• Title/Summary/Keyword: Experimental instrument

Search Result 471, Processing Time 0.03 seconds

Effects of the Self-care Promotion Program for the Elderly in Home Health Nursing (재가노인을 위한 자가관리증진 프로그램의 효과)

  • Lee, Kyung Bok;Kim, Soon-Lae
    • Journal of Home Health Care Nursing
    • /
    • v.21 no.2
    • /
    • pp.156-165
    • /
    • 2014
  • Purpose: This study aimed to investigate the effects of a program for increasing self-care with activities of daily living among the elderly living at home. Methods: The study adopted a non-equivalent control group pretest-posttest design. The number of participants were 30 in the experimental group and 30 in the control group. Participants were persons aged 65 years and above in Busan. The experimental group was provided with for 16 different types of self-care behaviors by family nurses who made weekly home visits to these participants. Each visit lasted for more than 30 minutes, and the visits were conducted for 12 weeks. The research instrument used in this study was a scale developed by Shimanouchi et al. (2003) which assessed self-care behavior, activities of daily living, and depression. Results: The experimental group showed an increase in self-care behavior compared to the control group. Time and group variables were also found to have an interaction effect on the daily living activity level. The experimental group showed an increase in the activities of daily living compared to the control group. Depression scores dropped from 9.4 to 5.8 in the experimental group and from 8.6 to 7.0 in the control group. Conclusion: We found that the self-care behavior program improved the levels of independence and activities of daily living among the elderly living at home.

Effect of Massage Therapy on Growth Parameters of Instituted Infants (마사지 요법이 시설 영아의 신체성장에 미치는 영향)

  • Kim, Tae-Im
    • Child Health Nursing Research
    • /
    • v.8 no.2
    • /
    • pp.204-216
    • /
    • 2002
  • The purpose of this study was to investigate the effect of massage therapy on weight gain, length and head circumference in instituted infants. This study utilized nonequivalent control group with repeated measuring by quasi experimental design. Fifty eight instituted infants in Daejeon city were selected for the study. Fifty eight infants were randomly assigned two groups, one served as the control group and the other was experimental group to whom massage therapy was given. For the experimental group, massage protocol(developed by Field, 1986) was applied 2 times a day, mid-morning and early evening, for 4 weeks for each infants by researcher and trained research assistants. As a weight weighing instrument, electronic indicator scale (Cas Co., Korea) was used. The result of this study were summarized as follows; 1.A repeated measures ANOVA identified a significant group by time effect over the four weeks of intervention(F=14.69, p < .0001). Infants assigned to experimental group gained more weight than control group infants. 2. T-test identified that significant differences in length(t=2.60, P=.013) and head circumference(t=4.27, P=.000). Infants assigned to experimental group had more length and head circumference than control group infants. In conclusion, Massage therapy improved weight gain, length and head circumference of instituted infants. Therefore, it is recommended to utilize massage therapy as a nursing intervention for instituted infants.

  • PDF

Compositional analysis by NIRS diode array instrumentation on forage harvesters

  • Andreashaeusler, Michael Rode;Christian, Paul
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1619-1619
    • /
    • 2001
  • Ourwork aims to assess the content of dry matter, protein, cell wall parameters and water soluble carbohydrates in forages without having to handle samples, transport them to a laboratory, dry, grind and chemically analyze them. for this purpose, the concept of fresh forage analysis under field conditions by means of compact integrated NIRS InGaAs-diode array instruments on small plot harvesters is being evaluated for plant breeding trials. This work was performed with the world first commercial experimental forage plot harvester equipped with a NIRS module for the collection, compression, and scanning of forage samples (including automatic referencing and dark current measure ments). It was used for harvesting and analyzing a number of typical forage grass and forage legume plot trials. After NIRS measurements in the field each sample was again analyzed in the laboratory by means of a conventional grating spectrometer equipped with Si-and PbS-detectors. Conventional laboratory analysis of the samples was restricted to dry matter (DM) content by means of oven drying at 105. Routine chemometric procedures were then employed to assess the comparative accuracy and precision of the DM assessments in the spectral range between 950 and 1650nm by the NIRS diode array as well as by the conventional NIRS scanning instrument. The results of this study confirmed that the type of NIRS diode array instrument employed here functioned well even in rugged field operations. further refinements proved to be necessary for optimizing the automatic filling of the sample compartment to adjust for the wide variation in forage material under conditions of extremely low or high harvest yields. The error achieved in calibrating the apparatus for forages of typical DM content proved to be satisfactory (SECV < 1.0). Possibly as a consequence of higher sampling errors, its performance in atypical forages with elevated DM contents was less satisfactory. The error level obtained on the conventional grating NIR spectrometer was similar to that of the diode array instrument for both types of forage.

  • PDF

Effect of Feedrate and Specimen Shape on Cutting Force and Surface Roughness of Ultrasonic Dental Surgical Instrument (치과용 초음파 수술기의 이송속도 및 시편형상이 절삭반력과 표면거칠기에 미치는 영향)

  • Sang Ho Kim;Seung Han Yang;Joong Ho Lee;Jong Kyun Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.109-117
    • /
    • 2023
  • In this study, the effect of the shape of the specimen and the feedrate of the dental ultrasonic surgical instrument on the cutting force and surface roughness of the specimen is analyzed. Experimental specimens were made of SAWBONES artificial bone materials in square and spherical specimens. In addition, the cutting feedrate of the surgical instrument was controlled through the developed moving system. The cutting force generated when cutting the specimen was measured through a force sensor. After the experiment, the cutting surface of the specimen was observed through a three-dimensional optical microscope and the surface roughness was measured. Through one-way ANOVA, the effect of each specimen shape and feed rate on surface roughness was analyzed. As a result of the experiment, the cutting force increased proportionally in the initial feed rate increase stage, but the increase in cutting force decreased as the feed rate continued to increase. Also, the cutting force showed a difference according to the shape of the specimen. The spherical specimen with a relatively small cutting surface area had less cutting force than the square specimen. However, as a result of one-way ANOVA, it was found that the specimen shape and feed rate did not affect the surface roughness. In future studies, it is expected to be used for comparative analysis of ultrasonic surgical instruments and correlation analysis between cutting factors.

Development of a Multi - channel Detector for Capillary Electrophoresis System (모세관 전기영동 장치용 Photodiode Array 다채널 검출기의 개발에 관한 연구)

  • Hong, Seung Guk;Kim, Hai-Dong
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.96-104
    • /
    • 1998
  • A photodiode array multichannel detector system for capillary electrophoresis was developed. The photodiode array detector for capillary electrophoresis (CE-PDA) has 1024 photodetectors and can analyze sample by measuring UV/VIS absorption spectrum in 275~675 nm wavelength range. The CE-PDA instrument can get a spectrum in 30 ms during sample separation and can be programmed by a PC to control various experimental conditions required for sample analysis. The performance of the multichannel CE-PDA instrument was tested using L-ascorbic acid and alizarin yellow GG mixture. The reproducibility test of the CE-PDA system showed 5.6% RSD.

  • PDF

On the Test of the reliability and validity of the Disabled's Motivation Scale for Rehabilitation (장애인의 재활동기 측정도구의 신뢰도 및 타당도 검정 연구)

  • Han, Hye-Sook;Lim, Nan-Young
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.5 no.2
    • /
    • pp.124-133
    • /
    • 2002
  • Purpose: to test of the reliability and validity of the Disabled's Motivation for Rehabilitation Scale, which was developed in 2002. Method: An experimental version of the scale was distributed to a sample of 441 disabled with ages above 18 and below 80 years. The subjects of the test-retest were 60 disabled. Results: revealed a satisfactory level of test-retest and internal consistency. The overall fit of the factor model to the data was good. Correlation among the subscales revealed a simple pattern that, in general, provides support for the self-determination continuum and the construct validity. In testing concurrent, criterion-validity, there was a positive correlation between the motivation scores for rehabilitation and the Health-Related Hardiness scores and a negative correlation between the motivation scores for rehabilitation and the Learned Helplessness scores. Conclusion: The Disabled's Motivation for Rehabilitation Scale revealed a useful instrument with a high degree of reliability and validity. In this sense, this instrument can be effectively utilized in rehabilitative nursing for the disabled.

  • PDF

Effect of $Ga^+$ Ion Beam Irradiation On the Wet Etching Characteristic of Self-Assembled Monolayer ($Ga^+$ 이온 빔 조사량에 따른 자기 조립 단분자막의 습식에칭 특성)

  • Noh Dong-Sun;Kim Dea-Eun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.326-329
    • /
    • 2005
  • As a flexible method to fabricate sub-micrometer patterns, Focused Ion Beam (FIB) instrument and Self-Assembled Monolayer (SAM) resist are introduced in this work. FIB instrument is known to be a very precise processing machine that is able to fabricate micro-scale structures or patterns, and SAM is known as a good etch resistance resist material. If SAM is applied as a resist in FIB processing fur fabricating nano-scale patterns, there will be much benefit. For instance, low energy ion beam is only needed for machining SAM material selectively, since ultra thin SAM is very sensitive to $Ga^+$ ion beam irradiation. Also, minimized beam spot radius (sub-tens nanometer) can be applied to FIB processing. With the ultimate goal of optimizing nano-scale pattern fabrication process, interaction between SAM coated specimen and $Ga^+$ ion dose during FIB processing was observed. From the experimental results, adequate ion dose for machining SAM material was identified.

  • PDF

The Influence of Using the Concept Cartoons about Middle School Students' Science Attitudes in the Lessons on Water Cycle Unit (물의 순환에 대한 과학 수업에서 개념 만화 활용이 중학생들의 과학 태도에 미치는 영향)

  • Wi, Su-Min;Jo, Hyeon-Jun;Mun, Eun-Yeong
    • Journal of Science Education
    • /
    • v.32 no.1
    • /
    • pp.19-32
    • /
    • 2008
  • The purpose of this study was to identify the influence of using the concept cartoons about middle school students' science attitude in the lessons on water cycle unit. For the purpose, they were developed to the learning program with concept cartoon and the instrument for the science attitude which has four categories; attitudes about science, attitudes about science subject, learning motives for science subject, and scientific attitudes. The research method was designed to quasi-experimental design. The concept cartoon was provided to the experimental group during nine lessons. Before and after the lessons in all two groups, the pre-post tests with the instrument were performed. The results from twice t-tests were shown that the domain of learning motives for science subject was only improved. From these, it were indicated that the concept cartoon was not effective all areas in science attitude, therefore the use in science lessons need to be restricted within narrow purpose.

  • PDF

Creep Behavior of Plastics Used in Automobile Instrument Panels (자동차 인스트루먼트 패널에 사용되는 플라스틱의 크리프 거동)

  • Kim, Young-Sam;Jeon, Chi-Hoon;Tumur-Ochir, Erdenebat;Yum, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1549-1556
    • /
    • 2011
  • Tensile and creep tests were performed at various temperatures to investigate the mechanical properties of plastics used in automotive instrument panels. Mechanical properties such as Young's modulus and Poisson's ratios changed markedly with the test temperature. Three-point bending creep tests were performed for three kinds of plastics under four loading conditions. Coefficients in the time-hardening power law creep equation were obtained from the experiment, and the creep behavior was represented by a simple expression. The results of finite element creep analysis showed good agreement with the experimental results, while the difference between the numerical and experimental results increased with the load.

Comparative Study on Cupping Apparatuses for Medical Use by Mechanical Stability and Functional Test (수동식 부항기의 기계적 안정성과 성능의 실험적 비교연구)

  • Soh, Mun-Gie;Song, Yun-Kyung;Lim, Hyung-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2008
  • Objectives : It is sure that standardization of medical instruments is very important and necessary. Cupping therapy is one of the traditional oriental medical method, and it is necessary to set up a standard of cupping therapy and instruments. Methods : We select 3 major cupping instrument makers according to a questionnaire survey of 2001 oriental medical doctors. Dae Gun is A maker, Han Sol is B maker, Dong Bang is C maker. And with these air pumps we make experiments on stability by an inner impact test and a falling test. With these cups we check stability by an inner impact test and a disinfection test. And to know function of these instruments we test a negative pressure and maintain attached cups until 5 to 10minutes. Results : All results of experiments(impacted test, disinfection test, falling test) on stability of cups and air pumps are suitable for medical instrument. And the efficiency of 3 major makers shows various results. Negative pressure of B group is the highest, C group is the second, A group is the lowest. Pressure maintenance test shows A and C group is comparatively up to the experimental standard(<10%), B group is comparatively below the experimental standard(<10%). Conclusions : Results show stability of cups and air pumps is suitable for medical instruments. And negative pressure of cupping and maintenance of pressure show various results. So it is necessary to set up a standard negative pressure of cupping and maintenance of pressure.