• Title/Summary/Keyword: Exposed time

Search Result 2,604, Processing Time 0.041 seconds

Prediction of Long-Term Interlaminar Shear Strength of Carbon Fiber/Epoxy Composites Exposed to Environmental Factors (환경인자에 노출된 탄소섬유/에폭시 복합재의 장기 층간전단강도 예측)

  • Yoon, Sung Ho;Shi, Ya Long
    • Composites Research
    • /
    • v.30 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • The purpose of this study was to predict the long-term performance using the interlaminar shear strength of carbon fiber/epoxy composites exposed to environmental factors. Interlaminar shear specimens, manufactured by the filament winding method, were exposed to the conditions of drying at $50^{\circ}C$, $70^{\circ}C$, and $100^{\circ}C$ and of immersion at $25^{\circ}C$, $50^{\circ}C$, and $70^{\circ}C$ for up to 3000 hours, respectively. According to the results, the interlaminar shear strength did not vary significantly with the exposure time for the drying at $50^{\circ}C$ and $70^{\circ}C$, but it increased somewhat for the drying at $100^{\circ}C$ due to the post curing as the exposure time increased. The interlaminar shear strength of the specimens exposed to the immersion at $25^{\circ}C$ did not change significantly at the beginning of exposure, but it decreased with the exposure time and the degree of decrease increased as the environmental temperature increased. The linear regression equations for the environmental temperatures were obtained from the interlaminar shear strength of the specimens exposed to the immersion for up to 3000 hours. Using these linear regression equations, the interlaminar shear strength was estimated to be within 5.5% of the measured value at $25^{\circ}C$ and $50^{\circ}C$, and 2.3% of the measured value at $70^{\circ}C$. Therefore, the proposed performance prediction procedures can predict well the long-term interlaminar shear strength of carbon fiber/epoxy composites exposed to environmental factors.

Detection of DNA Damage in Carp Using Single-Cell Gel Electrophoresis Assay for Genotoxicity Monitoring

  • Jin, Hai-Hong;Lee, Jae-Hyung;Hyun, Chang-Kee
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.268-275
    • /
    • 2004
  • To investigate the potential application of the single-cell gel electrophoresis (SCGE) assay to carp as an aquatic pollution monitoring technique, gill, liver, and blood cells were isolated from carp exposed to a direct-acting mutagen, N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), or indirect mutagen, $benzo[\alpha]pyrene$ $(B[\alpha]P)$, then the DNA strand breakage was analyzed using the assay. Based on testing 5 different cell isolation methods and 6 electrophoretic conditions, the optimized assay conditions were found to be cell isolation by filter pressing and electrophoresis at a lower voltage and longer running time (at 0.4 V/cm for 40 min). In preliminary experiments, gill and liver cells isolated from carp exposed to MNNG in vitro exhibited DNA damage signals even with 0.5 ppb exposure, which is a much higher dose than previously reported. In the gill cells isolated from carp exposed to 0.01-0.5 ppm MNNG in vivo, significant dose-and time-dependent increases were observed in the tail for 4 days. As such, the linear correlation between the relative damage index (RDI) values and time for each dose based on the initial 48-h exposure appeared to provide effective criteria for the genotoxicity monitoring of direct-acting mutagenic pollution. In contrast, the in vivo exposure of carp to 0.25-1.0 ppm of $B[\alpha]P$ for 7 days resulted in dose-and time-dependent responses in the liver cells, in which 24-h delayed responses for metabolizing activation and gradual repair after 48 h were also observed. Thus, the negative-sloped linear correlation between the RDI and time at each dose based on the initial 48 h appeared to provide more effective criteria for the genotoxicity monitoring of indirect mutagenic pollution.

Time-dependent buckling analysis of SiO2 nanoparticles reinforced concrete columns exposed to fire

  • Bidgoli, M. Rabani;Saeidifar, M.
    • Computers and Concrete
    • /
    • v.20 no.2
    • /
    • pp.119-127
    • /
    • 2017
  • Time-dependent buckling of embedded straight concrete columns armed with Silicon dioxide($SiO_2$) nano-particles exposed to fire is investigated in the present study for the fire time. The column is simulated mathematically with Timoshenko beam model. The governing mass conservation equations to describe heat and moisture transport in concrete containing free water, water vapor, and dry air in conjunction with the conversion of energy are considered. The characteristics of the equivalent composite are determined using Mori-Tanaka approach. The foundation around the column is simulated with spring and shear layer. Employing nonlinear strains-displacements, energy methods and Hamilton's principal, the governing equations are derived. Differential quadrature method (DQM) is used in order to obtain the critical buckling load and critical buckling time of structure. The influences of volume percent of $SiO_2nano-particles$, geometrical parameters, elastic foundation and concrete porosity are investigated on the time-dependent buckling behaviours of structure. Numerical results indicate that reinforcing the concrete column with $SiO_2nano-particles$, the structure becomes stiffer and the critical buckling load and time increase.

Oxygen Toxicity: Behavioral Assessment by Swim Test in Mouse Exposed to Hypoxia and Hyperoxia (수영 시험 모델에서 산소 농도에 따른 운동성 변화와 독성 평가)

  • 김동희;강문철;김재일;이근호;김광열;김형건
    • Toxicological Research
    • /
    • v.19 no.2
    • /
    • pp.99-104
    • /
    • 2003
  • This study was aimed to evaluate the effect of oxygen on motor activity and toxicity in male mice. The modified Porsolt forced swim test (FST) was used and the distance and time of movement by mice were analyzed in 15。C water bath for 20 minutes using the automatic Ethovision videotracking system. Analyses were carried out before and after 20 minutes of exposure to 10%-70% concentration of normobaric oxygen. The effects of inspired oxygen tension on the distance and time of movement showed the similar trends, but changes in distance were more prominent. Both the distance and time of movement increased after exposure to 30% and 40% oxygen concentration. The distance and time of movement also increased upon exposure to 50% and 60% oxygen. In contrast, increases En movement and time under exposure to 21% oxygen concentration were suppressed when exposed to over 50% oxygen concentration. With exposure to 10% oxygen, there was a significant decrease in the distance of movement and a slight suppression of movement time. During the swim test, 12.5%, 37.5%, and 87.5% of the mice drowned after exposure to 10%, 60%, and 70% oxygen concentration, respectively. These results suggest that motor activity can be enhanced by inspired oxygen up to 40% concentration. When hypoxic and hyperoxic oxygen exposure over 50%, motor activity is reduced and toxicity may be induced.

Study of Nanoparticle Effect on Durability of Carbon fiber/Epoxy Resin Composites in Moisture Environment (수분환경에서 탄소섬유강화 에폭시수지의 내구성에 대한 나노입자의 영향)

  • Ahn, Seok-Hwan;Choi, Young-Min;Moon, Chang-Kwon
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.43-49
    • /
    • 2014
  • This study has been investigated on the durability of carbon fiber/epoxy composites (CFRP) in moisture environment. The carbon fiber/epoxy composites were modified to use the nanoparticles such as carbon nanotubes and titanium oxide. These hybrid composites were exposed to moisture environment for a certain period of time. Weight gain according to immersion time, quasi-static tensile test and micro-graphic characterization were investigated on the samples exposed to moisture environment. Consequently, the weight gains increased with increasing immersion time and weight gain of the hybrid composites was lower than the one of CFRP through the whole immersion time. The tensile strengths decreased with increasing immersion time and tensile strengths of the hybrid composites were higher than the one of CFRP through the whole immersion time. The CFRP were observed more degraded than hybrid compositess in moisture environment. Therefore, it was concluded that the addition of nanoparticles in CFRP could lead to improve the durability in moisture environment.

Measurement dose of Dental Panoramagraphy using a Radiophotoluminescent Glass Rod Detector (유리선량계를 이용한 파노라마 검사의 피폭선량 측정)

  • Kim, Chang-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2624-2628
    • /
    • 2011
  • Exposed dose of a patient was measured by Radiophotoluminescent Glass Rod Detector with a use of a panorama graphic device in dental examination. The effect of exposed dose in optic lens was measured by comparing the different materials of the glasses. Depending on the dental location, the exposed dose distribution was 82.4~2,340uSv. It showed that the maximum difference in dose distribution was over 300%. Thus, when manufacturing the devices, it seemed to require shortening the pre-heat time and additional shielding in order to control the diagnosis and exposed dose. The measurement data of the exposed dose in optic lens was increased 20~75uSv per each test when compared putting on glasses with not wearing. As a result, taking off the glasses is recommended to improve efficiency of the test and minimize the exposed dose during dental panorama graphic examinations.

Carpal Tunnel Syndrome among workers in a condom industry (한 콘돔공장근로자들의 수근관증후군에 관한 연구)

  • Kang, Joong-Koo;Paek, Do-Myung;Lee, Young-Jung;Ma, Hyeo-Il;Son, Mi-A;Lee, Hong-Ki;Choi, Jung-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.507-519
    • /
    • 1996
  • The objectives of this study are to investigate the prevalence of occupation related carpal tunnel syndrome(CTS) among workers in a condom industry : to analyse the sensitivity and specificity of clinical signs or symptoms such as hand diagram, Tinel's sign and Phalen's sign in carpal tunnel syndrome : and to test vibration threshold test using audiometry as a technically easy and noninvasive method in the diagnosis of carpal tunnel syndrome in stead of nerve conduction velocity (NCV). The study group was divided into exposed group(39 cases) and non-exposed group(48 cases) based on whether or not excessive use of wrist movements exsist. 1. There are stastically significant differences in symptoms and signs of carpal tunnel syndrome such as hand diagram, Tinel's sign and Phalen's sign between exposed and non-exposed group(p<0.05). 2. Six cases(9 hands) were comfirmed as carpal tunnel syndrome by NCV. Five cases(7 hands) belonged to exposed group, 1 case(2 hands) to nonexposed group. As there are significant differences in prevalence of carpal tunnel syndrome between two groups(p<0.05), excessive use of wrist in occupation is a risk factor of carpal tunnel syndrome. 3. When we use NCV as a gold standard in the diagnosis of carpal tunnel syndrome, sensitivity and specificity of hand diagram, Tinel's sign and Phalen's sign is as followed; hand diagram , sensitivity 88.9%, specificity 84.2% Tinel's sign ; sensitivity 55.6%, specificity 72.8% Phalen's sign ; sensitivity 14.3%, specificity 88.4%. Among above clinical signs and symptoms, hand diagram is the best clinical screening test. 4. The differences of vibration threshold between median and ulnar nerve at the same time are useful in the diagnosis of carpal tunnel syndrome but the time change of vibration threshold of median nerve over time are not sensitive enough. It is concluded that vibration threshold between median and ulnar nerve at the same time can be used as a supplementary or alternative criterion to indicate that the nerve dysfunction is located in the carpal tunnel.

  • PDF

A New Algorithm for K Shortest Paths Problem (복수최단경로의 새로운 최적해법)

  • 장병만
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.3
    • /
    • pp.79-94
    • /
    • 2001
  • This paper presents a new algorithm for the K shortest paths Problem which develops initial K shortest paths, and repeat to expose hidden shortest paths with dual approach and to replace the longest path in the present K paths. The initial solution comprises K shortest paths among shortest paths to traverse each arc in a Double Shortest Arborescence which is made from bidirectional Dijkstra algorithm. When a crossing node that have two or more inward arcs is found at least three time by turns in this K shortest paths, there may be some hidden paths which are shorter than present k-th path. To expose a hidden shortest path, one inward arc of this crossing node is chose by means of minimum detouring distance calculated with dual variables, and then the hidden shortest path is exposed with joining a detouring subpath from source to this inward arc and a spur of a feasible path from this crossing node to sink. If this exposed path is shorter than the k-th path, the exposed path replaces the k-th path. This algorithm requires worst case time complexity of O(Kn$^2$), and O(n$^2$) in the case k$\leq$3.

  • PDF

Pore Structure of Cement Matrix Exposed to High Temperatures (고온하의 시멘트 경화체의 공극구조)

  • 송훈;도정윤;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.509-512
    • /
    • 2003
  • Dehydration and micro crack thermal expansion occur in cement hydrates of concrete structure heated by fire for a long time. The characteristic of concrete exposed to high temperature can be analyzed from distribution of porosity and pore size. Porosity showed a tendency to increase irrespective of specimen types. This is due to both the outbreak of collapse of gel comprising the cement and a micro crack by heating. Porosity did not affect the variety of specimen and increased with the same tendency throughout every specimen. In addition, the deteriorate of compressive strength resulted from increase in porosity

  • PDF

An experimental study on the human upright standing posture exposed to longitudinal vibration

  • Shin, Young-Kyun;Arif Muhammad;Inooka Hikaru
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.77.2-77
    • /
    • 2002
  • Human upright standing posture in the sagittal plane is studied, when it exposed in the antero-posterior vibration. A two link inverted pendulum model is considered and described its functional behavior in terms of ankle and hip joint according to the dominant joints that provides the largest contribution to the corresponding human reactionary motion. The data is analyzed, both in the time domain and the frequency domain. Subjects behave as a non-rigid pendulum with a mass and a spring throughout the whole period of the platform motion. When vision was allowed, each segment of body shows more stabilized.

  • PDF