Hazard Evaluation of Runaway Reaction in Deboronation Process Using H2O2 in DIET Synthesis of Pharmaceutical Raw Material (의약품 원료 DIET 합성 중 H2O2를 이용한 붕소제거 반응공정에서의 폭주반응 위험성 평가)

  • Kim, Won Sung;Lee, Keun Won
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.49-54
    • /
    • 2018
  • In the Active Pharmaceutical Ingredient(API) manufacturing company, since the product is produced by the chemical reaction, fire and explosion are frequently occurred in the process of inputting the raw powder as the chemical reaction stage. There are not many studies on safety measures through analysis of cause of accident in the actual chemical reaction stage. In this study, we investigated the heat flow in the boron removal reaction process to investigate the risk in the chemical reaction stage. The study reaction process was performed by using the reaction calorimeter for the products synthesized at the actual raw material in pharmaceutical factory. The risk was estimated by comparing the maximum temperature of the synthesis reaction, which can generate heat due to the failure of cooling in the actual manufacturing process, and the technical temperature. These results are applied to commercial manufacturing sites and safety measures to control the risk of runaway reaction due to reaction heat are suggested.

A Study on Accident Frequency by Installing Safety Devices in the LPG Heating and Drying Furnace (LPG 가열로 및 건조로의 안전장치 설치에 따른 사고빈도에 관한 연구)

  • Song, Dong-Woo;Kim, Ki-Sung;Kim, Choong-Hee;Lee, Seong-Gueong;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.49-54
    • /
    • 2015
  • The purpose of this study is to assess the risk of depending on the presence or absence of safety device of domestic heating and drying furnaces, by derivation and analysis of accident frequency of safety devices through FTA (Fault Tree Analysis). Installation standards are lacking in Korean for the safety device of LPG heating and drying furnace, which have a risk of explosion due to structure to trap the leaked gas. Four different safety devices were selected on the basis of NFPA and national standards for combustors of other equipment. Effects of frequency reduction in accidents were analyzed before and after installing the safety devices respectively. As a result, a minimal leakage safety device was presented for preventing damages from gas leak of domestic LPG heating and drying furnace.

A Quantitative Risk Analysis of LPG Leaked During Cylinder Delivery (가스용기 운반 중 누출된 LPG의 정량적 위험 분석)

  • Kim B-J,;Park Ki-Chang;Lee Kuen-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.33-41
    • /
    • 2003
  • There exists high hazard when transporting LPG as well as using, storing, and producing. For small scale LPG consumer, retailers deliver LPG to customers via a truck loading many LPG cylinders. Suppose there occurred a accident during LPG cylinder transfer, this could result in serious damages to the life and properties in the near or neighbor of the accident spot. In this regard, we made a quantitative risk analysis to estimate the possible damages and the probability through the identification of accidents causes and the simulation of the possible scenario. In this study, we made the Excel & Visual Basic computer program to perform quantitative LPG accident analysis. The simulation showed the following results. In case of UVCE(Unconfined Vapor Cloud Explosion), the effect within l0m of the accident spot showed very severe structural damages and even the accident can break the window glasses of the area of 150 m apart from accident spot. In case of TNT corresponding probit analysis, after 10 minutes LPG leaking, $75\%$ window glasses of 40 m distance was expected to be broken. And $16\%$ frames of 20m distance, $10\%$ frames of 40m distance was expected to be collapsed.

  • PDF

A Numerical Study on Ventilation Characteristics of Factors Affecting Leakages in Hydrogen Ventilation (누출 수소 환기에 영향을 미치는 요인별 환기 특성에 관한 수치해석적 연구)

  • Lee, Chang-Yong;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.610-619
    • /
    • 2022
  • Hydrogen is emerging as an alternative fuel for eco-friendly ships because it reacts with oxygen to produce electrical energy and only water as a by-product. However, unlike regular fossil fuels, hydrogen has a material with a high risk of explosion due to its low ignition point and high flammability range. In order to safely use hydrogen in ships, it is an essential task to study the flow characteristics of hydrogen leakage and diffusion need to be studied. In this study, a numerical analysis was performed on the effect of leakage, ventilation, etc. on ventilation performance when hydrogen leaks in an enclosed space such as inside a ship. ANSYS CFX ver 18.1, a commercial CFD software, was used for numerical analysis. The leakage rate was changed to 1 q, 2 q, and 3 q at 1 q = 1 g/s, the ventilation rate was changed to 1 Q, 2 Q and 3 Q at 1 Q = 0.91 m/s, and the ventilation method was changed to type I, type II, type III to analyze the ventilation performance was analyzed. As the amount of leakage increased from 1 q to 3 q, the HMF in the storage room was about 2.4 to 3.0 times higher. Furthermore, the amount of ventilation to reduce the risk of explosion should be at least 2 Q, and it was established that type III was the most suitable method for the formation of negative pressure inside the hydrogen tank storage room.

ANALYSTS OF DAMAGE PROBABILITY FOR COLLISION BETWEEN SPACE DEBRIS AND A SATELLITE IN LOW-EARTH ORBIT (우주파편에 의한 저궤도 위성의 손상확률 분석)

  • Lee, Jae-Eun;Park, Sang-Young;Kim, Young-Rok;Choi, Kyu-Hong;Kim, Eung-Hyun;Kim, Gyu-Sun
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.2
    • /
    • pp.135-144
    • /
    • 2007
  • Space environment becomes more hazardous for satellite because of increasing number of space debris. This research is to analyze collision hazards between KOMPSAT 3 in low-earth orbit and space debris generated by the explosion of FengYun satellite on the January 11, 2007. Based on the observed data of the space debris from FengYun satellite, the mass and number distribution of the debris are estimated including undetectable debris from the explosion of FengYun satellite. The spatial density and flux for the space debris can be calculated according to size. This study also brings out the analysis for the assessment of collision probability and damage probability. The algorithm developed in the current paper can be used to estimate the level of risk due to space debris for the satellites that will be launched in the future.

A Study on Damge Effect from Boiling Liquid Expanding Vapor Explosion(BLEVE) of LPG Charging Facility (LPG 충전소의 BLEVE 현상에 따른 피해효과 분석)

  • Roh Sam-Kew;Kim Tae-Hwan;Ham Eun-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.3 s.8
    • /
    • pp.45-50
    • /
    • 1999
  • The LPG refueling station's explosion at Bucheon city was a major accident which with rare frequency of occurrence and large damage effect. Therefore, to prevent similar accident in the future from LPG charging stations which located in urban area. It needs to identify the damage effects of such facilities by comparing theoretically quantities risk and actual damage. The BLEVE effects from the accident showed similar damage effect in case of heat flux, however, the overpressure level reflected at the reduced distance by $15\%$. The structure damage to the near by area showed comparatively large heat radiation damage to the concrete structure strength and shape changes through heat flux while the overpressure effect was small.

  • PDF

A Study on the Calculation of Minimum Safety Distance during Storage and Combustion Test of Solid Propellants for Launch Vehicles (발사체 고체추진제의 저장 및 시험 시 안전거리 산정에 관한 연구)

  • Shin, Ahn-Tae;Park, Byung-Mun;Byun, Hun-Soo
    • Korean Chemical Engineering Research
    • /
    • v.59 no.2
    • /
    • pp.180-185
    • /
    • 2021
  • In accordance with the revision of the US-Korea missile guidelines, restrictions on the use of solid propellants for space launch vehicles have been completely lifted. The solid propellant can be used as a solid propellant rocket like the KSR-1 (Korea Sounding Rocket-1), and can also be used as a thrust augmentation booster for liquid fuel launch vehicles. It is known that solid propellants have a lower risk of explosion than liquid propellants. but if an accident such as an explosion at the Alcantara Launch Center in Brazil occurs, it can lead to a large-scale personal accident. In order to prevent such large-scale accidents, it is necessary to review and reflect the minimum safety distance during use, storage and combustion test of solid propellants from the planning phase of the project. In this paper, the minimum safety distance for safe use of the solid propellant is presented by dividing it into storage facilities and combustion tests.

A Study on Quantitative Risk Analysis & Model Application for Hydrogen Filling Center (수소충전시설에 대한 정량적 위험성 평가 및 모델적용에 관한 연구)

  • Shin, Jung-Soo;Byun, Hun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.87-101
    • /
    • 2012
  • In gas industries, the potential risks of serious accidents have been increased due to high technology application and process complexities. Especially, in case of gas-related accidents, the extent of demage is out of control since gas plants handle and produce combustible, flammable, explosive and toxic materials in large amounts. The characteristics of this kind of disaster is that accident frequency is low, while the impact of damage is high, extending to the neighboring residents, environment and related industries as well as employees involved. The hydrogen gases treated important things and it used the basic material of chemical plants and industries. Since 2000, this gas stood in the spotlight the substitution energy for reduction of the global warming in particular however it need to compress high pressure(more than 150 bar.g) and store by using the special cylinders due to their low molecular weight. And this gas led to many times the fire and explosion due to leak of it. To reduce these kinds of risks and accidents, it is necessary to improve the new safety management system through a risk management after technically evaluating potential hazards in this process. This study is to carry out the quantitative risk assesment for hydrogen filling plant which are very dangerous(fire and explosive) and using a basic materials of general industries. As a results of this risk assessment, identified the elements important for safety(EIS) and suggested the practical management tools and verified the reliability of this risk assessment model through case study of accident.

Numerical analyses for the structural assessment of steel buildings under explosions

  • Olmati, Pierluigi;Petrini, Francesco;Bontempi, Franco
    • Structural Engineering and Mechanics
    • /
    • v.45 no.6
    • /
    • pp.803-819
    • /
    • 2013
  • This paper addresses two main issues relevant to the structural assessment of buildings subjected to explosions. The first issue regards the robustness evaluation of steel frame structures: a procedure is provided for computing "robustness curves" and it is applied to a 20-storey steel frame building, describing the residual strength of the (blast) damaged structure under different local damage levels. The second issue regards the precise evaluation of blast pressures acting on structural elements using Computational Fluid Dynamic (CFD) techniques. This last aspect is treated with particular reference to gas explosions, focusing on some critical parameters (room congestion, failure of non-structural walls and ignition point location) which influence the development of the explosion. From the analyses, it can be deduced that, at least for the examined cases, the obtained robustness curves provide a suitable tool that can be used for risk management and assessment purposes. Moreover, the variation of relevant CFD analysis outcomes (e.g., pressure) due to the variation of the analysis parameters is found to be significant.

Study on the Fire Safety Estimation for a Pilot LNG Storage Tank (PILOT LNG저장탱크의 화재안전성 평가에 관한 연구)

  • 고재선;김효
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.57-73
    • /
    • 2004
  • Quantitative safety analysis through a fault tree method has been conducted for a fire broken out over the spilling LNG from a pilot LNG tank, which may have 4 types of scenarios causing potentially risky results. When we consider LNG release from venting pipelines as a first event, any specific radius of Low Flammable Limit(LFL) has not been built up. The second case of LNG outflow from the rupture of storage tank which will be the severest has been analyzed and the results revealed various diffusion areas to the leaking times even with the same amount of LNG release. As a third case LNG leakage from the inlet/outlet pipelines was taken into consider. The results showed no significant differences of LFL radii between the two spilling times of 10 and 60 minutes. Hence, we have known the most affecting factor on the third scenario is an initial amount of LNG release. Finally, the extent of LFL was calculated when LNG pipelines around the dike area were damaged. In addition, consequence analysis has been also performed to acquire the heat radiation and flame magnitude for each case.