• Title/Summary/Keyword: Explosion accidents

Search Result 304, Processing Time 0.05 seconds

A Study on Prevention of Explosion Accidents by Complex Treatment Methods in Semiconductor Exhaust Process (반도체 배기 공정에서 복합 처리 방식으로 인한 폭발 사고 예방대책에 관한 연구)

  • Choi, Se Wook;Lee, Dae Joon;Kim, Sang Ryung;Kim, Sang Gil;Jeong, Jeong Hee;Yang, Won Baek
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.5
    • /
    • pp.28-34
    • /
    • 2022
  • Since semiconductor factories are located in densely populated areas, safe handling of hazardous materials handled in the manufacturing process is of utmost importance. In particular, the types of hazardous substances discharged after handling in the semiconductor manufacturing process are very diverse, and the treatment methods such as combustion, absorption and adsorption methods for each material are very complicated. Therefore, in recent semiconductor exhaust treatment processes, two or more treatment methods are applied to one treatment facility, and unexpected accidents occur due to the application of such a complex treatment method. In this study, the cause of accidents in treatment facilities that applied both the scrubber method and the electrostatic precipitation method, which are recent accident cases, are identified, and preventive measures are suggested to find out the points to be noted when applying the complex treatment method.

Optimization of Gas Detector Location by Analysis of the Dispersion Model of Hazardous Chemicals (유해화학물질의 확산 모델 분석을 통한 가스감지기 위치 최적화)

  • Jeong, Taejun;Lim, Dong-Hui;Kim, Min-Seop;Lee, Jae-Geol;Yoo, Byung Tae;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.39-48
    • /
    • 2022
  • The domestic gas detector installation standards applied to gas detectors, which are one of the facilities that can prevent accidents such as fire, explosion, and leakage that can cause serious industrial accidents, do not take into account the behavioral characteristics of hazardous chemicals in the atmosphere. It can be seen that the technical basis is insufficient because the standard is applied. Therefore, in this study, the size of the leak hole for each facility mainly used in chemical plants and the diffusion distance according to the concentration of interest of hazardous chemicals were analyzed, and based on this, the optimal installation distance for gas detectors for each material was suggested. Using the method presented in this study, more economical and effective gas detector installation can be expected, and furthermore, it can be expected to help prevent serious industrial accidents.

A Study on Regulation Improvement of Local Ventilation System (국소배기장치의 규제개선에 관한 연구)

  • kim, Nam Suk;Kim, Young Suk;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.74-83
    • /
    • 2018
  • Anyone who wants to install local ventilation system must obtain a permission from the Ministry of Employment and Labor even if he has permission from the Ministry of Environment. This is because not only the Atmospheric Environmental Protection Act, but also the manufacturing industry's hazardous risk prevention plan under Article 48 Clause 2 of the Industrial Safety and Health Act is to be submitted by 15 days before the construction. Under the current Environmental Protection Act, the Ministry of Environment regulates only the emission of pollutants from local exhaust ventilation systems into the atmosphere and the contents of workers' safety and health within industrial sites are managed by the Ministry of Employment and Labor. Even with the approval of the Ministry of Environment, the number of unsuccessful cases by the Ministry of Employment and Labor has increased, causing a growing discontent among the sites due to production delays and additional costs of improvement. In addition, local exhaust systems that are at greater risk of fire explosion have increased the risk of severe industrial accidents due to fire explosion. This is due to insufficient design of air volume, control speed, return speed, duct size, and risk of fire explosion. This is because the criteria and procedures for approval of local exhaust ventilation systems are similar, but the Industrial Safety and Health Act adds additional screening items for safety and safety of workers and fire and explosion. In this study, the Environment Ministry and the Employment and Labor Ministry seek to find a reasonable way to operate the system by comparing local exhaust ventilation system installation approval standards.

A Study on the Prevention Measures against Fire and Explosion Accidents during Splash Filling in Batch Process (회분식 공정에서 스플래쉬 필링(Splash Filling) 작업으로 인한 화재·폭발 사고 예방대책에 관한 연구)

  • Kim, Sang Ryung;Lee, Dae Jun;Kim, Jung Duk;Kim, Sang Gil;Yang, Won Baek;Rhim, Jong Guk
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.3
    • /
    • pp.33-39
    • /
    • 2020
  • In general, in a batch reaction process in which products are made using flammable liquids, splash filling is used to clean the walls of the reactor by spraying flammable liquids, which are raw materials used for product, during cleaning of the reactor after work. During this process, mist of flammable liquid is generated, the lower limit of explosion is lowered, and fire·explosion may occur due to discharges caused by various types of complex charges, such as flow charge, collision charge, and ejection charge. Therefore, based on the recent accident case, to identify the risk when working in the form of splash filling with toluene in a batch process and perform an explosion impact analysis using the TNT equivalent method After that, we will analyze the accident results and suggest preventive measures such as constant purge system, improvement of cleaning method, and use of tantalum to prevent such accident.

Study on Disaster Prevention System for Long Span Bridge over the Sea (장대해상교량의 방재시스템 구축에 관한 연구)

  • Kong, Byung-Seung
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.59-64
    • /
    • 2009
  • Bridge types such as the suspension bridges and the cable stayed bridges maintained by cables present the dangerous possibility of a ship running through the bottom of the bridge. Due to hangers and main cables in the upper structural system, the bridge is also susceptible to disasters. However, these cable bridges are usually used for long span bridges over the sea. This structure is relatively more exposed to disasters, such as wind, hail, and earthquake, than other structures. This structure also has the potential to cause car accidents on account of the poor visibility due to foggy conditions. If a fire breaks out because of a car accident due to wind, a car explosion will likely occur.

A Study on development of repeat check system for product (제품 검사 시스템 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.3
    • /
    • pp.156-161
    • /
    • 2013
  • Gas valve time control system used to set the time to use the gas system by one of the user's negligence explosion, fire, and to prevent accidents such as suffocation. Gas valve is one of the items is not a replacement without any special issue after installation in each customer. So sufficient test is required prior to the installation device. In this study, the test system was developed to use to set the number of times at the gas valve time control system.

A Study on Estimation and Management of Loss Due to Catastrophic Accident (화학공장의 중대사고에 따른 예상손실액 산정 및 대책연구)

  • 구남주;엄성인;고재욱
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.4
    • /
    • pp.120-125
    • /
    • 1999
  • This study evaluated the effect of the accidents caused by fire, explosion, and toxic gas release by using SuperChems, quantitative hazardous material release modeling software, which estimates the potential area of damage. According to the loss severity, the appropriate risk management principles can be applied. Risk management is divided into the two methods which are risk control and risk financing. Risk control includes risk avoidance, risk spreading and diversification, and risk reduction. Risk financing includes risk retention and risk transfer. The results of this study can help the related company determine the appropriate reserve fund and the amount to be insured against the third party losses according to the estimated loss severity.

  • PDF

Time to ignition analysis of AP composite propellant induced by thermal loading (열 하중에 의한 AP 추진제의 발화특성 연구)

  • Kim, Ki-Hong;Lee, Kyung-Cheol;Gwak, Min-Cheol;Kim, Yong-Hyeon;Doh, Young-Dae;Kim, Chang-Kee;Yoo, Ji-Chang;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.207-210
    • /
    • 2009
  • The AP/HTPB composite propellant is a common choice for solid rocket propulsion. The externally heated rocket via fires, for instance, can cause the energetic substance to ignite, and this may lead to a thermal runaway event marked by a severe explosion. In order to develop preventive measures to reduce the possibility of such accidents in propulsion systems, we investigate the ignition and initiation properties of AP/HTPB propellant.

  • PDF

The Field Test of a Mitigation Method from DC Subwaysystem for Underground Pipeline

  • Bae, Jeong-Hyo;Ha, Tae-Hyun;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Corrosion Science and Technology
    • /
    • v.6 no.6
    • /
    • pp.308-310
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP are described.

The Study about The Minimum Ignition Energy for Electrostatic Discharge in The Gasoline-air Mixture (정전기 방전에 의한 개소린-공기혼합기체의 최소착화에너지에 관한 연구)

  • 황명환;이덕출
    • Fire Science and Engineering
    • /
    • v.10 no.1
    • /
    • pp.3-9
    • /
    • 1996
  • Electrostatic charge is generated in large scale or high speed processes dealing with materials with large resistance, or under complicated condition. Fire and explosion often occur due to electrostatic charge accumulated in flammable gases, vapor, liquids and powder. It is usually very difficult to verify the cause of accidents as well as the prevention. In this study, it is shown that the needle electrode needs the electrode gap from 1.8mm to 3.8mm, sphere electrode and plate electrodes need the electrode gap of 1.9mmfor the minimum ignition energy. The sphere electrode and the plate electrode requires 12.8mJ and 3.2mJ of minimum ignition energy respectively with the electrode gap of 1.1mm. The ignition voltage rises to very large value as the ground resistance increases.

  • PDF