• 제목/요약/키워드: Experimental verification

Search Result 1,663, Processing Time 0.026 seconds

Reliability Verification of the Clothing Pressure Meter Utilizing the Arduino Board (아두이노 활용 의복압 측정기 제작 및 신뢰도 검증)

  • Kim, Nam Yim;Park, Gin Ah
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.5
    • /
    • pp.723-740
    • /
    • 2022
  • This study aimed to develop an Arduino-based garment pressure device (APD) on the basis of using Single-Tact sensor by suggesting the reliable clothing pressure range and coefficient of selected sensors through the APD calibration process. Once the APD was validated, the pressure of the experimental men's lower body compression wears was measured using the APD and was compared to the pressure measured using the existing air-pack type pressure meter. The subjects were one mannequin and eight men in their 20's, and the trial compression wears were calf sleeves and pants. Clothing pressures were measured in hip, mid-thigh, calf, and ankle. In terms of the 99% confidence level, the experimental clothing pressure measured at the designated measuring points using the APD was considered identical to the one measured using an existing clothing pressure meter. Therefore, on the basis of the experiment results, this study demonstrated that the APD is as reliable as the existing clothing pressure meter within the pressure ranges of 0.54-16.79 kPa and 0.18-25.47 kPa as provided by the SingleTact sensor supplier's data on the basis of using an external ADC (Analog to Digital Converter) module.

Experimental Verification of Spur Gear Pump based on FEM Analysis (FEM해석 기반 스퍼기어 펌프의 실험적 검증에 대한 연구)

  • Lee, Chan-Woo;Kim, Sang-Yu;Lee, Seo-Han;Kim, Jae-Yeol;Lim, Jin-Hyuk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.6
    • /
    • pp.1-7
    • /
    • 2022
  • This work investigated the performance improvement of a medium-pressure fixed-displacement-type SPUR gear pump, which is mainly used in the machine tool industry. The 3D CFX analysis and IS technique were applied using ANSYS (commercial FEM code) and compared with experimental results to ensure the reliability of the analysis. In addition, the performance improvement of the pump was obtained using the theoretical volumetric displacement equation, and the gear tooth width was changed. The pressure flow performance curves were compared, and the results were analyzed according to the width of the gear teeth. This is a factor that can cause irregular flow, vibration, and noise inside the gear pump owing to friction between the housing and gear pump.

Research on Thermal Refocusing System of High-resolution Space Camera

  • Li, Weiyan;Lv, Qunbo;Wang, Jianwei;Zhao, Na;Tan, Zheng;Pei, Linlin
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.69-78
    • /
    • 2022
  • A high-resolution camera is a precise optical system. Its vibrations during transportation and launch, together with changes in temperature and gravity field in orbit, lead to different degrees of defocus of the camera. Thermal refocusing is one of the solutions to the problems related to in-orbit defocusing, but there are few relevant thermal refocusing mathematical models for systematic analysis and research. Therefore, to further research thermal refocusing systems by using the development of a high-resolution micro-nano satellite (CX6-02) super-resolution camera as an example, we established a thermal refocusing mathematical model based on the thermal elasticity theory on the basis of the secondary mirror position. The detailed design of the thermal refocusing system was carried out under the guidance of the mathematical model. Through optical-mechanical-thermal integration analysis and Zernike polynomial calculation, we found that the data error obtained was about 1%, and deformation in the secondary mirror surface conformed to the optical index, indicating the accuracy and reliability of the thermal refocusing mathematical model. In the final ground test, the thermal vacuum experimental verification data and in-orbit imaging results showed that the thermal refocusing system is consistent with the experimental data, and the performance is stable, which provides theoretical and technical support for the future development of a thermal refocusing space camera.

An Analytical & experimental study on the thermal performance of trickle solar collector with Sinuous Cross-section (파형 단면을 가진 유하식 집열기의 열적 성능에 대한 이론 및 실험 연구(I))

  • Lee Jong Ho;Chung Mo;Baek Nam Choon;Auh Chungmoo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.12 no.4
    • /
    • pp.240-251
    • /
    • 1983
  • The municipal government of Daejeon, Korea set up a plan to retrofit solar energy to the existing swimming pool. The pool was constructed in 1980, and meets the requirements of International standard. It will be used for the 1986 Asian Games and the 1988 Seoul Olymipics. The roof structure of the existing pool is to be modified to accomodate trickle solar collectors. In addition, various energy conserving ideas will be applied to the existing building structure. For the prevention of over heating of collectors on the roof, natural air convection scheme will be adopted within the collector system. Natural convection of passive type heating would be also adopted for the space heating of the pool when the system is idle. At present, the pool can be utilized only for two months a year without auxilairy heating. With oil heating, the energy cost would be too high for the normal operation. When this project completed in March 1984, it would be expected to be openable for seven months a year without a significan amount of auxiliary heating. In this project, two dimensional numerical analysis technic have been used to analyse the characterisitics of thermal performance of the swimming pool system. An experimental tat verification of the theoretical analysis have been also attempted.

  • PDF

Simulating large scale structural members by using Buckingham theorem: Case study

  • Muaid A. Shhatha
    • Advances in Computational Design
    • /
    • v.8 no.2
    • /
    • pp.133-145
    • /
    • 2023
  • Scaling and similitude large scale structural member to small scale model is considered the most important matter for the experimental tests because of the difficulty in controlling, lack of capacities and expenses, furthermore that most of MSc and PhD students suffering from choosing the suitable specimen before starting their experimental study. The current study adopts to take large scale slab with opening as a case study of structural member where the slab is squared with central squared opening, the boundary condition is fixed from all sides, the load represents by four concentrated force in four corners of opening, as well as, the study adopts Buckingham theorem which has been used for scaling, all the parameters of the problem have been formed in dimensionless groups, the main groups have been connected by a relations, those relations are represented by force, maximum stress and maximum displacement. Finite element method by ANSYS R18.1 has been used for analyzing and forming relations for the large scale member. Prediction analysis has been computed for three small scale models by depending on the formed relations of the large scale member. It is found that Buckingham theorem is considered suitable way for creating relations among the parameters for any structural problem then making similitude and scaling the large scale members to small scale members. Finally, verification between the prediction and theoretical results has been done, it is observed that the maximum deviation between them is not more than 2.4%.

A Numerical Study on Tsunami Run-up Heights on Impermeable/Permeable Slope (투과성 및 불투과성 경사면 상에서 지진해일의 처오름 높이에 관한 수치적 검토)

  • Lee, Woo-Dong;Hur, Dong-Soo;Goo, Nam-Heon
    • Journal of Coastal Disaster Prevention
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • In order to examine the characteristics of tsunami run-up heights on impermeable/permeable slope, a numerical wave tank by upgrading LES-WASS-3D was used in this study. Then, the model were compared with existing hydraulic model test for its verification. The numerical results well reproduced experimental results of solitary wave deformation, propagation and run-up height under various conditions. Also, the numerical simulation with a slope boundary condition has been carried out to understand solitary wave run-up on impermeable/permeable slope. It is shown that the run-up heights on permeable slope is 52.64-63.2% smaller than those on the impermeable slope because of wave energy dissipation inside the porous media. In addition, it is revealed that the numerical results with slope boundary condition agreed well with experimental results in comparison with the results by using stair type boundary condition.

Experimental Study of In-situ Production of Precast Concrete Members

  • Lim, Jeeyoung;Son, Seunghyun;Kim, Jeong Tai;Kim, Sunkuk
    • International conference on construction engineering and project management
    • /
    • 2017.10a
    • /
    • pp.263-270
    • /
    • 2017
  • The precast concrete (PC) structure has been preferred for reasons of shortening the construction time and securing the quality and, in particular, it has a cost saving effect in case of long span and heavy loaded structure with high floor height. Most engineers take it for granted to install the plant produced PC members. Researchers in several papers have argued that slander PC members such as columns and girders can be cost-effective if in-situ production is possible, while ensuring quality equal to or better than in-plant production. However, this argument is not officially accepted because objective verification has not been done. Therefore, the purpose of this study is to experimentally conduct in-situ production of PC members to verify the above claim. For this study, a storage building with long span and heavy loaded structure with high floor height was selected as a case study site. For the site, most of the PC members were supplied from the plant, and some of the columns were produced in the site for this study. As a result, it has been confirmed that it has a cost saving effect of 20% while having superior quality to plant-produced PC columns.

  • PDF

Measurement and Verification of Unfrozen Water Retention Curve of Frozen Sandy Soil Based on Pore Water Salinity (간극수 염분농도에 따른 동결 사질토의 부동수분곡선 산정 및 검증 연구)

  • Kim, Hee-Won;Go, Gyu-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.11
    • /
    • pp.53-62
    • /
    • 2023
  • The characteristics of unfrozen water content in frozen soils significantly impact the thermal, hydraulic, and mechanical behavior of the ground. A thorough analysis of the unfrozen water content characteristics of the target subsoil material is crucial for evaluating the stability of frozen ground. This study conducted indoor experiments to measure the freezing point and unfrozen water content of sandy soil while considering pore water salinity. Utilizing the experimental data, we introduced a novel empirical model to conveniently estimate the unfrozen water retention curve. Furthermore, the validity of the unfrozen water retention curve was assessed by comparing the experimental data with the results of a simulation model that utilized the proposed empirical model as input data.

Research on prediction and analysis of supercritical water heat transfer coefficient based on support vector machine

  • Ma Dongliang;Li Yi;Zhou Tao;Huang Yanping
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4102-4111
    • /
    • 2023
  • In order to better perform thermal hydraulic calculation and analysis of supercritical water reactor, based on the experimental data of supercritical water, the model training and predictive analysis of the heat transfer coefficient of supercritical water were carried out by using the support vector machine (SVM) algorithm. The changes in the prediction accuracy of the supercritical water heat transfer coefficient are analyzed by the changes of the regularization penalty parameter C, the slack variable epsilon and the Gaussian kernel function parameter gamma. The predicted value of the SVM model obtained after parameter optimization and the actual experimental test data are analyzed for data verification. The research results show that: the normalization of the data has a great influence on the prediction results. The slack variable has a relatively small influence on the accuracy change range of the predicted heat transfer coefficient. The change of gamma has the greatest impact on the accuracy of the heat transfer coefficient. Compared with the calculation results of traditional empirical formula methods, the trained algorithm model using SVM has smaller average error and standard deviations. Using the SVM trained algorithm model, the heat transfer coefficient of supercritical water can be effectively predicted and analyzed.

Electronically tunable compact inductance simulator with experimental verification

  • Kapil Bhardwaj;Mayank Srivastava;Anand Kumar;Ramendra Singh;Worapong Tangsrirat
    • ETRI Journal
    • /
    • v.46 no.3
    • /
    • pp.550-563
    • /
    • 2024
  • A novel inductance simulation circuit employing only two dual-output voltage-differencing buffered amplifiers (DO-VDBAs) and a single capacitance (grounded) is proposed in this paper. The reported configuration is a purely resistor-less realization that provides electronically controllable realized inductance through biasing quantities of DO-VDBAs and does not rely on any constraints related to matched values of parameters. This structure exhibits excellent behavior under the influence of tracking errors in DO-VDBAs and does not exhibit instability at high frequencies. The simple and compact metal-oxide semiconductor (MOS) implementation of the DO-VDBAs (eight MOS per DO-VDBA) and adoption of grounded capacitance make the proposed circuit suitable for on-chip realization from the perspective of chip area consumption. The function of the pure grounded inductance is validated through high pass/bandpass filtering applications. To test the proposed design, simulations were performed in the PSPICE environment. Experimental validation was also conducted using the integrated circuit CA3080 and operational amplifier LF-356.