• 제목/요약/키워드: Experimental Design Technique

검색결과 1,035건 처리시간 0.022초

940K bbls FPSO의 선수갑판 Green Water에 관한 연구 (A Study of Green Water on the Bow Deck of 940K bbls FPSO)

  • 김용직;신기석;추교덕;서용석;이춘기;김문성
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.309-313
    • /
    • 2004
  • Prediction of green water loads acting an the bow deck is an essential part for the design of bow structures against the green water impact. Proper technique of the green water simulation is highly required for the prediction of green water loads. In this paper, a new numerical method for green water simulation, which is based an predictor-corrector-upwind finite difference scheme of the 2nd kind, is introduced. Through the comparisons between computed' results and experimental measurements, it is verified that the present numerical tool is adequate as a practical calculation tool for the green water problem.

  • PDF

Simulating three dimensional wave run-up over breakwaters covered by antifer units

  • Najafi-Jilani, A.;Niri, M. Zakiri;Naderi, Nader
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권2호
    • /
    • pp.297-306
    • /
    • 2014
  • The paper presents the numerical analysis of wave run-up over rubble-mound breakwaters covered by antifer units using a technique integrating Computer-Aided Design (CAD) and Computational Fluid Dynamics (CFD) software. Direct application of Navier-Stokes equations within armour blocks, is used to provide a more reliable approach to simulate wave run-up over breakwaters. A well-tested Reynolds-averaged Navier-Stokes (RANS) Volume of Fluid (VOF) code (Flow-3D) was adopted for CFD computations. The computed results were compared with experimental data to check the validity of the model. Numerical results showed that the direct three dimensional (3D) simulation method can deliver accurate results for wave run-up over rubble mound breakwaters. The results showed that the placement pattern of antifer units had a great impact on values of wave run-up so that by changing the placement pattern from regular to double pyramid can reduce the wave run-up by approximately 30%. Analysis was done to investigate the influences of surface roughness, energy dissipation in the pores of the armour layer and reduced wave run-up due to inflow into the armour and stone layer.

액체로켓엔진 시스템 해석 기술 소개 (Introduction to Systems Analysis Technique for a Liquid Rocket Engine)

  • 조원국;박순영;김철웅
    • 항공우주기술
    • /
    • 제13권1호
    • /
    • pp.70-75
    • /
    • 2014
  • 액체 로켓 엔진에 대한 에너지 밸런스 해석, 모드 해석, 비정상 해석 프로그램을 소개하였다. 유사 프로그램에 대한 결과, 공개된 실험 결과와 비교하여 해석 방법을 검증하였다. 에너지 밸런스 해석은 초기 개발 단계에서 활용된다. 모드 해석은 엔진 작동 조건, 시험조건 설정 및 엔진 성능 분산 분야에 활용된다. 비정상 해석을 통하여 추진제 유량, 추력, 비정상 조건에 대한 임펄스를 예측할 수 있다. 비정상 해석은 시동/종료 시퀀스 설정에 필수적이다. 본 해석 프로그램들은 한국형 발사체 엔진 개발에 활용될 것이다.

Design and Implementation of Solar PV for Power Quality Enhancement in Three-Phase Four-Wire Distribution System

  • Guna Sekar, T.;Anita, R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.75-82
    • /
    • 2015
  • This paper presents a new technique for enhancing power quality by reducing harmonics in the neutral conductor. Three-Phase Four-Wire (3P4W) system is commonly used where single and three phase loads are connected to Point of Common Coupling (PCC). Due to unbalance loads, the 3P4W distribution system becomes unbalance and current flows in the neutral conductor. If loads are non-linear, then the harmonic content of current will flow in neutral conductor. The neutral current that may flow towards transformer neutral point is compensated by using a series active filter. In order to reduce the harmonic content, the series active filter is connected in series with the neutral conductor by which neutral and phase current harmonics are reduced significantly. In this paper, solar PV based inverter circuit is proposed for compensating neutral current harmonics. The simulation is carried out in MATLAB/SIMULINK and also an experimental setup is developed to verify the effectiveness of the proposed method.

5㎓ 대역에서 동작하는 다중 U-슬롯 모양의 마이크로스트립 안테나의 설계 및 제작 (Design and Fabrication of Mulitiple U-shaped slot Microstrip Antenna on 5㎓ Application)

  • 윤중한;정계택;이상목;안규철;곽경섭
    • 대한전자공학회논문지TC
    • /
    • 제40권11호
    • /
    • pp.85-92
    • /
    • 2003
  • 본 논문에서는 5㎓ 대역에서 동작하는 다중 V-슬롯 모양의 마이크로스트립 안테나를 설계하고 제작하였다. 단일 U-슬롯 모양 위에 두 개의 작은 역 U-슬롯 모양을 갖도록 하였으며 접지면과 기판사이에 공기층을 삽입하여 충분한 대역을 얻고자 하였다. 여러 파라메타, 큰 U 슬롯모양 가로 길이, 세로 길이, 너비, 위치 그리고 두 개의 역 U 슬롯 모양 간격, 급전 위치 그리고 공기갭의 두께를 최적화시킨 후에 다중 U-슬롯 모양의 마이크로스트립 안테나가 제작되었으며 제작된 안테나의 측정결과는 다음과 같다. VSWR<2.0에서 20.4%의 대역폭과 5.5㏈i의 이득과 방사패턴을 얻었다.

Laboratory tests for studying the performance of grouted micro-fine cement

  • Aflaki, Esmael;Moodi, Faramarz
    • Computers and Concrete
    • /
    • 제20권2호
    • /
    • pp.145-154
    • /
    • 2017
  • In geological engineering, grouting with Portland cement is a common technique for ground improvement, during which micro-fine cement is applied as a slurry, such that it intrudes into soil voids and decreases soil porosity. To determine the utility and behavior of cements with different Blaine values (index of cement particle fineness) for stabilization of fine sand, non-destructive and destructive tests were employed, such as laser-ray determination of grain size distribution, and sedimentation, permeability, and compressive strength tests. The results of the experimental study demonstrated a suitable mix design for the upper and lower regions of the cement-grading curve that are important for grouting and stabilization. Increasing the fineness of the cement decreased the permeability and increased the compressive strength of grouted sand samples considerably after two weeks. Moreover, relative to finer (higher Blaine value) or coarser (lower Blaine value) cements, cement with a Blaine value of $5,100cm^2/g$ was optimal for void reduction in a grouted soil mass. Overall, study results indicate that cement with an optimum Blaine value can be used to satisfy the designed geotechnical criteria.

Modeling and a Simple Multiple Model Adaptive Control of PMSM Drive System

  • Kang, Taesu;Kim, Min-Seok;Lee, Sa Young;Kim, Young Chol
    • Journal of Power Electronics
    • /
    • 제17권2호
    • /
    • pp.442-452
    • /
    • 2017
  • This paper deals with the input-output modeling of a vector controlled PMSM drive system and design of a simple multiple model adaptive control (MMAC) scheme with desired transient responses. We present a discrete-time modeling technique using closed-loop identification that can experimentally identify the equivalent models in the d-q coordinates. A bank of linear models for the equivalent plant of the current loop is first obtained by identifying them at several operating points of the current to account for nonlinearity. Based on these models, we suggest a simple q-axis MMAC combined with a fixed d-axis controller. After the current controller is designed, another equivalent model including the current controller in the speed control loop shall be similarly obtained, and then a fixed speed controller is synthesized. The proposed approach is demonstrated by experiments. The experimental set up consists of a surface mounted PMSM (5 KW, 220V, 8 poles) equipped with a flywheel load of 220kg and a digital controller using DSP (TMS320F28335).

주위기체내에서의 두 액체분무간의 유동간섭현상에 대한 정상적 고찰 (An Experimental Study on the Behavior of Twin-Spray with Flow Interaction in a Condensable Environment)

  • 이상룡;정태식;한기수
    • 대한기계학회논문집
    • /
    • 제10권3호
    • /
    • pp.326-334
    • /
    • 1986
  • The effects of flow interaction between adjacent sprays in twin-spray system on the spatial distribution of injected liquid (water) and drop size distribution in condensable (steam) environment were carefully observed through experiments. The spatial distribution of injected liquid in twin-spray system appears to be more uniform than the simple superposition of the spatial distributions of liquid obtained from each individual spray. Drop size distribution was obtained by using the immersion sampling technique. It was found that, in the twin-spray, the larger numbers of small drops are collected throughout the spraying region due to the increase of entrainment velocity of ambient steam compared with the case of simple superposition of each individual spray. Moreover, in the overlapped portion of the twin-spray, the drop size distribution was changed also due to the collision between large drops. As a result, the behavior of twin-spray system (and eventually multiple-spray system) can not be predicted precisely by simple superposition of the behaviors of each constituting spray. Hence, for the design of multiple spray system, the effect of flow interaction between sprays should be taken into account seriously.

복합재의 탄성 및 감쇠계수 측정을 위한 실험연구 (An Experimental Study on the Measurement of Elastic and Damping Coefficients of a Composite Material)

  • 박한일;손재근;민천홍;배수룡
    • 대한조선학회논문집
    • /
    • 제44권1호
    • /
    • pp.26-31
    • /
    • 2007
  • Understanding viscoelastic properties of composite materials is essential for the design and analysis of composite structures. Specially, the loss factor and Young's modulus must be known to develop finite element codes for a composite structure with several damping materials. In this study, an advanced technique for obtaining accurate loss factor and Young's modulus of a composite structure is introduced based on the method of American Society for Testing and Materials (ASTM). The loss factor and Young's modulus of a composite structure are measured for different temperatures by performing the test in a vibration measurement room where temperature can be controllable from 5 to 45 Celsius.

국내 암환자와 관련된 연구논문의 메타분석 - 실험연구를 중심으로 - (An Integrative Review and Meta-analysis of Oncology Nursing Research : 1985-1997.2)

  • 임선옥;홍은영
    • 대한간호학회지
    • /
    • 제27권4호
    • /
    • pp.857-870
    • /
    • 1997
  • The purposes of this study were to describe 12 years of patient-related oncology nursing research in Korea, identifying various nursing interventions, and assesing the effectiveness of the interventions, through analysis and synthesis of the accumulated research papers. One hundred and seventy-nine studies were selected for this study and these were mostly descriptive in design (69.2%). Of the 179 studies, 25 met the criteria for meta-analytic treatment. Twenty-five experimental studies were found in theses and dissertations (68%), 92% used convenience sample, and the median sample size was 40. Subjects were predominantly in treatment and rehabilitation (76%). Most studies(68%) were not derived from a theory base, with only 8% reporting use of a nursing theory. Results of the meta-analysis are as follows. The effect size of the nursing intervention type was found to be significantly effective. The standardized mean difference ranged from a high positive of 2.55 to a low negative of -0.22. Direct personal nursing intervention method was more effective than indirect group method. Two nursing intervention methods were more effective than one. The greatest effect size was thyxical intervention. The greatest mean effect size was scalp hypothermia technique. Teaching was a frequent intervention after 1990, although a wide range of treatments were studied. Effect size of intervention for symptom management was largest in relieving pain. Effective intervention method for relieving anxiety was exercise.

  • PDF