• 제목/요약/키워드: Expansion valve

검색결과 241건 처리시간 0.037초

공조.냉동장치의 제어시스템 개발을 위한 팽창밸브 특성 (Expansion Valves Characteristics for Development of Control System on Air Conditioning and Refrigeration Systems)

  • 김재돌;장재은;윤정인
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.34-40
    • /
    • 1998
  • Performance characteristics of a refrigeration systems with various expansion valves and superheat changes were investigated experimentally. Experimental data have been taken utilizing three different devices; a thermostatic expansion valve, a linear type electronic expansion valve and a solenoid type electronic expansion valve. The data taken from tile three types of expansion valves were discussed with the temperature distribution of each zone in the evaporator and the superheat changes of the evaporator outlet In each zone temperature distribution fluctuated larger with the thermostatic expansion valve than with the electronic expansion valves. The optimum superheat ranged from $5^{\circ}C\;to\;15^{\circ}C$, and the superheat with the thermostatic expansion valve showed hunting phenomenon, which affected the evaporating and condensing temperature.

  • PDF

온도식팽창밸브의 전자식팽창밸브로의 대체 가능성에 관한 연구 (A Study on the Possibility for the Replacement of a Thermal Expansion Valve to an Electronic Expansion Valve)

  • 한도영;정성욱
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.695-700
    • /
    • 2006
  • For the precise superheat temperature control of an air conditioner, an electronic expansion valve may be used instead of a thermal expansion valve. In this paper, technical and economical aspects of expansion valves were studied in order to find out the possibility to use an electronic expansion valve to replace a thermal expansion valve.

  • PDF

병렬팽창 냉동시스템의 성능실험에 관한 실험적 연구 (An Experimental Study on the Performance Testing of Parallel Expansion Refrigeration System)

  • 구창대
    • 한국산업융합학회 논문집
    • /
    • 제14권2호
    • /
    • pp.79-85
    • /
    • 2011
  • This study has been experimented about refrigeration capacity difference. It has been used 3 method, Manual expansion valve, thermostatic expansion valve and capillary expansion valve, and tested under the same condition by using the performance testing of parallel expansion. In temperature change of the temperature room, thermostatic expansion valve method displayed the most lower temperature, $-18^{\circ}C$. In addition, the temperature, just before the expansion, also displayed the best result which was $4^{\circ}C$ lower than other expansion valve. In these results, it can be used for performance testing of parallel expansion refrigeration system.

특수 압력요기용 안전밸브의 2중 구조로 디스크의 최적설계 (Optimal Design of Dual-Structured Disc of a Safety-Valve for the Specialized Pressure Vessel Considering Thermal Expansion)

  • 김창호
    • 한국기계가공학회지
    • /
    • 제6권4호
    • /
    • pp.81-85
    • /
    • 2007
  • A safety valve is used for protecting the pressure vessel and facilities by discharging the operating fluid into the valve from the accident when the pressure is over the designated value. The fluid is sulfurous acid and nitric acid. etc. in the semi-conductor assembly line. Thus the valve elements material must be acid resistance. Teflon, which is used generally as inner parts of a valve, tends to easily sticks to sliding surface by thermal expansion under high temperature. Some studies are performed to change teflon to another material and shape to have a better fluidity under the condition. The analysis of the thermal expansion is conducted by commercial FEM software to improve the problems. Boundary conditions were temperature and load in this study. From the analysis, the thermal expansion of stainless steel is verified to be lower than that of teflon under high temperature. Thus coupled teflon/stainless steel-made valve is applied to assembly line without danger due to thermal expansion.

  • PDF

열팽창을 고려한 특수 압력용기용 안전밸브 디스크의 설계에 관한 연구 (A Study on the Disc Design of a Safety-valve for the Specialized Pressure-vessel Considering Thermal Expansion)

  • 강재원;김창호;강동호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1581-1584
    • /
    • 2007
  • The safety valve is the important equipment used to protect the pressure vessel and pressure facilities from overpressure by discharging the operation medium when the pressure of system is reaching the design pressure of the system. Some materials for a safety valve disk are studied in this paper. A studied safety valve has to resist sulfurous acid and nitric acid. etc. Furthermore teflon which is a general material of the valve easily sticks to a disk and a sliding part of the valve by thermal expansion. Therefore both teflon and stainless-steel are used to improve these problems. The analysis of the thermal expansion is conducted with commercial FEM software to improve the problems. Boundary conditions were temperature and load in this study. From the analysis, the thermal expansion of by teflon/stainless steel-made valve is lower than that of teflon-made valve under high temperature. Thus, teflon/stainless steel-made valve is safe and no malfunction by thermal expansion.

  • PDF

신냉매용 자동차 공조 시스템에서 블록식 팽창밸브의 설계 (A Design of the Block Type Expansion Valve in Automotive Air Conditioning System using HFC-134a)

  • 김경훈;박상훈;강우
    • 한국자동차공학회논문집
    • /
    • 제11권4호
    • /
    • pp.196-203
    • /
    • 2003
  • This study was performed to design the optimal block type expansion valve through analyzing the characteristics of the block type expansion valve in automotive air conditioning system using HFC-134a. Because an alternative refrigerant (HFC-l34a) is being used instead of CFC-12 for automotive air conditioning system, newly designed air conditioning components are necessary due to changes in characteristics. The performance tests were accomplished through the test bench, that is manufactured based on the study. And then it was carried out to measure the variation of temperature and pressure at each part of the air conditioning system according to the compressor speed.

서브쿨링향상을 위한 차량공조 시스템의 냉방성능에 관한 연구 (A Study on Refrigeration Performance of Vehicle HVAC System for Sub-Cooling Improvement)

  • 박만재
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2004
  • The general method which changes sub-cooling of refrigerant is to control the expansion valve in the state of mixing with liquid and gas phase. In this study, the performance of vehicle air conditioning system is to control either changing the expansion valve or adding the sub condenser. Therefore, this research finally is tested in case of the fourth test procedure, the second test was suitable for a valve opening area due to adjusting valve slope in comparison with the other test. The other test except for the second test happened to do liquid back due to the excessively liquified refrigerant into the system. In conclusion, the second test was appeared not to be influenced upon liquid back, and it is to expect positive performance by controlling an expansion valve. Therefore, it will be also useful to research for an increase of compressor efficiency Performance improvement of an air conditioner is to reinforce the suction performance of the evaporator and increase the sub-cooling, which make use of the sub-cooling system.

전자팽창밸브 개도에 따른 가변속 수냉각기의 용량제어 특성 (Characteristics of Capacity Control of Variable Speed Water Cooler with the Electronic Expansion Valve Open/Close Degree)

  • 백승문;문춘근;김현우;정석권;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권2호
    • /
    • pp.282-288
    • /
    • 2010
  • 본 연구는 전자팽창밸브의 개도변화에 따른 가변속 수냉각기의 용량제어 특성에 관한 논문이다. 인버터에 의한 가변속 압축기를 사용한 냉각기를 최적으로 제어하기 위한 선행 연구이며 압축기 회전수별로 제어대상인 전자팽창밸브를 조절하여 증발기 출구의 과열도를 일정한 값으로 제어함으로써 최적의 냉각능력을 얻을 수 있는 과열도 값을 찾는 것을 목표로 하였다. 본 실험의 결과 압축기 회전속도가 일정할 때 팽창 밸브의 개도변화에 따라서 냉각능력이 최대가 되는 지점의 개도량을 실험을 통해서 파악할 수 있었다.

3 밸브형 맥동관 냉동기의 작동 해석 (Analysis of the Operation of a 3 Valve-type Pulse Tube Refrigerator)

  • 송영식;조경철;정평석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.335-340
    • /
    • 2000
  • A 3 valve-type pulse tube refrigerator optains its cooling effect from pressure drop by releasing the part of the charged gas through hot end nozzle. The objective of this study is to analyze the performance and to find an optimal expansion pressure of the 3 valve-type pulse tube refrigerator. It is assumed that gas lumps are not mixed and periodically repeat the adiabatic compression and expansion processes. And the nodal model is applied for the analysis of the regenerator. As the result of analysis, the optimum pressure at the end of expansion process was about 80-90% of the maximum pressure.

  • PDF