequences among samples were compared by MIG sequence. The sequence data were obtained from 2,718 loci. About ~200,000 bp sequence (80 bp X 2,718 loci) were obtained for each sample, and this corresponds to about 0.01% of the genome sequence of P. edulis. In these sequences, 442 loci showed polymorphism patterns including recent origin mutation, old mutation, and sequence errors. The number of mutations per sample ranged from 0 to 13, and did not correlate with air dose levels. This result indicated that DNA mutations have not accumulated in P. edulis living in the air doses levels less than $10{\mu}Gy/h$. Our study also suggests that mutation rates can be assessed by selecting an appropriate experimental approach and analyzing with next generation sequencer.

  • PDF

Evaluation of Occupational, Facility and Environmental Radiological Data From the Centralized Radioactive Waste Management Facility in Accra, Ghana

  • Gustav Gbeddy;Yaw Adjei-Kyereme;Eric T. Glover;Eric Akortia;Paul Essel;Abdallah M.A. Dawood;Evans Ameho;Emmanuel Aberikae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.3
    • /
    • pp.371-381
    • /
    • 2023
  • Evaluating the effectiveness of the radiation protection measures deployed at the Centralized Radioactive Waste Management Facility in Ghana is pivotal to guaranteeing the safety of personnel, public and the environment, thus the need for this study. RadiagemTM 2000 was used in measuring the dose rate of the facility whilst the personal radiation exposure of the personnel from 2011 to 2022 was measured from the thermoluminescent dosimeter badges using Harshaw 6600 Plus Automated TLD Reader. The decay store containing scrap metals from dismantled disused sealed radioactive sources (DSRS), and low-level wastes measured the highest dose rate of 1.06 ± 0.92 µSv·h-1. The range of the mean annual average personnel dose equivalent is 0.41-2.07 mSv. The annual effective doses are below the ICRP limit of 20 mSv. From the multivariate principal component analysis biplot, all the personal dose equivalent formed a cluster, and the cluster is mostly influenced by the radiological data from the outer wall surface of the facility where no DSRS are stored. The personal dose equivalents are not primarily due to the radiation exposures of staff during operations with DSRS at the facility but can be attributed to environmental radiation, thus the current radiation protection measures at the Facility can be deemed as effective.

Application plan for radiological exposure model using virtual reality-based radiological exercise system

  • Lee, Dewhey;Lee, Byung Il;Park, Younwon;Kim, Dohyung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.5
    • /
    • pp.745-750
    • /
    • 2018
  • New exercise technology such as the virtual reality (VR)-based exercise system is required to meet soaring demand for target participants in exercises and to alleviate the difficulties in personnel mobilization through an alternative approach to the exercise system. In a previous study, event tree methodologies were introduced in setting up an exercise scenario of a VR-based radiological exercise system. In the scenario, the locations at which major events occur are rephrased as nodes, routes as paths, and public response actions as protective actions or contents of an exercise at individual locations. In the study, a model for estimating effective doses to the participants is proposed to evaluate the exercise system, using the effective dose rates at particular times and locations derived from a computer program. The effective dose received by a student when she/he follows a successful route is about a half of the dose received when she/he does not follow the exercise guide directions. In addition, elapsed time to finish an exercise when following a successful route is less than one-third of the time spent to finish an exercise when following the guide's directions.

A Study on HEMT Device Process (Part I. Lift-off Process for the Metallization) (HEMT 소자 공정 연구 (Part 1. 금속박막 형성을 위한 Lift-off 공정연구))

  • 이종람;박성호;김진섭;마동성
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.10
    • /
    • pp.1535-1544
    • /
    • 1989
  • The overhang structure of photoresist in optical lithography was studied for the metallization of GaAs-related devices throughout lift-off method. Optical contact aligner with a dose of 8.5 m J/cm\ulcornerand with a wavelength of 300mm was used for ultraviolet exposure of single layer of S1400-27 photoresist. The overhang thickness shows a linear relationship with the soaking time in monochlorobenzene, which its magnitude becomes high at elevated softbake temperature. Such process conditions as a low softbake temperature, a long monochlorohbenzene soaking time and a little exposed energy make the development rate of photoresist lower. The optimum process conditions to obtain a target line-width, which include an appropriate overhang structure such as complete separation between the sidewall of photoresist pattern and the deposited metal edge, are determined as the softbake temperature of 64-74\ulcornerC, the monochlorobenzene soaking time of 10-15min, the ultraviolet exposure time of 70-100sec and the development time of 50-80sec.

  • PDF

Central Axis Percentage Depth-Dose in a Water Phantom Irradiated by Conventional X-rays (Water Phantom 속 Conventional X-ray 중심축상의 깊이 선량 백분율)

  • Kim, Wuon-Shik;Hah, Suck-Ho;Hwang, Sun-Tae;Oh, Jang-Jin;Jun, Jae-Shik
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 1987
  • Central axis percentage depth-doses, P(%), were measured at the points from the 2.5cm depth of reference point to 20 cm depth with 2.5 cm interval. Distance from the X-ray target to the water phantom($30{\times}30{\times}30cm^3$) surface was 1 m, and at this point three different beam sizes of $5cm{\phi},\;10cm{\phi},\;and\;15cm{\phi}$ were used. While the X-ray tube voltage varied from 150 to 250 kV, the tube current remained constant at 5 mA. Absorbed dose rate in water, $\dot{D}_w$, was determined using the air kerma calibration factor, $N_k$, which was derived from the exposure calibration factor, $N_x$, of the NE 2571 ion chamber. The reference exposure rate, $\dot{X}_c$, was measured using the Exradin A-2 ion chamber calibrated at ETL, Japan. The half value layers of the X-rays determined to meet ETL calibration qualities. The absorbed dose rates determined at the calibration point were compared to the values obtained from Burlin's general cavity theory, and the percentage depth-dose values determined from $N_k$ showed a good agreement with the values of the published depth dose data(BJR Suppl. 17).

  • PDF

Hepatic Expression of Cu/Zn-Superoxide Dismutase Transcripts in Response to Acute Metal Exposure and Heat Stress in Hemibarbus mylodon (Teleostei: Cypriniformes)

  • Cho, Young-Sun;Bang, In-Chul;Lee, Il-Ro;Nam, Yoon-Kwon
    • Fisheries and Aquatic Sciences
    • /
    • v.12 no.3
    • /
    • pp.179-184
    • /
    • 2009
  • Hemibarbus mylodon (Cypriniformes) is an endemic freshwater fish species in the Korean peninsula, for which urgent conservation efforts are needed. To understand their stress responses in relation to metal toxicity and thermal elevation, we performed a real-time RT-PCR-based expression assay of hepatic copper/zinc-superoxide dismutase (Cu/Zn-SOD), a key antioxidant enzyme, in response to experimental heavy metal exposure or heat treatment. The transcription of hepatic Cu/Zn-SOD was differentially modulated by acute exposure to Cu, cadmium (Cd), or Zn. Exposure to each metal at $5{\mu}M$ for 24 h revealed that Cu stimulated the mRNA expression of Cu/Zn-SOD to a greater extent than the other two heavy metals. The elevation in Cu/Zn-SOD transcripts in response to Cu exposure was dose-dependent (0.5 to $5{\mu}M$). Time course analysis of Cu/Zn-SOD expression in response to Cd exposure ($5{\mu}M$) revealed a transient pattern up to day 7. Exposure to thermal stress (an increase from 22 to $30^{\circ}C$ at a rate of $1^{\circ}C/h$ followed by $30^{\circ}C$ for 18 h) did not significantly alter SOD transcription, although heat shock protein 90 kDa (HSP90) transcription was positively correlated with an increase in temperature.

The Effects on Antioxidants for Improving to Radiation Resistance of LDPE (저밀도 폴리에틸렌의 내방사선성 향상을 위한 산화방지제 첨가효과)

  • Kim, Ki-Yup;Kim, Pyeong-Jong;Lee, Chung;Kim, Jin-Ah;Ryu, Boo-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.457-460
    • /
    • 2004
  • Many of the physical and chemical properties of polymer materials can be altered by high energy radiation. In the present work the exposure to radiation of low density polyethylene(LDPE) included antioxidants was carried out at various doses up to 600kGy at a dose rate of 5kGy/hr in the presence of air at room temperature. The study of the irradiation effects on the material properties has been make by different methods in an integrated way. The experimental data indicate that the decomposition onset temperature(DOT), the crystallinity and the thermoluminescence(TL) with radiation dose. DOT, crystallinity and TL analysis from irradiated PE samples provides useful data for the characterization of radiation-induced oxidation effects on these samples.

  • PDF

Toxicity Assessment of Phenanthrene using the Survival and Population Growth Rate of the Marine Rotifer, Brachionus plicatilis (해산로티퍼(Brachionus plicatilis)의 생존 및 개체군 성장률을 이용한 Phenanthrene의 독성평가)

  • Hwang, Un-Ki;Choi, Hoon;Jang, Soo-Jung;Heo, Seung;Lee, Ju-Wook
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.573-580
    • /
    • 2017
  • The oxicity assesment of Phenanthrene (PHE) has been investigated by using the rate (r) of survival and population growth in rotifer Brachionus plicatilis. The survival rate was determined after 24 h of exposure to PHE. The survival rate of PHE had no effect at a maximum of $300mg\;L^{-1}$. The r was determined after 72 h of exposure to PHE. It was observed that r in the controls (absence PHE) was greater than 0.5, but that it suddenly decreased with an increased concentration of PHE. PHE reduced r in a dose-dependent manner and a significant reduction occurred at a concentration of greater than $37.5mg\;L^{-1}$. The $EC_{50}$ value of r in PHE exposure was $63.7mg\;L^{-1}$. The no-observed-effect-concentration (NOEC) of r in PHE exposure was $18.8mg\;L^{-1}$. The lowest-observed-effect-concentration (LOEC) of r in the PHE exposure was $37.5mg\;L^{-1}$. From the results, the concentration of PHE (greater than $37.5mg\;L^{-1}$) has a toxic effect on the r of B. plicatilis in natural ecosystems. These results(including NOEC, LOEC and $EC_{50}$) might be useful for the Polycyclic aromatic hydrocarbons(PAHs) toxicity assessment in marine ecosystems.