• Title/Summary/Keyword: Experimental conditions

Search Result 10,840, Processing Time 0.046 seconds

Noncondensable gas's influence in waster vapor absorption accompanying interfacial disturbance into aqueous solution of LiBr

  • Dong-Ho RIE;Keun-Oh Lee
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.63-70
    • /
    • 1992
  • The aim of this research is to obtain a basic quantitative understanding of the effect of a noncondensable gas on the absorption of water vapor by a $H_2O$ / LiBr combination with n-octanol as the surfactant. Nonflowing aqueous solutions of LiBr (40,45,50 mass%) were exposed to saturated water vapor following the addition of an n-octanol sufactant (0.01 and 0.6 mass%). A small amount of a noncondensable gas (air) was allowed into the absorber (0.03 volume%) and its effect was analyzed by measuring the amount of water vapor absorbed. This study will aid to predict the performance of heat pump and safety operating condition when the noncondensable gas is not allowed in the absorber The results indicate that, in the presence of small amounts of a noncondensable gas, vapor absorption enhancement ratios are less than half o( those obtained under the same experimental conditions when a noncondensable gas is not present (1). The presence of a noncondensable gas causes the partial vapor pressure of air to increase at the vapor / liquid interface, which results in an instability of vapor absorption rate nd. hence, in an inhibition of interfacial disturbance.

  • PDF

Experimental study on the ground subsidence due to the excavation of a shallow tunnel (경사지반에서 얕은터널의 굴착에 따른 지표침하에 대한 실험적 연구)

  • Park, Chan Hyuk;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.761-778
    • /
    • 2017
  • The need of the underground space for the infrastructures in urban area is increasing, and especially the demand for shallow tunnels increased drastically. It is very important that the shallow tunnel in the urban area should fulfill not only its own safety conditions but also the safety condition for the adjacent structures and the surrounding sub-structure. Most of the studies on the behavior of shallow tunnels concentrated only on their behaviors due to the local deformation of the tunnel, such as tunnel crown or tunnel sidewall. However, few studies have been performed for the behavior of the shallow tunnel due to the deformation of the entire tunnel. Therefore, in this study the behavior of the surrounding ground and the stability caused by deformation of the whole tunnel were studied. For that purpose, model tests were performed for the various ground surface slopes and the cover depth of the tunnel. The model tunnel (width 300 mm, height 200 mm) could be simulationally deformed in the vertical and horizontal direction. The model ground was built by using carbon rods of three types (4 mm, 6 mm, 8 mm), in various surface slopes and cover depth of the tunnel. The subsidence of ground surface, the load on the tunnel crown and the sidewall, and the transferred load near tunnel were measured. As results, the ground surface subsided above the tunnel, and its amount decreased as the distance from the tunnel increased. The influence of a tunnel ceased in a certain distance from the tunnel. At the inclined ground surface, the wider subsidence has been occurred. The loads on the crown and the sidewall were clearly visible, but there was no effect of the surface slope at a certain depth. The load transfer on the adjacent ground was larger when the cover depth (on the horizontal surface) was lager. The higher the level (on the inclined surface), the wider and smaller it appeared. On the shallow tunnel under inclined surface, the transfer of the ambient load on the tunnel sidewall (low side) was clearly visible.

The Comparison of Pregnancy Outcomes between Elective Two and Three Cleavage-state Embryos Transfer in Fresh IVF-ET (체외수정술시 난할단계 배아 2개와 3개를 이식했을 때의 임신예후의 비교)

  • Lyu, Sang-Woo;Won, Hyung-Jae;Lee, Woo-Sik;Han, Ji-Eun;Kim, A-Ri;Kim, You-Shin;Seok, Hyun-Ha;Yoon, Tae-Ki
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.1
    • /
    • pp.65-72
    • /
    • 2010
  • Objective: To compare the respective pregnancy outcomes of cycles undergoing elective two cleavage-stage embryos transfer (2ET) and three cleavage-stage embryos transfer (3ET) in fresh in vitro fertilization and embryo transfer (IVF-ET) program. Methods: We conducted a retrospective matched case control study that included 100 women with 2ET and 100 women with 3ET from January 2007 to June 2009. Subjects were matched for reproductive profiles and cycle characteristics. All of transferred embryos in both groups had good qualities. Pregnancy rates (PR), implantation rate, and multiple PR were compared. Results: Demographics, stimulation parameters and embryological data were comparable in both groups. Main pregnancy outcomes with 2ET and 3ET groups were not statistically different; implantation rate (41.0% vs. 35.3%), positive pregnancy rate (58.0% vs. 60.0%), clinical PR (55.0% vs. 59.0%), ongoing PR (51.0% vs. 55.0%), respectively. However, the 3ET group showed significantly higher multiple pregnancy and triplet pregnancy rates (30.9% vs. 50.8%, p=0.031; 1.8% vs. 11.9%, p=0.036, respectively). Conclusion: In women with favorable conditions and good quality embryos undergoing IVF, 2ET can get pregnancy outcomes comparable to those of 3ET and reduce multiple pregnancy (especially, triplet pregnancy).

Reliability Assessment of Flexible InGaP/GaAs Double-Junction Solar Module Using Experimental and Numerical Analysis (유연 InGaP/GaAs 2중 접합 태양전지 모듈의 신뢰성 확보를 위한 실험 및 수치 해석 연구)

  • Kim, Youngil;Le, Xuan Luc;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.4
    • /
    • pp.75-82
    • /
    • 2019
  • Flexible solar cells have attracted enormous attention in recent years due to their wide applications such as portable batteries, wearable devices, robotics, drones, and airplanes. In particular, the demands of the flexible silicon and compound semiconductor solar cells with high efficiency and high reliability keep increasing. In this study, we fabricated a flexible InGaP/GaAs double-junction solar module. Then, the effects of the wind speed and ambient temperature on the operating temperature of the solar cell were analyzed with the numerical simulation. The temperature distributions of the solar modules were analyzed for three different wind speeds of 0 m/s, 2.5 m/s, and 5 m/s, and two different ambient temperature conditions of 25℃ and 33℃. The flexibility of the flexible solar module was also evaluated with the bending tests and numerical bending simulation. When the wind speed was 0 m/s at 25 ℃, the maximum temperature of the solar cell was reached to be 149.7℃. When the wind speed was increased to 2.5 m/s, the temperature of the solar cell was reduced to 66.2℃. In case of the wind speed of 5 m/s, the temperature of the solar cell dropped sharply to 48.3℃. Ambient temperature also influenced the operating temperature of the solar cell. When the ambient temperature increased to 33℃ at 2.5 m/s, the temperature of the solar cell slightly increased to 74.2℃ indicating that the most important parameter affecting the temperature of the solar cell was heat dissipation due to wind speed. Since the maximum temperatures of the solar cell are lower than the glass transition temperatures of the materials used, the chances of thermal deformation and degradation of the module will be very low. The flexible solar module can be bent to a bending radius of 7 mm showing relatively good bending capability. Neutral plane analysis was also indicated that the flexibility of the solar module can be further improved by locating the solar cell in the neutral plane.

Changes of Stress Response and Physiological Metabolic Activity of Flounder, Paralichthys olivaceus Following to Food Deprivation and Slow Temperature Descending (먹이제한과 단기 수온하강 조건에서 넙치의 스트레스 반응과 생리학적 대사활성 변화)

  • Myeong, Jeong-In;Kang, Duk-Young;Kim, Hyo-Chan;Lee, Jeong-Ho;Noh, Jae-Koo;Kim, Hyun-Chul
    • Korean Journal of Ichthyology
    • /
    • v.23 no.2
    • /
    • pp.87-94
    • /
    • 2011
  • To find the preliminary environmental conditions for a short-time transport of living olive flounder, Paralichthys olivaceus, the stress response and physiological metabolic activity of the cultured fish to feed deprivation and slow temperature descending ($15.8^{\circ}C{\rightarrow}13.3^{\circ}C$) were monitored for 8 days. The monitored variables were the plasma alanine aminotransferase (ALT), aspartate aminotransferase (AST), glucose (GLU), total protein (TP), electrolytes ($Na^+$, $K^+$, $Cl^-$) and thyroid hormones ($TT_4$, $TT_3$, $FT_4$ and $FT_3$). In food deprivation experiment for 8 days, we did not find any statistical change of level in AST, ALT and electrolytes ($Na^+$, $K^+$, $Cl^-$), but found a significant decrease in TP and GLU. In thyroid hormones, the levels of four hormones in plasma were all showing a tendency to decrease. Especially, $FT_4$ and $TT_3$ were significantly decreased, indicating a withering of physiologic activity. In the temperature test, although no any significant change in AST, TP and electrolytes ($Na^+$, $K^+$, $Cl^-$), we observed a significant decrease of ALT and GLU following to temperature descending from $15.8^{\circ}C$ to $13.3^{\circ}C$ (P<0.05). In the levels of thyroid hormones, any significant change was not observed for experimental period. We conclude that the stress response and physiological activity of olive flounder were more influenced by feed deprivation than slow temperature descending at a transport of living fish, and plasma GLU appears to be sensitive factor to physiological metabolic activity, indicating that it could be used as a monitering mark or index for a health inspection of the fish.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

In Vitro/In Vivo Development after Thawing of Vitrified Mouse Blastocysts by Culture Condition and Embryo Transfer Method (초자화 동결된 생쥐 배반포기배의 융해 후 배양조건과 수정란 이식방법에 따른 체외/체내발달)

  • Kim, M.K.;Kim, E.Y.;Yi, B.K.;Yoon, S.H.;Park, S.P.;Chung, K.S.;Lim, J.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.3
    • /
    • pp.347-353
    • /
    • 1997
  • This study was to test whether in vitro/in vivo survival of vitrified mouse blastocysts was influenced by culture conditions and ET method. Mouse blastocysts were obtained from in vitro fertilization and cultured for 4 days in M16 medium, and they were vitrified in EFS40 which contained 40% ethlyene glycol, 18% Ficoll and 0.5 mol sucrose in PBS. In experiment I, in vitro and in vivo survival rate of these embryos were evaluated in different culture condition after thawing. When thawed embryos were cultured in M16 medium as a control, m-CR1 medium contained 20 amino acids (2% BME amino acis and 1% MEM non-essential amino acids solution) and 4 mg/ml BSA and cumulus monolayer cell co-cultured condition in mCR1 medium (10% FBS), their in vitro survival at 24 hr after thawing was not affected by culture condition (75.6, 83.1, 82.4%). However, in vivo survival rates of implantation in m-CR1 medium (80.4%) were significantly higher than those of M16 medium (51.2%), co-culture (57.1%) condition, although there was no difference in live fetuses rates on day 15 gestation (39.0, 49.0, 38.1%). In experiment II, the in vivo development potential of embryos by ET methods was examined. When blastocysts were transferred to the day 2, 3 pseudopregnant recipient without culture soon after thawing, no pregnant recipient was obtained on the day 2 pseudopregnancy, and 50% of pregnancy rates and 15.4% of live fetus rates were obtained on the day 3 pseudopregnant recipients. These results were significantly lower than those of transferred group (day 3 pseudopregnant recipients) after culture for 16 hr post thawing (73.5, 57.1%) (p<0.05). In experiment III, to elevate usability of delayed embryos in vitro/in vivo survival of vitrified embryos (day 4 early, day 5 early and expanding blastocyst) were examined. in vivo survival rates (live fetus, total implantation) were higher in day 4 early blastocysts (33.3, 66.7%) than in day 5 expanding blastocysts (29.0, 38.7%), although the highest in vitro survival rates were obtained in the day 5 expanding brastocysts (78.3%). Therefore, these results suggest that the in vitro/in vivo survival rates of vitrified embryos could be improve by the culture condition and ET method and that the in vivo development rates of delayed embryos were decreased with longer culture duration in vitro. It means that more effective cryopreservation was obtained in day 4 early blastocysts than in day 5 expanding blastocysts.

  • PDF

Role of HOXA Gene in Human Endometrial Decidualization (인간 자궁내막의 탈락막화에서 HOXA10 유전자의 역할)

  • Lee, Chang-Se;Park, Dong-Wook;Park, Chan-Woo;Kim, Tae-Jin
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.3
    • /
    • pp.207-216
    • /
    • 2010
  • Objective: This study was performed to clarify the role of HomeoboxA (HOXA) and its related signaling molecules in the decidualization of primary cultured endometrial cells. Methods: Human endometrial tissues were obtained by curettage of hysterectomy specimens from patients with conditions other than endometrial diseases. Tissues were minced and digested with Trypsin-EDTA for 20 min, $37^{\circ}C$. Cells were cultured with DMEM/F12 medium in $37^{\circ}C$, 5% $CO_2$ incubator for 24 hrs. Cells were treated with HOXA10 siRNA and added transforming growth factor (TGF)-${\beta}1$ (10 ng/mL) for 48 hrs to induces decidualization in vitro. Reverse transcription polymerase chain reaction analysis was accomplished to observe the expression of HOXA10, prolactin, cyclooxygenase (COX)-2, peroxisome proliferatoractivated receptor (PPAR)-$\gamma$, and wingless-type MMTV integration site family (Wnt). Results: HOXA10 expression was increased (1.8 fold vs. non-treated control) in TGF-${\beta}1$ treated cells. Decidualization marker, prolactin, was significantly increased in TGF-${\beta}1$ treated cells compared with HOXA10 siRNA treated cells. Endometrial cell differentiation marker, COX-2 was down-regulated by HOXA10 siRNA even if cells were treated with TGF-${\beta}1$. Wnt4 was down-regulated by treated with HOXA10 siRNA, this expression patters was not changed by TGF-${\beta}1$. Expression of PPAR-$\gamma$ was down regulated by TGF-${\beta}1$ in regardless of HOXA10 siRNA treatment. Conclusion: TGF-${\beta}1$ which is induced by progesterone in endometrial epithelial cells may induces stromal cell decidualization via HOXA10 and Wnt signaling cascade.

Species-specific Expression of Rpia Transcript in Cumulus-oocyte-complex (난자-난구세포 복합체에서 발현하는 Rpia 유전자의 종 특이적 발현)

  • Kim, Yun-Sun;Yoon, Se-Jin;Kim, Eun-Young;Lee, Kyung-Ah
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.34 no.2
    • /
    • pp.95-106
    • /
    • 2007
  • Objective: We previously identified differentially expressed genes (DEGs) between germinal vesicle (GV) and metaphase II (MII) mouse oocyte. The present study was accomplished as a preliminary study to elucidate the role of ribose 5-phosphate isomerase A (Rpia), the essential enzyme of the pentose phosphate pathway (PPP), in oocyte maturation. We observed expression of Rpia in the mouse and porcine oocytes. Methods: Expression pattern of the 11 MII-selective DEGs in various tissues was evaluated using RT-PCR and selected 4 genes highly expressed in the ovary. According to the oocyte-selective expression profile, we selected Rpia as a target for this study. We identified the porcine Rpia sequence using EST clustering technique, since it is not yet registered in public databases. Results: The extended porcine Rpia nucleotide sequence was submitted and registered to GenBank (accession number EF213106). We prepared primers for porcine Rpia according to this sequence. In contrast to the oocyte-specific expression in the mouse, Rpia was expressed in porcine cumulus and granulosa cells as well as in oocytes. Conclusion: This is the first report on the characterization of the Rpia gene in the mouse and porcine ovarian cells. Results of the present study suggest that the mouse and porcine COCs employ different mechanism of glucose metabolism. Therefore, the different metabolic pathways during in vitro oocyte maturation (IVM) in different species may lead different maturation rates. It is required to study further regarding the role of Rpia in glucose metabolism of oocytes and follicular cell fore exploring the regulatory mechanism of oocyte maturation as well as for finding the finest culture conditions for in vitro maturation.

Various Possibilities of Dispositif Film (디스포지티프 영화의 다양한 가능성)

  • KIM, Chaehee
    • Trans-
    • /
    • v.3
    • /
    • pp.55-86
    • /
    • 2017
  • This study begins with the necessity of the concept of reincarnation of film media and the inclusion of specific tendencies of contemporary films as post - cinema comes. Variable movements around recent films Challenging and experimental films show aesthetics that are difficult to approach with the analysis of classical mise en scene and montage. In this way, I review the dispositif proposed by Martin in films that are puzzling to criticize with the classical conceptual framework. This is because the concept of dispositive is a conceptual pile that extends more than a mise en scene and a montage. Dispositif films tend to be non-reproducible and non-narrative, but not all non-narrativef tendencies are dispositif films. Only the dispositif film is included in the flow. Dispositif movement has increased dramatically in the modern environment on which digital technology is based, but it is not a tendency to be found in any particular age. The movement has been detected in classical films, and the dispositif tendency has continued to exist in avant-garde films in the 1920s and some modernist films. First, for clear conceptualization of cinematic dispositif, this study examines the sources of dispositif debates that are being introduced into film theory today. In this process, the theory of Jean Louis Baudry, Michel Foucault, Agamben, Flusser, and Deleuze will help. The concept of dispositif was discussed by several scholars, including Baudry and Foucault, and today the notion of dispositif is defined across all these definitions. However, these various discussions are distinctly different from the cinematic dispositif or dispositif films that Martin advocates. Martin's proposed concept reminds us of the fundamentals of cinematic aesthetics that have distinguished between the mise-en-scene and the montage. And it will be able to reconsider those concepts and make it possible to view a thing a new light or create new films. The basic implications of dispositif are apparatus as devices, disposition and arrangement, the combination of heterogeneity. Thus, if you define a dispositif film in a word, it is a new 'constraint' consisting of rearrangement and arrangement of the heterogeneous elements that make up the conditions of the classical film. In order for something to become a new design, changes must be made in the arrangement and arrangement of the elements, forces, and forces that make up it. Naturally, the elements encompass both internal and external factors. These dispositif films have a variety of possibilities, such as reflection on the archival possibilities and the role of supervision, the reestablishment of active and creative audience, the reason for the film medium, and the ideological reflection. films can also 'network' quickly and easily with other media faster than any medium and create a new 'devised' aesthetic style. And the dispositif film that makes use of this will be a key keyword in reading the films that present the new trend of modern film. Because dispositif are so comprehensive and have a broad implication, there are certainly areas that are difficult to sophisticate. However this will have a positive effect on the future activation of dispositif studies end for end. Dispositif is difficult to elaborate the concept clearly, so it can be accessed from a wide range of dimensions and has theoretically infinite extensibility. At the beginning and end of the 21st century film, the concept of cinematic dispositif will become a decisive factor to dismantle old film aesthetics.

  • PDF